A Comparative Study of Power System Transient Stability Parameters Calculation
دراسة مقارنة لحساب معلم الأستقرارية العابرة لمنظومة القدرة

Authors: MAJLI NEMA HAWAS مجلي نعمة حواس --- FADIL MUHAMMED KALAF فاضل محمد خلف --- ARWA AMER ABDUL-KAREEM أروى عامر عبد الكريم
Journal: Al-Ma'mon College Journal مجلة كلية المامون ISSN: 19924453 Year: 2010 Issue: 16 Pages: 269-290
Publisher: AlMamon University College كلية المامون الجامعة

Loading...
Loading...
Abstract

The power system transient stability studies depend on the state of sudden disturbance to which the system is subjected, such as the fault state on the system. The increasing size of modren power systems requires fast and more efficient methods of solutions. Therefore the classical approach of repeated integrations will be length and time consuming. Investigations to overcome this difficulty led to the use of direct methods. These mothods use the energy balance in the system. Two different direct methods are investigated in this work to provide a comparative study with the Indirect Integration method. The first is the rate of change of kinetic energy method. The critical fault clearance time in this method corresponds to the machine. In which the RACKE has the largest negative value at this time. The second direct method is the extended equal area criterion. In this method the multi-machine system is composed of two subsets: one consists of the critical machines; the other comprises the remaining system. Each group is reduced to a single machine, and then the two-machine equivalents were reduced to a single machine to infinite bus system. Then the equal area criterion is applied to determine the Critical Clearing Time and Transient Stability Margin (TSM). As a result, the RACKE method has closer Critical Clearing Time and Transient Stability Margin to the Indirect Integration method although the EEAC method is faster than the RACKE method. The application of these methods on four; five and twelve machine power systems is presented. The programs that were used in this work are implemented by using (MATLAB).

تتركز دراسة الاستقرارية العابرة في منظومات القدرة الكهربائية على حالات الاضطراب المفاجئ التي تتعرض لها المنظومة على سبيل المثال حالات العطل التي تحدث في المنظومة. تم اعتماد الطرق غير المباشرة والطرق المباشرة لحساب زمن الإزالة الحرج للمنظومات في الطرق غير المباشر (الخطوة - خطوة) , تتضمن تكرار تكامل المعادلات التفاضلية للمنظومة على طول الزمن اللازم لحالة المنظومة خلال العطل وبعده , ويعاد هذا الحل لكل زمن إزالة عطل. ان هذه الطريقة وبالرغم من دقة نتائجها تستغر ق زمن حسابي كبير وهذا لا يتناسب مع تطور المنظومة الكهربائية. لذا فأن الدراسات المستمرة وجدت طرق سريعة وكفوءه لحساب الإزالة الحرج دون اللجوء الى الاعتماد على منحنيات المتغيرات المختلفة للمنظومة لتحديد زمن الازالة الحرج وهي الطرق المباشرة التي تتجاوز الصعوبات المذكورة اعلاه وان هذه الطرق تعتمد على معيار التوازن في الطاقة. تم اعتماد طريقتان في البحث لغرض مقارنتها مع الطريقة غير المباشرة. الطريقة الأولى هي طريقة معدل تغير الطاقة الحركية. الزمن الحرج لازالة العطل يكون طبقاً للماكنة ذات معدل تغير الطاقة الحركية الأكثر سالبيه. والطريقة الثانية هي طريقة تساوي المساحات المتوسعة ان هذه الطريقة تعتمد على تحويل المنظومة الى مجموعتين حيث تمثل المجموعة الاولى المكائن الحرجة والمجموعة الثانية تمثل باقي المكائن, وتحول المجموعتين الى ماكينتين مكافئتين ثم تحول إلى ماكنة مكافئة مربوطة الى القظيب إللامتناهي وتطبق بعد ذلك على المنظومة المبسطة طريقة تساوي المساحات المعروفة. تم التوصل في هذا البحث الى ان طريقة معدل تغير الطاقة الحركية تحقق قيم ادق من طريقة تساوي المساحات المتوسعة ووجد ان القيم التي توصلت لها طريقة معدل تغير الطاقة الحركية اقرب الى حد ما من القيم التي توصلت اليها الطريقة غير المباشرة على الرغم من ان طريقة تساوي المساحات المتوسعة تكون اسرع من طريقة معدل تغير الطاقة الحركية. ولقد تم اختيار ثلاثة منظومات تحققت من خلالها هذه النتائج وهي كما يلي :1-المنظومة الاولى ذات اربعة مكائن وستة عقد وسبعة خطوط . 2-المنظومة الثانية ذات خمسة مكائن واثناعشر عقده وخمسة عشر خط. 3-المنظومة الثالثة ذات اثنا عشرة ماكنة وتسعة عشر عقدة وثلاثة وثلاثون خط تم تنفيذ العمل باستخدام البرمجيات المتوفرة في المختبر الرياضي (MATLAB) وقورنت النتائج المستحصلة.


