Performance of Alternative Refrigerant R431A on Air- Conditioning System under Real Transient Conditions
أداء المبرّدِ البديلِ آر 431 أي على منظومة تكييف الهواء تحت ظروف استجابة عابرة حقيقية

Author: Haider ali hussen
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2013 Volume: 31 Issue: 10 Part (A) Engineering Pages: 1962-1971
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

This paper presents the performances of new ozone-friendly refrigerant (R431a) in air-conditioning system were investigated experimentally and compared with R22 under transient conditions.R431a has no ozone depletion potential and very low greenhouse warming potential of less than 43 (ASHRAE Listed,2007)[1].The variation in refrigeration rate of evaporator, work consumption of compressor and heat rejection rate of condenser with time from the start to stop of the air condition system have been examined. Test results showed that the refrigeration rate of evaporator and heat rejection rate of condenser drops almost parallel to each other, both with a decreasing rate with time. The power consumption on the other hand does not increasing much. The coefficient of performance of R431a decreased from rang 8.96 to 9.28% through (5000 sec) at different ambient temperatures. The refrigeration rate of evaporator decreased by 2.69% through 5000 sec at ambient temperature 30 C° for R431a .The heat rejection rate of condenser decreased by 2.34% through 5000 sec at ambient temperature 30 C° for R431a. Results showed that the coefficient of performance of R431a is 14.67 to 20.34% higher than that of R22. Compressor input power of R431a is 8.39 to 14.19% lower than that of R22 at different ambient temperatures.

هذا البحث يقدم دراسة عملية لاداء منظومة تكييف الهواء باستخدام موائع تبريد جديدة R431a تحت ظروف استجابة عابرة حقيقية بالمقارنة مع الموائع القديمة R22.وسيط تبريد R431a لايؤثر على طبقة الاوزون وكذالك GWP اقل من 34.أظهرت النتائج العملية بان كمية الحرارة الممتصة من قبل المبخر وكمية الحرارة المطروحة من قبل المكثف تنخفض بشكل متوازي. لكن الطاقة المستهلكه من قبل الظاغط من جهة اخرى لا تزداد كثيرأ. معامل الأداء للغاز (R431a) تقل بنسبة 8.96-9.28% خلال 5000 ثانية عند درجاتِ الحرارة البيئيةِ المختلفةِ . كمية الحرارة الممتصة من قبل المبخر تقل بنسبة 2.69% خلال 5000 ثانية عند درجة الحرارة البيئيةِ 30 مئوية للغاز (R431a). كمية الحرارة المطروحة من قبل المكثف تقل بنسبة 2.34% خلال 5000 ثانية عند درجة الحرارة البيئيةِ 30 مئوية للغاز (R431a). معامل الأداء للغاز (R431a) هو أعلى بنسبة 14.67-20.34% بالمقارنه مع غاز(R22). وكذالك أقل أستهلاك للطاقه للغاز (R431a) بنسبة 8.39-14.19% بالمقارنه مع غاز(R22) عند درجاتِ الحرارة البيئيةِ المختلفةِ.


Article
Experimental Investigation for TiO2 nanoparticles as a Lubricant-Additive for a Compressor of Window Type Air-Conditioner System
تحقيق تجريبي للدقائق النانوية لاوكسيد التيتانيوم المضاف لمزيّت ضاغط مكيّفِ هواء نوعِ شباكي

Author: Haider ali hussen حيدر علي حسين
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2014 Volume: 20 Issue: 2 Pages: 61-72
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The coefficient of performance of a window type Air-Conditioner system can be improved if a reduction in the work of compressor can be achieved by a suitable technique. The present study investigates the effect of dispersing a low concentration of TiO2 nanoparticles in the mineral oil based lubricant, as well as on the overall performance of a window type Air-Conditioner system using R22 as the working fluid. An enhancement in the COP of the refrigeration system has been observed and the existence of an optimum volume fraction noticed, with low concentrations of nanoparticles suspended in the mineral oil. Results showed that the average compressor work reduced by 13.3%, which ultimately resulted in an increase of 11.99% in the COP due to the addition of nanoparticles in the lubricating oil.

