Article
Energy and Exergy Analysis of Rumaila-Basra Gas Turbine Power Plant During Hot Sea

Authors: Safaa Hameed Faisal صفاء حميد فيصل --- Mujtaba Al.Mudhaffar مجتبى المظفر --- Ali Disher Khetar علي دشر خطار
Journal: Basrah Journal for Engineering Science مجلة البصرة للعلوم الهندسية ISSN: Print: 18146120; Online: 23118385 Year: 2017 Volume: 17 Issue: 1 Pages: 26-34
Publisher: Basrah University جامعة البصرة

Loading...
Loading...
Abstract

In this paper, energy and exergy concepts have beencarried out on one of the largest gas turbine power plants inIraq (Rumaila-Basra). Both ISO operating conditions as wellas actual operating data recorded for one month in hot seasonare considered. Results indicate that a lot of heat energyaccompanied with remarkable exergy is discharged to theatmosphere. Also, it is found that the combustion chamber hasthe largest exergy destruction among the plant components.The possibility of cooling the intake air drawn by the compressorand its effects on the plant performance is studied. Therequired cooling load is found to be in the range 3379 T.R forpart load operation to 4723.3 T.R for full load operation


Article
Performance Assessment of LiBr-H2O Absorption Chiller for Air Conditioning Purposes
تقييم أداء مثلج ماء امتصاصي يعمل بمحلول )ماء + بروميد الليثيوم (لأغراض تكييف الهواء

Authors: Qusay Rasheed Al-Amir --- Hameed Kadhem Hamzah --- Riyadh S.Al-turaihi
Journal: journal of kerbala university مجلة جامعة كربلاء ISSN: 18130410 Year: 2017 Volume: 15 Issue: 3 Pages: 160-173
Publisher: Kerbala University جامعة كربلاء

Loading...
Loading...
Abstract

The thermodynamic analysis of a 4TR single stage absorption chiller is executed numerically using Engineering Equation Solver (EES) software. In this chiller, water and lithium bromide mixture is used as a working fluid and supplies by hot water from electrical boiler at any temperature. The investigation is done to assess the effect of varying the exit temperatures of the absorber, evaporator, generator, and condenser on the absorption chiller cycle performance. The cycle simulation is based on the operating temperature ranges and fixed parameters which include as follows: evaporating exit temperature within a range of 2-11 °C, generator exit temperature within a range of 80-89°C, condenser exit temperature range from 30 to 48°C, absorber exit temperature range from 20 to 38°C, three magnitudes of effectiveness of heat exchanger (0.6, 0.65 and 0.7), strong solution flow rate 0.05 kg/s. The results depicted that the performance parameters are affected by the operation temperatures of main components and heat exchanger effectiveness

تم اجراء دراسة عددية ببرنامج EES على مثلج ماء امتصاصي بسعة تتراوح 4 طن تثليجي . هذا المثلج يعمل بمحلول ماء و بروميد الليثيوم كمائع تشغيلي ويجهز بالمائع الحار عن طريق غلاية كهربائية. الهدف من هذا البحث, دراسة تاثير تغير درجات الحرارة الخارجة من الماص و المبخر و المولد والمكثف على أداء مثلج الماء. المحاكاة العددية تمت عند معدلات درجات حرارية مختلفة وكانت كالآتي: درجات الحرارة الخارجة من المبخر بين 2 و11°م, درجات الحرارة الخارجة من المولد بين 80 و89°م , درجات الحرارة الخارجة من المكثف بين 30 و 48°م و درجات الحرارة الخارجة من الماص بين 20 و38°م. كذلك تم دراسة تأثير تغير قيم فعالية المبادل الحراري على أداء المثلج وكانت على التوالي 0,6 و 0,65 و0,7. النتائج المستحصلة بينت ان أداء المثلج يتأثر بتغير درجات الحرارة التشغيلية للمكونات الأساسية للنظام بالإضافة الى تأثره مع تغير قيم فعالية المبادل الحراري.