Article
Designing ANN for Load Flow in Electrical Power Systems Using EBP Algorithm
دراسة سريان الحمل في منظومة القدرة الكهربائية بإستخدام الشبكات العصبية الاصطناعية

Authors: Dhari Y, Al-Samaraee --- May R. Victor
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2005 Volume: 24 Issue: 10 Pages: 1352-1362
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

Keywords

Load Flow --- ANN --- Power System


Article
THE APPLICATION OF PROGRAMMING FAST METHOD FOR CALCULATION THE CRITICAL CLEARING TIME IN TRANSIENT STABILITY ANALYSIS OF IRAQ SUPER GRID
تطبيق طريقة برمجية سريعة لحساب وقت الازالة الحرج في تحليل الاستقرارية العابرة لشبكة الجهد الفائق العراقية

Authors: Majli Nema Hawas مجلي نعمة حواس --- Maitham Ali Naji ميثم علي ناجي --- Arwa Amer Abdul Kareem أروى عامر عبد الكريم
Journal: AL-TAQANI مجلة التقني ISSN: 1818653X Year: 2014 Volume: 27 Issue: 4 Pages: E1-E21
Publisher: Foundation of technical education هيئة التعليم التقني

Loading...
Loading...
Abstract

A transmission line trip during a power swing may cause instability of a power system. It is necessary to recognize the power swing from fault based on stability boundary, the power swing blocking relays must be set to do that, power swing should be analyzed, a way of probability of occurrence of fault must be found, the critical condition under which the stability of a power system hasn’t been disturbed is recognized & finally the settings of the power swing relays are calculated. The main aim of this paper is to reduce the execution time of the process of finding of the Critical Clearing Time (CCT) using Programming Fast Method (PFM) and compare it with Bisection Method. In practice however, calculating the CCT is computationally inefficient and not desirable because the Bisection method is a tedious and inefficient process. A proposed method for finding the CCT of the power system at any direct fault or indirect-fault is more efficient method in the accuracy & solution time to calculate (CCT) in transient stability analysis. The results obtain by Bisection and proposed methods show that the proposed method reduce the execution time of the CPU about 8-10 times.In this paper the CCT was calculated for two power systems (single machine and the Iraq Super Grid at 10 locations in the Iraqi transmission line network) by using Bisection & proposed methods.MATLAB version 7 is used to implement several programs for the optimal execution time of the CPU time, with using PC4 and CPU speed 3 GHz.

في نظام القدرة الكهربائية اي قطع او عطل في منظومة القدرة خلال تارجح الماكنة قد يسبب حالة عدم استقرار في نظام القدرة لذلك يكون من الضروري تمييز نظام القدرة خلال حدوث العطل ويتم ذلك عن طريق اجهزة حماية هذه الانظمة لايجاد طريقة افتراضية لحدوث العطل وتحديد الظروف الحرجة لأستقرارية منظومة القدرة وحسابات تارجح النظام.ان الهدف الرئيسي من هذا البحث هو تقليل زمن الانجاز الازم لايجاد زمن الازالة الحرج في وحدة المعالجة المركزية بواسطة طريقة البرمجة السريعة ومقارنتها بطريقة التنصيف. عمليا ,تكون طريقة التنصيف غير مرغوب فيها وتكون غير فعالة وشاقة جدا اما الطريقة المقترحة في عملية ايجاد زمن الازالة الحرج عند اي عطل مباشر او غير مباشر فوجد انها اكثر فاعلية من ناحية الدقة وزمن الحل لتقييم استقرارية القدرة.تشير النتائج المستحصلة بالطريقتين الى تفوق الطريقة المقترحة على طريقة تنصيف الزمن. حيث وجد انها تقلل زمن الانجاز في وحدة المعالجة المركزية بمقدار يتراوح بين 8 – 10 مرات. في هذا البحث تم حساب زمن الازالة الحرج لمنظومتين اختباريتين (الماكنة الاحادية و10 موقع لشبكة الجهد الفائق العراقية) بواسطة تطبيق طريقة التنصيف والطريقة المقترحة وذلك باستخدام برنامج الماتلاب (اصدار 7) وحاسبة بانتيوم 4 وسرعة المعالج 3 ميغا هيرتز.


