research centers


Search results: Found 81

Listing 1 - 10 of 81 << page
of 9
>>
Sort by

Article
Ions release from fixed orthodontic appliance in two different mouthwashes

Authors: Reem Atta Rafeeq ريم عطا رفيق --- Alan Issa Saleem الان عيسى سليم --- Layth M. K. Nissan ليث محمد كريم
Journal: Journal of baghdad college of dentistry مجلة كلية طب الاسنان بغداد ISSN: 16800087 Year: 2014 Volume: 26 Issue: 4 Pages: 152-155
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Background: Metal ions can be released from metallic orthodontic appliances due to corrosion in the oral cavity;prophylactic mouthwashes may have an effect on ion release from orthodontic wires.Materials and Methods: Thirty six orthodontic sets of half maxillary fixed appliance with 2 types of arch wires SS andNiTi(Morelli) were constructed and immersed in 2 types of mouthwashes; Claradone (non-fluoridated) and Silver Care(fluoridated) for 28 days at 37°C, then the released Ni and Cr ionswere measured using atomic absorptionspectrophotometer and compared statistically.Results: Ni ion release was higher from NiTi wire group than SS wire group for both mouthwashes and also was higherfor Silver Care group than for Claradone group. While for Cr ion was higher for Silver Care group than for Claradonegroup, with significant differences for all the groups.Conclusion: Claradone non-fluoridated mouthwash cause less release of Ni and Cr ions release from the orthodonticappliance samples than Silver Care fluoridated mouthwash

Keywords

corrosion --- mouthwash --- Ni --- Cr


Article
The Effect of Thermal Annealing on the Diffusion Profile of Nickel in GaAs Substrates
تأثير التلدين الحراري على انتشار النيكل في قواعد الكاليوم ارسنايد

Author: Aseel A.K. Hadi
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2009 Volume: 27 Issue: 5 Pages: 880-885
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

Diffusion of nickel in GaAs has been studied at 950ºC. The diffusion wasenhanced during limited interval and for different quantities of As. Nickel atomshad diffused in the beginning due to the interstitial movement of atoms but largenumber of nickel atoms occupies substantial locations in p-type GaAs lattice.Measurements performed to the samples have showed good agreement between thenickel atoms concentration and majority charge-carriers in p-type semiconductor(holes). Measurements explained that electrical conductivity of p-type samples wasnot due to system heating but to the diffusion of nickel atoms occupying sites ofgallium atoms.

في هذا البحث ، جرى دراسة أنماط انتشار النيكل في عينات من الكاليوم أرسنايد عند درجة 950 جرى تحسين الانتشار من خلال إضافة مقادير مختلفة من الأرسنايد، إن ºC. حرارة تلدين ذرات النيكل تنتشر في بادئ الأمر بسبب الحركة البينية لها غير أن عدداً كبيراً منها يحتل مواقع استبدالية في الكاليوم أرسنايد المانح .أجريت القياسات الكهربائية للعينات وقد أوضحت تطابقاً جيداً ما بين تراكيز النيكل وتركيز الفجوات التي تعتبر حاملات الشحن الأغلبية في شبه الموصل القابل .أوضحت القياسات أن التوصيلية الكهربائية للعينات القابلة لم تكن بسبب تسخين المنظومة وإنما بسبب انتشار ذرات النيكل التي تحتل مواقع ذرات الكاليوم


Article
The Effect of Recasting on the Castability of Prepared Nickel-Chromium Dental Base-Metal Casting Alloy

Authors: Suhad Jabar Hemed سهى جبار حميد --- Mohammed Talib Al-khafagy محمد طالب الخفاجي
Journal: Al-Qadisiyah Medical Journal مجلة القادسية الطبية ISSN: 18170153 Year: 2007 Volume: 3 Issue: 4 Pages: 103-111
Publisher: Al-Qadisiyah University جامعة القادسية

Loading...
Loading...
Abstract

Background: Evaluation the effect of recasting process on the castability value of prepared Ni-Cr dental base-metal casting alloy and compare it with other conventional alloy.Materials and methods: The prepared Ni-Cr alloy was locally prepared in Iraq by Al-Khafagy (2003), while the CB Blando Ni-Cr was used as conventional alloy. A wax mash of 1mm opening and (10*10) segments square was invested in phosphate-bonded investment and casted by using induction casting machine. The number of complete cast segments was counted, divided by (220) and multiplied by (100) to obtain a percentage designated the castability value (Cv).Results and discussion: The prepared Ni-Cr alloy samples were showed lower castability values than the conventional alloy, this may be related to unalloyed silicon and manages and loss the role of these elements in improvement of castability of prepared Ni-Cr alloy. The castibility value was decreased as the percentage of used alloy increased, however, ANOVA test revealed a non significant differences within the groups. Practically, the experimental and conventional alloys could be recastd if the recasted process will not affect the other properties of such alloys.


