research centers


Search results: Found 8

Listing 1 - 8 of 8
Sort by

Article
Nitrogen Compounds Distribution in Diyala River Opposite Al-Rustimiyah Sewage Treatment Plants

Authors: Adnan A. Al-Samawi --- Safaa N. H. Al-Hussaini
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2016 Volume: 34 Issue: 15 Part (A) Engineering Pages: 2971-2981
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

The reach of Diyala River just before its confluence with Tigris River south of the capital city Baghdad was taken as a case-study. This segment of Diyala River is exposed to multiple points of treated and raw municipal wastewater discharges of Al-Rustimiyah wastewater treatment plants. Its pollution status was assessed with regard to nitrogen compounds levels. The aquatic parameters: DO, TN, TKN NH4-N, NH3-N, NO3-N, NO2-N, pH, and temperature were monitored and measured at nine sites along the river reach for a period of one year to assess seasonal variations. The first and last sites were chosen at the downstream and upstream of the points of pollution flowing into Diyala River, while the second to eighth sites were located at the effluents of the WWTPs of Al-Rustimiyah. It was found that water at sites two, seven, and four, respectively, were the most polluted points among all duo to the presence of the bypasses from the WWTPs at these sites. With regard to NH4-N, NH3-N, and TN concentrations, the river was found to be heavily polluted with untreated wastewater at site two and between low to medium strength at other sites, except for site one. On the other hand, NO3-N and NO2-N concentrations categorized the river water as an effluent rather than a stream according to Iraqi standard classification. Reversed relations were found between the DO concentrations and some of the nitrogen compounds and temperature. A statistical model relating TN concentration to DO, NH3-N, and temperature was derived. It was proved to be accurate.

Keywords

Diyala River --- TN --- NO3-N --- NH3-N --- DO --- Temperature


Article
Evaluation the efficiency of the plant Hammdan wastewater treatment in the province of Basrah
تقییم كفاءة محطة حمدان لمعالجة میاه الصرف الصحي في محافظة البصرة

Loading...
Loading...
Abstract

studied some physical and chemical factors were in three stations selected from plant Hammdan . The results showed that the average values of the factors studied for pH (7.14, 7.31, 7.57) , total suspended solids TSS (304.04, 253.50, 203.04) mg/l, the values of the biological oxygen demand BOD5 (217.45, 175.41, 97.41) mg/l, the requirement of chemical oxygen demand COD (350.66, 272.50, 182.20) mg/l, sulfates (694.16 , 718.12 , 741.29) mg/l, chlorides (1571.00 , 1743.54 , 1941.87) mg/l, nitrates (13.69 , 17.57 , 21.09) mg/l, phosphate (5.92 , 4.97 , 4.26) mg/l, for three stations respectively . It is clear from these results that the treated water from this station does not conform with the standards of water that can throw it into water bodies .

درست بعض العوامل الفيزيائية والكيميائية في محطة معالجة میاه الصرف الصحي في حمدان - البصرة وبواقع ثلاثة محطات مختارة وأظهرت النتائج إن متوسط قيم العوامل المدروسة لدرجة الأس الهيدروجيني pH (7.14, 7.31 , 7.57) والمواد الصلبة العالقة الكلية TSS (304.04 , 253.50 , 203.04 ) ملغم/لتر, وقيم المتطلب الحيوي للأوكسجين BOD (217.45 , 175.41 , 97.41) ملغم/لتر, والمتطلب الكيميائي للأوكسجين COD (350.66 , 272.50 , 182.20) ملغم/لتر, والكبريتات (694.16 , 718.12 , 741.29) ملغم/لتر, والكلوريدات (1571.00 , 1743.54 , 1941.87) ملغم/لتر, والنترات (13.69 , 17.57 ,21.09) ملغم/لتر, والفوسفات (5.92 ,4.97 ,4.26) ملغم/لتر للمحطات الثلاثة على التوالي . ويتضح من ذلك إن المياه المعالجة من هذه المحطة لا تتطابق مع معايير المياه التي يمكن تصريفها الى المسطحات المائية .

Keywords

Wastewater --- p H --- TSS --- BOD5 --- COD --- SO4 --- NO3 --- PO4. --- مياه الصرف الصحي Wastewater --- pH --- TSS --- BOD --- COD --- SO4 --- Cl --- NO3 --- PO4 .