Article
ANN Based Detection and Location of Severe Three Phase Trip on the Transmission Lines of an Uncontrolled Power System
استعمال دوائر الشبكات العصبية الاصطناعية في اكتشاف وتحديد موقع دائرة قصر شديدة (ثلاثية الأطوار) على خطوط نقل الطاقة لنظام قدرة غير مسيطر عليه

Authors: Suhail Muhammad Ali سهيل محمد علي --- Muntaser Abdulwahid Salman منتصر عبد الواحد سلمان
Journal: Anbar Journal of Engineering Sciences مجلة الأنبار للعلوم الهندسية ISSN: 19979428 Year: 2009 Volume: 2 Issue: 1 Pages: 36-48
Publisher: University of Anbar جامعة الانبار

Loading...
Loading...
Abstract

Severe three phase trips are simulated on four arbitrary locations of an uncontrolled power system transmission lines. The responses of three measurable state variables of the system (rotor speed, stator direct axis current, and stator quadrature - axis current) are recorded, and suitable ANNs are trained to detect and locate the positions of the corresponding trips. The paper proves that this method is quick, active and accurate to diagnose and find the locations of that kind of trips.

تم تمثيل أعطال دائرة القصر الشديدة على أربعة مواقع عشوائية من خط نقل الطاقة العائد إلى نظام قدرة غير خاضع للسيطرة . تم تسجيل استجابات ثلاثة متغيرات قابلة للقياس من متغيرات نظام القدرة (سرعة الجزء الدوار ومركبتي تيار الجزء الثابت المتعامدتان)، ثم دربت دوائر شبكات عصبية مناسبة لاكتشاف حدوث تلك الأعطال وتحديد أمكنتها. لقد برهن البحث أن هذه الطريقة هي سريعة وفعالة ودقيقة لتشخيص تلك الأعطال ومعرفة أماكنها


Article
The protecting State System in International Humanitarian Law
نظــــام الدولة الحاميــــة في القانون الدولي الإنساني

Loading...
Loading...
Abstract

Once the occurrence of international armed conflict does not stop diplomatic relations between the warring countries, but begin human suffering for failure to those wars of casualties and falling numbers of prisoners under the authority of the mercy of the enemy, and despite having a lot of international legal norms to protect those victims but legal problem was - and still are - the problem of the application of these rules and ensure respect for international and commitment, as well as the international center for free watchful Authority's efforts to achieve this end. So assured of international humanitarian law in armed conflicts all international need to establish (System Protecting Power) to enable the parties to the conflict to continue the dialogue, as is similar to the system to some extent the state system representing the interests of a particular country when interruption diplomatic relations, another angle that system is legal means to ensure effective implementation of the provisions of international humanitarian law, particularly with regard to the protection of victims of international armed conflicts, also fired on those neutral Power which accepted protect the interests of the state warring with the other party (b Protecting Power), which enjoys the rights and duties guaranteed her rules of international humanitarian law to become a tool effective positive operate through the provision of services and humanitarian aid during an international armed conflict is working to accomplish the role assigned to maintain the warring interests of the state and the citizens and officially neutral. And to familiarize themselves with all aspects of the subject has divided our research into two sections main, first section deals with what the state system, the Protecting The second section deals with the mechanism of application of the Protecting Power, then mention the most important conclusion of our findings in our research.

بمجرد وقوع نزاع مسلح دولي لا تتوقف العلاقات الدبلوماسية بين الدول المتحاربة فحسب بل تبدأ معاناة إنسانية لما تخلفه تلك الحروب من سقوط ضحايا ووقوع أعداد من الأسرى تحت سلطة ورحمة العدو ، وعلى الرغم من وجود الكثير من القواعد القانونية الدولية لحماية أولئك الضحايا إلا أن المشكلة القانونية كانت - وما زالت- مشكلة تطبيق هذه القواعد الدولية وضمان احترامها والالتزام بها، فضلاً عن خلو الوسط الدولي عن السلطة الساهرة الرامية لتحقيق هذه الغاية.
لذا أكد القانون الدولي الإنساني في النزاعات المسلحة الدولية كافة على ضرورة إنشاء ( نظام الدولة الحامية ) لتمكين طرفي النزاع من مواصلة الحوار، إذ يشبه هذا النظام إلى حد ما نظام الدولة الممثلة لمصالح بلد معين عند انقطاع العلاقات الدبلوماسية ، ومن زاوية أخرى فإن هذا النظام يعد وسيلة قانونية فعالة لضمان تنفيذ أحكام القانون الدولي الإنساني ولاسيما فيما يتعلق بحماية ضحايا النزاعات المسلحة الدولية ، كما أطلق على تلك الدولة المحايدة التي قبلت حماية مصالح الدولة المتحاربة لدى الطرف الآخر بـ(الدولة الحامية) والتي تتمتع بحقوق وواجبات كفلتها لها قواعد القانون الدولي الإنساني لتصبح أداة فعالة ايجابية تمارس نشاطها من خلال تقديم خدمات ومساعدات إنسانية إبان النزاعات المسلحة الدولية تعمل على انجاز الدور المناط بالحفاظ على مصالح الدولة المتحاربة وعلى رعاياها بشكل رسمي وحيادي .
ومن أجل الإلمام بجميع جوانب الموضوع فقد قسمنا بحثنا هذا إلى مبحثين أساسيين ، يتطرق المبحث الأول إلى ماهية نظام الدولة الحامية ، أما المبحث الثاني فيتناول آلية تطبيق نظام الدولة الحامية ، ثم نذكر في الخاتمة أهم النتائج التي توصلنا إليها في بحثنا هذا .


