The Effect of Impinging Jet on the Flow and Heat Transfer from Isothermal Moving Plate
ثاتير النفث الاصطدامي على الجريان وانتقال الحرارة من صفيحة متحركة وبدرجة حرارة ثابتة

Author: Dr. Ahmed Waheed Mustafa د. أحمد وحيد مصطفى
Journal: AL Rafdain Engineering Journal مجلة هندسة الرافدين ISSN: 18130526 Year: 2011 Volume: 19 Issue: 6 Pages: 73-83
Publisher: Mosul University جامعة الموصل

Loading...
Loading...
Abstract

AbstractThe effect of impinging uniform jet on flow and heat transfer over isothermal moving plate is investigated. The flow and temperature fields are studied numerically with different jet velocity ratio (jet to plate velocity ratio 0-5). The laminar flow field is analyzed numerically by solving the steady, two-dimensional incompressible Navier-Stokes and energy equations. A collocated (non-staggered) grid is used in the momentum equations, which discretized by finite volume method, SIMPLE algorithm is used to adjust the velocity field to satisfy the conservation of mass. The range of Reynolds number is (Re = 10 - 100). The results show that at high jet velocity ratio (V/U = 5) and Reynolds number (Re = 100), the rate of heat transfer from the plate is doubled.

ثاثير النفث الاصطدامي المنتظم على الجريان وانتقال الحرارة من صفيحة متحركة بدرجة الحرارة ثابتة تمت دراستة. حقل الجريان ودرجة الحرارة تم دراسته عدديا عند نسب سرع نفث مختلفة (نسبة سرعة النفث الى سرعة الصفيحة تتراوح من 0 الى 5). حقل الجريان الطباقي وحقل درجة الحرارة تم تحليليه عدديا بحل معادلات نافير ستوك المستقرة والثنائية الابعاد وكذلك معادلة الطاقة المستقرة والثنائة الابعاد. تم استحدام شبكة متحدة الموقع لتقطيع معادلات الزخم باستخدام طريقة الحجم المحدد. خوازمية (SIMPLE) استخدمت لتصحيح حقل السرع لتحقيق حفظ الكتلة. مدى رقم رينولد هو (10-100) . بينت النتائج انه عند نسبة سرعة نفث عالية (V/U =5) ورقم رينولد (Re =100) فأن معدل انتقال الحرارة من الصفيحة يتضاعف.


Article
INVESTIGATING INDOOR AIR QUALITY AND THERMAL COMFORT USING DIFFERENT VENTILATION SYSTEMS UNDER IRAQI CLIMATE
استقصاء نوعية هواء الغرفة والراحة الحرارية للشاغلين باستخدام منظومات تهوية مختلفة عند ظروف الاجواء العراقية

Loading...
Loading...
Abstract

Computational Fluid Dynamics (CFD) of indoor environment as well as quality considerations are important element in the study of energy consumption, thermal comfort and indoor air quality in buildings. This paper investigate a comparison work between impinging jet, displacement, and mixing ventilation systems for an isothermal and non-isothermal ventilated room for Indoor Air Quality (IAQ) and thermal human comfort under Iraqi climate. For IJV system, draught discomfort is the issue of most concern since it supplies cooled air directly to the occupied zone. This study investigated a number of factors influencing draught discomfort and temperature stratification in an office environment. The considered factors, supply airflow rate and supply air temperature. RNG K-Ɛ turbulence model was used with the turbulent flow. The second aspect included numerical analyses by adopting ANSYS FLUENT15 code to generate simulation models. A square shaped air supply device was used with [0.1 times room height (h)] outlet terminal height from the foot level end. The IJV system proved more efficient than displacement and mixing ventilation systems. The Air Distribution Performance Index (ADPI) obtained for an isothermal and non-isothermal ventilated room adopting IJV system gave best values (0.80, 0.83) respectively compared with the other two ventilation systems.

يعتبر استخدام محاكاة ديناميك الموائع لاستقصاء البيئة الداخلية ونوعية هواء الحيز المشغول من المواضيع المهمة المطبقة حديثا في دراسات استهلاك الطاقة والراحة الحرارية للشاغلين ونوعية هواء الغرفة. تقدم الدراسة الحالية أسلوب مقارنه بين ثلاثة أنواع من منظومات التهوية الشائعة الاستخدام (نظام تهوية البثق المؤثر , نظام التهوية الازاحيه , ونظام التهوية المختلط) لنوعين من الغرف المكتبية , الأولى غرفه معزولة حراريا والثانية غرفه غير معزله حراريا لتحديد ايهم افضل عند حساب نوعية هواء الغرفة منظومة التهوية بأسلوب البثق المؤثر استخدمت مجرى تجهيز هواء ذو مقطع عرضي مربع الشكل وكان بعد فتحة تجهيز الهواء للغرفة عن أرضية الغرفة يساوي (0.1h) . أظهرت النتائج ان أسلوب التهوية باستخدام نظام البثق المؤثر أفضل من المنظومات الأخرى من خلال حساب كفاءة التهوية وحساب مؤشر أداء توزيع الهواء .