research centers


Search results: Found 22

Listing 1 - 10 of 22 << page
of 3
>>
Sort by

Article
INVESTIGATION THE EFFECT OF THE REACTIVEMUFFLER CONNECTIONS ON NOISE ATTENUATION
دراسة تأثير طرق الربط لكاتم الصوت التفاعلي على تخفيض الضوضاء

Author: Dr. Muna S. Kassim
Journal: Al-Qadisiyah Journal for Engineering Sciences مجلة القادسية للعلوم الهندسية ISSN: 19984456 Year: 2013 Volume: 6 Issue: 2 Pages: 177-192
Publisher: Al-Qadisiyah University جامعة القادسية

Loading...
Loading...
Abstract

A pollutant of concern to the mankind is the exhaust noise in the internal combustion engine. However this noise can be reduced sufficiently by means of a well designed muffler. The suitable design and development will help to reduce the noise level. The author design and fabricate a reactive muffler, spherical and cylinder shapes, afterward compared the noise level for these shapes with parallel and series connections. Transmission loss and transmission coefficient are calculated experimentally and theoretically for one, double and three mufflers in parallel and in series. Exhaust noise levels will aid the manufacturer in determining the correct muffler to meet the required noise reduction. These mufflers tested in frequency ranging between (50-600) Hz. In this study, the rustles show that the parallel connection is best than the series connection.

تزايد الاهتمام بضوضاء العادم في محرك الاحتراق الداخلي حيث ان هذه الضوضاء يمكن ان تقلل بما فيه الكفاية بواسطة كاتم الصوت لان التصميم المناسب وتطويره يساعدان على تقليل مستوى هذه الضوضاء. في هذه الدراسة تم تصميم وتصنيع كاتم تفاعلي كروي واسطواني الشكل حيث تم مقارنة مستوى الضوضاء لهذه الاشكال بربط التوازي والتوالي. خسارة الارسال (TL) ومعامل الارسال (TC) محسوبان بشكل تجريبي ونظري لكاتم واحد وثنائي وثلاثة كواتم بالتوالي والتوازي . مستويات ضوضاء العادم ستساعد في تقرير الكاتم الصحيح، هذه االكواتم اختبرت في تردد يتراوح ما بين (50-600) هيرتز . في هذه الدراسة اثبتت النتائج ان ربط التوازي للكاتم افضل من ربط التوالي.


Article
THE EFFECT OF GEOMETRICAL PARAMETERS OF CONNECTION ON CONNECTION BEHAVIOR AND STRESS DISTRIBUTION

Author: Dr. Abbass Z. Salman Dr.Saad T. Hamidi
Journal: Iraqi journal of mechanical and material engineering المجلة العراقية للهندسة الميكانيكية وهندسة المواد ISSN: 20761819 Year: 2010 Volume: 10 Issue: 2 Pages: 219-233
Publisher: Babylon University جامعة بابل

Loading...
Loading...
Abstract

In this paper the effect of connection geometric parameters on moment and stress distribution is reported. A comprehensive parametric analysis of steel beam-to-column connection using T-Stiffener is conducted to determine the connection behavior and stress distributions. A general-purpose finite element software, ANSYS is used to model the connection plate components with shell elements type 43. Whereas welds are modeled with linkage elements to reflect weld stiffness. The finite element mesh configurations are selected on the basis of h-refinement procedure. Geometric and material nonlinearities are incorporated in the analysis by adopting the modified Newton-Raphson technique and nonlinear stress-strain curve respectively. It is found that parameters describing the thickness of T-Stiffener web and flange plates and the ratio of beam flange width to T-Stiffener flange width have a significant effect on the connection behavior and stress distribution. Unlike conventional design assumptions, the applied moment is found to be almost equally distributed among the T-stiffener web and flange plates. Stress analysis shows that the moment capacity of a connection designed by the conventional method is limited to 43% of the beam allowable moment.

