research centers


Search results: Found 6

Listing 1 - 6 of 6
Sort by

Article
Variation of Residual Chlorine Concentration in Some Regions of Al_Rassafa
تغاير تراكيز الكلور المتبقي في بعض مناطق الرصافة

Authors: Ahmad A. Rammadhan احمد عبدالله رمضان --- Kamal B. Nada كمال برزان ندا --- Ban A. Jassam
Journal: Iraqi Journal of Science المجلة العراقية للعلوم ISSN: 00672904/23121637 Year: 2016 Volume: 57 Issue: 2C Pages: 1436-1444
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

This study was done to examine the concentration of residual chlorine from different regions at AL Risafa side. The samples were collected from Baghdad AL- Jadida, Shareaa Phlistain, AL- Shaab and AL- Habibea, Al-Karrada, Al-Jadria, Al-Adamia at April-August/2013 .The Electrical Conductivity (Ec) and total dissolve solid (TDS), hang about its normal rate according to (WHO) but the Turbidity go beyond it’s limit to reach (11NTU) where the highest peak was recorded in Baghdad AL Jadida. The results show that chlorine concentration were decreased in the August compared with April because of high Temperature, and long in sun shine duration. It is found that there is inverse proportionality between residual chlorine and temperature. Same trend was found between residual chlorine and turbidity. The Conductivity and total dissolved solids of drinking water was within the permitted level according the Iraqi Standers (IQS, 2009).

اجريت هذه الدراسة لمعرفة تراكيز الكلور المتبقي في شبكة مياه الشرب في محطات مختارة من مناطق الرصافة . وقد تم جمع نماذج للمياه ومن مناطقها المختلفة، وتشمل بغداد الجديدة، وشارع فلسطين، والشعب، والحبيبية، الكرادة ، الاعظمية ، الجادرية في شهري نيسان واب لعام 2013. لقد حافظت معدلات نتائج التوصيلية الكهربائية(Ec) ، كمية الاملاح الذائبة (TDS) على الحدود المسموح بها بالمقارنة بمواصفات منظمة الصحة العالمية ( (WHO لعينات المياه، وأما بالنسبة للعكورة فقد تجاوزت الحدود السموح بها في بعض المحطات، إذ بلغت أعلى معدلاتها في منطقة بغداد الجديدة (11NTU) خلال فترة الدراسة. ولقد اشارت النتائج الى ان تراكيز الكلور في جمیع المحطات سجلت انخفاضا في شهر آب قیاسا لشهر نیسان بسبب ارتفاع درجات الحرارة وطول فتره التعرض الشمسي. وقد بينت الدراسة ان هناك تناسبا عكسيا بين درجة الحرارة وتراكيز الكلور المتبقي وكذلك فان تركيز الكلور المتبقي يتناسب عكسيا مع الكدرة. فيما كانت التوصيلية الكهربائية وكمية الاملاح الذائبة ضمن المواصفة القياسية العراقية، 2009.


Article
Quality of Pipe Water Supply in "Albu-Aitha" Rural Area of Baghdad
نوعية مياه الشرب في قرية البوعيثة الريفية

Author: Nafi A. O. Al-Ani د. نافع عويد العاني
Journal: IRAQI JOURNALOF COMMUNITY MEDICINE المجلة العراقية لطب المجتمع ISSN: 16845382 Year: 2010 Volume: 23 Issue: 4 Pages: 231-235
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

