research centers


Search results: Found 4

Listing 1 - 4 of 4
Sort by

Article
OPTIMAL NETWORK RECONFIGURATION OF DISTRIBUTION SYSTEMS FOR IMPROVING THE PERFORMANCE IN TERM OF POWER QUALITY USING BAT ALGORITHM
إعادة تشكيل شبكات التوزيع الكهربائية لتحسين جودة أداء القدرة وبإستخدام خوارزمية محاكاة الوطواط

Author: Nesrallh Salman نصر الله سلمان
Journal: DIYALA JOURNAL OF ENGINEERING SCIENCES مجلة ديالى للعلوم الهندسية ISSN: 19998716/26166909 Year: 2015 Volume: 8 Issue: 4 Pages: 376-385
Publisher: Diyala University جامعة ديالى

Loading...
Loading...
Abstract

Power quality is considered as one of the most important issue in power distribution systems. Voltage sag is considered as one of the most common power quality problems. It may cause sensitive equipment to malfunction and process interruption. In this work a method of optimal network reconfiguration is proposed to mitigate voltage sag problem in power distribution networks. It is applied to a distribution network in a specified period (usually one year) to minimize the number of propagated voltage sags (Nsag) index. To find the optimal reconfigured network, Bat algorithm (BA) as optimization technique is used. To validate the proposed method, a practical distribution system (section of Malaysian grid) is used. The simulation results show that it is effective to apply the proposed technique in mitigating voltage sag problem in practical power distribution systems.

تعتبر جودة القدرة الكهربائية كأحد أهم القضايا في أنظمة توزيع الطاقة الكهربائية. ويعتبر الجهد المفاجئ باعتباره واحدا من الأكثر شيوعا في مشاكل جودة القدرة. فإنه قد يسبب للمعدات الحساسة سوء الأداء او التوقف عن العمل. في هذا البحث تم اقتراح طريقة الأمثلية في إعادة تشكيل شبكة التوزيع للتخفيف من تأثير مشكلة انخفاض الجهد المفاجئ في شبكات توزيع الطاقة. حيث يتم تقييم اداء شبكة توزيع في فترة محددة (عادة سنة واحدة) وتقييمها من خلال تقليل مؤشر عدد انتشار حالات انخفاض الجهد (Nsag). ومن أجل العثور على شبكة التوزيع الأمثل تكوينا تم استخدام خوارزمية محاكاة الوطواط والتي تعتبر من تقنيات الأمثلية لهذا الغرض. ومن اجل التحقق من صحة الطريقة المقترحة تم تطبيقها باستخدام شبكة توزيع عملية (جزء من الشبكة الماليزية) حيث تبين من نتائج المحاكاة ان هذه الطريقة المقترحة فعالة في تخفيف تأثير مشكلة انخفاض الجهد المفاجئ في منظومات التوزيع الكهربائية.


Article
Investigate and Analyze the Electromagnetic Field Levels Inside Electric Power Substation

Authors: Kamil Jadu Ali --- Ghanim Thiab Hasan --- Mahmood Ali Ahmed
Journal: Tikrit Journal of Engineering Sciences مجلة تكريت للعلوم الهندسية ISSN: 1813162X 23127589 Year: 2017 Volume: 24 Issue: 3 Pages: 12-17
Publisher: Tikrit University جامعة تكريت

Loading...
Loading...
Abstract

Electric power transformers are a very important part of modern electric power and transmission line network systems and they consider as a high level source of electromagnetic fields which can affect the health of workers in station. In this research, electric and magnetic fields caused due to the operation of power distribution substation of 132/33 kV are investigated in order to avoid the overexposure of these fields to workers. Research has been conducted on both the mathematical calculations and practical measurements. The intensities of electric and magnetic fields have been measured at substation by EMF tester device. Safe zones from some equipment have been determined. Comparison the obtained results with the standard safety guideline limits shows that they are within the acceptable limits.