Article
Numerical Study of Refrigerant Flow in Capillary Tube Using Refrigerant (R134a)(English))
دراسة عددية لجريان مائع التثليج في الأنبوبة الشعرية باستخدام مائع التثليج (R134a)

Authors: Dr. Amir S. DawoodAss د. أمير سلطان داؤود --- Salim Ibrahim Hasan سالم إبراهيم حسن
Journal: AL Rafdain Engineering Journal مجلة هندسة الرافدين ISSN: 18130526 Year: 2013 Volume: 21 Issue: 1 Pages: 1-19
Publisher: Mosul University جامعة الموصل

Loading...
Loading...
Abstract

Abstract The present research aims at buildingof a mathematical model using (Engineering Equation Solver) (EES) software to analyze the flow of the refrigerant R134a into two configurations of adiabatic capillary tubes (straight and helical coiled tubes) which are used widely in a household refrigerator, freezer and water cooler. The governing equations which depend on the conservation of mass, momentum, and energy have been coded in order to calculate the length of the single-phase flow region. Moreover, the two-phase regionhasbeen divided numerically depending on homogenous flow assumption after determining the boundary conditions and calculating the physical variables at each point of the numerical divisions by using successive substitution method using iteration loops. Finite difference scheme, the length of thetwo-phase region and the total length for the capillary tube have also been determined. The results show that the behavior of the flow is similar for both forms with regard to the distribution of variables (pressure and temperature drop, dryness fraction, velocity and entropy) over the whole length , while the helical coiled tube length for all cases is shorter than the straight tube at the same conditions. The main parameters that affect the size of capillary tube and the behavior of refrigerant through it have been shown. The tube length increased with the increase of (condenser temperature, degree of sub-cooling and tube diameter) and decreased with the increase of mass flow rate and roughness. The helical tube length increased by increasing coil diameter and coil pitch . The results of the present study agree with the experimental data of previous works with error not exceeding ±10% .Keywords : Adiabatic capillary tube, Household refrigerators, R134a, EES, Helical, Two-phase flow.

الخلاصة يتضمن البحث الحالي بناء أنموذج رياضياتي لتحليل جريان مائع التثليج R134a في شكلين من الأنابيب الشعرية الأديباتية (المستقيمة والملفوفة بشكل لولبي) المستخدمة بشكل واسع في الثلاجات والمجمدات وبرادات الماء المنزلية باستخدام برنامج حل المعادلات الهندسية (EES). لقد تمت برمجة المعادلات الحاكمة المعتمدة على معادلات حفظ الكتلة والطاقة والزخم, لحساب طول المجال أحادي الطور ومن ثم تقسيم المجال ثنائي الطور عددياً بالاعتماد على فرضية الجريان المتجانس بعد حساب الظروف المحددة وحساب المتغيرات الفيزياوية في كل نقطة من التقسيم العددي بطريقة التعويض المتعاقب وذلك بعمل حلقات تكرارية, وحساب طول المجال الثنائي الطور بطريقة الفرق المحدد وبعدها تم حساب الطول الكلي للأنبوب . تبين من النتائج أن سلوك الجريان متشابه في كلا الشكلين من حيث توزيع المتغيرات (انحدار الضغط ودرجة الحرارة ونوعية البخار والسرعة والإنتروبي) على طول الأنبوب . لكن طول الأنبوب الملفوف يكون في جميع الحالات أقصر من طول الأنبوب المستقيم عندما تكون المعالم الأخرى ثابتة. وتم توضيح المعالم الرئيسية التي تؤثر على اختيار الحجم المناسب للأنبوب وعلى سلوك جريان المائع خلاله . وبينت النتائج أن طول الأنبوب يزداد بزيادة كل من (درجة حرارة المكثف ودرجة التبريد الدوني وقطر الأنبوب) ويقل بزيادة (معدل جريان الكتلة وخشونة السطح الداخلي للأنبوب) وكذلك يزداد بزيادة (قطر اللفة وخطوة اللفة). وأظهرت نتائج الدراسة الحالية توافقاً جيداً بالمقارنة مع البيانات التجريبية في الدراسات السابقة وبنسبة خطأ لاتتجاوز ±10% .


