research centers


Search results: Found 9

Listing 1 - 9 of 9
Sort by

Article
Effect of Vertical Partition on Natural Convection Flow
تأثیر الحاجز العمودي على جریان الحمل الطبیعي داخل حیز ذو جدار مائل

Loading...
Loading...
Abstract

In this paper a numerical study for the natural convection in an enclosure withadjacent single wall using vertical adiabatic partition attached to bottom wall. The verticalwalls of the enclosure are isothermal while the bottom and top horizontal walls areinsulated. The temperature of the left vertical wall is higher than the temperature of theright vertical wall. The study included a change in the inclination of the cold wall of(f=15°, 30° and 45°), Rayleigh number of (Ra=103 to 105), length of partition of (YP= 0.2,0.3 and 0.4) and location of partition of (XP=0.25 and 0.5). A finite difference method wasapplied to solve the governing equations using Gauss-siedel iterative technique. Results forthe mean Nusselt number, and contour maps of the streamlines and isotherms line arepresented. It has been found that Nusselt number increases with an increase in Rayleighnumber, inclination of cold wall with percentage of (10-16%) and location of partition withpercentage of (3-14%) while decreases with increasing in partition length with percentageof (5.4-7%).

في هذا البحث تم إعداد دراسة عددية للحمل الطبيعي لحيز فيه احد الجدران المتجاورة مائل باستخدام حاجز عمودي ملاصق للجدار الأسفل. الجدارين العموديين للحيز لهم درجة حرارة ثابتة بينما الجدارين الأفقيين الأعلى والأسفل معزولين. درجة حرارة الجدار الأيسر أعلى من درجة حرارة الجدار الأيمن. تضمنت الدراسة تغيير في ميلان الجدار البارد عند (15 و 30 و 45) و عدد رالي (103 الى 105) و طول الحاجز عند (0.2 و 0.3 و 0.4) وموقع


Article
Adiabatic and Separated Flow of R-22 and R-407C in Capillary Tube
الجریان الادیاباتي المنفصل لمائعي التثلیج R-407Cو R- 22 داخل الانبوب الشعري

Author: Ahmed Abdulnabi Imran
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2009 Volume: 27 Issue: 6 Pages: 1074-1082
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

In this paper adiabatic flow in capillary tube is analyzed and modeled for R-22 andalternative R-407C. The equations of continuity, energy and pressure drop through acapillary tube are presented. A mathematical model of sub–cooled flow region andtwo–phase flow region is developed. The results of the calculation compared withexperimental data presented in the technical literature will be shown in the presentarticle in order to validate the model developed. This numerical model is capable ofproviding an effective means to analyze capillary tube performance to optimize andcontrol an R – 22 and R – 407C in an air – conditioning systems.

تم في هذا البحث بناء انموذج رياضي للجريان الادياباتي داخل الانبوب الشعري ولمائعي باستخدام معادلات الاستمرارية والطاقة وتمثيل هبوط الضغط خلال ,( R-407C و R- التثليج ( 22 الانبوب الشعري . الانموذج الرياضي يتضمن بناء انموذج لمنطقة الجريان الاحادي الطور السائل وانموذج اخر لمنطقة الجريان الثنائية الطور . تم مقارنة النتائج الحسابية مع النتائج العملية المتوفرة في البحوث السابقة لغرض التحقق من صحة الانموذج وامكانية استخ دامه لتحليل اداء منظومات التثليج الانضغاطية للوصول للامثلية.


