Enhancement the Performance of Condenser of Split Type Air Conditioning System by Using Evaporative Cooling
تحسين أداء مكثف منظومة تبريد نوع سبلت باستخدام تبريد تبخيري

Author: Lina Ismail Jassim لينا إسماعيل جاسم
Journal: Al-Ma'mon College Journal مجلة كلية المامون ISSN: 19924453 Year: 2011 Issue: 17 Pages: 230-246
Publisher: AlMamon University College كلية المامون الجامعة

Loading...
Loading...
Abstract

The reduction of energy demand is a major concern in areas with very hot weather conditions about 50Co. This can be achieved by using more energy efficient equipment. Evaporative cooling provides a low cost, energy efficient and environmental friendly alternative to traditional Air Conditioning. In this study, a simple design of applying indirect evaporative cooling which investigated experimentally to improve the coefficient of performance of split unit and power consumption. This model consists of a cooling pad behind condenser and injected water on it to reduce air temperature before it passes over the condenser. The experimental results show that the coefficient of performance increases by about 73% and the power consumption decreases by about 18%.

يتضمن هذا البحث، تصميم نموذج عملي لتحسين اداء منظومة التبريد، والتقليل من استهلاك الطاقة الكهربائية خاصة في المناطق ذات الدرجة الحرارية العالية، والتي تصل إلى حوالي 50 درجة مئوية وذلك باستخدام التبريد التبخيري. ان النموذج المستخدم يتضمن وسيط تبريد تبخيري, وهو مادة الحلفة بشكل يشبه تصميم المكثف الخاص بالسبلت، موضوعة خلف المكثف لتبريد الهواء قبل مروره على ملف المكثف، وحوض ماء ومضخة صغيرة وانابيب توصيل الماء. علما ان النتائج العملية تشير الى زيادة في معامل اداء المنظومة بنسبة 73% وانخفاض باستهلاك الطاقة الكهربائية بنسبة 18%.


Article
The Effect Of Sloping Angle And Orientation Of Inclination Roofs In Frame Building In Baghdad City On it's The Electrical Energy Consumption For Cooling Purpose
ةنيدم يف ةيلكيهلا ةينبلأل ةلئاملا فوقسلا هيجوتو تأثير زاوية ميل بغداد على الطاقة الكهربائية المستهلكة لأغراض التكييف فيها )ةيبيرجت ةسارد(

Author: Atif Ali Hasan عاطف علي حسين
Journal: Iraqi journal of mechanical and material engineering المجلة العراقية للهندسة الميكانيكية وهندسة المواد ISSN: 20761819 Year: 2011 Volume: 11 Issue: 2 Pages: 262-278
Publisher: Babylon University جامعة بابل

Loading...
Loading...
Abstract

Abstract :-The object of this paper is to find the relationship between slop angle, orientation for inclination roofs which used in frame building (steel & concrete) in Baghdad city. (Latitude 33.3º North), and it's effect on the solar heat gain value which transferred through that roofs and it's effect on the electrical power consumption for summer cooling purpose.The researcher is build (1 x 1 x 1)m frame building sample, it’s roof is rotated horizontally eight times and is made by two parts, first part is called frontal part (it’s slop angle would vary from 5° to 45°), the second part is called rear part (it’s slop angle would vary from 90° to 5°).Finally , the researcher was found the relationship between that angles will be taken the following form :If frontal angle less than 20°, the minimum electrical energy was occur at North , North East and North-West, when rear angle is 20°, while , for East, West and East-South was occur at 10°, the another orientation at 5°.If frontal angle equal to 20°, the minimum electrical energy for cooling was occur at 5° rear angle for all orientation.If frontal angle more than 20°, the minimum electrical energy was occur for North & East North at 20° rear angle, while, for South orientation at 5°, while the other orientation was occur at 10° rear angle.And also, can notice that the roofs 20° frontal angle & 10° rear angle is consuming lowest energy for cooling with all orientation .

ةمدختسملا ةلئاملا فوقسلا هيجوتو غيير كلا من زاوية ميلفي الأبنية الهيكلية (الحديدية والخرسانية ) المشيدة في مدينة بغداد (خط عرض 33.3 درجةشما ً لا) وتأثيرها على قيمة الكسب الحراري الشمسي المنتقل خلال سقف المبنى، وتأثير ذلكعلى كمية الطاقة الكهربائية المطلوبة لتكييف تلك الأبنية صيف ًا. لذلك تم تشييد نموذج مبنى1) م يتألف سقفه من جزئين، أولهما الأمامي (تتغير زاوية ميله في x 1 x هيكلي أبعاده ( 1(5 – 45 ) درجة مع الأفق ) والآخر خلفي (تتغير زاوية ميله في الحدود ( 90 – الحدود ( 5درجة مع الأفق)، إضافة الى إمكانية دوران السقف بأكمله أفقيًا ثمان مرات.توصل الباحث الى أن العلاقة بين قيمة زاوية ميل ك ً لا من الجزء الأمامي والخلفيللسقف والتي تحقق أقل طاقة تكييف مطلوبة خلال فترة الصيف ستكون كما يلي :يماملأا ءزجلا زاوية ميل (أقل من 20 ) ، يتحقق الاستهلاك الأقل للطاقة للاتجاهالشمال، الشمال الشرقي والشمال الغربي عندما تكون زاوية ميل الجزء الخلفي 20 درجة معالأفق، بينما للاتجاه الشرق -الغرب و الجنوب الشرقي عندما تكون زاوية الميل 10 درجة معالأفق، بينما الاتجاهات الأخرى تكون زاوية الميل فيها 5 درجة، وعندما تكون زاوية ميلالجزء الأمامي مساوية الى ( 20 ) درجة، فنجد أن زاوية ميل الجزء الخلفي التي تحقق أقلطاقة مطلوبة لجميع الاتجاهات هي ( 5) درجة، وعندما تكون زاوية ميل الجزء الأماميللسقف أكبر من ( 20 ) درجة، ان قيمة زاوية ميل الجزء الخلفي والتي تتحقق الطاقة الأقل فيالاتجاهات الشمال، الشمال الشرقي عند ( 20 ) درجة بينما للاتجاه الجنوبي عند زاوية ميل 5درجة وبقية الاتجاهات يتحقق الاستهلاك الأقل للطاقة عند ( 10 ) درجة زاوية ميل الجزءº وخلفية 10 º الخلفي من السقف. وكذلك يتضح أن السقف الذي له زاوية ميل أمامية 20يحقق أقل طاقة مطلوبة للتكييف صيفًا.