research centers


Search results: Found 6

Listing 1 - 6 of 6
Sort by

Article
Acute stress, salivary cortisol and calcium ions, in patients undergoing dental extraction procedure

Author: Dr. Hani Radhi B.D.S. M.Sc. * د. هاني راضي
Journal: MUSTANSIRIA DENTAL JOURNAL مجلة المستنصرية لطب الاسنان ISSN: 18138500 Year: 2014 Volume: 11 Issue: 1 Pages: 111-121
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

Stress is well approved to be co-related to the dental extraction procedure, andlinked to the increase in cortisol levels in patients undergoing dental treatments. Boneaffected vastly by exposure to cortisol and that is mainly due to scavenging ofminerals (calcium and phosphorus) from the bone by cortisol to be consumed as a fueland energy source in the process of gluconeogenesis; hence, alter the density of boneand can cause substantial deterioration in bone quality and quantity. Cortisol can beinfluential on the function of both the osteoblasts and the osteoclasts and that willdemonstrate significant changes on bone as well. This research investigated therelation between the levels of cortisol and calcium ions with the degree of stressbefore and after routine dental extraction.Fifty two participants were included in this study, all met the inclusion andexclusion criteria designated for the research; they were subdivided into 2 groups, firstgroup was admitted to salivary cortisol evaluation, and salivary calcium ions wereachieved for the second group.The collected data represent a significant increase in both salivary cortisol andsalivary calcium ions in the post – dental extraction group when compared to the preextractiongroup. The evaluated salivary cortisol with mean of 4.589± 0.819 mmol/Lfor pre- extraction while, in the post-extraction the mean was 5.364 ± 1.017 mmol/Lwith a significant changes. The salivary calcium ions mean were 5.66 ±0.985mmol/L, while for the post-extraction mean was 6.380± 1.161 mmol/L with asignificant changes .The findings of this research gave an insight that stress plays an essential role inaltering both salivary calcium ions and cortisol levels in the post-extraction period, asboth increased significantly.


Article
Blood Glucose Level Intraoperatively and Effect on Recovery from General Anesthesia in Non-Diabetic Recipient in Renal Transplant Surgery

Author: Alaa Hussein Altaiee*, Raghad Hannon Alsudani**, Bushra khalid Altamimi***
Journal: Iraqi Academic Scientific Journal المجلة العراقية للاختصاصات الطبية ISSN: 16088360 Year: 2018 Volume: 17 Issue: 2 Pages: 109-113
Publisher: The Iraqi Borad for Medical Specialization المجلس العراقي للاختصاصات الطبية

Loading...
Loading...
Abstract

ABSTRACT:BACKGROUND: Blood glucose increment during surgery is part of stress response, this increment is due to insulin dysfunction and glucose production and hyperglycemia increases complications.OBJECTIVE:Assess glucose level change intraoperatively and effect on recovery in non-diabetic recipients in renal transplant surgery.PATIENTS AND METHODS:52 patients from 1-1-2016 to 1-3-2017 In renal transplant center. all with standardized anesthetic technique, monitoring of blood glucose pre-induction and every half hour, soluble insulin start to be given for patient when blood glucose reach 200mg/dl as 1 unit for each 10 mg above 200 and recovery assessed using aldrete score.RESULT: There is variable increase in blood glucose among patients, 39/52 above 110 mg/dl at pre induction,1 patient was 276mg. 18/52 had 200-250 mg at least once among them,11patients reached 250-300mg,6 patients300-400 and 3reahed above400. 5 patients had delayed recovery with no significance relation to pre-induction level but significant to other readings, risk assessment showed more odd’s ratio for delayed recovery in high glucose reading and assessment of increment from pre-induction is a valid test for delayed recovery.CONCLUSION: Blood glucose measurement is mandatory in non-diabetic in renal transplant recipients..


Article
The effects of stress to the occupations of Internal environment
العوامل المؤثرة في خلق حالة التوتر لدى مستخدمي الفضاءات الداخلية

Authors: Asma H. Al-Dabbagh اسماء حسن الدباغ --- Ghada M.Yonis غادة محمد يونس --- Omar Adel Sabah عمر عادل صباح
Journal: AL Rafdain Engineering Journal مجلة هندسة الرافدين ISSN: 18130526 Year: 2009 Volume: 17 Issue: 1 Pages: 54-67
Publisher: Mosul University جامعة الموصل

Loading...
Loading...
Abstract

AbstractThis article is concern of physical environment that effects of indivsual behavior whose occupy it. Stress is one of these reflections which integrate by indivsual needs and coping resources. There are few design characteristics that have the potential to challenge human adaptive spatial resources, stress occurs when there is difficult predictability of misaffordances of internal environment. The results of this articles is that the arrangement of boundaries and the openness of the perimeters affect, to the predictability.Key words: stress, predictability, internal environment.