Article
Using ANN to model the biological removal of nitrogen compounds from al-Musayyib’s domestic wastewater using an SBR system

Authors: Nesrin J. AL-Mansori --- Ethar Aqeel Muslim
Journal: Mesopotamia Environmental Journal بيئة وادي الرافدين ISSN: 24102598 Year: 2018 Volume: 4 Issue: 3 Pages: 42-54
Publisher: Babylon University جامعة بابل

Loading...
Loading...
Abstract

The process of the biological removal of nitrogen compounds from wastewater that carried out in two stages and includes both nitrification and de-nitrification. Nitrification carried out under aerobic conditions using nitrosamines, which convert ammonia to nitrite. This unstable compound quickly converted to nitrate by nitrobacterium bacteria. This paper details the treatment of real domestic waste water from Al-Musayyib city, Babylon by conducting a laboratory scale batch reactor with different input samples and a variety of cycle times (6, 7, 7.5, 10 and 15 hours). The exploratory outcomes investigated for the detailing of a bolster forward, back-engendering, fake neural system (ANN) to foresee the proficiency of the consolidated expulsion of NO3, and NH3. ANN displaying did utilizing MATLAB's neural system tool compartment and SPSS programming. The removal efficiency of Nitrate (NO3-N) increased when the anaerobic time (AN) of cycles increased, while the removal efficiency of Ammonia (NH3-N) increased when the aerobic time (A) of cycles increased. Removal rates were between 88 and 97.5% for Nitrate (NO3-N), 12.8 and 87.3 % for Ammonia (NH3-N). As per the outcomes, this sort of treatment can utilized to expel nitrogen mixes from local wastewater and for different circumstances where the release is moderately low or temperamental.


Article
Effect of Some Plant Extracts Inhibitory Nitrification in The Mineralization of Nitrogen in The Soil Treatment of Various Organic Residues
تأثير بعض المستخلصات النباتية المثبطة لعملية النترجة في تعدن النتروجين في تربة معاملة بمخلفات عضوية مختلفة

Authors: Abdul Mehdi S. Al-Ansari عبدالمهدي صالح الانصاري --- Muayad I. Ali مؤيد ابراهيم علي
Journal: Basrah Journal of Agricultural Sciences مجلة البصرة للعلوم الزراعية ISSN: 18175868 Year: 2016 Volume: 29 Issue: 2 Pages: 475-484
Publisher: Basrah University جامعة البصرة

Loading...
Loading...
Abstract

An experiment was conducted in Laboratories of the College of Agriculture, University of Basrah to reveal of plants aqueous extracts of Caper seeds, Pomegranate peels , Date palm fiber and Blady grass rhizomes and chemical nitrification inhibitor Dicyandiamide (DCD) on nitrogen mineralization in soil treated with organic residues of poultry manure, cow manure, alfalfa Residue and corn cubs. Aqueous extracts were prepared at ratio of 1:10 ( plant material : water) and added to soil treated with 5% organic residue at concentration of 0.25 ml g-1soil. Soils were incubated at 30 °C for 15,30,45,60 and 75 days . After each incubation period set of samples were withdraw and NH4+, NO3¯ were determined. Results of the study showed that application of water extracts of Caper seeds increased NH4+-N but decreased NO3¯-N in soil treated with residues of poultry, cow and alfalfa compared with other extracts . However , at soils amendment with corn cubs residue highest NH4+-N concentration was obtained at DCD . Effect of Blady grass rhizomes and Date palm fiber extracts on N-mineralization differ according to organic residues source. Treated with Blady grass rhizomes decreased NH4+-N but increased NO3¯-N concentration at all extracts used . Results also showed that highest NH4+-N and NO3¯-N were associated with poultry manure and lower NH4+-N and NO3¯-N concentration were found in treatment of corn cubs. Increasing incubation time significantly increased NO3¯-N concentration but decreased NH4+-N concentration in soil at all treatments.