Abstract:Background: Water is essential for life, since it is used for public water supply, rural use, irrigation and industry. Preparing water for human consumption is a major industry and water is still a major environmental health problem in developing countries, where unsafe water is still responsible for water-born diseases in children in neonatal life and under age of 5 years old. In addition, concern is growing in developing countries about the health implications of a host of other contaminants particularly toxic chemicals.Objectives: The present survey in "Albu-Aitha" rural area attempts to assess the quality of pipe water supply in term of chlorination efficiency, bacteriological and chemical characteristics.Method: The village is supplied by three field water purification plants. A field survey was carried out during summer 2002. A total of 9 water samples were taken from each of the 3 plants, 3 were taken from inside the plant and the remaining 6 were taken 2 km. outside the plants in either directions (north and south). Chlorination efficiency measurement was done by chloroscope. A coliform bacilli bacterial count was done. Auto-analyzer and simple quantitative and qualitative analysis methods were used for chemical contamination. Atomic absorption and flame photometric technique methods were used for identification of toxic chemicals.Results: The range and mean concentration of the chemicals tested were all within the acceptable limits of the internationally reported reference values in the 3 water purification plants. No evidence of toxic chemical contamination was observed. The total dissolved salts (TDS) and the nitrates (NO3-) showed an obvious increase (although not significant statistically) in its mean value at the 2 Km distal point of measurement compared to its intra-plant value. Chlorination efficiency in Al-Naser plant ranged between 0.2 to 1.2 ppm and therefore was satisfactory. The other two plants showed ineffective chlorination. A statistically significant reduction in mean chlorine concentration was observed at the distal point (2 Km outside) compared to its intra-plant value in all the 3 plants. Bacteriological study showed a mean bacterial coliform count of around 5 / 100 ml in Om-Asapher and Old-Albu-Aitha plants, both inside and distally. Conclusion: The water consumed by Albu-Aitha population is of poor quality due to coliform bacterial contamination and may lead to detrimental effects on the health status of these people. The piping system used for distributing water from the 3 water purification plant is defective and may be responsible for organic and/or biologic contamination of pipe water. Chlorination is inefficient in 2 of the 3 examined plants.Key words: Water quality, chlorination efficiency, water purification plants, Iraq.

الملخصالخلفـية الأساسـية: ان الماء ضروري للحياة كونه يستخدم للاستهلاك العام وللمناطق الريفية والارواء وللمصانع. ان تحضير المياه للاستهلاك البشري يعتبر صناعة كبيرة في الدول النامية. ان الماء لايزال يشكل مشكلة صحية بيئية كبيرة في الدول النامية، حيث ان الماء الغير صالح للشرب لايزال مسؤولاً عن حدوث الامراض المنقولة عن طريق مياه الشرب عند الأطفال الرضع وتحت السنة الخامسة من العمر. اضافة الى ذلك فان الاهتمام في الدول النامية ينمو حالياً باتجاه التأثيرات الصحية السلبية للملوثات الأخرى وخاصة المواد الكيمياوية السامة.الأهــداف: ان الدراسة الحالية لمنطقة البوعيثة الريفية محاولة لتقييم نوعية تزويد مياه الشرب من خلال تقييم كفاءة التعقيم ومعرفة الصفات الجرثومية والكيمياوية.طريقة الدراسـة: ان القرية تتزود من ثلاثة مشاريع ميدانية لتنقية المياه. تم اجراء مسح ميداني خلال صيف عام 2002م. ان مجموع نماذج المياه التي تم أخذها وفحصها كانت (9) نماذج من كل مشروع من المشاريع الثلاثة. ثلاثة نماذج من داخل المشروع وستة نماذج الباقية أخذت بمسافة (2) كم خارج المشاريع ومن كلا الاتجاهين (شمالاً وجنوباً). ان قياس كفاءة التعقيم (الكلورة) جرى بواسطة جهاز الكلورؤسكوب. كذلك جرى تعداد عُصيات الكوليفورم. كذلك جرى استخدام طريقة التحليل الذاتي وطريقة التحليل الكمي والنوعي للملوثات الكيمياوية (الأيونات الموجبة والسالبة والعسرة ومجموع الأملاح المذابة).اجريت طريقة الامتصاص الذري وطريقة التحليل الطيفي للملوثات الكيمياوية السامة.النتائــج: مدى ومعدل تركيز المواد الكيمياوية التي تم اختبارها كانت قيمها جميعاً بالمستويات المقبولة عالمياً في كافة المشاريع الثلاثة. كذلك لم يلاحظ وجود مواد كيمياوية سامة. لوحظ زيادة ملحوظة في مجموع الاملاح المذابة (TDS) والنترات (NO3¯) بالرغم من كونها ليست لها قيمة معنوية احصائياً. من خلال ملاحظة معدل القيمة (2) كم خارج المشروع مقارنة بقياس القيمة داخل المشروع جدول (1). ان كفاءة التعقيم في مشروع النصر مقبولة حيث تراوحت بين (0.2-1.2) جزء من الكلور لكل مليون جزء من الماء. كما لوحظ في المشروعان الآخران عدم كفاءة التعقيم بحيث لوحظ انخفاض معنوي واحصائي في معدل تركيز التعقيم في النقطة البعيدة التي تصلها مياه المشروعان مقارنة بقيم كفاءة التعقيم في المشاريع الثلاثة. ان التحليل الجرثومي بين معدل تعداد عصيات الكوليفورم بحوالي (5) لكل 100 ملم لمشروعي أم العصافير والبوعيثة القديم وفي كلا الموقعين داخل المشروعان وفي النقاط البعيدة.الأستنتاج: ان الماء المستهلك للشرب من قبل مجتمع قرية البوعيثة ذو نوعية رديئة بسبب وجود التلوث بعصيات الكوليفورم والذي قد يؤدي الى تأثيرات سلبية للوضع الصحي في مجتمع القرية. ان نظام انابيب توزيع المياه المستخدم في المشاريع الثلاثة غير كفوء وربما يكون مسؤولاً في التلوث العصوي والاحيائي في شبكة مياه التوزيع. ان كفاءة التعقيم كانت غير كفوءة في مشروعين من الثلاثة مشاريع التي تم فحصها واختبارها.