معامل أداءِ نظامَ مكيّفِ هواء شباكي يُمْكِنُ أَنْ يُحَسّنَ إذا قل استهلاك عملِ الضاغطِ والذي يُمْكِنُ أَنْ يُنجَزَ مِن قِبل تقنية مناسبة. تَتحرّى الدراسةُ الحاليةُ تأثيرُ تركيز منخفض للدقائق النانوية لاوكسيد التيتانيوم في الزيت المعدني ، بالإضافة إلى الأداءِ العامِّ بإستعمال نظامِ مكيّفِ هواء ذو مائع تبريد R22. لوحظَ تحسين في معامل اداء النظامِ التبريدَ و لوحظَ ان الكسر الحجمي المثالي كان عند تراكيز واطئة من الدقائق النانوية في الزيت المعدني. . اظهرت نَتائِجَ الإختبارِ بأنّ معدل عملَ الضاغطِ خفّضَ الى 13.3 %، الذي أدّى إلى زيادةِ في النهاية 11.99 % في معامل اداء بسبب إضافةِ دقائق نانوية في الَزْيت.


Article
Experimental investigation of vapor compression refrigeration system performance using Nano-refrigerant
استقصاء تجريبي لأداء منظومة تبريد انضغاطيه باستخدام وسيط تبريد نانوي

Author: Ahmed J. Hamad أحمد جاسم حمد
Journal: Wasit Journal of Engineering Sciences مجلة واسط للعلوم الهندسية ISSN: 23056932 Year: 2014 Volume: 2 Issue: 2 Pages: 12-27
Publisher: Wassit University جامعة واسط

Loading...
Loading...
Abstract

Experimental investigation of vapor compression refrigeration system performance using Nano-refrigerant is presented in this work. Nano-refrigerant was prepared in current work by mixing 50 nanometers diameter of copper oxide CuO nanoparticles with Polyolester lubrication oil and added to the compressor of the refrigeration system to be mixed with pure refrigerant R-134a during its circulation through refrigeration system. Three concentrations (0.1%, 0.25%, and 0.4%) of CuO-R134 a Nano-refrigerant are used to study the performance of the refrigeration system test rig and to investigate the effect of using Nano-refrigerant as a working fluid compared with pure refrigerant R-134a. The results showed that, the increasing in concentration of CuO nanoparticles in the Nano-refrigerant will significantly enhance the performance of the refrigeration system, as adding nanoparticles will increase the thermal conductivity, heat transfer and improve the thermo-physical properties of Nano-refrigerant. Investigation of performance parameters for refrigeration system using Nano-refrigerant with 0.4% concentration compared with that for pure refrigerant R-134a shows that, Nano-refrigerant has reflect higher performance in range of 10% and 1.5% increase in COP and refrigeration effect respectively and 7% reduction in power consumption for refrigeration system. It can be concluded that, Nano-refrigerants can be efficiently and economically feasible to be used in the vapor compression refrigeration systems.

يقدم هذا البحث استقصاء تجريبي لأداء منظومة تبريد انضغاطيه باستخدام وسيط تبريد نانوي. تم تحضير وسيط التبريد النانوي خلال العمل الحالي بخلط جسيمات نانوية من اوكسيد النحاس (CuO) بقطر 50 نانومتر مع زيت التشحيم بوليليستر لمنظومة التبريد وأضيف الى ضاغط المنظومة حيث يخلط مع وسيط التبريد R-134a عندما ’يضغط خلال اجزاء منظومة التبريد. تم تحضير واستخدام وسيط تبريد نانوي بثلاثة تراكيز (0.4% , 0.25% , 0.1%) من CuO-R134a لدراسة اداء محطة فحص لمنظومة تبريد انضغاطيه ولاستقصاء تأثير استخدام وسيط تبريد نانوي كمائع عامل مقارنة مع وسيط التبريد R-134a . أظهرت النتائج , أن زيادة تركيز الجسيمات النانوية لأوكسيد النحاس في وسيط التبريد النانوي سوف تحسن اداء منظومة التبريد الانضغاطية بشكل واضح لان اضافة هذه الجسيمات النانوية تؤدي الى زيادة الموصلية الحرارية وانتقال الحرارة وكذلك تحسن الميزات الفيزيائية – الحرارية لوسيط التبريد النانوي. استقصاء معلمات الاداء لمنظومة التبريد الانضغاطية باستخدام وسيط تبريد نانوي بتركيز (0.4%) مقارنة مع وسيط التبريد R-134aأظهر بأن وسيط التبريد النانوي قد أعطى اداء افضل من خلال زيادة قيم معامل الاداء وتأثير التبريد بحدود 10% و 1.5% على التوالي مع تخفيض 7% من استهلاك القدرة الكهربائية لمنظومة التبريد. يمكن الاستنتاج بان وسائط التبريد النانوية تعتبر مجدية اقتصاديا وكفؤة اذا ما استخدمت في منظومات التبريد الانضغاطية.