أجريت دراسة في مختبرات قسم علوم التربة والموارد المائية، كلية الزراعة، جامعة البصرة لبيان تأثير المستخلصات المائية النباتية لبذور الكبر وقشور الرمان وليف النخيل ورايزومات الحلفا المثبطة لعملية النترجة والمثبط الكيميائي DCD ((Dicyandiamide, في تعدن النتروجين في تربة ذات نسجة مزيجة رملية معاملة 5% مخلفات عضوية (مخلفات الدواجن والابقار والجت المطحون وكوالح الذرة الصفراء المجروشة). وقد حضر المستخلص المائي بنسبة 1:10 (مادة نباتية: ماء) واضيف الى التربة بمستوى 0.25 مل غم-1تربة. وحضنت المعاملات على درجة حرارة 35 م° لمدة 15و 30و45 و60 و75 يوماً , وقدرت كمية الامونيوم والنترات (NH4+-N ) و (NO3--N) المنطلقة بعد كل مدة حضن. وقد أظهرت النتائج ان معاملة التربة بالمستخلصات النباتية والمثبط DCD ادت الى اختلاف معنوي (P<0.01) في كمية الامونيوم والنترات في التربة حسب نوع المستخلص النباتي والمخلف العضوي فقد اعطى مستخلص بذور الكبر اعلى معدل لكمية الامونيوم وأقل معدل للنترات المتحررة مقارنة بجميع المستخلصات النباتية والمثبط DCD عند معاملة مخلفات الدواجن والابقار والجت المطحون وتفوق المثبط DCD بزيادة معدل كمية الامونيوم واقل معدل للنترات المتحررة لمعاملة كوالح الذرة مقارنة بجميع المستخلصات النباتية, وقد اختلف تأثير مستخلص قشور الرمان وليف النخيل باختلاف نوع المخلف العضوي فقد حقق مستخلص ليف النخيل زيادة معدل كمية الامونيوم وخفض معدل النترات المتحررة عند معاملة المخلفات الحيوانية (دواجن وابقار) في حين مستخلص قشور الرمان تفوق عند المخلفات النباتية (جت مطحون وكوالح الذرة). ومعاملة التربة بمستخلص رايزومات الحلفا ادت الى خفض معدل كمية الامونيوم وزيادة للنترات في التربة مقارنة بجميع المستخلصات النباتية . وقد اظهرت النتائج أن معاملة مخلفات الدواجن اعطت اعلى معدل لتعدن النتروجين(الامونيوم والنترات) بعدها جاءت معاملة الجت المطحون ثم مخلفات الابقار اما كوالح الذرة اعطت ادنى المعدلات. وزيادة مدة الحضن ادت الى خفض معدل كمية الامونيوم وزيادة معدل النترات المتحررة من المخلفات العضوية المضافة الى التربة.


Article
Treatment the Disinfected Diary water by using two type of Algae Chlorella, Lyngebia
معالجة مياه فضلات معمل الالبان المعقمة باستخدام نوعين من الطحالب Chlorella, Lyngebia

Loading...
Loading...
Abstract

The study used two types of algae to reduce contaminants in dairy wastewater, using Lyngebia and Chlorella. COD, PO4, NO3 and algal growth measured, at 22 ° C and 32 ° C,. The results of the study showed that the highest removal rates for Lyngebia (62%, 83%, 74% and 95% at 22 ° C) while for Chlorella (71% and 71% at 32 ° C, 88% and 95% at 22 ° C) (95%, 98%, 99% 95% at 22 ° C) respectively, and Chlorella (95%, 95% and 98% at 32 ° C),. (96% at 32 ° C, 99%, 97% and 95% at 22 ° C), and Chlorella (99% at 22 ° C at 97 ° C) (32 ° C and 97% 97% at 22 ° C),. In the optical density test, there was an increase in the optical density of both algae halves during the experiment.

استخدمت الدراسة نوعين من الطحالب لخفض الملوثات في مياه فضلات معمل البان كركوك حيث استخدم طحلب Lyngebia وطحلب Chlorella. وتم قياس كلا من COD، PO4 ،NO3 بالإضافة الى فحص نمو الطحالب. كما تمت الدراسة في درجتي حرارة وهي 22م° و32 م°. وقد أظهرت النتائج لفحص CODان اعلى نسب إزالة Lyngebia (62% و83% و74% و95% في 22م°) على التوالي Chlorella ( 71% و 71% في 32 و 88% و 95% في 22م°) على التوالي وفحص الفوسفات PO4 كانت اعلى نسب إزالة Lyngebia ( 95% و 98% و 99% 95% في 22م°) على التوالي Chlorella ( 95% و95% و 98% في 32م° و95% في 22م°) على التوالي وفحص النترات NO3 فقد أظهرت ان اعلى نسبة إزالة كانت Lyngebia ( 96% في 32م° و 99% و 97% و95% في 22م°) على التوالي Chlorella ( 99% في22م 97% في 32م° و 97% 97% في 22م°) على التوالي اما في فحص الكثافة الضوئية فقد لوحظ تزايد في الكثافة الضوئية لكلا الطحلبين خلال التجربة.