Article
REUSE OF DOMESTIC WASTEWATER FOR IRRIGATION: CONCEPTUAL AND BASIC DESIGN ELEMENTS

Author: Abdul-Fattah Mohamed Ali
Journal: Iraqi Journal of Chemical and Petroleum Engineering المجلة العراقية للهندسة الكيمياوية وهندسة النفط ISSN: 19974884/E26180707 Year: 2011 Volume: 12 Issue: 1 Pages: 43 -52
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

In Iraq, water shortages and drought, especially during the hot summer months, necessitates that municipal authorities adopt water reuse projects like reusing treated domestic wastewater for crop irrigation. This work gives the conceptual and basic design elements for the necessary steps of filtration, UV irradiation and chlorination to make such a wastewater fit for agricultural use. A typical rural community of 50,000 people is considered as an example case for which functionality and relative simplicity of the proposed designs are prime factors. The objectives are 1) to show what is required and 2) that the presented information may be utilized to embark on the following phases of detailed design and execution of such projects.

ان شحة المياه والجفاف الذي يشهدهُ العراق , خصوصاً اثناء اشهر الصيف الحارة, تجعل من الضروري على السلطات البلدية اعتماد مشاريع اعادة استعمال المياه المصرفة المعالجة كمياه الصرف الصحي . يبين هذا العمل مفاهيم وعناصر التصميم الاساس لمراحل جعل هكذا مياه صالحة لسقي المزروعات. حيث تشتمل هذه المراحل على الترشيح والمعالجة بالاشعة فوق البنفسجية ومن ثم الكلورة. تم اعتماد تجمع سكاني ريفي عدد نفوسه 50000 كمثال لتوضيح التصاميم المقترحة المتسمة بالبساطة النسبية والفاعلية. يهدف العمل الى 1) ايضاح المتطلبات و 2) الأفادة من المعلومات المقدمة للشروع بطوري التصاميم التفصيلية والتنفيذ لهذه المشاريع.


Article
Concentration of Residual Chlorine in Tikrit University Water Supply Network
تراكيز الكلور المتبقي في شبكة ماء جامعة تكريت

Author: عفاف جدعان عبيد
Journal: Iraqi Journal of Civil Engineering المجلة العراقية للهندسة المدنية ISSN: 19927428 Year: 2011 Volume: 7 Issue: 1 Pages: 18-29
Publisher: University of Anbar جامعة الانبار