Article
Performance Augmenting of a Vertical Axis Wind Turbine using Adaptable Convergent Ducting System
تعزيز أداء التوربين الريحي عمودي محور الادارة باستخدام منظومة معبر هواء تقاربي

Authors: Abdullateef A. Jadallah عبد اللطيف أحمد جاد الله --- Sahar R. Farag سحر راضي فرج --- Jinan D. Hamdi جنان دخيل حمدي
Journal: Al-Khwarizmi Engineering Journal مجلة الخوارزمي الهندسية ISSN: 18181171 23120789 Year: 2018 Volume: 14 Issue: 3 Pages: 141-148
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Developments are carried out to enhance the performance of vertical axis wind turbines (VAWT). This paper studies the performance of the ducted wind turbine with convergent duct (DAWT). Basically, the duct technique is utilized to provide the desired wind velocity facing the turbine. Methodology was developed to estimate the decisive performance parameter and to present the effect of the convergent duct with different inlet angles. The ducted wind turbine was analyzed and simulated using MATLAB software and numerically using ANSYS-Fluent 17.2. Result of both approaches were presented and showed good closeness for the two cases of covering angles 12° and 20°, respectively. Results also showed that the convergent duct with an inlet angle 12° and 20° improved the coefficient of performance at a specified tip speed ratio by 25.8% and 33.33% respectively in the productivity of wind turbine.

أجريت دراسات عديدة لتحسين اداء التوربين الريحي العمودي. تناول هذا البحث دراسة تحسين اداء التوربين الريحي عمودي محور الادارة باستخدام معبر هوائي تقاربي. تم تطويع منهجية رياضية تحليلية وعددية باستخدام ANSYS 17.2 لتمكين حساب معامل القدرة والعزم والمتغيرات الحاكمة الاخرى باستخدام زاويتين لمعبر الهواء وبواقع 12ه و 20ه . ان استخدام المعبر بالزاويتين المذكورتين آنفا حقق زيادة في معامل القدرة بواقع 25.8% و 33.33% على التوالي. تم تمثيل تصرف الجريان وحساب معامل القدرة من الحل العددي ومقارنته بنتائج الحل التحليلي واظرهت تطابقا جيدا.


Article
Enhancement the Performance of Condenser of Split Type Air Conditioning System by Using Evaporative Cooling
تحسين أداء مكثف منظومة تبريد نوع سبلت باستخدام تبريد تبخيري

Author: Lina Ismail Jassim لينا إسماعيل جاسم
Journal: Al-Ma'mon College Journal مجلة كلية المامون ISSN: 19924453 Year: 2011 Issue: 17 Pages: 230-246
Publisher: AlMamon University College كلية المامون الجامعة

Loading...
Loading...
Abstract

The reduction of energy demand is a major concern in areas with very hot weather conditions about 50Co. This can be achieved by using more energy efficient equipment. Evaporative cooling provides a low cost, energy efficient and environmental friendly alternative to traditional Air Conditioning. In this study, a simple design of applying indirect evaporative cooling which investigated experimentally to improve the coefficient of performance of split unit and power consumption. This model consists of a cooling pad behind condenser and injected water on it to reduce air temperature before it passes over the condenser. The experimental results show that the coefficient of performance increases by about 73% and the power consumption decreases by about 18%.

يتضمن هذا البحث، تصميم نموذج عملي لتحسين اداء منظومة التبريد، والتقليل من استهلاك الطاقة الكهربائية خاصة في المناطق ذات الدرجة الحرارية العالية، والتي تصل إلى حوالي 50 درجة مئوية وذلك باستخدام التبريد التبخيري. ان النموذج المستخدم يتضمن وسيط تبريد تبخيري, وهو مادة الحلفة بشكل يشبه تصميم المكثف الخاص بالسبلت، موضوعة خلف المكثف لتبريد الهواء قبل مروره على ملف المكثف، وحوض ماء ومضخة صغيرة وانابيب توصيل الماء. علما ان النتائج العملية تشير الى زيادة في معامل اداء المنظومة بنسبة 73% وانخفاض باستهلاك الطاقة الكهربائية بنسبة 18%.