الخلاصةتناول البحث ماهية الانعكاسات السيكلوجية لمفردات وخصائص البيئة الداخلية للعمارة على نفسية وسلوك الافراد المستخدمين لها والكيفية التي تؤثر بها تلك الخصائص على الحالة المزاجية او الانفعالية للافراد ، ومن اهم تلك الانعكاسات هي التوتر او مشاعر القلق التي تتولد عن ضعف التكييف البيئي مع معطيات البيئة مما يؤدي الى انسحاب الافراد وتراجعهم ونفورهم منها . وقد اعتمد البحث قياس مستوى التوتر لدى الافراد بدلالة احد الظواهر السلوكية المهمة التي يتصرف بها الفرد لحظة اختراقه او تعامله مع البيئة وهي التنبؤ الآني لمفردات وبنية المنظومة الفضائية ككل . وقد استنتج البحث ان بعض الخصائص الفيزياوية للبيئة الداخلية تحدد من امكانية او صعوبة التنبؤ الآني وهي كل من خاصية انتظامية المخططات او اقترابها من الشكل المنتظم وخاصية انفتاحية الحدود والمجاورات المكونة لبنية المنظومة الفضائية. الكلمات الدالة : التوتر ، التنبؤ الآني ، البيئة الداخلية


Article
ELECTRICAL STRESS CONCENTRATION AT THE TERMINALS OF M.V. & H.V. XLPE CABLES
تركيز الاجهادات الكهربائية عند منطقة الاطراف لقابلوات البولي اثيلين متقاطع الاواصر ذوات الفولتية المتوسطة و العالية

Authors: Farook kh. Amori أ. فاروق خليل عموري --- Saad Samuel Sheet سعد صاموئيل شيت
Journal: AL Rafdain Engineering Journal مجلة هندسة الرافدين ISSN: 18130526 Year: 2006 Volume: 14 Issue: 1 Pages: 39-46
Publisher: Mosul University جامعة الموصل

Loading...
Loading...
Abstract

AbstractLongitudinal and radial stresses in a M.V. and H.V. cables through terminalsare computed using Schwarz Christoffel transformation for field sketching.The terminals and associated cable are rated at 11KV, 33KV and 132KV a.cinsulated by cross–linked polyethylene (XLPE). The electrical field sketching at thecable terminations is carried out theoretically and the results are confirmed byexperiments.It seems that the maximum stresses occurs in the cable insulation and themaximum longitudinal stresses along the screened outer surface of the cross-linkedpolyethylene (XLPE) insulation occurs between the cable and the termination center.The results show that the maximum longitudinal stress is many times theoncorrespding maximum radial values.Key Words: Stress distribution for XLPE cable, Termination of XLPE cables

منطقة الأطرافباستخدام تحويلة شوارتز كرستوفل الخاصة لرسم المجال الكهربائي .إن أطراف القابلوات كانت بمقننات 11 كيلو فولت ، 33 كيلو فولت و 132 كيلو فولت بفولتية متناوبةو ذوات عوازل البولي اثيلين متقاطع الأواصر ، تم رسم المجال الكهربائي لأطراف القابلوات بالطريقة النظرية وتم تأكيد من صحة النتائج النظرية عن طريق النتائج العملية المبينة .من النتائج العملية و النظرية يمكن القول بان اعظم إجهاد يحدث في عازل القابلو وان اعظم إجهاد طولييحدث عند السطح الخارجي لطبقة الشبه موصل الداخلية الفاصلة بين الموصل و عازل البولي اثيلين متقاطعالأواصر .و من النتائج المبينة بالتحليل النظري و كذلك من الجزء العملي يمكن القول بان اعظم إجهاد طولي يكونعادة عدة أضعاف من قيمة اعظم إجهاد قطري .


Article
Stress AnalysisoftheAbove-Knee ProsthesisduringGait Cycle
تحليل الأجهادات لوقب الطرف الصناعي أعلى الركبة خلال الخطوة الواحدة

Author: BakrNooriKhudher بكر نوري خضر
Journal: AL Rafdain Engineering Journal مجلة هندسة الرافدين ISSN: 18130526 Year: 2012 Volume: 20 Issue: 6 Pages: 48-59
Publisher: Mosul University جامعة الموصل

Loading...
Loading...
Abstract

AbstractIn this paper the finite element analysiswas achieved on the above-knee prosthesis to investigate a picture of stress distribution in the socket.Previous works on the prostheses used the symmetry approximationinshape modeling and most of them are all about static loading.The analysisand shape modeling in this work were achieved in high accuracy with theaid of ANSYS 12.1 package software capabilities. Ofthis study, stressanalysis was achieved under dynamic loading at the three main gait cycle;soon after heel strike, foot flat and just before tow off as traditional stagesused in researches. This work lies on the dynamic loading calculated withthe ground reaction forces, dynamic forces, and moments as well as theangular and linear acceleration of foot up to the thigh during the three maingaitcycle.The stress distribution was achieved and it is imported to note that themaximum stress induced in the socket are at the upper brim whereas mostparts of the socket are consi-dered as a low stress region.Key Words: stress, dynamic loading, socket , prosthesis, above knee, finite element

