research centers


Search results: Found 2

Listing 1 - 2 of 2
Sort by

Article
The effect of different types of mouth washes on the modulus elasticity of elastic ligature

Author: Wael Abdul Razzak Al waelly
Journal: Muthanna Medical Journal مجلة المثنى الطبية ISSN: 2226146x Year: 2017 Volume: 4 Issue: 1 Pages: 1-7
Publisher: Al-Muthanna University جامعة المثنى

Loading...
Loading...
Abstract

The mouth washes are widely used for maintain oral hygiene for patient wearing fixed orthodontic appliances but had effect on the elastic ligature so it’s important to measure the modulus elasticity of elastic ligature. This study was carried out to evaluate the effect of different type of mouthwashes on modulus elasticity of the elastic ligature. A 40 elastic ligatures were selected from commercially available clear elastic ligature, the elastics were adjusted on S.S brackets which were bonded to maxillary right first premolar by chemical composite, the elastic ligatures were divided into four main groups and each group had 10 elastics as follows: group A. 10 elastic ligatures were immersed in a pool distilled water at 37c instead of saliva. Group B. 10 elastic ligatures were immersed in bio fresh. Group C. 10 elastic ligatures were immersed in corsodyl. Group D, 10 elastic ligatures were immersed in parodontax. All samples were then tested to determine the modulus elasticity by instron machine. The Paradontax mouthwash group provided a higher value of mean of the modulus elasticity of the elastic ligature followed by distilled water and Corosydel groups. The biofresh had the least value of mean of the modulus elasticity. There were highly significant differences between control and Corosydel; and control and biofresh groups (P≤0.01). No significant differences, however, between control and paradontax groups (P≥0.05). In conclusion, the Paradontax mouthwash group had a great effect on the modulus elasticity of the elastic ligature. The biofresh had the least effect on the modulus elasticity.


Article
The Cytotoxicity of Orthodontic Elastomeric Ligatures in Vitro Comparative Study

Authors: Nidhal H. Ghaib --- Khalida K. Al-Kelaby --- Selma M. Hasan
Journal: Medical Journal of Babylon مجلة بابل الطبية ISSN: 1812156X 23126760 Year: 2014 Volume: 11 Issue: 2 Pages: 311-318
Publisher: Babylon University جامعة بابل

Loading...
Loading...
Abstract

The present study was carried out to evaluate the cytotoxicity of orthodontic elastic ligatures in vitro study. Three different colours (transparent, white and yellow) from three different companies were selected. The samples were divided into 9 experimental groups each group had 10 elastic ligatures from the same colour and the same company with control group (cells with no contact with elastomeric ligatures), Also positive control group contain (Phosphate buffer saline) and negative control group contain (Tween 80) were used to verify the results of study. The cell lines were chicken embryo fibroblast and human lymphocyte of healthy person. These cells were exposed to specific media contain the extracted elutes of elastic ligatures after preserving it in this media for different times interval (1,2,3,7 and 28 days). Then the cell viability were measured by using the neutral red dye, the optical densities of living cells were measured by ELISA reader devise at wave length 490 nM, The percentage of viable cells was obtained by comparing the mean optical density (OD) in the control group (cells with no contact with elastomeric ligatures) with that obtained from supernatants of cell cultures that had been in contact with elastomeric ligatures. At the end of study, the results showed that there were increase in the percent of viable cells from the first day of experiment till day 28 and there are highly significant difference between the control group and all the experimental groups at all the periods of experiment. In conclusion there were significant difference among different manufactures, but there are statically no significant difference among different colors from the same manufacturer.

الروابط البلاستيكية هي عباره عن حلقات مطاطيه صغيره تستخدم لربط سلك التقويم مع البراكيت خلال العلاج التقويمي للأسنان .هذه الحلقات البلاستيكية متوفرة بالوان مختلفة ,تستخدم هذه المواد بصوره واسعه في عيادات تقويم الاسنان لذلك يجب الاهتمام بسميه هذه البلاستيكيات التقويمية بصوره رئيسيه الحلقات التي تستخدم داخل الفم لأنها تكون قريبه جدا من اللثة وباقي الأنسجة الرخوة. هذه الدراسة أنجزت لتقييم سميه الروابط الحلقية لتقويم الاسنان خارج الجسم. اخترنا ثلاث الوان مختلفة (شفاف, ابيض, اصفر) من ثلاث شركات مختلفة . النماذج قسمت الى تسع مجاميع تجريبيه كل مجموعه تحتوي على عشرة روابط بلاستيكية من نفس اللون ونفس الشركة مع مجموعه التحكم (خلايا بدون تماس مع الحلقات البلاستيكية) ايضا مجموعة التحكم الموجبة التي تحتوي (فوسفات بفر سلاين) و مجموعة التحكم السالبة التي تحتوي( توين 80) استخدمت لايضاح مصداقية نتائج الدراسة. الزرع الخلوي استخدم لفحص سمية هذه الحلقات البلاستيكية. نوع الزرع الخلوي المستخدم في هذه الدراسة كان من نوع الطبقة الواحدة . خط الخلايا المستخدم كان من نوع الفايبروبلاست لجنين الدجاجة وخلايا الدم (الليمفوسايت) للإنسان السليم . هذه الخلايا تعرضت الى ميديا خاصه تحتوي على مستخلص الروابط البلاستيكية بعد حفظها في هذه الميديا لفترات مختلفة (1, 2,3 ,7 و28 يوم). ومن ثم قمنا بقياس حيوية الخلايا باستخدام الصبغة الحمراء المعتدلة باستخدام جهاز الأليزا بطول موجي 490 نانو ميتر. حصلنا على نسبة الخلايا الحيه من مقارنة معدل الكثافة الضوئية في المجموعة التحكمية (خلايا بدون تماس مع الحلقات البلاستيكية) مع معدل الكثافة الضوئية لمستخلص الزرع الخلوي الذي كان بتماس مع الروابط البلاستيكية. اظهرت النتائج ان هناك زياده في نسبة الخلايا الحيه من اليوم الاول الى اليوم الثامن والعشرون من التجربة وهناك اختلاف كبير في نسبة الخلايا الحيه بين المجموعة التحكمية وكافة المجاميع التجريبية الاخرى في جميع فترات التجربة.استنتجنا ان هناك فرق كبير في نسبة الخلايا الحية بين الشركات المختلفة, لكن لم يكن هناك اختلاف في نسبة الخلايا الحية للألوان المختلفة من نفس الشركة.

Listing 1 - 2 of 2
Sort by
Narrow your search

Resource type

article (2)


Language

English (2)


Year
From To Submit

2017 (1)

2014 (1)