Article
Studying the Performance of Refrigeration Units Powered by Solar Panel

Authors: Venus Majeed Hameed فينوس مجيد حميد --- Maha Ali Hussein مها علي
Journal: Iraqi Journal of Chemical and Petroleum Engineering المجلة العراقية للهندسة الكيمياوية وهندسة النفط ISSN: 19974884/E26180707 Year: 2013 Volume: 14 Issue: 1 Pages: 39-46
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

An experimental study was conducted to determine the performance of a solar electric refrigeration system. The system contained flat photovoltaic solar panel which absorbs the solar energy and convert it to electrical energy, used to run the refrigeration cycle. Two refrigeration cycles with electrical solar panel were used over a period of 12 months, the first one with classical parts known in refrigeration cycle, while the second one introduced heat exchanger which improves the coefficient of performance by saving the consumed energy. The coefficient of performance of these refrigeration cycles with compressor efficiency 85% are 2.102 and 2.57 respectively. The overall efficiency of the two systems are 18.9% and 23.13%.


Article
Performance Enhancement of a Darrieus Vertical Axis Wind Turbine using Divergent Ducting System

Authors: Abdullateef A. Jadallah --- Sahar R. Farag --- Jinan D. Hamdi
Journal: Tikrit Journal of Engineering Sciences مجلة تكريت للعلوم الهندسية ISSN: 1813162X 23127589 Year: 2018 Volume: 25 Issue: 3 Pages: 58-66
Publisher: Tikrit University جامعة تكريت

Loading...
Loading...
Abstract

Ducting system is an effective way to potentially augment the performance of wind turbine for applications in building architectures. This paper is aimed to study one of the possible enhancement method of the vertical axis wind turbine performance. It is characterized by adding divergent duct to facilitate imparting more flow rate. The divergent duct was designed and adapted with wind turbine. The system was modelled and simulated analytically and numerically. A computer program built in MATLAB 16 to simulate the performance of system. The performance and flow are also solved numerically using ANSYS-FLUENT 17.2. Two opening angles of the divergent -duct were employed to study the behavior of air flow through divergent duct and results were compared with base vertical axis wind turbine. The duct turbine with a straight wall type diffuser demonstrate power coefficient augmentation by 24.2% and 9.09% for opening angle 20° and 12° respectively. The optimum half opening angle was attained for the diffuser. The diffuser’s length of a half of the throat opening is recommended, and its angle of opening is 20°. The diffuser was located in a stream-was direction that adequately aligned with the center of the vertical axis wind turbine. Results showed a reasonable influence on the performance of wind turbine. This technology may be used in gates and in urban areas with a relatively low wind speed regime.


Article
ManufacturingA Refrigeratorwith Heat Recovery Unit

Author: Mustafa Mohammed Kadhim
Journal: Journal of University of Babylon مجلة جامعة بابل ISSN: 19920652 23128135 Year: 2018 Volume: 26 Issue: 4 Pages: 104-123
Publisher: Babylon University جامعة بابل

Loading...
Loading...
Abstract

This study aims to exploite the rejected heating energy from condenser and benefit from it to reheat the foods and other materials.It can also be employed to improve the coefficient of performance of a refrigerator at the same time by using approximately the same consumption electrical energy used to operate the compressor and refrigerator in general. This idea has been implemented by manufacturing ofa refrigerator with using additional part has the same metal and condenser pipe diameters but its surface area does not exceed 40% from total surface area of the condenser and its design as an insulated cabinet from all sides to prevent heat leakage through it and located between the compressor and the condenser. Small electrical fan has been added inside this cabinet to provide a suitable air circulation and a homogenous temperature distribution inside the cabinet space. It is expected that the super heating energy of refrigerant (R134a) which comes out of the compressor would be removed inside this cabinet and this insist to condensate the refrigerant (cooling fluid) with a rate higher than that used in the normal refrigerator only. Three magnetic valves have been used in order to control the refrigerant flow in state of operation the refrigerator only or to gather with heating cabinet.To measure the temperatures at each process of the simple vapor compression refrigeration cycle, nine temperature sensors at input and output of each compressor, condenser and an evaporator in additional to input of cabinet and inside it and on evaporator surface have been provided. Five pressure gages have been used to measure the value of pressure and compare it for the two states of operation. The consumption of electrical energy can be calculated by adding an ammeter and a voltmeter and compare between the consumption energy of both states. The obtained results show that there is an improvement in thecoeffecient of performance in state of operation the refrigerator with heat recovery cabinet by 20% more than that of the operation of refrigerator only. This improvement is due to the reduction in the condenser exit temperature by 4 to 6 C˚, and the super heat removing process in reheating cabinet. The temperature of the cabinet reachs to 60 C˚ which is a sufficient for the food heating. A small amount of refrigerant pressure reduction due to these additions, and its effect on the preformace of the refrigerator may be not considerable.