Article
The influence of instrument application frequency on the apical extrusion of debris using rotary ProTaper, hand ProTaper and hybrid technique (An in vitro study)

Authors: Majida K. Al-Hashimi ماجدة الهاشمي --- Zaid K. Al-Doory زيد الدوري
Journal: Journal of baghdad college of dentistry مجلة كلية طب الاسنان بغداد ISSN: 16800087 Year: 2012 Volume: 24 Issue: 4 Pages: 34-39
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Background: Various kinds of hand-held or rotary instruments and techniques are used for mechanical preparationof the canal during root canal treatments. These instruments and techniques may push debris out of the canalswhich may induce inflammation within the periapical area; therefore, instrumentation technique that causes lessextrusion of debris is more desirable. The aim of this study was to compare the effect of instrument applicationfrequency on the amount of apically extruded debris.Materials and Methods: One hundred and twenty extracted human teeth were used in this study; all teeth wereshortened to a length of 15 mm. Each experimented root was mounted on a centrifuge tube that forced through aprecut hole in a rubber stopper of a glass vial. The roots were divided randomly into 3 groups, each group contained40 roots. Group R: prepared by rotary ProTaper, Group H: prepared by hand ProTaper, Group S: prepared by Hybridtechnique. Each group was further subdivided in to five subgroups (A, B, C, D, and E). Debris extruded from apicalforamen was collected in a centrifuge tube containing 0.5 milliliter of distilled water. Each empty centrifuge tube wasweighed before preparation by 0.0001g. sensitive weighing machine. Then at the end of canal preparation, thesecentrifuge tubes were completely dried using an incubator at 68 C° for two days and weighed again. The differencebetween the weights of tubes in two stages represented the weight of debris extruded from apical foramen duringinstrumentation.Results: No significant difference recorded for the mean weight of apically extruded debris regarding the instrumentapplication frequency within the same instrumentation technique; but there was a high significant difference for thesubgroups (A, B, C, and D) and a significant difference for subgroup E, regarding the effect of instrumentationtechniques on amount of apical extrusion of debris among tested groups.Conclusion: The hand ProTaper extruded smaller amounts of apical debris than the rotary ProTaper and largeramounts than Hybrid technique


Article
Different Shapes of Carbon Nanotubes via Water Assisted Chemical Vapor Deposition
اشكال مختلفة من انابيب الكاربون النانوية بطريقة ترسيب البخار الكيميائي بمساعدة الماء

Authors: Kahtan Kalaf Al-Khazraji --- Ali Hussain Ataiwi --- Mayyadah S. Abed Al-Fatlawi
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2015 Volume: 33 Issue: 2 Part (A) Engineering Pages: 487-499
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

Carbon nanotubes with different shapes have been prepared using water assisted chemical vapor deposition technique (WA-CVD). Different thicknesses of nickel layers were sputtered on alumina substrate. These were treated under high temperature (700 °C) at hydrogen gas to grow nickel nanoparticles (Ni-NPs). Tube furnace (single type), argon and acetylene gases were used for Carbon Nanotubes (CNTs) growth. The FESEM, TEM, HRTEM, Raman spectroscopy, and XRD were used for characterization of the carbon product. The results show that Water Assisted CVD produces CNTs with no trace of amorphous carbon. Nickel catalyst thicknesses (0.5,1,3,3.45,6.8,100 nm) offer different shapes of carbon nanotubes (single walled carbon nanotube, plain MWCNT, helical carbon nanotube, carbon nanofiber).

