Article
Effect Of Fault Resistance On The Performance Of Mho Relays
تأثير مقاومة العطل على أداء المرحلات المسامحية

Author: Noha Abed Al-bary Al-jawady نهى عبدالباري الجوادي
Journal: AL Rafdain Engineering Journal مجلة هندسة الرافدين ISSN: 18130526 Year: 2008 Volume: 16 Issue: 2 Pages: 42-3
Publisher: Mosul University جامعة الموصل

Loading...
Loading...
Abstract

Abstract For distance protection to perform its function perfectly without errors, it should be characterized with ideal characteristics that is to operate within forward faults those are included by protection zone, and to exclude the outer faults. In order to get an ideal tripping area for distance relays, all the factors and limitations imposed by power system on the measuring accuracy of distance relays must be identified. This paper includes a study of the fault resistance effect on the performance of distance protection when using mho relays. This study is done by steady state analysis of fault circuit to find the current & voltage at the relay location for different value of fault resistance for Line to ground faults and double line to ground faults. Keywords: fault resistance, Protective relays, Mho relays.

الخلاصة لضمان قيام حماية المسافة بدورها بشكل جيد ودون حدوث تقصير في الأداء, يجب أن تتصف مرحلة المسافة بخواص عمل مثالية, بحيث تعمل في حالة الأعطال الأمامية والواقعة ضمن القطاع المحمي من قبل المرحلة وتستثني الأعطال التي تقع خارج القطاع المحمي من قبل المرحلة. ومن اجل الحصول على خواص عمل مثالية للمرحلة, يجب الإلمام بجميع العوامل والمحددات المفروضة من قبل منظومة القدرة والتي تؤثر على عمل المرحلة. يتناول البحث دراسة لواحد من هذه العوامل المؤثرة على دقة عمل حماية المسافة وعند استخدام المرحلات المسامحية, حيث تم بيان تأثير مقاومة العطل على عمل أنواع مختلفة من المرحلات المسامحية, وتمت هذه الدراسة بتحليل دائرة الحالة المستقرة لأعطال الطور والطورين مع الأرض وعند قيم مختلفة لمقاومة العطل.


Article
Phasor Based Numerical Mho Distance Relay: Model Development

Authors: Dr. Qais M. Alias1 --- Ameer A. Mohammed2
Journal: IRAQI JOURNAL OF COMPUTERS,COMMUNICATION AND CONTROL & SYSTEMS ENGINEERING المجلة العراقية لهندسة الحاسبات والاتصالات والسيطرة والنظم ISSN: 18119212 Year: 2016 Volume: 16 Issue: 1 Pages: 20-28
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

Abstract –The advancement in science and engineering led to the development of relays, started by electromechanical, and followed by solid-state, and lately digital and numerical relays. Numerical relays are the result of the application of microprocessor technology in the relay industry. This paper describes an approach for detailed modeling of a numerical distance relay using MATLAB/SIMULINK. The distance relaying is for use in a modeled EHV transmission system. A section of 400 kV, 350 km length transmission lines is chosen for the case study. The numerical relay is modeled having Mho characteristics suitable for three-zone distance relaying. A set of tests were performed to investigate the applicability and consistency of the developed relay model. The results showed that the numerical relay model respond satisfactorily to fault incidents and in accordance with the expected results of the performed tests.


Article
Improving the Response of Electromagnetic Servo Relay Drives (ESRD) Using PID Comp. and Multi-level Voltages

Author: Saad A-R. Makki
Journal: Journal of Engineering and Sustainable Development مجلة الهندسة والتنمية المستدامة ISSN: 25200917 Year: 2012 Volume: 16 Issue: 4 Pages: 206-219
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

Electromagnetic Servo Relay Drive (ESRD) devices are small, simple and reliable devices. Special types of ESRD Utilizing Pulse Width Modulation (PWM) technique to input driving voltage are used in guidance and control systems. In this Paper a simulation, using MATLAB and Simulink were performed. To improve the rising time and time response of the mechanical armature angular position, the input voltage has been selected to do that. Two techniques have been proposed, first is the PID compensator and second is the reshaping / reforming the input pulse voltage. The effects on the different system parameters has been declared and discussed in addition to the comparison between the two used methods. Results show that the 2nd method is more effective and give an improvement in star sting and rising time by about 20% compared with 6% improvement in 1st method. The second method shows an increment in power consumption which lead in heat dissipation.