Article
Performance Evaluation of Al-Khadraa' Wastewater Treatment Plant, Mosul-Iraq
تقييم أداء محطة الخضراء لمعالجة مياه الصرف الصحي، الموصل- العراق

Authors: Ayad Fadeel Qasim1 أياد فضيل قاسم1 --- Omer Moayad Khalil Al-Obady2 عمر مؤيد خليل العبادي2
Journal: Tikrit Journal of Pure Science مجلة تكريت للعلوم الصرفة ISSN: 18131662 Year: 2018 Volume: 23 Issue: 7 Pages: 42-46
Publisher: Tikrit University جامعة تكريت

Loading...
Loading...
Abstract

The study aims to evaluate the operational efficiency of Al-Khadraa' wastewater treatment plant and the compatibility of the quality of treated water with the Iraqi standards for disposal into rivers and valleys. The study showed that there are large variations in the quantities and quality of the influent to the plant which sometimes lead to stop operational units of the plant and this has an adverse effect upon the plant function. The results showed that the strength of the influent is classified as weak to medium. The average BOD5/COD ratio is equals to 0.6. Also it seemed that the efficiency of the treatment was weak and the quality of the effluent is out of the Iraqi standards for disposal into rivers and valleys. The percentage removal of BOD, COD, TSS, PO4, NH3 were 83.15%, 79%, 69.7%,56.15%,41.88% respectively. The sequence of removal efficiency was in the order of: NH3 تهدف هذه الدراسة إلى تقييم الكفاءة التشغيلية لمحطة معالجة الخضراء ومدى توافق نوعية المياه المعالجة مع المحددات العراقية للطرح في الأنهار والمجاري المائية. تبين من خلال الدراسة أن هنالك تغاير كبير في كميات ونوعية المياه الداخلة إلى المحطة ما يؤدي ذلك إلى إيقاف تشغيل المحطة في بعض الاحيان وانعكاس ذلك سلبا على أداء المعالجة في المحطة. بينت النتائج أن شدة تركيز المياه الداخلة الى المحطة يمكن تصنيفها متوسطة- ضعيفة وان نسبة BOD5/COD تساوي 0.6 , كما أظهرت النتائج أن كفاءة المعالجة في المحطة ضعيفة وأن نوعية المياه المعالجة لا تتطابق مع المحددات العراقية للطرح في الأنهار والمجاري المائية إذ بلغت نسب الإزالة لكل من BOD، COD ،TSS ، PO4، NH3 (83.15%، 79% و69.7%، 56.15%، 41.88%)على التوالي وكفاءة الإزالة كانت على الترتيب NH3


Article
Effect of Dopant Concentration on the Structural, Optical and Sensing Properties of (SnO2)1-x(TiO2:CuO)x Sprayed Films
تأثير تركيز التشويب على الخواص التركيبية والبصرية والتحسسيه للأغشية SnO2) 1-x (TiO2: CuO) x) الرقيقه

Authors: Sara S. Mahmood ساره صادق محمود --- Bushra A. Hasan بشرى عباس حسن
Journal: Baghdad Science Journal مجلة بغداد للعلوم ISSN: 20788665 24117986 Year: 2019 Volume: 16 Issue: 2 Pages: 361-369
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Spray pyrolysis technique was subjected to synthesized (SnO2)1-x (TiO2: CuO) x Thin films on different substrates like glass and single crystal silicon using. The structure of the deposited films was studied using x-ray diffraction. A more pronounced diffraction peaks of SnO2 while no peaks of (CuO , TiO2 ) phase appear in the X-ray profiles by increasing of the content of (TiO2 , CuO) in the sprayed films. Mixing concentration (TiO2 , CuO) influences on the size of the crystallites of the SnO2 films ,the size of crystallites of the spray paralyzed oxide films change in regular manner by increasing of (TiO2 , CuO) amount. The effect of mixing concentration on the optical properties of the films was also investigated. The reflectance and transmittance spectra in the wavelength range (300-1100) nm were employed to determine the optical properties such as energy band gap (Eg) and refractive index (n), extinction coefficient (k) , real and imaginary parts of dielectric constants (ε1, ε2) for (SnO2)1-x(TiO2:CuO)x films. The energy band gap omit of which showed reduction from (3.65 to 2.2) eV by reducing of SnO2 amount from (100 to 70) % .The reduction of energy band gap was ascribed to the new tail states introduced in the band gap of tin oxide. The sensitivity of the prepared sensor film was determined resistance difference of the films when exposed to oxidizing gas. The data declared that the mixed SnO2 films have better sensitivity in comparison with unmixed films.