تم تحضير انابيب الكاربون النانوية باشكال مختلفة باستخدام طريقة ترسيب البخار الكيميائي بمساعدة الماء. حيث تم ترسيب طبقات مختلفة السمك من النيكل بطريقة التذرية على اساس من الالومينا. وقد تمت معاملتها بالهيدروجين وعند درجة حرارة عالية (700 °C). حيث تم استخدام فرن انبوبي احادي و غاز الاستيلين وغاز الاركون لتنمية انابيب الكاربون النانوية. وتم استخدام المجهر الالكتروني الماسح عالي الدقة والمجهر الالكتروني النافذ والمجهر الالكتروني النافذ عالي الدقة ومطياف رامان والاشعة السينية المنحادة لتشخيص الكاربون الناتج. بينت النتائج بان استخدام الترسيب البخار الكيميائي بمساعدة الماء ينتج انابيب كاربون بدون وجود اثر للكاربون غير المتبلور.وان اختلاف سمك طبقة المادة المساعدة (0.5,1,3,3.45,6.8,100 nm)اعطت اشكال مختلفة من انابيب الكاربون النانوية وهي انابيب الكاربون احادية الجدران ومتعددة الجدران المستوية والحلزونية، والياف الكاربون النانوية.


Article
Characterization of Ag:Ni Nano Particles Produced by Pulse Nd:YAG laser
تشخيص دقائق Ag:Ni النانوية المنتجة بواسطة ليزر النيوديميوم-ياك النبضي

Author: Ahmed Abd Al-Razza Naama أحمد عبد الرزاق نعمة
Journal: Iraqi Journal of Science المجلة العراقية للعلوم ISSN: 00672904/23121637 Year: 2017 Volume: 58 Issue: 2A Pages: 653-662
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

This work presents the characteristics of plasma produced by fundamental wavelength (1064 nm) Q- switched Nd:YAG laser on Ag:Ni alloy in distilled water were investigated at different laser energies by optical emission spectroscopy technique. The size of produced nanoparticles from Ag:Ni target in distilled water were studied, by x-ray diffraction, UV-visible absorbance and atomic force microscopy, at different laser energies. Spectroscopic measurements show that electron temperature and electron density increase with increasing laser energy. It was found from AFM measurements that the produced nanoparticle size decrease from 97.13 nm to 71.20 nm, while XRD shows that the crestalline size decrease from 15.5 nm to 9 nm with increasing pulse laser energy. UV- visible absorbance shows at plasmon peaks shifted from 410 to 395 nm with increasing laser energy.

هذا البحث هو دراسة لخصائص البلازما المنتجة عن طريق الليزر النبضي ذو محول عامل النوعية نيوديوم ياك (Nd:YAG) من سبيكة Ag:Ni في الماء المقطر عند طاقات مختلفة لليزر بواسطة تقنية التحليل الطيفي للانبعاثات. تم دراسة تأثير الطاقات المختلفة لليزر على الحجم االنانوي للدقائق المنتجة من هدف Ag:Ni في الماء المقطر باستخدام حيود الاشعة السينية و امتصاص الاشعة المرئية فوق البنفسجية ومجهر القوى الجزيئية. تبين من القياسات AFM أن حجم الجسيمات النانوية ينخفض من 97.13 إلى 71.20 نانومتر ، بينما أظهرت قياسات XRD انخفاض الحجم البلوري من 15.5 نانومتر إلى 9 نانومتر مع زيادة طاقة الليزر النبضي. يظهر طيف امتصاص الأشعة فوق البنفسجية- مرئية قمة البلازمون تزحزحت 410-395 نانومتر مع زيادة طاقة الليزر.


Article
NICKEL IONS REMOVAL FROM AQUEOUS SOLUTIONS USING SAWDUST AS ADSORBENT: EQUILIBRIUM, KINETIC AND THERMODYNAMIC STUDIES
إزالة أيونات النيكل من المحاليل المائية بإســتعمال نشارة الخشــب كوسـط ماز: دراسة الأتزان، الديناميكية الحركية والثرموداينمك

Author: Lahieb Faisal Muhaisen
Journal: Journal of Engineering and Sustainable Development مجلة الهندسة والتنمية المستدامة ISSN: 25200917 Year: 2017 Volume: 21 Issue: 3 Pages: 60-71
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

This work is concentrate on removal of some environmentally relevant contaminants, such as nickel ions from simulated wastewater by sawdust low- cost natural sorbents. Sorption batch tests were investigated in the removal process at initial concentration of nickel ions (100 mg/l).Equilibrium, kinetics and thermodynamic studies were investigated for the removal process. Parameters affect as pH, amount of sawdust, contact time and temperature were studied. The uptake capacity was 12.5 mg/g; also FTIR demonstrated that carboxyl and hydroxyl groups were involved in the adsorption of the metal ions. The results indicated that adsorption is an endothermic process and rate of removal increased with increase temperature.

