research centers


Search results: Found 2

Listing 1 - 2 of 2
Sort by

Article
Study of Aeration TimeEffect on COD and Ammonia removal by Sequencing Batch Reactor

Author: Husham T.Y.Ibrahim
Journal: Journal of University of Babylon مجلة جامعة بابل ISSN: 19920652 23128135 Year: 2017 Volume: 25 Issue: 1 Pages: 276-284
Publisher: Babylon University جامعة بابل

Loading...
Loading...
Abstract

Four operational cyclic modes for a Sequencing Batch Reactor containing activated sludge was investigated in order to treat a part of domestic wastewater from the student's hostels at B campus in Chongqing University in China, comparison was made for these cyclic modes (first, second, third and fourth)in order to remove (COD, Ammonia), each cyclic mode operated in a different conditions as aeration time, cyclic time and concentrations in order to choose best cyclic mode gives a good removal efficiency and in the same time explain effect aeration time on removal COD and Ammonia by using sequencing batch reactor under normal temperature. The results showed that the CODremoval efficiency that has been achieved by SBR system were 90.14%, 87.86%,83.1%and 81.3% under first, second, third and fourthcyclic modes respectively, while Ammonia removal efficiency were 84.56%,74.82 %,52.74% and 32.53% under first, second, third and fourthcyclic modes respectively

تم أختبار أربع دورات زمنية تشغيلية للمفاعل الدفقي المتسلسل SBR والذي يعمل بالاعتماد على مبدأ الحمأة المنشطة وذلك من خلال معالجة مياه الفضلات المنزلية الناتجة من القسم الداخلي للطلبة في الموقع B التابع لجامعة تشونغتشنغ في جمهورية الصين الشعبية , وقد تم عمل مقارنة بين نتائج فحص معالجة الملوثات (COD والامونيا ) وللدورات الزمنية الأولى والثانية والثالثة والرابعة حيث ان كل دورة زمنية تختلف عن الأخرى بوقت التهوية والترسيب والوقت الكلي للدورة وبالتالي يتم اختيار الدورة الزمنية الأفضل وذلك بالاعتماد على نتائج كفاءة الازالة للملوثات (COD والامونيا ) باستخدام المفاعل الدفقي المتسلسل SBR وتحت درجة الحرارة الاعتيادية, وكانت النتائج التي تم الحصول عليها توضح بأن كفاءة الأزالة لمتطلب الاوكسجين الكيميائي COD هي: 90,14% , 87,86% , 83,1% و 81,3% وللدورات الأولى والثانية والثالثة والرابعة على التوالي, بينما كانت نتائج كفاءة الازالة للأمونيا هي: 84,56% , 74,82% , 52,74% و 32,53% وللدورات الأولى والثانية والثالثة والرابعة على التوالي.


Article
Performance Evaluation of Al-RustamiyaWastewater Treatment Plant
تقييم اداء محطة الرستمية لمعالجة مياه الصرف الصحي

Author: AbdulKarim Muneer AbdulRazzak عبدالكريم منيرعبدالرزاق
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2013 Volume: 19 Issue: 4 Pages: 429-438
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Al-Rustamiya sewage treatment plant (WWTP) serves the east side of Baghdad city (Rusafa) and is considered one of the largest projects.It consists of three parts (old project F0, first extension F1, and second extension F2) that treat wastewater and the effluent is discharged into Diyala river and thus into the Tigris River. These plants are designed and constructed with an aim to manage wastewater to reachIraqi effluent standard for BOD5, COD, TSS and chloride concentrations of 40, 100, 60 and 600 mg/L respectively. The data recordedfrom March till December 2011 provided from Al-RustamiyaWWTP, were considered in this study to evaluate the performance of the plant. The results indicated that the strength of the wastewater entering the plant varied from medium to high. The average concentrations of the effluent of BOD5, COD, TSS and chloride were within Iraqi effluent standards. The overall efficiency removalswere:For BOD5: 92.1, 90.31, and 92.96% for F0, F1, and F2 respectively COD: 88.23, 87.9, and 87.95% for F0, F1, and F2 respectively TSS: 86.98, 80.72, and 89% for F0, F1, and F2 respectively Chloride: 14.79, 15.37, and 15.31% for F0, F1, and F2 The mean value of BOD5/COD ratio of the raw wastewater was 0.67 as for typical untreated domestic wastes. The mean BOD/COD ratios of the treated sewage from F0 was 0.48, from F1 0.50 and from F2 0.38. These ratios did not confirm with the typical ratios indicating that the wastewaterneeds more treatment.

تخدم محطة معالجة مياه الصرف بالرستمية الجانب الشرقي لمدينة بغداد الرصافة ويعتبر واحد من اكبر المشاريع ويتالف من ثلاثة اجزاء (المشروع القديم F0والتوسعة الاولىF1 والتوسعة الثانية F2) ويقوم المشروع بمعالجة مياه الصرف الصحي ورمي المياه بعد المعالجة الى نهر ديالى وهكذا الى نهر دجلة بعد المرور بمجموعة من العمليات. وهذه المحطة مصممة لمعالجة مياه الصرف الصحي يموجب المواصفة العراقية 40لتراكير BOD5,CODوالمواد العلقة والكلوريد المساوية الى 40 و100و60و 600 ملغم/لتر على التوالي.القراءات اليومية للفترةمن بداية شهر اذار ولغاية نهاية كانون الاول عام 2011 لقياسات خصائص مياه الصرف الصحي في مداخل ومخارج المحطة زودت من ادارة محطة معالجة الرستميةلتقييم اداء المحطة.النتائج اظهرت ان قوة مياه الصرف الصحي تتفاوت من الوسط الى المستوى العالي وان المياه المعالجة ذات تراكيز لل BOD5 و COD والمواد العالقة والكلوريدكانت ضمن المواصفة العراقية لرمي المياه المعالجة الى المصادر المائية. والاداء العام لمحطة الرستمية بمراحله المشار لها يكون جيد .وكانت كفاءة الازالة العامة هي:1-قيم ال BOD592.1 و 90.31 و 92.96% على التوالي للرستمية FoوF1 و F22-قيم ال COD87.23 و 87.9و 87.95 %على التوالي للرستمية FoوF1 و F23-قيم ال86.98 SS و 80.72و 89%على التوالي للرستمية FoوF1 و F24-قيم الكلورايد 14.79 و 15.37و 15.31% على التوالي للرستمية FoوF1 و F2.ان متوسط قيمة نسبة (BOD5/COD) لمياه الصرف الخام كانت 0.67 وكما هي لمياه الصرف المنزلية غير المعالجة. واماللمياه الصرف المعالجة فان معدل نسبة BOD5/COD في الرستمية القديم F0هي 0.48 وبالنسبة للتوسع الاولFفكانت0.50 والبالنسبة للتوسع الثاني Fكانت النسبة 0.38 . وهذه النسب من (BOD5/COD) لم تكن مطابقة للنسب المثالية للمياه المعالجة.و هذه المياه تحتاج الى معالجة اكثر.

Listing 1 - 2 of 2
Sort by
Narrow your search

Resource type

article (2)


Language

English (2)


Year
From To Submit

2017 (1)

2013 (1)