research centers


Search results: Found 47

Listing 1 - 10 of 47 << page
of 5
>>
Sort by

Article
The Relationship Between Hyperglycemia and the Rheumatoid Factor in the Serum of Diabetic Patients
العلاقة بين ارتفاع السكر والعامل الرثوي في مصل مرضى السكري

Author: Ali M. Al-Gharawi علي محمد الغروي
Journal: Baghdad Science Journal مجلة بغداد للعلوم ISSN: 20788665 24117986 Year: 2009 Volume: 6 Issue: 1 Pages: 99-105
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

This study was conducted to determine the relationship between two most common diseases in Iraqis patients , which are Diabetic mellitus (DM) and Rheumatoid Arthritis (RA); seeking rheumatoid factor in hyperglycemic sera. The results revealed that ; 62.5% of hyperglycemic (HG) patients had positive rheumatoid factor (RF) . No difference in number between both gender of HG patients (20 males and 20 females ) , RF reaction was nearly similar in males and females of HG patients ( 12 &13 respectively ) . Only 40% out of patient controls had positive RF . None of the apparently healthy subjects had positive RF .

يعد مرض السكري من أمراض العصر المزمنة والمقيتة , ومن مسببات الالتهابات. لذا تمت دراسة علاقة هذا المرض بداء التهاب المفاصل الريثاني (Rheumatoid Arthritis RA) من خلال دراسة عامل الالتهاب (rheumatoid factor RF) في مصول مرتفعي السكر( hyperglycemia). تم انتقاء (40) مريضا"يعاني ارتفاع السكر على أساس الفحص السريري والمختبري وعشرة أشخاص يعانون أمراضا" مختلفة غير السكري كمجموعة سيطرة وعشرة متبرعين من السويين ظاهريا" ولأعمار مضاهية للمرضى . تم الفحص السريري في العيادة الخارجية لمدينة الطب / بغداد . اجري العمل في المختبرات التعليمية لمدينة الطب . ومن هذا العمل المحدود لوحظ ما يلي : اظهر 62.5% من المرضى مرتفعي السكر(hyperglycemic HG) قيمة موجبة للعامل (RF) بينما اظهرفقط 40% من مجموعة السيطرة القيمة الموجبة للعامل ولم تظهر في نفس الوقت أي قيمة موجبة للعامل (RF) لمجموعة المتبرعين من السويين ظاهريا". كان عدد الرجال والنساء من مرضى مرتفعي السكر متساويا" ( 20 : 20 ). وقد اظهر الجنسين تفاعلا" ايجابيا" +ve للعامل الرثوي (RF) متقاربا" ( 12 رجلا" : 13 أمرأة ) .


Article
Influence of grounded electrode area on breakdown current in RF capcitively coupled plasma
تأثير مساحة القطب المؤرض على تيار الانهيار في البلازما الراديوية ذات الازدواج السعوي

Author: Moyad A. Ahmad مؤيد عبدالله احمد
Journal: Iraqi Journal of Physics المجلة العراقية للفيزياء ISSN: 20704003 Year: 2012 Volume: 10 Issue: 17 Pages: 90-97
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The influence of the grounded electrode area on the ignition voltage in capcitively coupled radio frequency discharge at 13.56 MHz in argon gas is studied experimentally. The results indicate a systematic decrease of the breakdown voltage with increasing grounded electrode area for the same pd value. Results show that the secondary ionization coefficient γ increases with the increase of grounded electrode area. Furthermore, results also the discharge current at the breakdown voltage increases almost linearly with the increase of electrode area suggesting an almost constant current density.

تمت دراسة تأثير مساحة القطب المؤرض على فولتية القدح في التفريغ الراديوي السعوي بالتردد 13.56 MHz في غاز الاركون تجريبيا. تشير النتائج إلى الانخفاض النظامي لفولتية الانهيار مع زيادة مساحة القطب المؤرض لنفس القيم للضرب العددي لضغط الغاز والمسافة الفاصلة بين الأقطاب pd. بينت هذه الدراسة أيضا أن معامل التأين الثانوي γ يزداد مع زيادة مساحة القطب المؤرض .إضافة لذلك تبين إن قيمة تيار التفريغ عند فولتية الانهيار الكهربائي يزداد بشكل يكاد يكون خطيا مع زيادة مساحة سطح القطب المؤرض مما يدل على وجود كثافة تيار ثابتة.

Keywords

Plasma --- argon --- rf-discharge --- Breakdown.