Article
A NUMERICAL ANALYSIS OF ADIABATIC CAPILLARY TUBE PERFORMANCE IN VAPOR COMPRESSION REFRIGERATION SYSTEMS
تحليل عددي لأداء الأنابيب الشعرية الأديباتيه في منظومات التبريد الأنضغاطيه

Author: Dr. Ali Hussain Tarrad
Journal: Iraqi journal of mechanical and material engineering المجلة العراقية للهندسة الميكانيكية وهندسة المواد ISSN: 20761819 Year: 2008 Volume: 8 Issue: 3 Pages: 201-218
Publisher: Babylon University جامعة بابل

Loading...
Loading...
Abstract

This paper represents a numerical analysis intended for the selection and geometry design of the capillary tubes used in the vapor compression refrigeration units. This expansion component is usually selected for small home air conditioning units and domestic refrigerators and freezers for their ease integration with the cooling units and cheap prices. The numerical step by step model suggested in this work depends mainly on the idea of the control volume theory for the conservation of mass, energy and linear momentum of fluid refrigerants flowing inside the capillary tube. The flow regime is divided into a number of increments for which the conservation expressions were solved simultaneously for the physical characteristics parameters. These are temperature, pressure, and vapor quality and mixture velocity along the capillary tube from the entrance at the high pressure side to the exit at the low pressure side of the refrigeration unit. The theoretical prediction for the profile of the characteristics parameters showed a good agreement with available experimental data in the literature and the ASHRAE published rating charts of the capillary tubes.

يمثل البحث الحالي تحليل عددي مزمع استخدامه لاختيار وتصميم الأنابيب الشعرية المستخدمة في منظومات التبريد الأنضغاطية. وغالباً ما تستخدم هذه الأنابيب لأغراض تخفيض الضغط في منظومات تكييف الهواء المنزلية بالإضافة للثلاجات والمجمدات لسهولة تركيبها و توافقها للعمل مع وحدات التبريد ولرخص سعرها. النموذج المقترح يمثل تحليل عددي بطريقة الخطوة – خطوة يعتمد على مبادئ حفظ الكتلة, الطاقة والزخم الخطي لمائع التثليج أثناء مروره عبر ألأنابيب ألشعرية وتطبيقها لحجم متناهي للمائع. تم تقسيم نظام الجريان للمائع لعدد من الأحجام الصغيرة واتي تم عندها حل معدلات التمثيل لحفظ المتغيرات أعلاه لتحديد المتغيرات ألفيزياوية والتي تحدد ملامح أداء الأنابيب الشعرية. هذه المتغيرات تمثل توزيع درجات الحرارة, الضغط, النسبة المئوية للبخار وسرعة الخليط (البخار والسائل) لمائع التبريد على طول الأنبوب الشعري من نقطة الدخول لجانب الضغط العالي إلى نقطة الخروج لجانب الضغط الواطئ لمنظومة التبريد. التنبؤ النظري لتوزيع المتغيرات أعلاه على طول الأنبوب بينت تطابق جيد مع القيم التجريبية المتوفرة في الأدبيات وكذلك عند مقارنتها مع مخططات الأداء المنشورة في أدبيات منظمة (ASHRAE) للأنابيب الشعرية.


Article
Numerical Analysis Of Refrigerant Flow In Different Types Of Capillary Tubes Used R1270
تحليل عددي لجريان المائع في انواع مختلفة من الانابيب الشعرية باستخدام غاز R1270

Author: Haider ali hussen حيدر علي حسين
Journal: Journal of Engineering and Sustainable Development مجلة الهندسة والتنمية المستدامة ISSN: 25200917 Year: 2013 Volume: 17 Issue: 6 Pages: 10-21
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

The capillary tube is a common expansion device used in small sized refrigeration and air-conditioning systems. The main focus lies on the analysis of the refrigerant flow behavior in the along the capillary tube with different shapes (straight-coiled-serpentine) as well as using alternative (R1270) with different geometrical parameters by using a commercial code FORTRAN power station for the simulation. Capillary geometrical parameters will include diameter, coiled diameter, and curve diameter. Results showed that when capillary tube internal diameter increase from 1.4 mm to 1.8 mm. Straight tube length increases from (1.2978m) to (4.8738m) with ratio (73.37%) , Coiled tube length increases from (0.589m) to (1.958m) with ratio (69.91%) at coiled diameter (dd=10mm) ,and The serpentine tube length increases from (0.859m) to (2.671m) with ratio (67.84%) at curve radius ( )or curve diameter (dr=10mm).. The ideal capillary tube type is coiled. Because length decrease with comparison straight and serpentine.