Article
A Numerical and Experimental Study of Steam Condenser Working with Modified Rankine Cycle
دراسة عددية وعملية لمكثف بخاري يعمل بدورة رانكن المعدلة

Author: Hisham Hassan Jasim
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2013 Volume: 31 Issue: 1 Part (A) Engineering Pages: 156-171
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

A Numerical and experimental study of thermal and heat transfer processes in a steam condenser operating in steam power plant with steam engine was developed to built analytical model using to predict thermal profile of condenser. Iterative technique between Engineering Equations Solver (EES) and Matlab programming was developed to find water properties .The exit water temperature, steam flow rate, geometric dimension (diameter and tube length) ,convection heat transfer coefficient of water and condenser efficiency were computed using the analytic model. Experimental results for a range of water flow rate (0.0153 to 0.0121 kg/s) with constant inlet water temperature of 25 were used to validate the analytical model. Compared with a validated model, the standard deviations of analytical model are less than 4%, and all errors fall into ±6%. Analytical model can be used to show the relation between thermal parameters.

تضمن العمل في هذا البحث دراسة عددية وعملية لكل من عمليات داينميك وانتقال الحرارة لمكثف بخاري يعمل بوحدة توليد قدرة تستخدم محرك بخاري لبناء موديل رياضي يستخدم للتنبؤ بالأداء الحراري للمكثف . اعتمد على تقنية التكرار بين (EES) و(Matlab) بداءً من قيم الإدخال الأولي للحصول على خواص الماء. يستخدم الموديل الرياضي للحصول على درجة حرارة خروج الماء ومعدل تدفق البخار و قطر وطول الأنبوب ومعامل انتقال الحرارة بالحمل لماء التبريد مع كفاءة الأداء للمكثف. وحدة توليد قدرة تم اعتمادها للحصول على النتائج المختبرية ولمدى من قيم تدفق ماء التبريد (0.0153 - 0.0121 kg/s) ودرجة حرارة ثابتة لدخول الماء ( 25) لتصديق نتائج الموديل. عند مقارنة نتائج الموديل الرياضي مع النتائج المختبرية وجدنا انحراف معياري اقل من 4% ونسب خطاء تقع ضمن حدود ±6%. يمكن استخدام الموديل الرياضي لبيان علاقة الخواص الحرارية فيما ببينها.


Article
Modeling and Simulation of an Absorption Solar Cooling System Under Iraqi Weather Conditions

Author: H.A. Hussein
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2017 Volume: 35 Issue: 4 Part (A) Engineering Pages: 356-364
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

This work aims to model and simulate an absorption cooling system using solar flat- plate receiver with water lithium bromide (li.Br-H2O) mixture as a working fluid, and to select the optimum type for absorption cooling system, which have suitable application in Iraq. Weather conditions for Erbil city have been selected. Coefficient of performance (COP) for a single, double (series and parallel), half and triple effect of an absorption cooling system are calculated and optimized. COP Prediction, hot water temperature, and the rate of heat transfer have been simulated and represented by using TRNSYS and EES programs. Active area of the solar flat-plate receiver is calculated and optimized for five suggested areas of (140, 150, 160, 170, and 180 m 2). Average heating load, average daily - radiation and cooling load for summer months (June, July, August, and September) have been calculated. The results indicated that, the superior type of the four absorption-cooling systems is a single effect, which has COP 80% at generator temperature of (81 °C). Also the results indicated that the optimum area of solar flat-plate receiver was 160 m2 which has achieved the maximum capacity of cooling power and consumed capacity in the generator (50, and 62.5) kW respectively. I think, according to the previous studies , the current work is the first in Iraq because it approved that, single effect type is an efficient and more relevant type for good working under Iraqi climate by using solar flat–plate receiver and suitable to apply it experimentally in a wide range.


Article
ANALYSIS AND SIMULATION OF A TRIPLE-STAGE SERIES FLOW ABSORPTION CHILLER CYCLE FOR AIR CONDITIONING APPLICATIONS

Author: Qusay Rasheed AL-AMIR
Journal: Al-Qadisiyah Journal for Engineering Sciences مجلة القادسية للعلوم الهندسية ISSN: 19984456 Year: 2017 Volume: 10 Issue: 2 Pages: 226-243
Publisher: Al-Qadisiyah University جامعة القادسية