Article
The physiological evaluations of C-reactive protein, anti-cyclic citrullinated peptide antibody and RF in the rheumatoid arthritis patients of Al-Nassyria hospital

Author: Talib F. Abbas
Journal: Muthanna Medical Journal مجلة المثنى الطبية ISSN: 2226146x Year: 2015 Volume: 2 Issue: 1 Pages: 1-4
Publisher: Al-Muthanna University جامعة المثنى

Loading...
Loading...
Abstract

The assessment of autoantibody before clinical onset of Rheumatoid Arthritis, has been helped in establishing early diagnosis. Recent studies on RA described many inflammatory conditions that precede joints inflammations. Anti-CCP and IgM-RF were evaluated in 10-RA patients and in same number as control. Anti-CCP was detected by ELISA and IgM-RF using latex agglutination test, while the CRP was measured by latex turbi-imetric immunoassay, and the ESR was measured by Westergren method. The values of Anti-CCP antibody is more sensitive than the other tests, in 50% were positive, and 50% negative. CRP measures were fluctuated around 37% positive and 63% were negative. ESR values have been shown a significant increase in 90% positive, whereas 10% negative. RF show a significant increase by 60% positivity. The positive value was higher for anti-CCP antibodies in comparison to other markers for RA patients. Interestingly, there were not significant relation between anti-CCP antibody titers and inflammatory markers such as ESR and CRP. However, there is a tighten relation between Anti-CCP and RF had been confirmed.

Keywords

Rheumatoid Arthritis --- Anti-CCP --- RF


Article
Rheumatiod Factor isotype in RheumatiodArthritis patients .

Authors: Jassim T. Khafaji --- Khalidh M. Mousawy --- Nahida R. Abbas
Journal: Journal of the Faculty of Medicine مجلة كلية الطب ISSN: 00419419 Year: 2006 Volume: 48 Issue: 4 Pages: 442-444
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Background: Rheumatiod factor in patients with Rheumatoid arthritis (RA) could be of IgM, IgG, or IgG isotypes.
Aim: To study the occurance of each or all these isotypes in RA patients .
Methods: Enzyme linked Immune Sorbent Assay (ELISA) & Latex agglutination test were used to asses RF in 74 patients with RA.
Results: Using ELISA, 58 (78.4%) patients had positive RF (IgM 48.6%, IgG in 47.3% & IgA in 54.1% ), while only 43 (58.1) patients were positive by AG .
Conclusion All RF isotypes should be assessed in patients with RA

Keywords

RA --- RF --- IgG --- IgM --- IgA --- ELISA --- AG.


Article
Performance of Anticyclic Citrullinated Peptide Antibodies versus Rheumatoid Factor in diagnosis of Rheumatoid Arthritis

Authors: Mohammed Jasim محمد جاسم --- Ali Ibrahim Ali علي ابراهيم علي
Journal: Diyala Journal of Medicine مجلة ديالى الطبية ISSN: 97642219 Year: 2011 Volume: 1 Issue: 1 Pages: 81-90
Publisher: Diyala University جامعة ديالى

Loading...
Loading...
Abstract

The aim of this study was to evaluate the performance of anti-cyclic citrullinated peptide antibodies (anti-ccp) versus Rheumatoid Factor (RF) in the diagnosis of rheumatoid arthritis in serum sample of patients with clinical manifestation of arthritis using ELISA technique.One hundred and twenty patients with clinical presentation of rheumatoid arthritis and fifty apparently healthy individuals (25 males and 25 females) were enrolled in this study. The mean age of patients group and control was 36.45years versus 34.72 years .Among patients, males represented (8.3%) compared with (91.7%) of females. In control group males represented (52%) versus (48%) females.There was a statistical significant difference (p>0.05) between patients and control group in RF and anti-ccp values. Eighty five percent of patients gave positive results for anti-ccp compared with (100%) negative results in control group. RF was detected in (41.66 %) of patients sera compared with (58.33 %) which gave negative results. RF ELISA gave negative results in (100%) of control group .Only 10(8, 33%) out of 120 patients gave negative results in RF and anti-ccp ELISA, compared with 42(35%) out of 120 gave positive results in both tests. In 60(50%) out of 120 RA patients RF gave negative results and at the same time gave positive results when retested using anti-ccp ELISA .Only 8(6.66%) out of 120 RA patients gave negative result in anti-ccp ELISA technique and RF was detected in positive value.The sensitivity of anti-ccp ELISA was (85%) versus (41.66%) for RF. The Specificity of anti-ccp ELISA was (55.55%) versus (14.28%) for RF. Positive predictive value for anti-ccp ELISA was 41.17% versus (84%) for RF. Negative predictive value for anti-ccp ELISA was 55.55% versus 14.28 for RF ELISA .False positive value in anti-ccp ELISA was 58.82% versus 16%for RF ELISA. False negative value in anti-ccp ELISA was 44.44% versus 85.71%for RF .This study concludes that anti-ccp ELISA was more sensitive and specific in diagnosis of RA than RF ELISA technique.

