research centers


Search results: Found 6

Listing 1 - 6 of 6
Sort by

Article
Evaluation of the effect of preheating on micro leakage of Class II composites Restoration (A comparative in vitro study)

Authors: Wasan M. Hasson --- Zainab M. AbdulAmeer
Journal: Journal of baghdad college of dentistry مجلة كلية طب الاسنان بغداد ISSN: 16800087 Year: 2017 Volume: 29 Issue: 2 Pages: 21-25
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Background: The aim of this in vitro study was to evaluate and compare the effect of preheating microleakage among three different filler size composites which include Filtektm Z250 micro hybrid, Z250xt Nano hybrid and nanocomposite Z350xt. in Class II cavity preparation .Materials and methods: sixty maxillary first premolars were prepared with class II cavities. Samples were divided into three groups according to material used group A (FiltekZ250 micro hybrid). Group B(Z250xt Nano hybrid). Group C (nanocomposite Z350xt)and each group divided into two subgroups of ten teeth according to temperature of composite: Group A1 Teeth are restored by composite at room temperature(24±1˚C), A2 Teeth are restored by same composite at preheated temperature(54±1˚C). After 24 hrs. immersion in 2% in methylene blue, samples were sectioned and micro leakage was estimated.Results: The greater scores of micro leakage mentioned in Group A( Z250 micro hybrid) in cervical margin while in Group B( Z250xt Nano hybrid) and Group C (Z350xt nanocomposite) have least score of micro leakage especially in occlusal margin.Conclusions: The scores of micro leakage for all groups varied with different material, margin and temperature. Generally, preheating decreased micro leakage in all groups of composites ,but Preheating decreased micro leakage effectively in Z250 micro hybrid more than Z250xt Nano hybrid and Z350xt nanocomposite micro leakage


Article
Numerical Analysis of the Effect of Weld – Joints Preheating on Temperature Distributions In GMAW
التحليلات العددية لتأثير التسخين الأولي لمنطقة الربط على التوزيع الحراري بعملية لحام القوس الكهربائي المعدني الغازي

Authors: Abbas Sh. Alwan --- Jalal M. Jalil --- Muna K. Abbass
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2014 Volume: 32 Issue: 2 Part (A) Engineering Pages: 325-338
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

In this research , medium carbon steel type (AISI 1045 ) sheets with 8 mm thickness were welded by Gas Metal Arc Welding Process (GMAW), this study included the application of numerical analyses by using control volume method (CVM) to obtain the effect of preheating process with different temperatures (75 ˚C , 125 ˚C and 225 ˚C ) on temperature distribution of the welded joint in addition to determination of cooling rates which were achieved for 3-D heat transfer in the weldment. Results showed the analyses contributed effectively to predict the temperatures distribution for the welded joint and get mathematical models for the cooling rates at welding variables ( welding speed was equal 2.5 mm / sec , and welding current was equal 180 Amp ) with different preheating temperatures.

في هذا البحث تم لحام صفائح من الفولاذ متوسط الكربون نوع ( (AISI1045 بطريقة لحام القوس الكهربائي المعدني الغازي (GMAW) لصفيحة ذات سمك 8 ملم . تضمنت هذه الدراسة تطبيق التحليلات العددية باستخدام طريقة الحجوم المحدود( CVM ) على تاثير عملية التسخين الاولي باختلاف درجات حرارية هي ( 75 مº, 125مº, 225مº ) على التوزيع الحراري لمنطقة الربط, فضلا عن تحديد معدلات التبريد لانتقال الحراره الثلاثي الابعاد في الملحومة. نتائج التحليلات العددية تيبن انها ساهمت بشكل فعال في التنبؤ عن التوزيع الحراري لمنطقة اللحام والحصول على نماذج رياضية لمعدلات التبريد عند متغيرات ظروف اللحام هي (سرعة لحام 2.5ملم/ثانية وتيار لحام 180 أمبير وعند مختلف درجات الحرارة للتسخين الاولي).