إنّ الإنبوبَ الشعريَ هو أداة توسّعِ مشتركةِ إستعملتْ في التبريدِ بحجمِ الصغيرِ وتكييف الأنظمةِ. يهدف البحث على تحليلِ سلوكِ تدفقِ المبرّدَ على طول الإنبوبِ الشعريِ بالأشكالِ المختلفةِ (أفعوانية مستقيمة ملفوفة) بالإضافة إلى إستعمال البديلِ (R1270)مع مختلف المتغيرات الهندسية بإستعمال لغةِ فورتران للمحاكاةِ..المتغيرات الهندسية للانبوب الشعري ستتضمن قطر, قطر اللفة ,قطر التقوس .أظهرت النتائج بأنّ عندما يزيد القطر الداخلي للانبوب الشعري من (1.4 مليمتر -1.8 مليمتر) طولَ الإنبوبِ المستقيمِ يَزِيدُ مِنْ (1.2978 m) إلى (4.8738 m) بالنسبةِ (73.37 %) ويزيد طولِ الإنبوبِ الملفوفةِ مِنْ (0.589 m) إلى (1.958 m) بالنسبةِ (69.91 %) عند القطرِ الملفوفِ (dd =10 مليمتر) ويَزِيدُ طولَ الإنبوبِ الأفعوانيِ مِنْ (0.859 m) إلى (2.671 m) بالنسبةِ (67.84 %) عند نصفِ قطر التقوس ( ) أَو قطر التقوس (dr=10mm). إنّ نوعَ الإنبوبِ الشعريِ المثاليِ هو ملفوفُ. لان الطولِ اقل بالمقارنة مع الانبوب المستقيم والأفعواني.


Article
Study The Effect Of Water – Gas Shift Equilibrium on Adiabatic Flame Temperature for Alkanes Family Fuels at rich conditions

Author: Tahseen Ali Gabbar
Journal: University of Thi-Qar Journal for Engineering Sciences مجلة جامعة ذي قار للعلوم الهندسية ISSN: 26645564/26645572 Year: 2015 Volume: 6 Issue: 3 Pages: 90-100
Publisher: Thi-Qar University جامعة ذي قار

Loading...
Loading...
Abstract

The effect of water – gas shift equilibrium on adiabatic flame temperature for Alkanes family fuels was studied. The calculations of adiabatic flame temperatures were carried out by developing a program by using visual basic 6 language, based on a general algorithm meant to compute the equilibrium composition of products for any fuel–oxidizer gaseous mixture. The algorithm is based on the thermodynamic principles. Ten compounds were considered as products: the fuel (CnH2n+2), CO2, CO, H2O, N2, O2, CH4, C2H6, C3H8, C4H10, H2, their heat were capacities expressed as function of temperature with the form: Cp = ao+a1T+a2T2 +a3T3. Two methods with and without water – gas shift equilibrium were used to analysis the products gases. The results showed, adiabatic flame temperature calculated with water – gas shift equilibrium greater than that calculated without water – gas shift equilibrium.


Article
Numerical Study of Refrigerant Flow in Capillary Tube Using Refrigerant (R134a)(English))
دراسة عددية لجريان مائع التثليج في الأنبوبة الشعرية باستخدام مائع التثليج (R134a)

Authors: Dr. Amir S. DawoodAss د. أمير سلطان داؤود --- Salim Ibrahim Hasan سالم إبراهيم حسن
Journal: AL-Rafidain Engineering Journal (AREJ) مجلة هندسة الرافدين ISSN: 18130526 Year: 2013 Volume: 21 Issue: 1 Pages: 1-19
Publisher: Mosul University جامعة الموصل