Keywords

RA --- RF --- Anti-ccp --- ELISA --- sensitivity --- Specificity.


Article
Diagnostics of low-pressure capacitivelycoupled RF dischargeargon plasma
تشخيص التفريغ الكهربائي عند الضغط الواطئ لمنظومة الاقتران السعوي ذو الترددات الراديوية لبلازما الاركون

Loading...
Loading...
Abstract

Low-pressure capacitively coupled RF discharge Ar plasma has been studied using Langmuir probe. The electron temperature, electron density and Debay length were calculated under different pressures and electrode gap. In this work the RF Langmuir probe is designed using 4MHz filter as compensation circuit and I-V probe characteristic have been investigated. The pressure varied from 0.07 mbar to 0.1 mbar while electrode gap varied from 2-5 cm. The plasma was generated using power supply at 4MHz frequency with power 300 W. The flowmeter is used to control Argon gas flow in the range of 600 standard cubic centimeters per minute (sccm). The electron temperature drops slowly with pressure and it's gradually decreased when expanding the electrode gap.As the gas pressure increases, the plasma density rises slightly at low gas pressure while it drops little at higher gas pressure. The electron density decreases rapidly with expand distances between electrodes.

تم دراسة التفريغ الكهربائي لبلازما الاركون عند الضغط الواطئ لمنظومة الاقتران السعوي ذو الترددات الراديوية باستخدام مجس لانكمور. وكذلك تم حساب درجة حرارة الالكترون وكثافة الالكترون وطول ديباي مع اختلاف الضغوط والمسافة بين القطبين. في هذا العمل صمم مجس لانكمور ذو الترددات الراديوية باستخدام مرشح 4 ميكا هيرتز كدائرة تعويض وبحثت العلاقة بين الفولتية والتيار. تم تغيير الضغط من 0.07 الى 0.1 ملي بار بينما تم تغيير المسافة بين القطبين من 2 الى 5 سنتمتر. استخدم مجهز قدرة ذو تردد 4 ميكا هيرتز لتوليد البلازما بطاقة 300 واط. وكذلك استخدم مقياس التدفق بمدى 600 سنتمتر مكعب بالدقيقة للسيطرة على تدفق غاز الاركون.ووجد ان درجة حرارة الالكترون تتناقص مع زيادة الضغط وتتناقص ايضا مع زيادة المسافة بين الاقطاب بينما تتزايد كثافة الالكترون عند زيادة الضغط وتتناقص عند زيادة المسافة بين الاقطاب.


Article
Effect of sputtering power on optical Properties of RF sputtering deposited Ti6Al4V Thin Films
تأثير القدرة المجهزة لمنظومة الترذيذ بالترددات الراديوية على الخصائص البصرية لأغشية Ti6Al4V الرقيقة

Authors: Mohammed K. Khalaf محمد خماس خلف --- Dawood Salman Ali داود سلمان علي
Journal: Iraqi Journal of Physics المجلة العراقية للفيزياء ISSN: 20704003 Year: 2017 Volume: 15 Issue: 33 Pages: 71-77
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Ti6Al4V thin film was prepared on glass substrate by RF sputtering method. The effect of RF power on the optical properties of the thin films has been investigated using UV-visible Spectrophotometer. It's found that the absorbance and the extinction coefficient (k) for deposited thin films increase with increasing applied power, while another parameters such as dielectric constant and refractive index decrease with increasing RF power.

تم تحضير اغشية رقيقة من سبيكة (Ti6Al4V) على ارضيات زجاجية باستخدامتقنية الترذيذ بالترددات الراديوية.تم دراسة تأثير القدرة المجهزة على الخصائص البصرية للأغشية الرقيقة باستخدام تقنية امتصاص الأشعة المرئية فوق البنفسجية.وجد ان معاملي الامتصاص والخمود يزدادان بزيادة الفولتية المجهزة.بينما باقي المعاملات مثل ثابت العزل ومعامل الانكسار تقل بزيادة الفولتية المسلطة.


Article
Effect of Argon and oxygen pressure on Zn magnetron plasma produced by RF power supply
تاثير ضغط الاركون والاوكسجين على بلازما الخارصين الممغنطة والمتولدة بواسطة مجهز قدرة ذو الترددات الراديوية

Loading...
Loading...
Abstract

In this work, the plasma parameters (electron temperature and electron density) were determined by optical emission spectroscopy (OES) produced by the RF magnetron Zn plasma produced by oxygen and argon at different working pressure. The spectrum was recorded by spectrometer supplied with CCD camera, computer and NIST standard of neutral and ionic lines of Zn, argon and oxygen. The effects of pressure on plasma parameters were studied and a comparison between the two gasses was made.