Article
Soil temperature profile and its readiness for controlling buildings indoors Temperature at Erbil city – Iraqi Kurdistan Region (IKR)
مقد درجة حرارة التربة وامكانية استخدامها للسيطرة على درجة الحرارة داخل الابنية فى مدينة اربيل اقليم كردستان العراق

Authors: Tariq H.Karim طارق حمه كريم --- Sirwan Ali Rasha سيروان علي ره شه
Journal: Sulaimania Journal for Engineering Sciences مجلة السليمانية للعلوم الهندسية ISSN: 24101699/24156655 Year: 2014 Volume: 1 Issue: 1 Pages: 29-41
Publisher: university of Sulaimania جامعة السليمانية

Loading...
Loading...
Abstract

Soil temperature varies both diurnally and seasonally and can determine the temperature gradient within the collector loops of the ground source heat pump. To study spatial and temporal variations of soil temperature besides investigating the possibility of using underground soil temperature of the region for the installation of ground heat exchange systems, the current study was conducted. Soil temperature was measured at two locations in Erbil city/ IKR during the period from November, 1st, 2012 to February, 28th, 2013 with temperature sensors inserted in the ground at different depths. . It has been observed that during January and February the soil temperature offered the highest and lowest fluctuations respectively and they were closely related to ambient air temperature. The results also indicated that soil temperature increased with increasing depth up to a depth of 3.5 m in most cases and thereafter started to decrease with increasing depth. Furthermore, it was shown that the reliability of soil temperature prediction from air temperature decreased with the increase in soil depth. Positive differences at a depth of 3.5 m February ranged from 13.73 to 21.56 oC during the winter season from December to. The results can be valuable in planning for preheating system during the cold seasons.

تخضع درجة حرارة التربة للتغيرات اليومية والموسميةوهى تحدد الانحدار الحرارى ضمن حلقات انظمة التدفئة. من اجل دراسة التباين الزمانى والحيزى لحرارة التربة فضلا عن امكانية استخدام حرارة باطن الارض لاغراض التدفئة قيست درجة حرارة التربة فى موقعين داخل مدينة اربيل/اقليم كردستان العراق ضمن الفترة المحصورة ما بين شهرى تشرين الثانى 2102 وشباط 2102 باستخدام مجسات حرارية منصوبة على اعماق مختلفة. لوحظ اعلى واقل تذبذب لحرارةالتربة خلال شهرى كانون الثانى وشباط على التوالى واستجاب التذبذب الحرارى الى تذبذب حرارة الهواء بصورة وثيقة. كما اشارت النتائج الى ازدياد حررارة التربرة مرع ازديرادالعمق الى حد 2.3 م وبعدها بدأت بالانخفاض، و عرلاوة علرى ذلك لوحظ بأن دقة التنبؤ بحرارة التربة من حرارة الهواء تقرل بأزدياد العمق. كما وان وجود فروقات معنويرة موجبرة برين حرارة التربة وحرارة الهواء فى المدى ما بين 02.32 و 20.32 م 1 عنررد العمررق 2.3 م خلال شهرى كانون الاول وكانون الثانى قد تساعد فى استخدام حرارة باطن الارض لاستخدام التدفئة خلال المواسم الباردة.


Article
Experimental Study Of Air Flow Rate Effects On Humidification Parameters With Preheating And Dehumidification Process Changing

Author: Ayad Tareq Mustafa
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2011 Volume: 17 Issue: 4 Pages: 979-992
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

This research study experimentally the effect of air flow rate on humidification process parameters. Experimental data are obtained from air conditioning study unit T110D. Results obtained from experimental test, calculations and psychometrics software are discussed. The effect of air flow rate on steam humidification process parameters as a part of air-conditioning processes can be explained according to obtained results. Results of the steam humidification processes (1,2) with and without preheating with 5A and 7.5A shows decreasing in dry bulb temperature, humidity ratio, and heat add to moist air with increasing air flow rate, but humidification load, and total energy of moist air increase with increasing air flow rate in the testing tunnel. The steam humidification process (1) with dehumidifying coil shows increase in dry bulb temperature, humidity ratio, humidification load, and heat add to moist air with increasing air flow rate in the testing tunnel, but the total energy decrease as air flow rate increase. These obtained results can be beneficial for controlling comfort air-conditioning processes in buildings.

