research centers


Search results: Found 4

Listing 1 - 4 of 4
Sort by

Article
Behavior of Cantilever Beams in R.C. Frames with Effect of Steel Fibers in Beam – Column Joint

Author: Mohanad Salih Farhan مهند صالح فرحان
Journal: DIYALA JOURNAL OF ENGINEERING SCIENCES مجلة ديالى للعلوم الهندسية ISSN: 19998716/26166909 Year: 2018 Volume: 11 Issue: 4 Pages: 14-19
Publisher: Diyala University جامعة ديالى

Loading...
Loading...
Abstract

This paper aims at investigating the behavior of cantilever beam in reinforced concrete frame modified by steel fibers. The study depends on adding steel fibers at the joint of beam column section to improves the ductility of the beam – column joint. Steel fibers of ratio (0.5%) and (1%) steel fibers by volume added for two specimens comparing with two others cast without steel fibers joint in R.C. frame. The cantilever frame behavior at applied load will be discussed in this study. The load applied to the frame at the edge of cantilever arms. The test results showed that the difference between the monolithic frame is larger in ultimate loads compared with non-monolithic, and the frame with 1% steel fibers have large load capacity compared with 0.5% steel fibers frame. The frame which cast monolithically shows highest resistance among the three other frames in ultimate load and flexural deformation, after load was applied to the four specimens the behavior of the frame up to the failure occurred in the beam-column joint at exterior face of the cantilever. beside studying the effect of steel fibers percentage and behavior of beam column joint, this study focuses also on investigating the difference between monolithic and non-monolithic concrete elements.


Article
Modeling of Single Channel Monolithic Reactor with The Single pass Flow Operation System
نمذجة المفاعل المونولوثي وحيد القناة بنظام جريان الممر الواحد

Authors: Lange, R --- Zaidoon, M. --- Jenan, A Al-Najar --- Adel, A. Shuhaib
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2010 Volume: 28 Issue: 11 Pages: 2221-2236
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

In the following sections, the recent published studies on modeling andsimulation of monolith reactors were reviewed. Mass transfer, and reaction kineticswere achieved by establishing mass, energy and momentum balance equations. Themodel equations were solved simultaneously. Such a model can be useful for studyingthe impact of changes of superficial gas and liquid velocities on reaction rate withinthe slug flow regime. The reaction system used is the hydrogenation α–methyl styrene(AMS) to cumene over a palladium on γ–alumina catalyst, It is a well knownsystem used to understand three-phase reactor performance under mass transferlimited condition by the gas mass transfer through the liquid film at the catalystsurface to the active sites. The effects of superficial gas and liquid velocities onreaction rate were studied with the range of 10 cm/s ≤ UL ≤ 30 cm/s, and 10 cm/s≤ UG ≤ 30 cm/s. The flow pattern for all these range of velocities was in the Taylorflow pattern.

في هذه الدراسه تم اجراء عرض للدراسات المنشوره الحديثه عن نمذجة وتمثيل مفاعلاتالمونولث. انتقال الكتله و حركية التفاعل يمكن التوصل اليها من خلال معادلات موازنة الكتله,الحرارة والزخم. حلت معادلات الموديل بشكل اني, مثل هذا النموذج يمكن ان يكون مفيد لدراسةنظام التفاعل المستخدم .(Slug flow regime) تأثير سرعة انتقال الغاز والسائل ضمن نظام تدفقالى الكيومين, فوق البلاديوم المحمل على الكاما الومينا كعامل (AMS) هو هدرجة الفا مثيل ستايرينمساعد, انه نظام معروف جيدا يستخدم لفهم اداء المفاعلات ثلاثية الطور تحت ظروف انتفال كتلهمحدده بانتقال الغاز خلال طبقة السائل الرقيقه على سطح العامل المساعد الى المواقع الفعاله. تأثير10 , و 10 cm/s ≤ UL ≤30 cm/s سرع الغاز والسائل على معدل التفاعل تم دراستها ضمن حدود(Taylor Flow نوع الجريان لكل حدود السرع هذه هو نظام جريان .cm/s ≤ UG ≤30 cm.Pattern


Article
Behavior of Reinforced Hybrid Concrete Corbel-Column Connection with Vertical Construction Joint

Authors: Ammar Yasir Ali --- Waseem Hamzah Mahdi
Journal: Journal of University of Babylon مجلة جامعة بابل ISSN: 19920652 23128135 Year: 2017 Volume: 25 Issue: 1 Pages: 30-44
Publisher: Babylon University جامعة بابل

Loading...
Loading...
Abstract

In this paper, shear behavior of reinforced hybrid concrete connection of corbel-column is experimentally investigated. Nine homogenous and hybrid concrete corbel-column connections subjected to vertical applied loads were constructed and tested within two test groups (A, B). The experimental program included the effect of several variables such as type of hybrid concrete;high strength concrete (HSC) or steel fiber reinforced concrete (SFRC), monolithic casting of hybrid concrete connection, and presence of construction joint at the interface of corbel-column. Experimental results showed significant effects of concrete hybridization on the structural behavior of connection specimens such as: ultimate strength, cracking loads, cracking patterns, and failure modes. Hybridization process in group (A) included hybrid connection of corbel-column with HSC or SFRC corbel instated of NSC. This process led to increase the capacity of connection by (26%, 38%) and shear cracking loads by (20%, 120%) respectively. Moreover, connections of hybrid concrete corbels cast monolithically improved the shear capacity of corbels by (19%, 42%) for HSC or SFRC respectively. In group (B), presence of construction joint at connection region reduced the shear capacity of connectionsby (10% to 22%) and cracking loads by (23%-62%) compared with connections cast monolithically.