يتناول البحث دراسة تأثير الابعاد الهندسية واللحام على توزيع الاجهادات والعزوم على وصلة العتبة والعامود الفولاذي بأستخدام دعامة على شكل حرف (T) ً. وتم تمثيل الوصلة بطريقة العناصر المحددة بأستخدام برنامج التحليل الانشائي (ANSYS) حيث تم تمثيل الالواح المعدنية المكونة للوصلة باستخدام عناصر قشرية نوع 43 بينما تم تمثيل اللحام باستخدام عناصر خطية تتناسب جسائتها مع جساءة اللحام ، وتم ادخال التأثير اللاخطي للمادة والابعاد الهندسية في الحل وتبين ان سمك شفة وساق الدعامة وعرضها الى عرض شفة العتبة هي اكثر المتغيرات تأثيراً في توزيع الاجهادات بالوصلة، كما تبين ان العزوم المعرضة على الوصلة تتوزع بالتساوي على شفة وساق الدعامة على خلاف الفرض المستخدم في الطريقة التقليدية لتصميم الوصلة وظهر ان الوصلة المصممة بالطريقة التقليدية لا تتحمل اكثر من 43% من العزوم المسموح بها على العتبة.


Article
اتصـال النقيـض بالنقيـض في القـرآن الكريــم (دراســة دلالية)

Author: كاظم إبراهيم عبيس السلطاني
Journal: Journal of University of Babylon مجلة جامعة بابل ISSN: 19920652 23128135 Year: 2018 Volume: 26 Issue: 7 Pages: 364-376
Publisher: Babylon University جامعة بابل

Loading...
Loading...
Abstract

Favorite among Arabs, that they do not combine the two refutes in one sentence and the bug in that one invalidates the other and the contrary. And since the Holy Quran is a miracle book – sent in the language of the Arabs, and according to its methods in systems and expression – its verses come airtight, and not contradictory and do not contradict between them in the sense.It is an admirable Quranic regulation that God, Glory, Almighty, mentions the word and shows its characteristics, and then mentions its opposite in meaning and shows its characteristics as well as in the same verse or in other verses to join between them, contact the refutes of refutes. The contradiction in saying is that the speaker in a way that contradicts his meaning and dissents it.The difference between contradiction and antagonism is that, the antagonism is to incompatible the two articulation in the origin of existence. As for contradiction that the antagonism is to incompatible in the meaning, not in the origin.And the idea of contact contrast contrasted by Tabarsi (d. 548 e) in his book (Complex Bayan interpretation of the Koran) and we have proved this in the sheets of this research. The research divided five demands, and made the demands in which he stated the opposite of the contrast, to clarify the idea of the search for the recipient.

أُثر عن العرب أنَّها لا تجمع بين النقيضين في جملة واحدة والعلة في ذلك أنَّ احدهما يبطل معنى الاخر وينافيه. ولما كان القرآن الكريم كتاباً معجزاً – نزل بلغة العرب وعلى وفق اساليب كلامها نظماً وتعبيراً – جاءت آياته محكمة فلا تناقض ولا تنافي بينها في المعنى.ومن بديع النظم القرآني أنَّ الله سبحانه وتعالى يذكر اللفظ ويبين صفاته, ثُمَّ يذكر نقيضه في المعنى ويبين صفاته كذلك في الآية نفسها أو في آيات أُخر فيتصل أحدهما بالأخر اتصال النقيض بالنقيض.والمناقضة في القول هي أنْ يتكلم المتكلم بما يتناقض معناه ويخالفه.والفرق بين التناقض والتضاد أنَّ التضاد هو أنْ يتنافى اللفظان في اصل الوضع أو الوجود أمّا التناقض فهو أنْ يتنافى اللفظان في المعنى لا في أصل وضعهما. وفكرة اتصال النقيض بالنقيض قال بها الطبرسي (ت 548هـ) في كتابه (مجمع البيان في تفسير القرآن) وقد أثبتنا ذلك في صحائف هذا البحث.وقد قسمت البحث على خمسة مطالب, وقدمت المطالب التي صرح فيها باتصال النقيض بالنقيض؛ لتتضح فكرة البحث للمتلقي.


Article
Handwritten Arabic (Indian) Numerals Recognition Using Fourier Descriptorand Structure Base Classifier

Authors: Loay E. George --- Ihab A. Mohammed --- Shatha M. Noor
Journal: Al-Nahrain Journal of Science مجلة النهرين للعلوم ISSN: (print)26635453,(online)26635461 Year: 2011 Volume: 14 Issue: 2 Pages: 215-224
Publisher: Al-Nahrain University جامعة النهرين

Loading...
Loading...
Abstract

In this paper a simple and accurate method is proposed to recognize Arabic (Indian) numerals
using Fourier descriptors as the main classifier feature set, and to improve the recognition accuracy
a simple structure based classifier is add as a supplementary classifier. The recognition system was
tested on 450 samples collected from 5 students and the test results indicate that the recognition
ratio is%89.6when only 5 Fourier descriptors are used as discriminating features set, and the ratio is
raised to%98 when 4 Fourier descriptors are used in addition to the simple structure based
classifier.