Article
Damping of Power Systems Oscillations by using Genetic Algorithm-Based Optimal Controller

Author: Akram F. Bati
Journal: Iraqi Journal for Electrical And Electronic Engineering المجلة العراقية للهندسة الكهربائية والالكترونية ISSN: 18145892 Year: 2010 Volume: 6 Issue: 1 Pages: 50-55
Publisher: Basrah University جامعة البصرة

Loading...
Loading...
Abstract

In this paper, the power system stabilizer (PSS) andThyristor controlled phase shifter(TCPS) interaction is investigated .The objective of this work is to study and design a controllercapable of doing the task of damping in less economical controleffort, and to globally link all controllers of national network in anoptimal manner , toward smarter grids . This can be well done if aspecific coordination between PSS and FACTS devices , isaccomplished . Firstly, A genetic algorithm-based controller isused. Genetic Algorithm (GA) is utilized to search for optimumcontroller parameter settings that optimize a given eigenvalue basedobjective function.Secondly, an optimal pole shifting, based on moderncontrol theory for multi-input multi-output systems, is used. Itrequires solving first order or second order linear matrix Lyapunovequation for shifting dominant poles to much better location thatguaranteed less overshoot and less settling time of systemtransient response following a disturbance.


Article
The Effect of Power System Stabilizers (PSS) on Synchronous Generator Damping and Synchronizing Torques
تأثير مثبت منظومة القدرة على عزم التخميد وعزم التزامن للمولد المتزامن

Author: Fadhil M. Kalaf فاضل محسن خلف
Journal: AL-MANSOUR JOURNAL مجلة المنصور ISSN: 18196489 Year: 2012 Issue: 18 Pages: 101-118
Publisher: Private Mansour college كلية المنصور الاهلية

Loading...
Loading...
Abstract

The synchronizing and damping torque coefficients in the range of theelectromechanical oscillation frequencies provide a measure of thegenerators' contribution towards power system stability under smalldeviations, and may be taken as stability indices even for multi machinesystems, although their interpretation is rather complex in this case. Thispaper presents the effect of Power System Stabilizer (PSS) on thesynchronizing and damping torque coefficients for a synchronous generatorconnected to an infinite busbar through impedance; it explicitly includes theeffects of its Automatic Voltage Regulator (AVR) and of the additionalstabilizer signal derived from the rotor speed. .Results obtained were compared with the conventional (AVR) usingMATLAB 7 programming language.

أن معاملاتِ عزوم المزامنة والتخمید في مدى تردداتِ تذبذبِ خاصیةالكھرومیكانیك یُعطیانِ مقیاس لمساھمةِ المولّداتَ المتزامنة في إستقرارِیة المنظومةِالكھربائیِة في حالة الإنحرافاتِ الصغیرةِ، وقَدْ یُؤْخَذانِ كفھارس إستقرارِ حتى لأنظمةِالماكناتِ المتعددةِ، بالرغم من تعقید الموضوع في ھذه الحالةِ. یُقدّمُ ھذا البحث تأثیرَ مثبّتِعلى معاملاتِ عزوم المزامنة والتخمید لمولّد متزامن أوصلَ (PSS) النظامِ الكھربائيِإلى قضیب لانھائي خلال معاوقة كھربائیةِ. ومن ضمّنُ التأثیراتَ تأثیر منظّمِ الفولطیةوتأثیر إشارةِ المثبّتِ الإضافیةِ المأخوذة مِنْ سرعةِ الدوّار . (AVR) الآليِ(AVR) أن النَتائِج المكتسبة قُورنتْ بإستعمال منظّمِ الفولطیةِ الآليِ التقلیديِ.MATLAB وبأستخدام الُلغةَ البرمجیة