يهدف هذا البحث الى إستثمار الطاقة الحرارية المفقودة من المكثف والإستفادة منها لغرض تسخين الأغذية والمواد الأخرى وكذلك تحسين معامل أداء الثلاجة في نفس الوقت بإستخدام تقريباً نفس الطاقة الكهربائية المستهلكة لتشغيل الضاغط والثلاجة بصورة عامة. تم تنفيذ هذه الفكرة من خلال تصنيع ثلاجة مع إظافة جزء إظافي يقع مابين الضاغط والمكثف و مكون من نفس معدن المكثف وله نفس قطر الأنابيب وبمساحة سطحية تبلغ حوالي 40% من المساحة الكلية للمكثف, كما أنه صُمم على شكل حاوية معزولة حرارياً لمنع فقدان الحرارة الى الخارج. تم تزويد هذه الحاوية بمروحة كهربائية صغيرة لتدوير الهواء داخلها وتوزيع الحرارة بشكل متجانس. لسيطرة على جريان مائع التبريد R134a تم أستعمال ثلاثة صمامات مغناطيسية لتشغيل الثلاجة وحدها أو مع كابينة التسخين, ولقياس درجة الحرارة عند كل نقطة في دورة التبريد تم إظافة تسع متحسسات لقياس درجة الحرارة عند مدخل ومخرج كل من الضاغط والمكثف والمُبخر وكذلك كابينة التسخين, كما تم إظافة خمسة مقاييس للضغط للمقارنة بين حالتين التشغيل. الطاقة الكهربائية المستهلكة تُقاس من خلال أستخدام مقياس التيار والفولتية. بينت النتائج المستحصلة الى ان هنالك تحسن في معامل الأداء بنسبة 20% في حالة أستخدام كابينة التسخين, حيث ان هذا التحسن ناتج عن إنخفاض درجة حرارة مائع التبريد الخارج من المُكثف بمقدار 4 إلى 6 م˚ وكذلك إزالة حرارة التحميص داخل كابينة التسخين التي تبلغ درجة الحرارة داخلها حوالي 60 م˚. تم ملاحظ نقصان قليل في ضغط مائع التبريد وهذا لايؤثر على أداء الثلاجة.


Article
اثر معامل الاداء في النتاج المعماري

Authors: حسام جبار عباس --- أبراهيم جواد كاظم ال يوسف
Journal: Journal of University of Babylon مجلة جامعة بابل ISSN: 19920652 23128135 Year: 2018 Volume: 26 Issue: 10 Pages: 134-149
Publisher: Babylon University جامعة بابل

Loading...
Loading...
Abstract

If the procedural definition of the performance act is ("the mixing of subjective and objective effort in a logical and conscious action to reflect the architectural thought and create the optimal expression between the desired image and the possible image with references from inside or outside the architecture to meet the need of the receiver and thus accept).Is this dimension performative specific performance coefficient can be measured by the performance of architecture through which, if we know that the definition of coefficient of performance ((is the energy required relative to the paid energy)) and the relationship of these two definitions, an architectural concept of performance evaluation, which is a system that helps in measuring and evaluating the relationship between the efficiency of the performance duties and functions of the job Eshetglha and all of the behavior and the ability of the product on the best results achieved performance according to the level of performance and the degree of actual achievement, which helps to know the strengths and weaknesses of the past performance and determine how to avoid weaknesses and investment strengths at the present time and in the pain Will be accepted to reach the highest degree of performance efficiency, including the individual and the community. If the objective of architecture core is the benefit of man all the physical, moral, social and economic levels ... etc., since this science dimension Adaiaa goal of the benefit of man and therefore society finds research his problem through the questions, you can find a constant coefficient of performance architecture can be measured? How to take advantage of the performance coefficient can be used as a criterion for measuring the benefit of architecture, and what is the relationship between the benefit of the production and function of the architecture, what specializes performance output coefficient or usefulness of the function of architectural production. This gives the signal to determine the main hypothesis that architecture science goal is to find the function of the product of working on the benefit of the human system and this system consists of a set of elements and through the study of these elements and their relationships can be reached Adaiatha plants. Whereas the secondary hypothesis: the possibility of finding for the benefit of architectural output function for performing access to read in the life of architecture through the elements of its projects components and can therefore be life indicator architectural output and ensure the preservation of Adaiatha.In this case, it is possible to refer the information base to the search through the variable used in the coefficient of performance of the architectural output symbolized by the symbol X and the theoretical objectives of the research in the possibility of knowing, containing and directing the change in the nature of the performance awareness of the benefit of a particular architectural product by knowing its practical function in providing a method of measurement Which enables them to identify a new relationship and a new life in architecture that depends mainly on the performance factor of the architectural output and its relation to elements of the architectural system to reach a building that is full of life and as long as possible. Independent variables: the components of the performance of the architectural production of energy production, required and paid and its impact on the life of architecture. The research was based on a methodology that consisted of the following axes: the axis of the efficiency of performance, the role of the mind and its transfer to its own, and the focus of the study examples and conclusions and recommendations.