Loading...
Loading...
Abstract

Chlorine is considered as one of the most important disinfectants because of its availabilityin a wide form and in acceptable cost. Measurements of residual chlorine are very essential toassure the presence of disinfection at various locations of the water distribution system. Theaim of the present work is to find the residual chlorine concentrations in potable water whichleaves Tikrit University water supply plants. pH-, water temperature and water turbidity arealso measured. Sixty samples of tap water are tested during November 2009 till April 2010.The results show that range of residual chlorine is 0.2-4mg/l) and most of the measured valuesare higher than the maximum permissible limit according to Iraqi standards( 417/1974 )The data indicated that pH is within the range of (7-8.2) and there is no clear relationshipbetween pH and residual chlorine concentration. It is found that there an inverseproportionality between residual chlorinean and temperature . Same trend is found between residual chlorine and turbitiy. The Conductivity and total dissolved solid of drinking water waswithin the permitted level by the Iraqi standers

يعتبر الكلور من أهم المعقمات لتوفره بصورة واسعة وبكلفة معتدلة في اغلب مناطق العالم. ان وجود الكلور في مختلف مناطق شبكات الاسالة مهمجدا للتاكد من وجود التعقيم للمياه. يهدف البحث إلى إيجاد تركيز الكلور المتبقي في الماء الخارج من محطة إسالة ماء جامعة تكريت وبعض المناطق التابعة لهاضمن جامعة تكريت وملحقاتها.اختيرت هذه المناطق على مسافات مختلفة من المحطة وذلك لمعرفة وجود الكلور المتبقي في مياه الشرب ضمن الحدود المسموحة.ودرجة حرارة الماء والعكورة لستين عينة من ماء الشرب pH تم قياس تركيز الكلور المتبقي وكذلك قيم بعض العوامل المؤثرة ع ليه مثل الدالة الحامضية. خلال فترة الدراسة التي امتدت بين شهري تشرين الثاني ٢٠٠٩ الى نيسان ٢٠١٠٤ ملغرام/ لتر. ان معظم تراكيز - تم استعمال نماذج إحصائية لتحليل البيانات حيث بينت النتائج ان تركيز الكلور المتبقي تراوح بين ٠٫٢- فقد تراوحت بين ٧ pH الكلور المتبقي كانت اعلى من القيم المسموح بها وفق المعايير القياسية لمياه الشرب العراقية. اما بالنسبة لقيم الدالة الحامضية٨٫٢ واظهرت ا لنتائج عدم وجود علاقة واضحة بين هذه القيم وتركيز الكلور المتبقي. كذلك اشارت النتائج ان هناك تناسبا عكسيا بين درجة الحرارة وترك يزالكلور المتبقي وكذلك تناسب تركيز الكلور عكسيا مع الكدرة. أما بالنسبة للتوصيلية الكهربائية والاملاح الذائبة الكلية فقد كانت ضمن حدودالمواصفات القياسية العراقية.


Article
Evaluation of some Limiting Factors affecting Water chlorination at Baghdad / Al-Kurch District
دراسة بعض العوامل المؤثرةعلى كفاءة الكلورالتطهيرية لماء الشرب فى محطات التصفية لمدينة بغداد الكرخ

Authors: Najim Hadi Najim نجم هادي نجم --- Rebwar Tahir Aziz ريبوار طاهر عزيز
Journal: The Iraqi Journal of Veterinary Medicine المجلة الطبية البيطرية العراقية ISSN: 16095693 Year: 2012 Volume: 36 Issue: 1 Pages: 43-49
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