Loading...
Loading...
Abstract

Abstract The present research aims at buildingof a mathematical model using (Engineering Equation Solver) (EES) software to analyze the flow of the refrigerant R134a into two configurations of adiabatic capillary tubes (straight and helical coiled tubes) which are used widely in a household refrigerator, freezer and water cooler. The governing equations which depend on the conservation of mass, momentum, and energy have been coded in order to calculate the length of the single-phase flow region. Moreover, the two-phase regionhasbeen divided numerically depending on homogenous flow assumption after determining the boundary conditions and calculating the physical variables at each point of the numerical divisions by using successive substitution method using iteration loops. Finite difference scheme, the length of thetwo-phase region and the total length for the capillary tube have also been determined. The results show that the behavior of the flow is similar for both forms with regard to the distribution of variables (pressure and temperature drop, dryness fraction, velocity and entropy) over the whole length , while the helical coiled tube length for all cases is shorter than the straight tube at the same conditions. The main parameters that affect the size of capillary tube and the behavior of refrigerant through it have been shown. The tube length increased with the increase of (condenser temperature, degree of sub-cooling and tube diameter) and decreased with the increase of mass flow rate and roughness. The helical tube length increased by increasing coil diameter and coil pitch . The results of the present study agree with the experimental data of previous works with error not exceeding ±10% .Keywords : Adiabatic capillary tube, Household refrigerators, R134a, EES, Helical, Two-phase flow.

الخلاصة يتضمن البحث الحالي بناء أنموذج رياضياتي لتحليل جريان مائع التثليج R134a في شكلين من الأنابيب الشعرية الأديباتية (المستقيمة والملفوفة بشكل لولبي) المستخدمة بشكل واسع في الثلاجات والمجمدات وبرادات الماء المنزلية باستخدام برنامج حل المعادلات الهندسية (EES). لقد تمت برمجة المعادلات الحاكمة المعتمدة على معادلات حفظ الكتلة والطاقة والزخم, لحساب طول المجال أحادي الطور ومن ثم تقسيم المجال ثنائي الطور عددياً بالاعتماد على فرضية الجريان المتجانس بعد حساب الظروف المحددة وحساب المتغيرات الفيزياوية في كل نقطة من التقسيم العددي بطريقة التعويض المتعاقب وذلك بعمل حلقات تكرارية, وحساب طول المجال الثنائي الطور بطريقة الفرق المحدد وبعدها تم حساب الطول الكلي للأنبوب . تبين من النتائج أن سلوك الجريان متشابه في كلا الشكلين من حيث توزيع المتغيرات (انحدار الضغط ودرجة الحرارة ونوعية البخار والسرعة والإنتروبي) على طول الأنبوب . لكن طول الأنبوب الملفوف يكون في جميع الحالات أقصر من طول الأنبوب المستقيم عندما تكون المعالم الأخرى ثابتة. وتم توضيح المعالم الرئيسية التي تؤثر على اختيار الحجم المناسب للأنبوب وعلى سلوك جريان المائع خلاله . وبينت النتائج أن طول الأنبوب يزداد بزيادة كل من (درجة حرارة المكثف ودرجة التبريد الدوني وقطر الأنبوب) ويقل بزيادة (معدل جريان الكتلة وخشونة السطح الداخلي للأنبوب) وكذلك يزداد بزيادة (قطر اللفة وخطوة اللفة). وأظهرت نتائج الدراسة الحالية توافقاً جيداً بالمقارنة مع البيانات التجريبية في الدراسات السابقة وبنسبة خطأ لاتتجاوز ±10% .