تقدم هذه الدراسة تقصيا عمليا لسلوكمنطقة الاتصال بين العمود والكتف والمكونة من الخرسانة الهجينة. تضمنت الدراسة انشاء وفحص تسعة من نماذج الكتف الخرساني المرتبط بعمود الهجينة والمتجانسة تحت تأثير احمال عمودية ضمن مجموعتينA,B)).تضمن البرنامج العملي تأثير عدة متغيرات مثل نوع الخرسانة الهجينة;خرسانة عالية المقاومةHSC)) او الخرسانة الحاوية على الالياف الفولاذية (SFRC),الصب الموحد لمنطقة الاتصال الهجينة ,وجود مفصل انشائي في منطقة التداخل بين العمود والكتف. بينت نتائج الدراسة العملية وجود تأثيرات مهمة لتهجين الخرسانة على التصرف الانشائي لنماذج الاتصال من حيث: المقاومة القصوى ,احمال التشقق, نمط التشقق, شكل الفشل. عملية التهجين في المجموعةA)) تضمنت انشاء منطقة اتصال هجينة بين الكتف والعمود عن طريق صب الكتف بخرسانة عالية المقاومة او حاوية على الياف فولاذية بدلا من الخرسانة ذات التحمل الاعتياديNSC)).تؤدي هذه العمليةالى زيادة مقاومة منطقة الاتصال بحوالي26%, 38%)) واحمال تشققات القص بحوالي 20%, 120%)) على التوالي.اضافة الى ذلك , تزداد مقاومة القص في مناطق الاتصال ذات الاكتاف الخرسانية الهجينة التي تم صبها في وقت واحد بحوالي 19%-42%)) للأكتاف المهجنة بالخرسانة عالية المقاومة او الخرسانة الحاوية على الالياف الفولاذية على التوالي. في المجموعة B)),وجود مفصل انشائي في منطقة الاتصال يقلل من مقاومتها للقص بحوالي(10%-41%) واحمال التشقق بحوالي((23%- 62% مقارنة بمناطق الاتصال التي تم صبها في وقت واحد.


Article
Behavior of Reinforced Concrete Hybrid Trapezoidal Box Girders Using Ordinary and Highly Strength Concrete

Authors: Nameer A. Alawsh --- Teeba Haider Mehdi
Journal: Journal of University of Babylon مجلة جامعة بابل ISSN: 19920652 23128135 Year: 2018 Volume: 26 Issue: 5 Pages: 272-278
Publisher: Babylon University جامعة بابل

Loading...
Loading...
Abstract

In this paper, the general behavior of reinforced concrete hybrid box girders is studied by experimental and numerical investigation. Experimental work is included casting monolithically five specimens of box girders with trapezoidal cross section and testing it as simply supported under two point loading. Two specimens were cast as homogenous box girders (full normal strength concrete (NSC) (about 35MPa) and full high strength concrete (HSC) (about 55MPa)) and three specimens were cast as hybrid box girders (HSC in upper flange only, HSC in upper flange and half depth of webs, and HSC in bottom flange and total depth of webs). Experimental results showed significant effects of concrete hybridization on the structural behavior ofbox girders specimens such as: cracking loads, cracking patterns, ultimate strengths, and failure modes. The ultimate strength of Hybrid box girders increased by 23% as average when compared with the homogenous box girder (full NSC) and decreased by 9% as average when compared with homogenous box girder (full HSC). In numerical investigation, the tested specimens were modeled and analyzed using three dimensional non-linear finite element analysis. The analysis was carried out by using a computer program (ANSYS V16.1). The numerical results showed an acceptable agreement with the experimental work with difference about (3.12% and 9.588%) as average for ultimate load and deflection, respectively.

تم في هذا البحث دراسة التصرف العام للروافد الخرسانية المسلحة ذات المقطع الصندوقي والمصنوعة من الخرسانة الهجينة (نوعين مختلفين من الخرسانة تصب ككتلة واحدة) عمليا ونظريا. تضمن الجزء العملي انشاء وفحص خمسة نماذج من الروافد الصندوقية مع مقطع شبه منحرف تحث تأثير فحص نقطي ثنائي التحميل. نموذجان من المقاطع الصندوقية تم صبهما من الخرسانة المتجانسة (احدهما من خرسانة عادية المقاومة (35MPa) والاخر من خرسانة عالية المقاومة (MPa55)) وثلاثة نماذج من الخرسانة الهجينة (خرسانة عالية المقاومة في: الشفة العليا فقط, الشفة العليا ونصف عمق الوترة, و الشفة السفلى والعمق الكلي للوترة). بينت نتائج الدراسة العملية وجود تأثيرات مهمة لتهجين الخرسانة على التصرف الإنشائي لنماذج الروافد الصندوقية من حيث: احمال التشقق, نمط التشقق, المقاومات القصوى, و اشكال الفشل. المقاومة القصوى للروافد الصندوقية ذات الخرسانة الهجينة ازدادت بنسبة حوالي 23% كمعدل بالمقارنة مع الروافد الصندوقية ذات الخرسانة المتجانسة (خرسانة عادية المقاومة) وقلت بنسبة حوالي 9% فقط. في الجزء النظري من الدراسة تم تمثيل وتحليل النماذج المفحوصة بشكل رقمي باستخدام طريقة العناصر المحددة. النماذج الرقمية تم تكوينها بثلاثة أبعاد باستخدام برنامج إلكتروني (ANSYS الإصدار 16.1). أظهرت النتائج النظرية (التحليلية) توافقا معقولا مع النتائج العمليةبنسبة اختلاف (3.12% و 9.588%) كمعدل بالنسبة للحمل الاقصى والهطول, على التوالي.

Listing 1 - 4 of 4
Sort by
Narrow your search

Resource type

article (4)


Language

English (4)


Year
From To Submit

2018 (2)

2017 (1)

2010 (1)