ان ادوات القيادة السرفوية ذات مبدأ الرلي الكهرومغناطيسي(ESRD) هي ادوات صغيرة و بسيطة وذات معولية (اعتمادية). هنالك نوع خاص من الـ (ESRD) يستخدم مبدأ التحميل بعرض النبضة (PWM) يجد له تطبيق في منظومات السيطرة والتوجيه. تم استخدام برامج محاكات ماثلاب والسميلنك MATLAB and Simulink. لأجل تحسين زمن الصعود وزمن الاستجابة للخرج الزاوي للذراع المتحرك وان الدخل الفولتي قد اختير لتحقيق ذلك. لقد تم أستخدام اسلوبين, الاسلوب الاول تم عن طريق استخدام معوض نوع PID والاسلوب الثاني هو باعادة تشكيل / تغيير شكل دخل الفولتية النبضية. تم مناقشة وايجاد التأثيرات على معالم المنظومة المختلفة بالاضافة الى ايجاد مقارنة بين الطريقتين المستخدمتين. اظهرت النتائج بان الطريقة الثانية اكثر فعالية وتعطي تحسين في زمن البدء وزمن الصعود مقداره 20% مقارنة مع 6% تحسين في الطريقة الاولى. اظهرت الطريقة الثانية مساوئ في زيادة القدرة المستهلكة وبالتالي زيادة الحرارة المتبددة.


Article
Study of the Influence of Mechanical Parameters on the Behavior and Response of Electromagnetic Servo Relay (ESR)

Loading...
Loading...
Abstract

Abstract: The Relay is widely used in civil, industrial and military equipment. The Relay is considered to be one of the indispensable actuators for electric power and control flying objects and systems. Relays reliability strongly influences the system reliability.The mathematical model of the servo is introduced including the electrical, magnetic and dynamic parts.Simulations, using Matlab and Simulink, were performed. An improvement to the mathematical model has been carried through simulation which reflected on the results gained. Results of the effect and influence of magnetic materials and some important mechanical parameters like stiffness, viscosity, and copper insulator thickness, on the dynamic performance of the servo were presented. The results can lead to improving the servo performance and get the right design of parameters and right choice of materials.


Article
New Adaptive Non _ communication TL Protection Scheme with Three Phase Auto_Reclosing
طريقة تضبيط جديدة لحماية خط النقل من العطب بدون إتصالات مع إستخدام إعادة غلق الأطوار الثلاثة ذاتيا

Authors: Dr. M. F. Al-Kababjie د. مأمون فاضل الكبابجي --- Dr. Nathim Sh. Rasool د. ناظم شيت رسول
Journal: AL Rafdain Engineering Journal مجلة هندسة الرافدين ISSN: 18130526 Year: 2007 Volume: 15 Issue: 3 Pages: 50-59
Publisher: Mosul University جامعة الموصل

Loading...
Loading...
Abstract

Abstract In This paper a new adaptive non-communication method offers 100% Over Head Transmission Line fault clearance instantaneously, is presented. This Adaptive scheme adjusts distance Measuring Protection covering full TL in First zone with out waiting the communication inter-tripping signals, with high percentage successful three phase Auto_ Reclosing rate. This has been achieved by arrangement of three instantaneous, fundamental frequency, rms Under voltage Supervisory Relays controlling Auto_Reclosing command applied to the Circuit Breaker. The researchers presented a new philosophy to restore Over Head TL in more reliable and dependable method than the common existing one. The method utilizes a three phase monitoring Voltage Relay at each end of the OHTL which control the Reclosing Command. This new method is applicable approximately to all types of TL protection Relays (conventional or Modern Numerical Relays). Key-Words: Non communication TL protection, Adaptive Auto_Reclosing Relays, Distance Measuring Protection.

الخلاصة تم تقديم طريقة تضبيط جديدة لاتعتمد على انتقال المعلومات بين الأطراف وتعمل على إزالة العطل لخطوط النقل بصورة آنية وبتغطية 100% 0 وهذه التغطية للحيز الأول تعمل بدون انتظار الإشارة من الطرف الآخر على إعادة الغلق للأطوار الثلاثة ويتم العمل بواسطة مرحلات آنية تتحسس انخفاض فولتية (جذر معدل التربيع) لمركبة التردد الأساسي.تم استعراض فلسفة جديدة (لاعادة غلق الأطوار الثلاثة ذاتيا), تختلف عن المتوفرة وتستخدم الطريقة ثلاثة مرحلات تتحسس انخفاض الفولتية عند نهاية كل خط نقل, للسيطرة على إعادة الإغلاق ويمكن استخدام هذه الفلسفة مع كل أنواع مرحلات الحماية القديمة والحديثة.