في هذا البحث، تم اقتراح طريقة بسيطة، سريعة، ودقيقة لتمييز الارقام العربية (الهندية) باستخدام واصفات فورير كمصنف اساسي، ولتحسين الكفاءة تم اضافة مصنف يعتمد البنية كمصنف تكميلي. بعد اجراء الاختبارات على 450 عينة تم جمعها من قبل 5 طلاب، بينت النتائج ان نسبة التمييز هي 89.6% عند استخدام 5 واصفات فورير كمصنف اساسي، و ارتفعت نسبة التمييز الى 98% عند استخدام 4 واصفات فورير والمصنف المعتمد على البنية.


Article
THD Reduction Using Series Transformer Connection In A STATCOM Within Mosul Ring System
تقليل المحتوى الكلي للتشوه باستخدام ربط التوالي للمحولة في المعوض التزامني الساكن ضمن النظام الحلقي لمدينة الموصل

Authors: Yasser A. Mahmood ياسر احمد محمود --- Majed S. Al-Hafid ماجد صالح الحافظ --- Dhaiya A. Al-Nimma ضياء علي النعمة
Journal: AL Rafdain Engineering Journal مجلة هندسة الرافدين ISSN: 18130526 Year: 2009 Volume: 17 Issue: 5 Pages: 15-22
Publisher: Mosul University جامعة الموصل

Loading...
Loading...
Abstract

AbstractThe static synchronous compensator (STATCOM) is one of the components of Flexible AC Transmission System (FACT). STATCOM is used to compensate the reactive power with fast response. It consist of power electronic devices. The main drawback of STATCOM is harmonics injection to the system. Different techniques can be used to reduce harmonic injection, such as the use of 12-pulse STATCOM with Pulse Width Modulation (PWM) to control the operation of power electronic devices. In this work the series connection of transformers is studied and compared with parallel connection. The study is applied to the suggested STATCOM in the ring system around Mosul city. Matlab / Simulink is used to analyze the two systems. The results are given and discussed in the paper. Also it is found that the Total Harmonic Distortion (THD) can be further reduced by using series connection of transformers secondary rather than shunt connection. Keywords :STATCOM, Harmonic reduction, Transformer connection in STATCOM, Mosul distribution ring.

يعد المعوض التزامني الساكن (STATCOM) احد مكونات نظام النقل المتناوب المرن (FACT). حيث يستخدم المعوض التزامني الساكن لتعويض القدرة المتفاعلة باستجابة سريعة. ويتكون من نبائط الكترونيات القدرة. ويمثل توليد مجموعة من التوافقيات في الشبكة عائقا رئيسيا عند استخدامه. وهناك تقنيات مختلفة تعمل إلى تقليل هذه التوافقيات كثيرا منها استخدام المعوض ذو 12 نبضة وفق تقنية تضمين عرض النبضة (PWM). تم في هذا البحث دراسة استخدام ربط التوالي للمحولة في المعوض التزامني الساكن ومقارنته مع ربط التوازي. طبق التحليل على المعوض المتزامن المقترح للنظام الحلقي لمدينة الموصل. وتم تحليل الشبكة باستخدام برنامج Matlab / Simulink مع عرض ومناقشة النتائج. ولوحظ ان استخدام ربط التوالي لثانوي تلك المحولات يقلل كثيرا من المحتوى الكلي للتشوه (THD) مقارنة مع ربط التوازي.


Article
STUDY OF BENDING BEHAVIOR OF REINFORCED CONCRETE SECTIONS UNDER CYCLIC LOADS
دراسة سلوك الانحناء للمقاطع الخرسانية المسلحة تحت تاثير الاحمال الدورية

Author: احمد يونس محمد, د.مؤيد سعد الله خليل،د.موفق يونس محمد
Journal: Tikrit Journal of Engineering Sciences مجلة تكريت للعلوم الهندسية ISSN: 1813162X 23127589 Year: 2007 Volume: 14 Issue: 1 Pages: 1-27
Publisher: Tikrit University جامعة تكريت