ان الهدف من هذا العمل هو التركيز على ازالة بعض الملوثات البيئية )أيونات النيكل( من مياه ملوثة مُصنعة باستعمال ممتزات واطئة الكلفة وطبيعية )نشارة الخشب(.أجريت تجارب الباج (الدفعة) لازالة تركيز 100 ملغملتر من ايونات النيكل. تمت دراسة العوامل المختلفة على عملية الأمتزاز مثل قيمة الدالة الحامضية ، كمية القشور المستعملة, زمن التماس و درجة الحرارة. نتائج فحص التحليل الكيفي اظهر المجموعات الفعالة للمركبات العضوية مثل المجموعات الكربوكسيليةوالهيدروكسيل. و كانت سعة الامتزاز 12.5 ملغمغم، وكانت نسبة الأزالة تزداد بزيادة الحرارة و ذات طابع ماص للحرارة وفقا لنتائج الحرارية.

Keywords

Ni --- II ions --- sawdust --- Equilibrium --- kinetics --- thermodynamic


Article
Synthesis and Characterization Complexes of Ni(II) that Contain Cyanoguanidine and Phosphines Ligands
تحضير وتشخيص معقدات Ni(II) الحاوية على ليكاندات سيانوكوانيدين والفوسفينات

Authors: Mahmood Mahdi Salih محمود مهدي صالح --- , Ahmad A. Irzoqi احمد عبد الستار ارزوقي
Journal: Tikrit Journal of Pure Science مجلة تكريت للعلوم الصرفة ISSN: 18131662 Year: 2018 Volume: 23 Issue: 1 Pages: 92-101
Publisher: Tikrit University جامعة تكريت

Loading...
Loading...
Abstract

The ligand of Cyanoguanidine showed an important coordination formula with Ni2+ to give a complex of tetrahedral geometrical shape [Ni(CY)2Cl2] when the metal reacted with Cyanoguanidine of 1:2 ratio, and octahedral complexes of the types [Ni(CY)2(PPh3)2Cl2], [Ni(CY)2)(PPh3)4]Cl2 and [Ni(CY)2(diphos)2]Cl2 (where CY= Cyanoguanidine and diphos = dppm, dppe, dppp, dppb), since the structure depends on the conditions and type of the compounds involved in reaction.The prepared complexes were characterized by element analysis CHN, conductivity measurements and magnetic susceptibility and also identified spectrally by Ultraviolet and Infrared spectroscopy

اظهر ليكاند السيانوكوانيدين صيغه تناسق مهمة مع Ni2+ مكوناً معقداً ذا شكل هندسي رباعية السطوح من نوع [Ni(CY)2Cl2] عند تفاعل الفلز بوجود السيانوكوانيدين بنسبة 2:1 ومعقدات ثمانية السطوح من نوع [Ni(Cy)2(PPh3)2Cl2] و [Ni(Cy)2(PPh3)4]Cl2 و[Ni(Cy)2(diphos)Cl2] (حيث ان Cy=Cyanoguanidine و diphos= dppm, dppe, dppp, dppb) حيث يعتمد التركيب على ظروف والمركبات التي تدخل في التفاعل.وشخصت المعقدات المحضرة بواسطة التحليل الدقيق للعناصر(CHN) وقياسات التوصيلية والحساسية المغناطيسية وشخصت طيفيا بواسطة طيف الاشعة فوق البنفسجية وطيف الاشعة تحت الحمراء

Keywords

Complexes --- Ni --- II --- Cyanoguanidine ligand --- Phosphines


Article
INVESTIGATION SOME PROPERTIES OF (ZN-NI-SIC) COMPOSITES COATING ON LOW CARBON STEEL
تحري بعض خواص طبقة الطلاء (Zn-Ni-SiC) المترسبة على نماذج من الفولاذ واطئ الكاربون

Loading...
Loading...
Abstract

This work represents an attempt to introduce further improvement on the properties of these coatings, although the (Zn-Ni) deposition is known to be an anomalous electrodeposited process , where added Ceramic materials is (silicon carbide) ,with very good mechanical properties.Carbon steel samples were coated with (Zn-Ni) and (Zn-Ni-SiC) particles with different particles size of silicon carbide once microscale (73µm) and another nanoscale (70-100nm) .After electroplating, these samples were analyzed by X-ray fluorescent to confirm all the content for each alloy.