في هذا العمل، تم تحديد معلمات البلازما (درجة حرارة الإلكترون وكثافة الإلكترونات) من خلال تحليل طيف الانبعاث الضوئي (OES) التي تنتجها بلازما الترددات الراديوية الممغنطة للخارصين RF المتولد بوجود الأوكسجين والأركون و بالضغوط المختلفة. تم تسجيل الطيف بواسطة المطياف او المجهز بكاميرا نوع CCD، الكمبيوتر، NIST لخطوط الطيف الذرية والأيونية للزنك، والأركون والأوكسجين .وقد تم دراسة تأثير الضغط على معلمات البلازما وتم المقارنة بين الغازين.


Article
The Influence of RF power, pressure and substrate temperature on optical properties of RF Sputtered vanadium pentoxide thin films
تاثير الطاقة والضغط ودرجة حرارة الركيزة على الخصائص البصرية للاغشية الرقيقة لخامس اوكسيد الفاناديوم باستخدام الترذيذ بالترددات الراديوية

Authors: Ibrahim K. salman إبراهيم خلف سلمان --- N.K. Hassan نديم خالد حسن --- Mohammed K. Khalaf محمد خماس خلف
Journal: Iraqi Journal of Physics المجلة العراقية للفيزياء ISSN: 20704003 Year: 2018 Volume: 16 Issue: 39 Pages: 42-47
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The V2O5 films were deposited on glass substrates which produce using "radio frequency (RF)"power supply and Argon gas technique. The optical properties were investigated by, UV spectroscopy at "radio frequency" (RF) power ranging from 75 - 150 Watt and gas pressure, (0.03, 0.05 and 0.007 Torr), and substrate temperature (359, 373,473 and 573) K. The UV-Visible analysis shows that the average transmittance of all films in the range 40-65 %. When the thickness has been increased the transhumance was decreased from (65-40) %. The values of energy band gap were lowered from (3.02-2.9 eV) with the increase of thickness the films in relation to an increase in power, The energy gap decreased (2.8 - 2.7) eV with an increase in the pressure and substrate temperature respectively.

تم ترسيب أغشية رقيقة من خامس اكسيد الفاناديوم على ركائز زجاجية التي تنتج باستخدام طاقة التردد الراديوي وتقنية غاز الأرجون، وتم بحث الخواص البصرية بواسطة دراسة مطيافية مرئية فوق بنفسجية عند قدرة التردد الراديوي من 75 - 150 واط وضغط الغاز 0.03 تور، .050 تور و 0.007 تور، ودرجة حرارة الركيزة (359، 373، 473 و 573) كلفن. أظهر التحليل الطيفي المرئي و للأشعة فوق البنفسجية أن متوسط نفاذ جميع الأغشية يكمن في نطاق 40-65 ٪ و عندما زاد السمك انخفضت نسبة الانتقال مـــن (65 -40) %. و انخفضت فجوة النطاق الضوئي للغشاء من 3.02 إلى 2.9 الكترون فولت, مع زيادة سماكة الأغشية مقارنة بالزيادة في القدرة، من ناحية أخرى انخفضت فجوة النطاق من 2.8 إلى 2.7 الكترون فولت, مع زيادة الضغط ودرجة حرارة الركيزة على التوالي.


Article
The Growth Characteristics of RF-Magnetron Sputtered Nanocrystalline TiO2 Thin Films

Authors: Azhar K. Sadkhan --- Suaad A. Mohammed --- Mohammed K. Khalaf
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2018 Volume: 36 Issue: 2 Part (B) Engineering Pages: 128-130
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

In this paper, RF Magnetron sputtered TiO2 thin films deposited onglass slices at various powers (75,100,125 and 150) Watt for (1.5) hour anddifferent thickness (62.5-88-118 and 132.6) nm, the TiO2 thin films annealed with400°C for 2 hour and the morphology and structure of these films are describedby X-ray diffraction XRD and atomic force microscopy AFM to show the phasestructure. X-ray diffraction investigation uncovered that the crystalline size of theTiO2 thin films displays an expanding pattern with increasing the sputteringpower. The preferred orientation of (101) was watched for the films depositedwith sputtering power of (75,100,125 and 150) Watt

Listing 1 - 10 of 47 << page
of 5
>>
Sort by
Narrow your search

Resource type

article (47)


Language

English (41)

Arabic (2)

Arabic and English (1)


Year
From To Submit

2019 (5)

2018 (9)

2017 (6)

2016 (3)

2015 (3)

More...