This study was designed to high light about the effect of some factors individually or in combination that shared in the reduction of the chlorine activity and efficiency for meeting the bacterial standards as a disinfection agent for drinking water at Baghdad city/ Al- kurch. To achieve the objectives (137) drinking water samples were collected from July up to the end of November 2007 from the houses of Baghdad's citizens/ Al- kurch. Also studying the scientific nature of some municipal water supply at Baghdad/ Al- kurch, drinking water samples were collected from faucets after allowing the water to run for 0, 5 and 10 minutes. Statistical data showed that there was non significant difference in both the chlorine concentration and coliform counts in all samples that were taken after allowing the water to run for 0, 5 and 10 minutes and for that reason drinking water samples after allowing the water to run for 5 minutes were chosen as the best time for sampling in this research. Data revealed that the free chlorine in drinking water was below the standards set by the World Health Organization (WHO) in the period from July up to the end of August 2007, whereas the highest Coliform counts in drinking water were established during the above mentioned months, while the coliform counts decreased in the period from September up to the end of November 2007 due to the utilization of higher concentrations of total chlorine in drinking water in municipal water supply, in addition to that, the effect of some variables such as quantity of free chlorine, temperature, pH and oxidation- reduction potential of water on the sanitizing efficiency of the chlorine were studied. The statistical data revealed that there was a significant negative correlation (P < 0.01, r = -0.072) between the chlorine sanitizing efficiency with both the concentration of the free chlorine and its contact time with microorganisms while the effect of temperature, pH and oxidation- reduction potential of water showed non significant effect on the chlorine sanitizing efficiency. In order to evaluate the sanitation program of the municipal water supply at Baghdad/ Al- kurch to ensure that the water treatment was being done properly by the employees and meeting the bacterial standards set by (WHO). All the official documents about the chlorine concentration, pH, temperature of water that were reported by the employees in the period from July up to the end of November 2007 were studied and compared to this results, for that reason 16 drinking water samples from the municipal water supply were collected and tested for the above mentioned parameters during November using the most sensitive advanced digital instrument (Chlorimeter). Data reported by the municipal water supply at Baghdad/ Al- kurch revealed that chlorine, pH and temperature of water were 3.6 PPM, 7.50 and 21.7Co, respectively in November only. While the measurements were reported here 5.05 PPM, 6.94 and 17.6oC respectively, during the same month by using the Chlorimeter and the only reason for such differences with our results was due to the use of a highly sensitive digital instrument by our research in comparison to the old methods and instruments that were used in the municipal water supply.

صممت هذه التجربة لدراسة العوامل التي يمكن ان تؤثر على كفاءة الكلور التطهيرية منفردة او مجتمعة مع بعضها وتأثير ذلك على المستوى القياسي والصحي لمياه الشرب لمدينة بغداد/ الكرخ، حيث جمعت 137 عينة ماء خلال الدراسة (تموز- تشرين الثاني 2007) من مساكن المواطنين في مناطق مختلفة لمدينة بغداد/ الكرخ، ولغرض توحيد وقت جمع نماذج الماء من حنفيات بيوت المستهلكين (بعد فتح الحنفية)، تم اختيار ثلاث اوقات (0، 5، 10 دقائق) من جريان الماء من الحنفية ومن خلال التحليل الاحصائي للنتائج استنتج بعدم وجود فروقات معنوية مهمة من الناحية الاحصائية (0.05 > P) بين قيم تركيز الكلور والعد الجرثومي الاكثر احتمالاً المسجلة في عينات ماء الشرب للاوقات 0، 5، 10 دقائق، واختير الوقت 5 دقائق كحل وسط لاكمال البحث على جميع العينات . ومن خلال تحليل نتائج الدراسة الخاصة بالمسح الميداني لبيوت المستهلكين اتضح بان تركيز الكلور الحر في مياه الشرب عند المستهلك كان دون المستوى الصحي الموصى به من قبل منظمة الصحة العالمية خلال الشهرين الاوليين من الدراسة (تموز وآب) مما اثر سلباً على المستوى الصحي للماء، حيث سجلت اعلى قيم للعد الجرثومي الاكثر احتمالاً خلال تلك المدة، في حين انخفضت هذه القيم في الاشهر الثلاثة الاخيرة من الدراسة (ايلول، تشرين الاول وتشرين الثاني) بسبب زيادة تركيز الكلور الكلي في محطات تصفية الماء مما انعكس ايجاباً على تركيز الكلور الحر لدى المستهلك وتحسن المستوى الصحي القياسي للمستويات المقبولة عالمياً. كذلك درست بعض العوامل المؤثرة على كفاءة الكلور التطهيرية والتي اشتملت على كل من تركيز الكلور الحر في ماء الشرب ودرجة حرارة الماء والاس الهيدروجيني للماء وجهد الاكسدة والاختزال وعلاقة تلك العوامل مع بعضها ومن خلال التحليل الاحصائي للنتائج وجدت علاقة عكسية (r= -0.72; P<0.01) بين كفاءة الكلور التطهيرية وكل من تركيز الكلور الحر ووقت تماس الاحياء المجهرية مع الكلور، اما العوامل الاخرى فكان تأثيرها محدود او معدوم لانها تقع ضمن القياسات الموصى بها. ولغرض التعرف على واقع عمل محطات تصفية المياه لمدينة بغداد/ الكرخ والقياسات المعتمدة في تلك المحطات ومدى مطابقة ذلك للمواصفات القياسية، اعتمدت السجلات الرسمية لتلك المحطات لاسيما المدة الواقعة بين شهر تموز الى تشرين الثاني 2007، حيث سجلت قيم كل من تركيز الكلور الكلي والاس الهيدروجيني ودرجة حرارة الماء، حيث جمعت 16 عينة ماء خلال شهر تشرين الثاني وسجلت قيم نفس القياسات المشار اليها ولكن باستخدام الاجهزة الرقمية الحديثة التي استخدمت في المسح الميداني الاولي، وبعد تحليل نتائج قيم القياسات المعتمدة من سجلات المحطات اتضح بان معدل قيم تركيز الكلور الكلي في شهر تشرين الثاني كان 3.6 جزء بالمليون، في حين كان معدل قيم الاس الهيدروجيني للمدة نفسها 7.5، اما معدل قيم درجة الحرارة للمدة نفسها بلغ 21.7 مo وبالمقارنة مع معدلات قيم تلك القياسات والمأخوذة بالاجهزة الحديثة حيث كان معدل تركيز الكلور الحر في شهر تشرين الثاني 5.05 جزء بالمليون ومعدل قيم الاس الهيدروجيني 6.94 ومعدل درجة حرارة الماء 17.6 مْ , حيث اتضح وجود فروقات في قراءات تلك القيم. والسبب في ذلك يعود الى استخدام الباحث اجهزة رقمية حديثة وحساسة بالمقارنة مع الطريقة المستخدمة في تلك المحطات والتي تعتمد على العامل البشري في قراءة النتائج.