اذا كان التعريف الاجرائي للفعل الادائي هو) امتزاج الجهد الذاتي والموضوعي في فعل منطقي واعي لتجسيد فكر معماري وخلق التعبير الامثل بين الصورة المرجوة والصورة الممكنة بمراجع من داخل العمارة أو خارجها وبما يحقق حاجة المتلقي وبالتالي قبولة).[1] فهل لهذا البعد الادائي معامل اداء معين يمكن قياس اداء العمارة من خلاله اذا علمنا أنتعريف معامل الاداء (هو نسبة الطاقة المطلوبة إلى الطاقة المدفوعة([2]وما علاقة هذين التعريفين معمارياً بمفهوم )تقويم الاداء( الذي يعتبر النظام الذي يساعد في قياس وتقويم العلاقة بين كفاءة الاداء لواجبات ومهام الوظيفة التي يشتغلها وكل من سلوك ومقدرة المنتجعلى الاداء الافضل والنتائج المتحققة طبقا لمستوى الاداء ودرجة الانجاز الفعلية مما يساعد على معرفة جوانب القوة والضعف في الاداء الماضي وتحديد كيف يمكن تجنب جوانب الضعف واستثمار جوانب القوة في الوقت الحالي وفي المستقبل للوصول إلى اعلى درجة كفاءة الاداء بما يعود على الفرد والمنشا والمجتمع. [3]وإذا كان هدف العمارة الاساسي هو منفعة الانسان على كافة المستويات المادية والمعنوية والاجتماعية والاقتصادية ...الخ، وبما أن لهذا العلم بعدا ادائيا هدفه منفعة الانسان وبالتالي المجتمع يجد البحث مشكلته من خلال الاسئلة، هل يمكن ايجاد معامل ثابت للأداء المعماري يمكن قياسه؟ كيف يمكن الاستفادة من معامل الاداء كمعيار يمكن استخدامه في قياس منفعة العمارة،وما هي العلاقة بين منفعة النتاج ووظيفته فيالعمارة، بماذا يتخصص معامل الاداء بمنفعة النتاج ام بوظيفة النتاج المعماري. وهذا يعطي الاشارة إلى تحديد الفرضية الرئيسية في أن العمارة علم هدفه ايجاد وظيفة للنتاج تعمل على منفعة الانسان بنظام وهذا النظام مكون من مجموعة من العناصر ومن خلال دراسة هذه العناصر وعلاقاتها يمكن الوصول إلى معامل ادائيتها. بينما تكونالفرضية الثانوية في:إمكانية ايجاد دالة الادائية لمنفعة النتاج المعماري للوصولإلى قراءة في حياة العمارة من خلال عناصر مكونات مشاريعها وبالتالي يمكن أن يكون مؤشر لعمر النتاج المعمارية وضمان الحفاظ على ادائيتها. وهنا يمكن تأشير القاعدة المعلوماتية للبحث من خلال المتغير المعتمد في: معامل ادائية النتاج المعماري ويرمز له بالرمز (X)وتحديد أهداف البحث نظرياً في إمكانية معرفة واحتواء وتوجيه التغير في طبيعة ادراك ادائية منفعة نتاج معماري معين من خلال معرفة دالة ادائيته عملياً في توفير طريقة قياس علمية يمكن منها التعرف على علاقة وخاصية جديدة للحياة في العمارة تعتمد وبشكل اساسي على معامل ادائية النتاج المعماري وعلاقته بعناصر النظام المعماري للوصول إلى عمارة مفعمة بالحياة وباطول عمر ممكن. المتغيرات المستقلة:المتمثلة بالعناصر المكونة لادائية النتاج المعماريلانتاجالطاقة، المطلوبة والمدفوعة ومدى تاثيرها على حياة العمارة. وقد إعتمد البحث على منهجية تمثلت في المحاور التالية: محور تضمن كفاءة الاداء، ودور العقل وإنتقاله إلى ذاتيته، ومحور أمثلة الدراسة وأستنتاجات وتوصيات.