Loading...
Loading...
Abstract

This paper represents a numerical study of a triple-stage series flow absorption cycle operating with LiBr-H2O pair. A computational model is implemented using Engineering Equation Solver (EES) software. This model includes equations of mass, species and energy conservation. The analysis is used to simulate a triple stage absorption chiller utilization for an air conditioning applications with a nominal capacity of 300kW manufactured by Thermax company. This chiller is indirect fired type which uses steam from boiler of the HPG as heat source. The variations of performance parameters with different ranges of operation conditions have been calculated. The operating parameters are selected as follows: the HPG, MPG and LPG temperatures: THPG= 150-230°C, TMPG= 100-130°C and TLPG= 60-95°C, respectively, LPC temperature TLPC= 28-37°C, evaporator temperature Tevap = 5-14°C; flow rate of refrigerant mr= 1 kg/s; four values of heat exchangers effectiveness 0.4, 0.5, 0.6 and 0.65. In addition, the comparison between the present study and other study obtained in literature review has been done. The analysis revealed that maximum COP is found as a function of both MPG and LPG temperatures. The results outline that the COP increases with an increase in the evaporator and generators temperature but decreases with condenser temperature.


Article
Modeling and Simulation of Thermal Performance of Solar-Assisted Air Conditioning System under Iraq Climate
تقييم الاداء الحراري لمنظومة تكييف هواء تعمل بمساعدة الطاقة الشمسية في العراق نظًرياً

Authors: Mohammed Abdulhassan Abid Mohammed Abdulhassan Abid محمد عبدالحسن عبد --- Najim Abid Jassim نجم عبد جاسم
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2016 Volume: 22 Issue: 8 Pages: 175-194
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

In Iraq most of the small buildings deployed a conventional air conditioning technology which typically uses electrically driven compressor systems which exhibits several clear disadvantages such as high energy consumption, high electricity at peak loads. In this work a thermal performance of air conditioning system combined with a solar collector is investigated theoretically. The hybrid air conditioner consists of a semi hermetic compressor, water cooled shell and tube condenser, thermal expansion valve and coil with tank evaporator. The theoretical analysis included a simulation for the solar assisted air-conditioning system using EES software to analyze the effect of different parameters on the power consumption of compressor and the performance of system. The results show that refrigeration capacity is increased from 2.7 kW to 4.4kW, as the evaporating temperature increased from 3 to 18 ºC. Also the power consumption is increased from 0.89 kW to 1.08 kW. So the COP of the system is increased from 3.068 to 4.117. The power consumption is increased from 0.897 kW to 1.031 kW as the condensing temperature increased from 35 ºC to 45 ºC. While the COP is decreased from 3.89 to 3.1. The power consumption is decreased from 1.05 kW to 0.7kW as the solar radiation intensity increased from 300 W/m2 to 1000 W/m2, while the COP is increased from 3.15 to 4.8. A comparison between the simulation and available experimental data showed acceptable agreement.

معظم المباني الصغيرة والمتوسطة في العراق تعتمد على انظمة التبريد ذات الضاغط الكهربائي والذي من عيوبه الاستهلاك العالي للطاقة الكهربائية عند حمل الذروة. في هذا العمل تم التحقق نظريا من الاداء الحراري لمنظومة تكييف الهواء المركبة مع مجمع شمسي. يتكون مكيف الهواء الهجين من ضاغط شبه مقفل، مكثف نوع الاسطوانة والانبوب المبرد بالماء، صمام تمدد حراري ومبخر نوع الخزان والملف. شمل التحليل النظري محاكاة لمنظومة تكييف الهواء التي تعمل بمساعدة الطاقة الشمسية باستخدام برنامج EES لتحليل تأثير عوامل مختلفة على استهلاك طاقة الضاغط وأداء المنظومة. بينت النتائج ان سعة التثليج قد زادت من 2,7 الى 4,4 كيلو واط مع زيادة درجة حرارة التبخير من 3 الى 18 درجة مئوية وكذلك فان الطاقة المستهلكة قد زادت من 0.89 الى 1.08 كيلو واط , والذي ادى الى زيادة معامل اداء المنظومة من 3,068 الى4,117. ان الطاقة المستهلكة قد ازدادت من 0,897 الى 1,031 كيلو واط مع زيادة درجة حرارة التكثيف من 35 الى 45 درجة مئوية. بينما معامل الاداء قد انخفض من من 3,89 الى 3,1. ان الطاقة المستهلكة قد انخفضت من 1,05 الى 0,7 كيلو واط عند زيادة الاشعاع الشمسي 300 الى 1000 واطم2, بينما معامل اداء المنظومة قد ازداد من 3,15 الى 4,8. واظهرت المقارنة بين النتائج التجريبية والنظرية اتفاق مقبول بينهما.