Article
Catalytic regioselective chlorination of phenols in the presence of polysulfide polymer containing 1, 3, 4-thiadiazole unit
الكلورة الانتقائية للفينولات باستخدام عوامل مساعدة من بوليمرات السلفايد التي تحتوي على وحدة 1, 3, 4-ثايودايزول.

Author: Ali Jassim. Al-Zuhairi
Journal: journal of kerbala university مجلة جامعة كربلاء ISSN: 18130410 Year: 2014 Volume: 12 Issue: 4 Pages: 228-237
Publisher: Kerbala University جامعة كربلاء

Loading...
Loading...
Abstract

Polymeric sulfides containing 1, 3, 4-thiadiazole unit with different spacer group length have been synthesized and established to be useful catalysts for the chlorination of phenol, o-cresol, m-cresol and m-xylenol using freshly distilled sulfuryl chloride in the presence of Lewis acid as a co-catalyst at room temperature. The yields of para-isomers and para/ortho ratios were higher compared to cases where no catalyst was used with most catalysts for most phenols even when a very low concentration of poly sulfide was used.

تم تحضير بوليمرات السلفايد التي تحتوي على مجموعة 1, 3, 4-ثايا دايازول وكذلك مجاميع الكايل مختلفة. تم استخدام البوليمرات المحضرة كعوامل مساعدة في عملية كلورة الفينول و اورثو- كريسول و ميتا- كريسول وكذلك ميتا- زايلينول باستخدام كلوريد سلفوريل وبوجود حامض لويس كعامل مساعد. ان حصيلة الكلورة في موقع بارا وكذلك نسبة الاورثو الى البارا كانت عالية مقارنة بنتائج الكلورة في حالة عدم وجود العامل المساعد (البوليمر) لجميع انواع الفينولات المستخدمة حتى عند استخدام تراكيز ضئيلة من بوليمرات البولي سلفايد.

Listing 1 - 6 of 6
Sort by
Narrow your search

Resource type

article (6)


Language

English (4)

Arabic and English (1)


Year
From To Submit

2016 (1)

2014 (1)

2012 (1)

2011 (2)

2010 (1)