الخلاصةفي هذا البحث تم أجراء عملية تحليل العناصر المحددة لوقب الطرف الصناعي أعلى الركبةلمعرفةخارطة توزيع الأجهادات المتولدة خلال الطرف. أجريت الأعمال السابقة على هذا النوع من الطرفباستخدام الشكل المتماثل كما كان التركيزكثيرا على حساب الأجهادات بتأثير الأحمال الساكنة.في هذه الدراسة كانتعملية التحليل ونمذجة شكل الوقب قريبة جدا من الشكل الحقيقي بالاستفادةمن ألإمكانيات الكبيرة لبرنامج(ANSYS12.1). تضمنت الدراسة عملية تحليل للأجهاداتبتأثير الأحمال الحركية عندالمراحل الرئيسية الثلاثة للخطوة وهي مرحلة ماتلي مباشرة ضربالكعب الأرض ومرحلة تسطح القدم والمرحلة التي تسبقبقليل ابتعاد أصابع القدم عن الأرض وهيمراحل تقليدية دأب عليها الباحثون. واعتمدت الدراسة على حساب الحمل الحركي بحساب قوى ردالفعل الأرضي والقوى والعزوم الحركية المصاحبة للتعجيل الخطي والدورانيمن القدم صعودا الىعظم الفخذ عند المراحلالرئيسية الثلاثة للخطوة. تم الحصول على صورة توزيع الأجهادات علىالمناطق المختلفة للوقب ولوحظ أن قيمها العظمى تركزت في منطقة الحافة العليا فيما تميزت معظمالمناطق الأخرى بأنها ذات مستويات أجهاد متدنية


Article
Weight Optimization of Syme Socket Prosthesis
الوزن الامثل لوقب الطرف الصناعي : "سايم"

Author: Bakr Noori Khudher بكر نوري خضر
Journal: AL Rafdain Engineering Journal مجلة هندسة الرافدين ISSN: 18130526 Year: 2013 Volume: 21 Issue: 3 Pages: 59-65
Publisher: Mosul University جامعة الموصل

Loading...
Loading...
Abstract

Abstract In this paper the finite element analysis was achieved on the Syme socket prosthesis to know the possibility of weight reduction of the socket. Previous works were restricted to stress analysis and socket-stump pressure distribution. In this work, the maximum stress induced in the socket model was found out at the maximum load carrying capacity that is developed at push-off stage of gait. The stress calculated is less than the yield and ultimate strength of the socket material, from which the optimum weight of the socket is obtained. The weight reduction of the socket is achieved by decreasing its thickness. At this point, the maximum stress is calculated again at the same loading condition as before reducing the weight. The maximum calculated stress is still less than the yield stress of the socket material. As a result, further weight reduction is achieved and hence the overall cost can be minimized by saving the expenditure on the material. Besides, the patients will feel comfort with light weight sockets. Key Words: stress, Syme, socket, prosthesis, finite element, weight optimization.

الخلاصة في هذا البحث تم أجراء عملية تحليل العناصر المحددة لوقب الطرف الصناعي "سايم" لمعرفة امكانية تقليل وزن الوقب من دون التأثير على الوظائف الرئيسية للوقب. لقد اقتصرت الاعمال السابقة على تحليل الاجهادات خلال الوقب او معرفة توزيع الضغط ما بين الوقب والجدعة. تم في هذا العمل ايجاد الاجهادات القصوى المتولدة في الوقب عند اعظم حمل يتعرض له الوقب. لوحظ ان هذا الاجهاد هو دون اجهاد الخضوع لمادة الوقب, وعليه اصبح بالامكان تقنين كمية المادة المستخدمة في صناعة الوقب وذلك بتقليل سمكه. عند هذه النقطة تم حساب الاجهادات العظمى مرة اخرى عند السمك الجديد وعند نفس الظروف. هذه الاجهادات لم تزل دون اجهادات الخضوع. كنتيجة لهذه الدراسة امكن التوصل الى تقليل وزن الوقب الذي سيؤدي حتما الى تقليل الكلفة عن طريق الاقتصاد في صرف المادة المستخدمة في صناعة الوقب. اضافة الى الراحة التي سيشعر بها المريض وهو يستخدم وقبا خفيف الوزن.الكلمات المفتاحية: الاجهاد, سايم, وقب, العناصر المحددة, الوزن الامثل.

Listing 1 - 6 of 6
Sort by
Narrow your search

Resource type

article (6)


Language

English (5)

Arabic (1)


Year
From To Submit

2018 (1)

2014 (1)

2013 (1)

2012 (1)

2009 (1)

More...