Article
AN ASSESSMENT THE EFFICIENCY FOR A PARABOLIC TROUGH SOLAR COLLECTOR WITH DIFFERENT HORIZONTAL AXIS BY USING TRACKING SYSTEM
الكفائة لمجمع شمسي ذي قطع مكافئ باختلاف الاحداثي الأفقي وباستخدم معقب شمسي

Author: Ali A. F. Al- Hamadani
Journal: DIYALA JOURNAL OF ENGINEERING SCIENCES مجلة ديالى للعلوم الهندسية ISSN: 19998716/26166909 Year: 2017 Volume: 10 Issue: 1 Pages: 48-57
Publisher: Diyala University جامعة ديالى

Loading...
Loading...
Abstract

The solar energy in Iraq is available, but till now a little application for using it. The parabolic trough solar collector (PTSC) technology, which considers being one of the low-cost and most operative technologies for solar power plant. The performance of a PTSC with solar tracking system has been experimentally investigated under Kut city, Iraqi climate conditions. The experimental work focused on changing the horizontal axis and mass flow rate of water. It has been started with 0o, 30o, 60o receptively. The zero angle represents an east direction, then rotate toward the south. The instantaneous efficiency was employed to evaluate the thermal performance of the PTSC. The equation had been solved using equation engineering solver (EES). The results showed that Kut city holds a good potential for such energy generation technology with an average efficiency of 38.8% and instantaneous efficiency that can reach as high as 70%. This study is highly encouraging the Iraq government to invest in the PTSC technology in Iraq to meet the increasing demand on electric power. The best efficiency is zero angle which represents the east direction. The efficiency, enhanced with the mass flow rate till certain value. The heat transfer coefficient for zero angle was significant compare with other angles. The result was validated with fixed parabolic trough and a good agreement. The performance improved with increase the mass flow rate till 30 kg/hr after that no any effect of it.

الطاقة الشمسية متوفرة في العراق لكن تطبيقاتهاقليلة. البحث يتناول دراسة عملية لمجمع شمسي ذي قطع مكفئ مع منظومة تعقب. البحث تم في الظروف الجوية لمدينة الكوت-العراق. الكفائة الحرارية والانية تم توضيفها لمعرفة الاداء الحراري لجهاز. الاحداثي الافقي تم تغييره للجهاز وللزوايا 0،30،60 حيث ان الزاوية ضفر تمثل الشرق ومن ثم التدوير باتجه الجنوب. النتائج بينت ان مدينة الكوت جيدة لتوليد الطاقة الكهربائية وان كفائة الجهاز 38.8% والكفائة الانية 70%. النتائج مشجعة للتطبيقات الشمسية في هذه المنطقة لسد النقص في الطلب على الطاقة. النتائج العملية وضحت ان افضل كفائة عند الزاوية هي الصفر. التغير في درجات الحرارة بين دخول الماء وخروجه اعلى عند الزاوية صفر. المجمع الشمسي تم مقارنته مع مجمع شمسي ثابت وكانت النتائج جيدة.

Keywords

The solar energy in Iraq is available --- but till now a little application for using it. The parabolic trough solar collector --- PTSC technology --- which considers being one of the low-cost and most operative technologies for solar power plant. The performance of a PTSC with solar tracking system has been experimentally investigated under Kut city --- Iraqi climate conditions. The experimental work focused on changing the horizontal axis and mass flow rate of water. It has been started with 0o --- 30o --- 60o receptively. The zero angle represents an east direction --- then rotate toward the south. The instantaneous efficiency was employed to evaluate the thermal performance of the PTSC. The equation had been solved using equation engineering solver --- EES. The results showed that Kut city holds a good potential for such energy generation technology with an average efficiency of 38.8% and instantaneous efficiency that can reach as high as 70%. This study is highly encouraging the Iraq government to invest in the PTSC technology in Iraq to meet the increasing demand on electric power. The best efficiency is zero angle which represents the east direction. The efficiency --- enhanced with the mass flow rate till certain value. The heat transfer coefficient for zero angle was significant compare with other angles. The result was validated with fixed parabolic trough and a good agreement. The performance improved with increase the mass flow rate till 30 kg/hr after that no any effect of it. --- الشمسي،المجمع الشمسي،المعادلات الهندسية، المعقب الشمسي