تم تصنيع اغشية رقيقة من (SnO2) 1-x (TiO2: CuO) x )على ركائز مختلفة مثل الزجاج والسيليكون احادي التبلور باستخدام تقنية االرش الكيميائي الحراري. تم فحص تركيب الاغشيه المرسبه باستخدام حيود الأشعة السينية. في مخطط السينية تظهر قمم حيود SnO2 اكثر وضوحا في حين لا تظهر قمم CuO و TiO2 ويتحسن التركيب عند زيادة محتوى TiO2: CuO في اغشيه الرش. تركيز التشويب لاغشيه TiO2: CuO يؤثر على حجم تبلور اغشيه SnO2 حيث يتغير حجم تبلور اغشيه الرش الحراري بصوره منتظمة بزيادة كمية TiO2: CuO. كما تم دراسة تأثيرتركيز التشويب على الخواص البصرية للأغشية. تم استخدام طيف الانعكاس والنفاذيه لاغشيه SnO2) 1-x (TiO2: CuO) x) في مدى الطول الموجي nm (300-1100) لتحديد الخواص البصرية مثل فجوة حزمه الطاقة (Eg) ومعامل الانكسار (n) ومعامل الخمود (k) والقيم الحقيقية والتخيلية لثوابت العزل الكهربائي ε1، ε2. لوحظ ان فجوة حزمه الطاقة تقل من 3.8 فولت إلى 2.65 فولت من خلال تقليل كمية TiO2: CuO. ويعزى انخفاض فجوة نطاق الطاقة وبالتالي زيادة طاقة أورباخ إلى الحالات الذيليه للشوائب على حزمه التوصيل أو حزمه التكافؤ لاوكسيد القصدير. يمكن حساب قيمة تحسسيه الغشاء عند تغيير مقاومة الغشاء عند التعرض لغاز اوكسيد النيتروجين. تظهر النتائج أن اغشيه SnO2 المشوبه لديها حساسية أفضل عند مقارنتها بالأغشية غير المشوبه.


Article
Assessment Efficiency Evaluation of Al-Diwaniya Sewage Treatment Plant in Iraq
تقييم كفاءة الاداء لمحطة معالجة مياه الصرف الصحي في الديوانية، العراق

Authors: Awatif Soaded Alsaqqar عواطف سؤدد عبدالحميد --- Basim Hussein Khudair باسم حسين خضير --- Ahmid Mekki احمد مكي جبار
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2014 Volume: 20 Issue: 2 Pages: 20-32
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

This study aims to evaluate the performance of the sewage treatment plant in Al-Diwaniya, one of cities in the southern part in Iraq. This evaluation could be used to facilitate effluent quality assessment or optimal process control of the plant. The influent reaching the plant is considered a medium to strong in strength with BOD5/COD ratio in the range 0.23 and 0.69 which can be considered an easily degradable sewage by the biological processes performed by the activated sludge unit. The quality of the effluent was found to be higher than the Iraqi standards for disposal to water bodies. The BOD5/COD ratios of the treated sewage varied over a wide range as low of 0.13 to 1.48 indicating operational problems in the plant. Regression analysis was performed to estimate the removal percentages of BOD5, COD, TSS and NO3 that the plant should perform by to reach the disposal limitations.

تهدف هذه الدراسة الى تقييم كفاءة الاداء لمحطة معالجة مياه الصرف الصحي في مدينة الديوانية احدى المدن في جنوب العراق . ويمكن من خلال هذه الدراسة تقييم وتخمين صفات المياه المطروحة او السيطرة المثلى في تشغيل المحطة . و تتغاير مياه الفضلات الداخلة الى المحطة من متوسطة الى عالية القوة وبنسبة طلب الاوكسجين الحيوي الى طلب الاوكسجين الكيمياوي 0,23 و 0,69 والتي تصنف هذه المياه بسهولة التحلل بواسطة الطرق البايولوجية (طريقة الحماة النشطة) . اما االمياه المعالجة من هذه المحطة فقد وجدت بانها لا تتطابق مع معايير المياه التي يمكن رميها الى المسطحات المائية، وان نسبة طلب الاوكسجين الحيوي الى طلب الاوكسجين الكيمياوي للمياه المطروحة من هذه المحطة تراوحت من 0,13 الى 1,48 والتي تؤشر الى وجود مشاكل تشغيلية في المحطة. وقد اجريت تحاليل احصائية لتخمين نسب الازالة للطلب الاوكسجين الحيوي، والاوكسجين الكيميائي و المواد العالقة والنترات بحيث يتم تشغيل المحطة بموجبها للوصول الى المعايير اللازمة لرمي المياه المعالجة الى المصادر المائية.

Listing 1 - 8 of 8
Sort by
Narrow your search

Resource type

article (8)


Language

English (5)

Arabic (3)


Year
From To Submit

2019 (1)

2018 (2)

2017 (1)

2016 (2)

2014 (2)