Article
The Effects of Inclination and Compounds Angles of Round Holes in Staggered Rows on Adiabatic Film Cooling Effectiveness of Vane Suction side
تاثيرات زوايا الميل والدوران للثقوب الدائرية في الصفوف المتخالفة على كفاءة التبريد الغشائي لجانب السحب من ريش التوجيه الرئيسية في التوربين

Authors: Najdat N. Abdullah نجدت نشات عبد الله --- Rashid Khalid Nsaif راشد خالد نصيف
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2016 Volume: 22 Issue: 6 Pages: 100-116
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The aim of this work is oriented to increase film cooling effectiveness value through numerical investigations for flow of Mach number not more than 0.3 around vane surface, to find the effects of inclination and compounds angles of round holes in staggered rows on adiabatic film cooling effectiveness of vane suction side. Multi cylindrical film cooling hole cases were studied with pitch ratio P/d =2 and 3, local blowing ratios M=0.382, 0.77 and 1.14, inclination angles =30° and 45°, compound angles β= 0°, 15°, 30° and 45° and local momentum ratios I= 0.084, 0.34 and 0.756 for better cooling process. A numerical technique, using ANSYS-FLUENT version 14.5, was used to solve governing partial differential equations of mass, momentum (Navier Stokes equations) and energy conservations in three dimensions with a v^2-f turbulence model that involves the solution of the four transport equations. Based on the results of the numerical solution, the best film cooling configuration, blowing ratio, with the range of actual engine flow conditions, dimensions and vane geometry; density ratio 1.74 , temperature ratio 0.57 and blowing ratio M=0.382, 0.77 and 1.14 was obtained. The best case for inclination angle =30°, P/d=2 was at M=1.14 and β=0° for the total average effectiveness along 60L/d of surface suction side was 0.616, while the best case for inclination angle =45°, P/d=2 was at M=0.382 and β=30° for the total average effectiveness along 60L/d of surface suction side was 0.516.In addition, comparisons were performed with available other work, where the experimental total average effectiveness results of Dees et al., 2011 were in good agreements with the numerical results of current work with a maximum deviation of 9.9% at I=0.34 and 3.6% at I=0.75.

ان الهدف من هذه الدراسة هو زيادة كفاءة التبريد الغشائي من خلال دراسة نظرية لجريان هواء برقم ماخ لا يزيد عن 0.3 حول سطح الريشة لغرض الوصول الى تاثيرات زوايا الميل والدوران للثقوب الدائرية في الصفوف المتخالفة على كفاءة التبريد الغشائي لجانب السحب من ريش التوجيه الرئيسية في التوربين. تمت دراسة العديد من الحالات نظريا لثقوب تبريد اسطوانية بنسبة مسافة بين ثقبين الى قطر الثقب هي 2 و3 وبمعدل ضخ نسبة الى السرعة الموقعية للجريان الرئيسي هو 0.328 و 0.77 و 1.14 وبزاوية توجيه علوي °30 و°45 وزاوية توجيه جانبي 30°, 15°, 0° , 45° وبعزم ضخ 0.756, 0.34, 0.084 لافضل تبريد. باستخدام الحل العددي بواسطة البرنامج ANSYS-FLUENT version 14.5 تم حل المعادلات التفاضلية الجزئية بالاتجاهات الثلاثة للكتلة والعزم والمعروفه Navier Stokes equations بالاضافة لمعادلة الطاقة وباستخدام نموذج v^2-f للجريان المضطرب الذي يشمل اربع معادلات انتقال. بالاعتماد على نتائج الحل العددي والتي هي بظروف مشابهة لظروف المحرك التوربيني من الناحية النسبية نسبة كثافة 1.74, نسبة درجات حرارة 0.57, نسبة ضخ 0.77,0.382 1.14, تم الوصول الى أمثل: شكل وكمية الضخ. الحالة الامثل عندما تكون زاوية الميل =30° , P/d=2 هو عند and β=0° M=1.14 حيث المعدل الكلي لكفاءة التبريد لطول 60L/d من سطح السحب لريشة التوربين هو 0.616, بينما الحالة الامثل عندما تكون زاوية الميل =45° , P/d=2 هو عند M=0.382 and β=30° حيث المعدل الكلي لكفاءة التبريد لطول 60L/d من سطح السحب لريشة التوربين هو 0.516.تمت المقارنة مع بحوث متوفرة لاعمال أخرى حيث كانت النتائج العملية لمعدل التبريد الكلي للباحث Dees et al., 2011 متقاربة بشكل جيد مع النتائج العملية لهذه الدراسة وكانت اعلى نسبة للاختلاف بين العملين هو %9.9 عند نسبة عزم للضخ 0.34 و %3.6 عند نسبة عزم ضخ 0.75.