Loading...
Loading...
Abstract

This paper is concerned with the bending behavior of reinforced concrete sections subjected to cyclic loads, such as wind loads or earthquake loads. Previous studies have indicated that the cyclic loading of such kind can cause failure in the joints of a structure which subseguently put the structure into the state of insability or collapse.the papear also pays attention to the behavior of reinforced concrete beams and frames.Modeling of the cyclic relationship between moment and curvature is presented for the reinforced concrete sections under effect of axial load and moment on the assumption of full bond between steel and concrete. The shear deformation however is sidestepped.The stiffness method with the effective secant stiffness is used in the analysis of the structures for calculating displacement in each section and then getting the load-displacement curves, moreover, the recurrence method is used in the analysis of simple members in structures like reinforced concrete beams subjected to cyclic loads.The current study presents a numerical model which is capable of predicting the behavior of a reinforced concrete beam, frame and joint subjected to cyclic loading. The effect of axial force on the structure is also considered.The study concludes that the effect of axial force in the structural members is to decrease the energy absorption by these members and increases their failure loads. It also shows that the model used in the analysis of reinforced concrete sections has a good accuracy, it has ability to decrease the time of computer running compared with other methods, this makes it possible to depend on the analysis .The stiffness and recurrence method show good activity in the analysis from the obtained results.

في هذا البحث تم دراسة سلوكية الانحناء في المقاطع الخرسانية المسلحة المعرضة إلى أحمال دورية كأحمال الرياح أو الهزات الأرضية وذلك لما تشكله من أهمية في استقرارية أو فشل المنشات , إذ لوحظ من خلال البحوث والدراسات أن الفشل يحدث في المنشات بعد أن تفشل المفاصل فيها ويطلق عليها اسم المناطق الحرجة. كما تطرق البحث إلى دراسة سلوك الهياكل والعتبات الخرسانية المسلحة.ويقدم البحث نموذجاً رياضياً يتكهن بسلوك العتبات والهياكل والمفاصل الخرسانية المسلحة الواقعة تحت تأثير الأحمال الدورية.وتم في هذه الدراسة نمذجة العلاقة الدورية بين العزم والتقوس للمقطع الخرساني المسلح تحت تأثير قوى العزم والضغط المحوريين مقترحين وجود ترابط تام بين الخرسانة وحديد التسليح مهملين تأثير التشوه الناتج من قوى القص .كما تمت الإفادة من طريقة الجساءة والجساءة القطاعية المؤثرة في تحليل المنشات وحساب العزوم الازاحات في كل مقطع وبالتالي الحصول على علاقـة (الحمل-الإزاحة) , فضلاً عن استخدام طريقة التكامل في تحليل الأعضاء البسيطة من المنشأ كالعتبات الخرسانية المسلحة المعرضة للأحمال الدورية. وتم في الدراسة ادخال تاثير القوى المحورية على هذه المنشات ايضاً.خلصت الدراسة الى ان القوة المحورية المؤثرة على الأعضاء الإنشائية أسهمت في اختزال قابلية هذه الأعضاء على امتصاص الطاقة آلا أنها آدت الى زيادة حمل الفشل لهذه الأعضاء فأظهرت الدراسة ان النموذج المستخدم في تحليل المقطع الخرساني المسلح عمل بكفاءة لابأس بها وسرعة في عملية التنفيذ مقارنة مع الطرائق الأخرى تجعل في الإمكان الاعتماد عليه في عملية التحليل . كما بينت طريقتي الجساءة والتكامل كفاءة جيدة في عملية التحليل وذلك من خلال النتائج التي تم الحصول عليها.


Article
Strengthening Of R.C. Beams by External Steel Plate Using Bonded and Unbonded Connectors
تقوية العتبات الخرسانية المسلحة بواسطة الصفائح الحديدية الخارجية بإستخدام الروابط المقيدة وغير المقيدة

Authors: Ashraf A. Alfeehan --- Rana H. Alkerwei
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2015 Volume: 33 Issue: 1 Part (A) Engineering Pages: 90-100
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

Structural rehabilitation represents an important aspect of the construction industry and its significance is increasing. Strengthening is the process of increasing of the existing capacity of a non-damaged structure or a structural component to a specified level. The main aim of this work is to compare the strengthening techniques by bonded and unbounded mechanical connection as well as studying of replacing internal tension bars by external steel plate with the traditional method of bonding by glues on ultimate strength of RC beams. The traditional method use the epoxy glues for interfaces bonding while the idea of these techniques is a connection of external steel plate with RC beams by shear connectors mechanically. The experimental work involves flexural testing of six concrete beams of 100 150 1500mm. The test variable includes the percentage of replacing the internal reinforcement with external steel plate. Comparison of methods of bonded and unbounded beam is implemented with the method of strengthening by glue. Results show that beams reinforced with external steel plate behave as a composite action right up to ultimate load and the mode of failure occurs by yielding of external plate, pullout or yielding the shear connectors not by separation of plate. Using of external steel plate restrains central deflection in the beam with increasing of load capacity by increasing thickness of plates.