يهدف هذا البحث لادخال تحسينات إضافية على خواص طبقة الطلاء (Zn-Ni) ، حيث تم أضافة مادة سيراميكية هي كاربيد السيليكون التي تمتاز كمثيلاتها من المواد السيراميكية بخواصها الميكانيكية الجيدة . تتضمن هذه الدراسة التحري عن بعض خواص طلاء (Zn-Ni) بعد اضافة مادة كاربيد السيليكون بحجميها المايكروي (≈73µm) والنانوي(70-100nm) المترسبة على نماذج من الفولاذ منخفض الكاربون.تضمنت الخواص المدروسة كلا من اختبار فلورة الاشعة السينية والخشونة والمسامية واختبار الصدمة الحرارية وقد ظهر تطابق بين نتائج اختبار المسامية والخشونة حيث إن هنالك علاقة بينهما إذ ان الخشونة العالية تسبب مسامية عالية وبذلك يكون تسلسل المسامية والخشونة الموجودة في طبقة الطلاء كالاتي: (Zn-Ni) >(Zn-Ni-nSiC) >(Zn-Ni-mSiC). كما أظهرت طبقة الطلاء (Zn-Ni-nSiC) نتائج جيدة في إختبار الصدمة الحرارية.


Article
The Microstructure Properties of Ni-W Alloy Electrodeposition
الخصائص المجھریة لسبائك Ni-W المرسبة بواسطة الترسیب الكھربائي

Authors: Mofeed A. Jaleel مفید عبد اللطیف جلیل --- Eilaf Z. Gurji إیلاف زكي كرجي
Journal: AL-NAHRAIN JOURNAL FOR ENGINEERING SCIENCES مجلة النهرين للعلوم الهندسية ISSN: 25219154 / eISSN 25219162 Year: 2018 Volume: 21 Issue: 1 Pages: 82-85
Publisher: Al-Nahrain University جامعة النهرين

Loading...
Loading...
Abstract

The Electrodeposition process has been used to prepare Nickel-Tungsten alloys on low carbon steel substrate by using ammonical citrate bath. The influence of deposition condition by variation of current density (0.04-0.2 A/cm2) and solution temperature (60-70 °C), on the microstructure was studied. The optical microscope and the scanning electron microscopy (SEM) were used to study the morphology of the deposit while the energy dispersive spectroscopy (EDS) was used to approximate the composition, in addition to X-Ray diffraction examination. The results show that the current efficiency has the major influence on the tungsten content in the alloys due to the formation of ternary complex which reflected into the properties of the deposit.

أستخدمت طریقة الترسیب الكھربائي لتحضیر سبائك من النیكل- تنغستن على قاعدة من الحدید واطئ الكاربون بأستخدام -0.04) A/cm أحواض تحتوي على الأمونیا والسترایت. حیث تم دراسة تأثیر متغیرات عملیة الطلاء من حیث كثافة التیار 2 70 -60 ) على التركیب المایكروي. تم أستخدام المجھر الضوئي والماسح ) °C 0.2 ) ودرجة حرارة المحلول فقد أستخدم (EDS) من أجل قیاس البنیة المجھریة للمترسب، أما جھاز مطیاف تشتت الطاقة بالأشعة السینیة (SEM) الألكتروني (XRD) من أجل حساب التكوین التقریبي للمترسب بالأضافة الى فحص حیود الأشعة السینیة . أظھرت النتائج التأثیر الكبیرلكفاءة التیار على محتوى التنغستن في السبیكة ویعود السبب في ذلك الى تكوین المعقد الثلاثي والذي ینعكس على خصائص المترسب.

Listing 1 - 10 of 81 << page
of 9
>>
Sort by
Narrow your search

Resource type

article (81)


Language

English (67)

Arabic (11)

Arabic and English (3)


Year
From To Submit

2019 (3)

2018 (10)

2017 (9)

2016 (11)

2015 (6)

More...