هذا البحث يدرس تأثير نسبة جريان الهواء عمليا على معاملات عملية الترطيب. البيانات التجريبية تم الحصول عليها من جهاز وحدة دراسة تكييف الهواء T110D. تم مناقشة نتائج الحسابات والبرنامج الحسابي المصردي. تأثير نسبة جريان الهواء على معاملات عملية الترطيب بالبخار يمكن توضيحها في النتائج المستحصلة كجزء من عمليات تكييف الهواء. نتائج الترطيب بالبخار (2,1) مع/ بدون تسخين ابتدائي 5A و7.5A اظهرت نقصان في درجة حرارة البصلة الجافّة, نسبة الترطيب, والحرارة المضافة للهواء الرطب بازدياد نسبة جريان الهواء, ولكن حمل الترطيب والطاقة الكليّة للهواء الرطب تزداد بازدياد نسبة جريان الهواء في قناة الاختبار. عملية الترطيب بالبخار (1) مع وجود ملف سحب الرطوبة اظهرت زيادة في درجة حرارة البصلة الجافّة, نسبة الترطيب, حمل الترطيب, والحرارة المضافة للهواء الرطب بازدياد نسبة جريان الهواء في قناة الاختبار, ولكن نقصان الطاقة الكليّة بازدياد نسبة جريان الهواء. هذه النتائج المستحصلة يمكن الاستفادة منها في نظام سيطرة عمليات تكييف الهواء في الابنية.


Article
Evaluation of Welding Sequences for Patching in Steel Gears

Authors: Selah S. Abdul Kareem --- Nabeel K. Abid Al Sahib
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2005 Volume: 11 Issue: 1 Pages: 1-19
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The present work deals with an experimental investigation of the effect of surfacing parameters on the final quality of large gear surfacing. This gear forms a vital part of the drive train of cement furnace at the Iraqi Cement Company. The gear is made of DIN CK 45 steel with an analyzed carbon content of 0.429 % and core hardness 185 HV. The gear is considered large, with dimensions of 490 mm in diameter, 250 mm width and 27 mm module, its weight is 350 Kg. The aim of the present work is to study the possibility of repairing this type of gear using SMAW process.The gear surface is cleaned by sand blasting, followed by dye penetrate testing for crack detection. DIN E1-UM350 hardfacing electrode is selected to hardface the gear. This electrode has a nominal composition (0.08 % C, 3.3 % Cr, 1% Mn) and a minimum hardness 350 HV. The gear teeth are surfaced with one, two, and three layers with and without preheating. The preheating temperature is 200 Cْ, which is, selected according to carbon equivalent of the DIN CK 45 base metal. Cracks were observed in the weld metals when surfacing with three layers of E1-UM350 electrode. So, E 8018-B2, and E9018-D1 are selected to butter the gear surface with one layer, followed by two layers of E1-um350 electrode. These low hydrogen electrode are selected based on their mechanical properties compared with DIN CK 45 base metal and low hydrogen content which eliminate hydrogen induced cold cracking. Preheating the gear surface gives good hardness distribution across the weld, HAZ, and base metals due to reducing the cooling rates and prevents hard structure to form at the interface region.A set of destructive and non destructive tests are carried out. Including, tensile wear, impact, chemical analysis, metallographic, micro hardness, macro etchant, and dye penetrate tests. Both of wear and impact resistance of all specimens is greater than the base metal. All weld deposits of E1-UM350 hardfacing electrode gives martensitic structures with different hardness depending on the cooling rates and number of layers. Using of low hydrogen electrodes (E 8018-B2 and E 9018-D1) as buttering layers, solve the cracking problem of weld deposits when surfacing with three layers of E1-UM350 electrodes.