يمثل تأهيل وتقوية المنشآت مبدأ مهما في مجال الصناعة الإنشائية و تزداد أهميته بسبب حاجة الأبنية لأعمال التقوية والصيانة. تقوية المنشآت هي زيادة لقابلية تحمل المنشأ أو العناصر الإنشائية غير المتضررة لمستوى معين. الهدف الرئيسي لهذا البحث دراسة عملية ونظرية ومقارنة لطرق ربط الصفائح الفولاذية والعتبات الكونكريتية وإستبدال التسليح الداخلي بالتسليح الخارجي بإستخدام روابط القص المقيدة وغير المقيدة بطريقة ميكانيكية تختلف عن الأسلوب التقليدي في ربط الصفائح الخارجية بسطح العتبة الخرسانية باستعمال المواد الأيبوكسية اللاصقة. تتضمن هذه الدراسة فحص الانثناء لست عتبات خرسا نية (100 150 1500ملم) للتحقق من تأثير زيادة سمك الصفيحة وتأثير نسبة استبدال التسليح الداخلي بالصفيحة الفولاذية الخارجية ونوع الربط. أظهرت نتائج هذه الدراسة انه باستخدام أسلوب الربط الميكانيكي بين العتبة الخرسانية و الصفيحة الفولاذية يتصرف العنصر الإنشائي كوحدة واحدة الى حد الحمل الأقصى ويكون طور الفشل بخضوع حديد الصفائح الخارجية أو سحب وخضوع روابط القص ولا يحدث عزل بين العتبة والصفيحة إطلاقا. استخدام الصفائح الفولاذية كحديد تسليح خارجي أظهر تقييد في الإزاحات المقاسة في مركز العتبة وأدت الزيادة في سمك الصفيحة الى زيادة في قابلية تحمل المقطع


Article
The Connection Between Sentences in the Zamaksharie's Al-Kashaf
تعلّق الجمل في الكشاف للزمخشري(ت538ه)

Loading...
Loading...
Abstract

The connection between sentences has been tackled by some books before Al-Kashafm, but this type of connection has been tackled by Al-Zamakshary as a distinguishing feature in his book. The study deals with the discussions between grammarians about the connection between sentences in Al-Kashaf. The study is divided into two sections: the first about the sentences that begin with nouns and the other deals with sentences that begin with verbs

إنّ تعلق الجمل بعضها ببعض قد ورد في كتب التفسير التي سبقت الكشاف، غير أنّ هذا النوع من التعلُّق قد كثُر عند الزمخشري، مما يشكل سمةً بارزةً في تفسيره، وهو ممّا دفعني إلى دراسة الموضوع في بحث يحاول تسليط الضوء على اجتهاد الزمخشري في هذا الجانب، الذي فاق فيه غيره، إذ اقتصر النحويون والمفسرون على مبحث تعلق شبه الجملة. ثم محاولة الكشف عن ما دار بين المفسرين من مناقشة وأخذ وردّ في المسائل التي تخص التعلق في الكشاف. ومن دراسة مواضع هذا التعلُّق – بحسب مادة البحث المجموعة – تبين أنها ممكن أن تقسم على مبحثين، الأول: تعلّق الجمل الاسمية، والآخر: تعلق الجمل الفعلية


Article
USING FILLET WELDS INSTEAD OF CJP GROOVE WELDS IN DIRECTLY-WELDED FLANGE FR MOMENT CONNECTIONS
استخدام لحيم الشريحة بدل لحيم الشق لربط الوصلات المقاومة للعزوم في مناطق الشفة الملحومة مباشرة

Author: Faris A. Uraiyer فارس عباس عريعر
Journal: KUFA JOURNAL OF ENGINEERING مجلة الكوفة الهندسية ISSN: 25230018 Year: 2017 Volume: 8 Issue: 3 Pages: 90-102
Publisher: University of Kufa جامعة الكوفة

Loading...
Loading...
Abstract

The possibility to use fillet welds instead of complete joint penetration welds (CJP ) in directly- welded flange FR (fully restrained) connections is the main aim of this study. An experimental comparison has been made between these two types of welds. Fifteen specimens have been configured by welding plates to form butt, Tee and lap joint connections; three specimens with butt-joint, six with lap-joint, and six specimens were with T-joint. Fillet and CJP groove welds separately have been used to make these connections. After testing of all these specimens, the results indicated that the appropriately sized fillet weld is a good alternative to CJP groove weld when it is used for fully restrained FR moment connections.