Article
Analysis of a neutronic computational model for the core of material testing reactor MTR by using SQUID code
تحليل نموذج حسابي نيوتروني لقلب مفاعل اختبار المواد MTR باستخدام البرنامج SQUID

Author: Mohammed Haider Al-Taweel محمد حيدر الطويل
Journal: Journal of Kufa - physics مجلة الكوفة للفيزياء ISSN: 20775830 Year: 2015 Volume: 7 Issue: 1 English and Arabic Pages: 74-91
Publisher: University of Kufa جامعة الكوفة

Loading...
Loading...
Abstract

It is a conventional practice in the design of nuclear reactor to introduce calculation of hot points to determine spatial variation for energy generated and then determine power distribution .The study had been carried out for core of a reactor type (MTR) by the neutronic code SQUID. In this study, we replace the reflector of the reactor by instead of as originally the reactor designed .From the study we conclude that the reactor can operates safely ,to make sure of that we calculate the multiplication factor where their values ranged from (1.0854) when all control rods are up to (1.001)when three control rods are up . Also the values of hot points were calculated and compared with French documents results with as a reflector where the difference is (0.19%),and with light water as reflector instead of heavy water was calculated . For different cases according to control rod position , the values of hot point ranged between ( 0.46) to (1.64) in case all control rods are up also the values of the average power distributed on different fuel cells were calculated in case of light water as reflector firstly with three control rods are down and the maximum value .Secondly in case of four control rods are down, the maximum value we notice almost coincidence between the neutron flux distribution through the core of reactor and in different positions of control rods.

أن من المناسب عند تصميم أي مفاعل نووي الأخذ بحسابات النقاط الحارة لتحديد تغيرات الطاقة المتولدة ومن ثم تحديد توزيع القدرة , أجريت الدراسة لقلب مفاعل نوع باستخدام البرنامج النيوتروني , في هذه الدراسة تم استبدال العاكس للمفاعل النووي بالماء الخفيف بدلا من الماء الثقيل الذي هو مصمم لقلب المفاعل النووي أصلا حيث تم الاستنتاج بإمكانية عمل المفاعل النووي بصورة آمنة وذلك من خلال حساب عامل التكاثر النيوتروني الذي تتراوح قيمته بين في حالة أعمدة السيطرة جميعها مرفوعة إلى الأعلى و في حالة ثلاثة أعمدة سيطرة مرفوعة إلى الاعلى كذلك فان قيم النقاط الحارة قد حسبت بوجود الماء الثقيل كعاكس وقورنت مع النتائج المنشورة في الوثائق الفرنسية وكان الفرق بينهما , كذلك حسبت النقاط الحارة في حالة الماء الخفيف كعاكس ولعدة حالات حسب موضع أعمدة السيطرة وكانت القيم تتراوح بين إلى في حالة جميع أعمدة السيطرة مرفوعة إلى الاعلى كذلك فان قيم معدل القدرة موزعة على خلايا الوقود المختلفة قد حسبت في حالة وجود الماء الخفيف كعاكس أولا في حالة أعمدة السيطرة ثلاثة منها منزلة إلى الأسفل وكانت أعظم قيمة للقدرة في وثانيا في حالة أعمدة السيطرة أربعة منها منزلة إلى الأسفل فان أعظم قيمة لمعدل القدرة هو .كذلك يوجد تطابق متقارب بين توزيع الفيض النيوتروني خلال قلب


Article
Different Estimation Methods of the Stress-Strength Reliability Power Distribution

Authors: Bareq Baqe Selman --- Alaa M. Hamad
Journal: Ibn Al-Haitham Journal For Pure And Applied Science مجلة ابن الهيثم للعلوم الصرفة والتطبيقية ISSN: 16094042/25213407 Year: 2019 Volume: 32 Issue: 3 Pages: 70-82
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

This paper deals with estimation of the reliability system in the stress- strength model of the shape parameter for the power distribution. The proposed approach has been including different estimations methods such as Maximum likelihood method, Shrinkage estimation methods, least square method and Moment method. Comparisons process had been carried out between the various employed estimation methods with using the mean square error criteria via Matlab software package

Listing 1 - 4 of 4
Sort by
Narrow your search

Resource type

article (4)


Language

English (3)


Year
From To Submit

2019 (1)

2017 (1)

2015 (2)