Article
EXPERIMENTAL INVESTIGATION ON DIRECT EVAPORATIVE AIR COOLER PERFORMANCE WITH CELLULOSIC PADS

Author: Alaa Ruhma Al-Badri
Journal: Al-Qadisiyah Journal for Engineering Sciences مجلة القادسية للعلوم الهندسية ISSN: 19984456 Year: 2017 Volume: 10 Issue: 4 Pages: 525-535
Publisher: Al-Qadisiyah University جامعة القادسية

Loading...
Loading...
Abstract

Evaporative cooling is an economic and environment-friendly technique for air cooling. This technique may involve air cooling with humidification (direct evaporative cooling) or sensible air cooling only (indirect evaporative cooling). In this study, the saturation efficiency of direct evaporative cooling (DEC) was investigated with rigid media cellulose (RMC) pads and compared with that of wood straw pads. Face air velocity on pads was varied between 0.5 and 3.0 m·s-1. The time change of ambient air dry-and wet-bulb temperatures, water temperature, and outlet air dry-bulb temperature were measured. For cellulosic pad, the experimental data showed that the saturation efficiency reached 71% of its steady state value in the first 100 seconds of operation and the final steady state value was reached after 600 seconds. The saturation efficiency decreases with the increase in the air velocity. It could be shown that the DEC is more efficient with wood straw pads compared to RMC pads. Predicted data using the published literature underestimated the saturation efficiency of DEC by about 18%.


Article
FORMATION OF NI-SB PHASES BY ELECTRO-CODEPOSITION DIFFUSION COATING
تكوين أطوار Ni-Sb بطريقة الترسيب الكهربائي _ الانتشاري للطلاء

Loading...
Loading...
Abstract

Electrodeposited metal matrix/metal particle composite coatings (EMMC’s) were deposited, heat treated and characterized. Nickel matrix/ antimony particulate coatings deposited on Inconel 600 substrate (Ni-base superalloy) was chosen as a model system. The microstructure of the plated and heat treated coatings was characterized using light optical microscope (LOM) and X-ray diffraction analysis (XRD).Results showed that Ni5Sb2, Ni3Sb, and NiSb phases are presented in the coated layer. Further NiSb is a good source for Sb2O4 compound formation under open heating. This oxide has good stability at high temperatures.

تم في هذا البحث إجراء ترسيب كهربائي مزدوج لأرضية معدنية / دقائق معدنية وهذا ما يصطلح عليه ( EMMC’s ) ثم تلى ذلك إجراء معاملة حرارية . حيث تم ترسيب أرضية نيكل / دقائق الانتيمون على سطح سبيكة الانكونيل 600 وهي احد أنواع السبائك الفائقة ذات أساس نيكل والتي تتمتع باستخدامات واسعة وقد تم تحديد التركيب المجهري لطبقة الطلاء المعالجة حرارياً باستخدام المجهر الضوئي ، حيود الأشعة السينية .أظهرت النتائج تكون الأطوار NiSb, Ni3Sb, Ni5Sb2 عند سطح الطلاء. كما بينت النتائج إن طور NiSb مصدر جيد لتكوين Sb2O4 عند تسخينه في الهواء. هذا الأوكسيد يتمتع باستقرارية جيدة عند درجات الحرارة المرتفعة.

Listing 1 - 9 of 9
Sort by
Narrow your search

Resource type

article (9)


Language

English (7)

Arabic and English (2)


Year
From To Submit

2017 (1)

2016 (1)

2015 (1)

2013 (3)

2009 (2)

More...