ان امكانية استخدام لحيم الشريحة بدل من لحيم الوصلة هو الهدف الرئيسي من هذا البحث . حيث تم اجراء مقارنة عملية Butt نموذج من الوصلات. حيث تضمنت لنماذج هذه بطريقة لحيم ( 15 لوصلات باستخدام كلا النوعين عن طريق عمل - Lap ) وست نماذج بطريقة (Joint T -) وست نماذج اخرى بطريقة ( Joint -.) وبعد فحص تلك الوصلات اشارت Joint النتائج الى ان لحيم الشريحة من الممكن ان يكون بديلا جيدا للحيم الوصلة في الوصلات الصلدة عندما تحدد ابعاده بصورة مناسبة.


Article
BEHAVIOR OF STEEL-NORMAL AND HIGH STRENGTH CONCRETE COMPOSITE BEAMS WITH PARTIAL SHEAR INTERACTION
سلوك العتبات المركبة من الحديد والخرسانة الاعتيادية والعالية المقاومة ذوات اتصال قص جزئي

Authors: Samoel M. Saleh سمؤل مهدي صالح --- Fareed H. AlMosawi فريد حميد الموسوي
Journal: KUFA JOURNAL OF ENGINEERING مجلة الكوفة الهندسية ISSN: 25230018 Year: 2018 Volume: 9 Issue: 1 Pages: 175-190
Publisher: University of Kufa جامعة الكوفة

Loading...
Loading...
Abstract

In this research, aimed to study the behavior of simply supported steel concrete composite beams with normal and high compressive strength of the concrete slab under the action of a span mid-point external load. The steel I-section beam is located at the bottom of reinforced concrete slab and connected with it by stud shear connectors. Eight composite beams were tested under the action of a monotonic load, half of them had a normal strength concrete slab while the others with a high strength concrete slab. Four degrees of shear connection interaction (100%, 80%, 60%, and 40%) were used for both groups of the tested beams. It was noticed that there are no essential differences between the modes of failure that occurred in the tested beams with normal strength concrete and those with high strength concrete. It was also found that there is an increase in the initial stiffness of the beams when the concrete changed from normal to high strength for different degrees of shear connections, but this increment reduced with increasing the degree of the shear connection. It was noted that the ultimate capacity of the tested beams was increased with enhancement of the strength of the adopted concrete from normal to high strength. The results showed that, when the concrete compressive strength was increased from 32.6 MPa to 72.8 MPa, the ultimate moment capacity of the specimens was increased from 28% for 100% shear connection, and it is increased to 38% for specimens with 40% shear connection.

يتناول هذا البحث دراسة تجريبية لمعرفة سلوك العتبات المركبة ذات الاسناد البسيط وذات بلاط خرساني اعتيادي وعالي تقع في I المقاومة معرضة لحمل خارجي مركز في منتصف طول العتبة ، تتكون العتبة من عارضة حديدية ذات مقطع الجزء السفلي من البلاط الخرساني ومرتبطة معا بوصلات القص. تم صب ثمان عينات من العتبات الحديدية -الخرسانية .تم استخدام درجات HC والبقية تحوي خرسانة عالية المقاومة NCالمركبه حيث ان نصف النماذج يحوي خرسانة اعتيادية 100 تداخل قص ( ٪ ،80 ٪ ،60 ٪ ،40 ) لكلا النوعين من العتبات المركبة. وجد خلال فحص النماذج انه لا توجد اختلافات ٪ جوهرية بين انماط الفشل التي ظهرت في اختبار .كما وجد ان صلابة العتبات المركبة ذات نفس الدرجة من HCو NC الاتصال تتغير تبعا لنوع البلاطة الخرسانية. أظهرت النتائج عند زيادة مقاومة الخرسانة من 72.8 الى 32.6 MPA MPA % لذوات اتصال 38% الى 100% للنماذج ذات اتصال قص 28 يؤدي الى زيادة المقاومة القصوى للعتبات المركبة من .%40قص

Listing 1 - 10 of 22 << page
of 3
>>
Sort by
Narrow your search

Resource type

article (22)


Language

English (12)

Arabic (7)

Arabic and English (1)


Year
From To Submit

2019 (1)

2018 (5)

2017 (3)

2015 (5)

2014 (2)

More...