Article
Effect of Using Air Guide Net in Front of the Condenser on the Performance of Automobile Air Conditioning System
تأثير استعمال شبكة موجة الهواء امام المكثف على اداء منظومة تبريد السيارات

Authors: Mahmoud Maustafa Mahdi محمود مصطفى مهدي --- A. A. Gaddoa أمير عبد جدوع
Journal: Al-Khwarizmi Engineering Journal مجلة الخوارزمي الهندسية ISSN: 18181171 23120789 Year: 2019 Volume: 15 Issue: 2 Pages: 89-99
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The work of this paper is an investigation to improve the condenser performance of the automobile air conditioning system by enhancing the air-side heat transfer from the condenser through the use of an air guide net installed in front of the condenser face which is basically an aluminum plate having a circular entrance shape for the air passage. The A/C system was examined under two types of test. The first test was conducted the air guide net, while the second was done with the air guide net. The performances of the A/C system under these tests were compared. For the second type of test, the experiment was carried out with three different size of air guide net, three different circular diameters (2, 3 and 3.5 cm) and a common air passage area. The effect of varying the size of the air guide net and its inclination angle was investigated. The experimental work included five inclination angles (0o, 5o, 10o, 15o and 20o). It was found that the presence of the air guide net caused an improvement in the performance of the A/C system for all sizes and inclination angles. In addition, the electrical energy consumed by the A/C system without the air guide net was calculated and compared to those obtained for the A/C system with the air guide net. The results manifested that the reduction of the power consumption was enhanced by operating the A/C system with the air guide net.

في هذا البحث تم التركيز على تحسين أداء المكثف لمنظومة تبريد السيارة من خلال تحسين انتقال الحرارة الهوائي وذلك باستعمال شبكة موجة هواء وضعت أمام وجه المكثف. أن شبكة موجه الهواء تحتوي على فتحات لمرور الهواء ذات شكل دائري أن هذه الفتحات الدائرية يمكن تغير أقطارها وبذلك يمكن دراسة تأثير تغير حجم هذه الفتحات على أداء المنظومة. في هذا العمل تم اختيار الأداء لمنظومة التبريد عملياً حيث فحصت المنظومة تحت نوعين من الاختبارات .النوع الأول بدون وضع شبكة موجه الهواء , والثانية مع وضع شبكة موجه الهواء أمام وجه المكثف , تم مقارنة أداء المنظومة لهذين النوعين من الاختبارات من خلال معامل أداء الدورة ومقدار الطاقة المصروفة بالدورة بالنسبة للنوع الثاني من الاختبارات , فأن التجارب العملية تضمن ثلاثة أحجام من شبكة موجه الهواء أي ثلاثة أقطار لمرور الهواء ( 2 , 3 و 3.5 سم) مع بقاء مسافة دخول الهواء ثابتة لكل الأحجام .اعتماداً على التجارب العملية فقد تضمنت الدراسة تأثير تغير زاوية شبكة موجه الهواء على أداء المنظومة وبالتحديد للنوع الثاني من الاختبارات. وعليه فأن الجانب العملي تضمن دراسة تأثير خمس زوايا ميل (00 , 50 , 100 ,150 ,200 درجة) أن وجود شبكة موجه الهواء أمام وجه المكثف قد عمل على تحسين أداء منظومة التبريد وذلك لكل أحجام شبكة موجه الهواء فضلاً عن الى ذلك فأن مقدار الطاقة الكهربائية المستهلكة (المصروفة) من قبل منظومة التبريد وبدون استخدام شبكة موجه الهواء تم حسابها ثم مقارنتها مع منظومة التبريد ذات شبكة موجه الهواء. وبينت النتائج أن الانخفاض في الطاقة المصروفة قد تحسن عند تشغيل المنظومة مع شبكة موجه الهواء.