research centers


Search results: Found 4

Listing 1 - 4 of 4
Sort by

Article
Non-Sinusoidal Loading Effect on Oil Immersed Power Transformers

Author: Mohammed k.Edan
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2011 Volume: 29 Issue: 12 Pages: 2386-2400
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

Transformers are usually designed for nominal frequency and sinusoidal load current. Nowadays, usage of non-linear loads such as power electronics loads has extremely increased. These loads produce harmonic currents, which induce additional losses in transformer windings and other transformer parts and cause temperature rise, and ultimately can cause insulation deterioration, ageing and finally fast failing. The purpose of this paper effort to quantify the increasing in transformerlosses due to harmonic load current and the corresponding temperature rise intransformer and study the effect of harmonics on loss of insulation life, total ownership cost of transformer, capacity of transformer and oil viscosity. An eddy current harmonic loss factor for transformer windings and harmonic loss factor for other stray loss are presented and used to calculate the transformer losses under harmonic load currents. The impact of transformer winding conductor size onwinding eddy current harmonic loss factor is presented. Three loads with different amount of harmonic content of load current are proposed in this paper.


Article
Electromagnetic Interference Caused by Iraqi 400kV Transmission Lines on Buried Oil Pipelines
التداخلات الكھرومغناطیسیة المتسببة بواسطة خطوط نقل الطاقة العراقیة 400kv على خطوط انابیب النفط المدفونة

Author: Suad I. Shahl
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2010 Volume: 28 Issue: 24 Pages: 6937-6953
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

The electromagnetic interference caused by power transmission lines to oil and gas buried pipelines is under investigation for many years. Especially during fault conditions, large currents and voltages are induced on the pipelines that may pose danger to working personnel or may accelerate the corrosion of the pipelin’es metal. In this research, the Joule effect of eddy currents induced in the oil buriedpipelines due to the magnetic fields produced by nearby 400kV transmission lines in the South of Iraq have been computed. A computational model based on 2D finite element approach to calculate the heat generation rate. The influence of different earth resistivities for homogeneous earth model during steady state andfault conditions is analyzed. A mitigation system using mitigation wires has been simulated to reduce induced eddy current heating effects to the safety limit.

تخضع التداخلات الكهرومغناطيسية المتولدة من خطوط نقل الطاقة على خطوط انابيب النفط والغاز والممتدة تحت الارض للبحث منذ عدة سنوات. خصوصا اثناء ظروف الاعطال حيث تتسبب هذه التداخلات في توليد تيارات وفولتيات كبيرة مستحثة على خطوط الانابيب التي قد تشكل خطر لتشغيل العاملين او قد تعجل من تآكل معدن خط الأنابيب. سيتم في هذا البحث حساب الأثر الحراري للتيارات الدوامية المحتثة بسبب المجالات المغناطيسية المتولدة من 400 في جنوب العراق على خطوط انابيب النفط القريبة والممتدة Vk خطوط نقل الطاقة ذاتتحت الارض. لقد استخدم نموذج حسابي مستند على نظرية العنصر المحدود ثنائي البعد في حساب المعدل الحراري المتولد. تم تحليل تأثير مختلف المقاومات النوعية لنموذج متجانس للارض اثناء الظروف العادية وفي حالة وجود عطل.وهذا يتطلب القيام بأجراءات وقائية للحد والتقليل من تأثيرات الأثر الحراري للتيارات الدوامية المحتثة بما يتوافق مع حدود الامان .


Article
Method for Shielding the Magnetic Field Generated in a 132/33/11(6.6)KV Baghdad Indoor Distribution Substation
طریقة للحمایة من المجال المغناطیسي المتولد في داخل محطة توزیع ثانویة 132/33/11 (6.6)kV في بغداد

Author: Suad I. Shahl
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2012 Volume: 30 Issue: 15 Pages: 2562-2576
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

This research introduces the study carried out on one of Baghdad East 132/33/11(6.6) kV distribution substations to mitigate 50Hz magnetic field of indoor distribution substation under normal operation. Shielding was performed at the power sources such as busbars rather than at the affected areas. Three-dimensional finite element method (FEM) is used to calculate the magnetic field density in the space nearby the busbars so as to analyze the shielding effectiveness of an eddy current shield applied to a 132/33/11(6.6)kV substation. It also deals with the influence of shield distance from busbar, thickness and material of shield on the eddy current losses and shielding efficiency applied to 3D finite element model of a particular busbar configuration.

يقدم هذا البحث دراسة نفذت على احدى محطات التوزيع الثانوية 133/33/11(6.6)kV في شرق بغداد للتخفيف من المجال المغناطيسي ذي التردد (50Hz) داخل محطة التوزيع ثانوية تحت ظروف التشغيل الطبيعي. نفذت الحماية عند مصادر الطاقة مثل القضبان العمومية بدلا من المناطق المتأثرة. استخدمت طريقة العنصر المحدود ثلاثية الابعاد في حساب كثافة المجال المغناطيسي في الفضاء القريب من القضبان العمومية لكي نحلل فعالية درع وقاية التيارات الدوامة المسلط على المحطة الثانوية .133/33/11(6.6)kV حيث يتعامل هذا البحث مع تأثير المسافة بين الدرع الواقي و القضيب العمومي, سمك ومادة معدن الدرع الواقي على خسائر التيار الدوام وكذلك كفاءة الحماية لترتيب معين لقضيب عمومي بأعتماد نموذج ثلاثي الابعاد للعنصر المحدود.


Article
Analysis of Induction Cooker Coil
تحلیل ملف الطھي الحثي

Authors: Hassan A. Al-Ssadi --- A.K.M. Al-Shaikhli
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2010 Volume: 28 Issue: 21 Pages: 6288-6305
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

The use of induction heating in industrial applications is old and wide. In recent years, this technology was entered to domestic use. This research deals with the analysis and applications of induction heating for cooking food, as these techniques have safe and economy, as well as cleanness and the atmosphere of work comfortable. Knowledge of the electrical resistance of induction heating system is very important to designers working in the high frequency-supplies. This research also analyzes and studies this resistance, by used solid, litz and twistedwire, and offers simplification of equations derivation help anyone interested in this subject. The MATHCAD V.14 program has been employed to obtain the results. The results presented as general curves for three types of wires (solid, litz and twisted wire) so that a designer can use them without lengthy and complex calculations.

أستعمال التسخین الحثي في للتطبیقات الصناعیھ قدیم و واسع و في السنوات الأخیرة دخلت ھذه التقنیة الى الأستعمالات المنزلیة. یتناول ھذا البحث أستعمال التسخین الحثي في طھي الطعام, حیث أن ھذه التقنیة تمتاز بالأمان و الأقتصاد و النظافة و أجواء العمل المریحة.. أن معرفة المقاومة الكھربائیة لمنظومة التسخین الحثي مھمھ جداً في تصمیم مجھز القدرة ذي الترددات العالیة(solid, litz and twisted المستعمل فیھا. ھذا البحث یحلل و یدرس ھذه المقاومة عند أستعمال و یقدم تبسیط لأشتقاق المعادلات التي تساعد المھتمین بھذا الموضوع. لقد أستخدم برن امج wire) لأستخلاصالنتائج حیث قدمت ھذه النتائج على شكل منحنیات لثلاثة أنواع MATHCAD V.14 تتیح للمصمم أستخدامھا بدون ضیاع للوقت و (solid, litz and twisted wire) من الأسلاك الحسابات المعقدة

Listing 1 - 4 of 4
Sort by
Narrow your search

Resource type

article (4)


Language

English (4)


Year
From To Submit

2012 (1)

2011 (1)

2010 (2)