في هذا البحث تم دراسة امكانية اصلاح التروس باستخدام تقنية اللحام اليدوي . الترس المستخدم في هذا البحث هو الفولاذ متوسط الكربون (DIN CK 45) تم جلبه من شركة السمنت العراقية . يشكل هذا الترس جزء حيوي من منظومة التدوير لافران تجفيف السمنت . نسبة الكربون لهذا الفولاذ 0.429% وله صلادة قلب (HV 185) . يعتبر هذا الترس كبيرا نسبيا حيث يزن 350 كغم , قطره الخارجي 490 ملم , عرضه 250 ملم , وتضمينه 27 ملم.تم تنظيف جميع اسنان الترس بواسطة العصف الرملي ومن ثم فحص الترس بالسوائل النافذة للتأكد من عدم وجود شقوق. أسطح الاسنان هيئت بواسطة تجليخها يدويا. كسيت اسنان الترس بطبقة , طبقتين , وثلاث طبقات من سلك (E1-UM350) باستخدام تسخين مسبق وبدونه . التركيب الكيمياوي لهذا السلك ( 0.08% ,C, 3.3 %Cr, 1%Mn ) وصلادته الدنيا (350 Hv ) والتي تمثل الصلادة القصوى لسطح اسنان الترس , وعلى هذا الاساس تم اختيار هذا السلك لاجراء الاكساء . تم اختيار درجة حرارة التسخين المسبق (200° C) لسطح الاسنان اعتمادا على قيمة الكربون المكافئ.لوحظت تشققات في منطقة اللحام عند الاكساء بثلاث طبقات من سلك (E1- UM350) وعليه اختيرت اسلاك لحام واطئة المحتوى من الهيدروجين (E8018-B2) و (E 9018-D1 ) لتزبيد سطح الاسنان ثم تتبع بطبقتين من سلك (E1-UM350) . اختيرت هذه الاسلاك لغرض التزبيد لخواصها الميكانيكية الجيدة اذا ما قورنت بالمعدن الاصلي وكذلك محتواها الواطئ من الهيدروجين وبالتالي تضمن عدم ظهور شقوق من منطقة اللحام او المنطقة المتأثرة بالحرارة.اجريت مجموعة من الفحوصات الاتلافية وغير الاتلافية لغرض تقيم مناطق اللحام ميكانيكيا وميتالورجيا. من هذه الفحوصات , فحص الشد, الصلادة المايكروية , مقاومة البليان , مقاومة الصدمة , فحص السوائل النافذة, التحليل الكيمياوي , الفحص المجهري , والاظهار الماكروي.ان اجراء التسخين المسبق لسطح الأسنان اعطى توزيع جيد للصلادة خلال مناطق اللحام , المنطقة المتأثرة بالحرارة , والمعدن الأصلي من خلال خفض معدلات التبريد ومنع ظهور أطوار صلدة في المنطقة المتأثرة بالحرارة . مقاومة البليان والصدمة لمناطق اللحام كانت اكبر من المعدن الاصلي . اظهر الفحص المجهري لمناطق اللحام لسلك (E1-UM350) بنية المارتنسايت بصلادات مختلفة اعتمادا على معدل التبريد وعدد الطبقات . ان استخدام اسلاك لحام وطئة المحتوى من الهيدروجين كطبقة تزبيد, عالج مشكلة التشقق في منطقة اللحام.


Article
Modeling of the Preheating Effect on Keyhole Laser Welding Efficiency

Authors: K.S. Khashan --- O.A. Hamadi
Journal: Iraqi Journal of Applied Physics Letters الرسائل العراقية في الفيزياء التطبيقية ISSN: 1999656X Year: 2008 Volume: 1 Issue: 1 Pages: 10-15
Publisher: iraqi society for alternative and renewable energy sources and techniques الجمعية العراقية لمصادر وتقنيات الطاقة البديلة والمستجدة

Loading...
Loading...
Abstract

In this work, results of a mathematical analysis of the role of workpiece preheating in laser keyhole welding were presented. This analysis considered the steady-state welding as well as certain range of boundary conditions over which preheating effect would be indicated. This work is an attempt to interpret the role of preheating to increase welding depth and perform keyhole welding with high quality using physical and thermal properties of steel alloys.

Listing 1 - 6 of 6
Sort by
Narrow your search

Resource type

article (6)


Language

English (6)


Year
From To Submit

2017 (1)

2014 (2)

2011 (1)

2008 (1)

2005 (1)