research centers


Search results: Found 2

Listing 1 - 2 of 2
Sort by

Article
BEHAVIOR OF SHELL FOUNDATIONS ON SANDY SOIL REINFORCED WITH A CIRCULAR GEOGRID
تصرف الأسس القشرية على التربة الرملية المسلحة بالمشبك الدائري

Authors: Madhat Shakir Al-Soud --- Sawsan Akram Hassan
Journal: Journal of Engineering and Sustainable Development مجلة الهندسة والتنمية المستدامة ISSN: 25200917 Year: 2018 Volume: 22 Issue: 5 Pages: 147-158
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

The purposes of this study are to investigate and evaluate the benefits of using of geogrids as a circular pipe of two different lengths of (20 cm and40 cm) under the footing base in improvement of bearing capacity and settlement in term of the bearing capacity ratio (BCR) and the settlement reduction factor (SRF). A load-frame assembly was designed for the experimental work. Two types of aluminum rigid foundation were used; flat footing and shell footing of dimensions (20× 20 cm) and different angles of (20˚, 30˚, and 45˚) for shell. Sand rainer device technique was used to fill the tank to obtain a homogenous sandy soil. The result show that using a circular geogrid with a length (H=20cm) leads to increase the BCR by (14-41)% higher than that for unreinforced sand, while increasing the geogrid length to 40 cm leads to increase BCR by (6-19)% .The SRF for a certain footing decreases with decreasing the geogrid length from 40 cm to 20 cm by (11-21) % .This may be related to the punching effect caused by the longer geogrid through the loose sand stratum.


Article
Improvement of Sandy Soil with Cylindrical Cavity by Using Geogrids

Author: Laith Jawad Aziz
Journal: Journal of University of Babylon مجلة جامعة بابل ISSN: 19920652 23128135 Year: 2014 Volume: 22 Issue: 2 Pages: 325-345
Publisher: Babylon University جامعة بابل

Loading...
Loading...
Abstract

This study is focuses with the possibility of using Tanser SS2 geogrid as a reinforcement material to increase the bearing capacity and reduce settlement under strip foundation located on sandy soil with cylindrical cavity. Forty five laboratory model tests were conducted using a steel box with 1250 mm in length, 800 mm in depth and 250 mm in width. Increment loads were applied on strip footing with 100 mm in width and 250 mm in length. Since the length of the model foundation was approximately the same as the width of the test box and length of the cavity, it can be assumed that an approximate plane strain condition exist during the tests. For each model, the relationship between the applied pressure and the corresponding settlement was detected. From the results of a series of laboratory tests, it was found that the bearing capacity ratio (BCR) of the soil increases with increasing in width of geogrid, (b/d) specially when the cavity center coincides with the centerline of the strip footing (X/d=0). The effect of geogrid width will reduce with moving the cavity away from the strip footing. When the width of the geogrid layer was high (b/d), the maximum increase in bearing capacity ratio can be noticed at high depth of geogrid layer (h/d=3), and this bearing capacity ratio becomes very low at small geogrid width for same value of (h/d=3). At zero lateral distance ratio (X/d) and two layer reinforced, the higher generated bearing capacity are noted when the vertical distance between two layer geogrid is (S/d=1, i.e optimum value), but at (S/d=0.5), the values of footing resistance are lowest. The effects of number of layer (N) on the bearing capacity of strip footing are very small at low value of geogrid width. At geogrid width (b/d >1), the case of geogrid (N=3, i.e optimum value) record the highest values of the bearing capacity ratio. The location of peak strain readings of the geogrid surface is depends upon the cavity position. As the geogrid layers were near to the base of the footing, the values of reinforcement strains were increased.

هذا البحث يركز على إمكانية استخدام التسليح Geogrid Tanser SS2 لزيادة قابلية تحمل التربة و لتقليل الهبوط أسفل أساس شريطي موجود فوق تربة رملية حاوية على فجوات. خمسة و أربعون موديل مختبري تم انجازه باستخدام حاوية حديدية ذات طول ( 1250 ملم وعمق 800 ملم و عرض 250 ملم). تحميل تراكمي يسلط على أساس شريطي ذي عرض( 100 ملم و طول 250 ملم). الطول لموديل الأساس يكون مساوي إلى عرض الحاوية الحديدية و بدوره يكون مساوي إلى طول الفجوة و في هذه الحالة يمكن فرض الحالة كتشوه سطحي تقريباً و لجميع الفحوصات. لكل فحص العلاقة بين الإجهاد المسلط و النزول المناظر له تكون مقاسة.من النتائج لمجموعة الفحوصات المختبرية يمكن أن نجد بان نسبة قابلية التحمل للتربة تزداد مع زيادة عرض الجيوكرد و خصوصاً عندما مركز الفجوة ينطبق مع مركز الأساس الشريطي. التأثير لعرض الجيوكرد سوف يقل مع ازاحة الفجوة بعيدا عن الأساس الشريطي. عندما يكون عرض طبقة الجيوكرد كبير، قيمة نسبة قابلية التحمل تكون قصوى و يمكن أن نلحظها عند نسبة عمق كبيرة مساوية إلى ( 3 ) ، و قيمة نسبة قابلية التحمل تصبح ذات قيمة واطئة جداً عندما يكون عرض الجيوكرد صغير عند نفس قيمة نسبة العمق ( 3 ). عندما تقع الفجوة أسفل مركز الأساس و عندما يتم تسليح التربة بطبقتين من الجيوكرد، أعلى نسبة لقابلية تحمل التربة يمكن تسجيلها عندما تكون نسبة البعد العمودي بين الطبقتين مساوي إلى (1)، و لكن عندما تكون نسبة البعد العمودي بين الطبقتين مساوي (0.5)، القيم لمقاومة الأساس تكون الأصغر. التأثيرات لعدد الطبقات على قابلية التحمل لأساس مستمر تكون صغيرة جداً عند قيم واطئة لعرض الجيوكرد. و عندما تكون قيم عرض الجيوكرد اكبر من واحد، فان الموديل الحاوي على ثلاث طبقات سيسجل أعلى قيم لنسبة قابلية التحمل. الموقع لأقصى انفعال يتولد على سطح الجيوكرد يعتمد على موقع الفجوة الأفقي. كلما طبقات الجيوكرد تكون قريبة من قاعدة الأساس الحصيري، القيم لانفعالات التسليح تزداد.

Listing 1 - 2 of 2
Sort by
Narrow your search

Resource type

article (2)


Language

English (2)


Year
From To Submit

2018 (1)

2014 (1)