Article
Fuzzy Neural Design of Power Systems Stabilizers
التصميم العصبي المضببّ لمثبتات أنظمة القدرة

Author: Ibrahim F Jasim
Journal: journal of kerbala university مجلة جامعة كربلاء ISSN: 18130410 Year: 2010 Volume: 8 Issue: 1 Pages: 333-345
Publisher: Kerbala University جامعة كربلاء

Loading...
Loading...
Abstract

This paper presents a new approach of designing the Power Systems Stabilizer (PSS) that is based on fuzzy neural system. Adaptive Network based Fuzzy Inference System (ANFIS) is utilized in constructing the Fuzzy Neural Power Systems Stabilizer (FNPSS). The employment of ANFIS enables the system avoiding defects caused when using fuzzy logic and neural networks individually in designing an efficient PSS. Single Machine Infinite Bus (SMIB) power system has been taken as a case study to evaluate the suggested strategy performance. Simulation results have been conducted to confirm the approach validity.

يستعرض هذا البحث طريقة جديدة لتصميم مثبتات أنظمة القدرة (PSS) و التي تعتمد على أنظمة الأعصاب المضببّة. فقد تم أستخدام الدوائر المتكيفة و التي تعتمد على أنظمة الأستنتاج المضببّ (ANFIS) للحصول على مثبت أنظمة القدرة العصبية المضببّة. أن أستخدام (ANFIS) يمكّن النظام تجنب العيوب الناجمة عن أستخدام المنطق المضببّ و الشبكات العصبية بصورة منفردة في تصميم مثبت كفوء لأنظمة القدرة. و قد تم أخذ نظام القدرة ذو الماكنة المنفردة و الخط اللا متناهي كحالة دراسية لتقييم أداء الستراتيجية المقترحة. كما و قد تم الحصول على نتائج محاكاة لتأكيد فاعلية الطريقة.


Article
Comparison between Using FLC and Auto-Tuning FLC in Synchronous Generator Transient Voltage Stability Enhancement
مقارنة بين استخدام متحكم المنطق الضبابي وبين متحكم المنطق الضبابي تلقائي التنغيم لتحسين استقرارية الجهد العابر لمولد متزامن

Authors: Majli Nema Hawas --- Abdullah Yaseen Abbas
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2013 Volume: 31 Issue: 8 Part (A) Engineering Pages: 1474-1482
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

This paper compares between responses of Fuzzy Logic Controller (FLC) based exciter and auto-tuning FLC based exciter. Both of the exciters are simulated separately with synchronous generator connected to infinite bus through a short transmission line. The systems where subjected to three phase fault at the infinite bus, maximum Integral of Square Error (ISE) of generator terminal voltage response and critical clearing time were taken as performance indices of the exciters. The systems then studied under normal operating condition to justify the need of auto-tuning.

هذه الورقة تقارن بين أستجابة محفز معتمد على مسيطر ضبابي وإستجابة محفز معتمد على مسيطر ضبابي ذاتي التنغيم. تم محاكاة كل محفز على حده للسيطرة على الجهد الطرفي العابر للمولد تزامني متصل بعمومي لانهائي خلال خط نقل قصير. أخضع النظام الى إضطراب ثلاثي الطور على العمومي اللانهائي. أستخدم تكامل مربع الخطأ لاستجابة الفولتية الطرفية للمولد وزمن الإزالة الحرج كدلائل لمعرفة الإداء للمحفزات في ظروف العمل المضطربة وتم إثبات الحاجة الى التنغيم الذاتي في ظروف العمل الطبيعية.


Article
DESIGN OPTIMIZATION OF A HYBRID HYDRO-WIND MICROPOWER SYSTEM FOR RURAL COMMUNITIES

Authors: Amer Mejbel Ali --- Sameer Saadoon Algburi --- Mohammad Abdelmajed Aljaradin
Journal: Journal of Engineering and Sustainable Development مجلة الهندسة والتنمية المستدامة ISSN: 25200917 Year: 2018 Volume: 22 Issue: 2 (Part-5) Pages: 1-10
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

Renewable energies can play an important role to provide electricity to rural communities .This work study the optimum design of a hybrid hydro-wind , micro-power system in rural area . Six case studies, including the impact of hydro head, flow rate, efficiency, and head loss for micro hydropower with wind turbine hub height were implemented based on HOMER software. The simulation results show the importance of using HOMER to assist system designers for assigning the optimum design of hybrid system components