Article
EFFECT OF VARYING AIRGAP LENGTH ON PERFORMANCE OF LINEAR AND NON LINEAR ELECTROMECHANICAL
تأثير تغيير طول الفجوة الهوائية على أداء المرحلات الكهروميكانيكية الخطية واللاخطية

Author: Ali Abdul Razzaq Al - Tahir علي عبد الرزاق عباس الطاهر
Journal: Al-Qadisiyah Journal for Engineering Sciences مجلة القادسية للعلوم الهندسية ISSN: 19984456 Year: 2009 Volume: 2 Issue: 2 Pages: 514-531
Publisher: Al-Qadisiyah University جامعة القادسية

Loading...
Loading...
Abstract

This work studies the effect of varying air-gap length on performance and behavior of electromechanical relays. When the air-gap length changed due to mechanical movement producing from air or liquid pressure in pneumatic or hydraulic system, respectively therefore; the magnetic reluctance is change, that is the inductive properties be effected and as a result of that, the switching value of voltage and current are changed drastically in electromechanical relays. It can be controlled on the min. and maximum value for air pressure in a pneumatic system by controlling on the minimum and maximum value corresponding to voltage and current in the system relay. Two models of transducers are used in this study; the first is variable reluctance displacement transducer studies the intensity of magnetic field lines in 2-D, the intensity of magnetic field vectors and summation of magnetic field intensity contours estimated. The magnetic force is determined with air- gap length changing from (0.8 to 0.2) cm, gradually. Second model is variable differential reluctance transducer. The same results obtained in first model are determined in second model with two cases, armature in mid-way and armature shifted to right side by (0.4) cm. The magnetic force is determined along the line of axisymmetric and in Y direction of armature location. The results show from ANSYS 5.3 and MATLAB - 7 - simulation, the magnetic field increases with decreases of air-gap length in first model and for the second model the magnetic field concentrated in mid - way armature position and increase in the side where the air - gap length reduced and reduced in the side where the air – gap length increasing.

هذا البحث يدرس تاثير تغييرطول الفجوة الهوائية على أداء وتصرف المرحلات الكهروميكانيكية. أن تغيير طول الفجوة نتيجة لحركة ميكانيكية ناجمة من ضغط الهواء أو السائل في المنظومة الهوائية أو الهيدروليكية على الترتيب , لذلك تتغير المعاوقة المغناطيسية التي بدورها تؤثر على الخواص الحثية وكنتيجة لذلك تتغير قيمة الفولتية والتيار في ملف المرحل الكهروميكانيكي بشكل ملحوظ. يمكن السيطرة على قيمة الدنيا والعليا لضغط الهواء في منظومة معينة عن طريق السيطرة على القيمة الدنيا والعليا للتياروالفولتية المناظرة لها في ملف المرحل .هنالك موديلين من المتحسسات أستخدمت في هذه الدراسة,الأول هو متحسس معاوقة متغييرالطول بأطوال مختلفة للفجوة والذي تم فيه حساب شدة خطوط الفيض المغناطيسي ذات البعدين, شدة المجال المغناطيسي كمتجهات, وشدة المجال المغناطيسي على أساس تدرج الألوان أضافة الى حساب قوة المجال وبعض المواصفات ذات العلاقة.أن القوة المغناطسية حددت نتيجة لتغير الفجوة من (0.8الى0.2) سم تدريجيا.الموديل الثاني هومتحسس معاوقة تفاضيلي التغيروبموقعين مختلفين للجزء المتحرك مرة في منتصف الطريق بين الملفيين ومرة أخرى أزيح الى اليمين بمقدار (0.2)سم. لقد تم حساب نفس الخواص في الموديل الثاني أضافة الى حساب قوة المجال المغناطيسي على طول خط التناظر الأفقي وعموديا في منطقة الفجوة الهوائية. أظهرت النتائج الحاصلة من المحاكاة بمساعدة برنامجِ المحاكاة .ANSYS الأصدار 5.3 و بأستخدام الحزمة البرمجية مختبر المصفوفات الأصدار السابع للموديل الأول أن قوة المجال المغناطيسي تزداد مع نقصان طول الفجوه الهوائية أما بالنسبة الموديل الثاني, فقد أظهرت النتائج أن قوة المجال المغناطيسي تتمركز قرب الجزء المتحرك للمرحل وتزداد في الجهة التي يقل فيها طول الفجوة الهوائية وتقل بالمقابل في الجهة التي يزداد فيها طول الفجوة


Article
Automated Power Factor Correction for Smart Home

Authors: Basil H.Jasim --- Bilal Naji Alhasnawi
Journal: Iraqi Journal for Electrical And Electronic Engineering المجلة العراقية للهندسة الكهربائية والالكترونية ISSN: 18145892 Year: 2018 Volume: 14 Issue: 1 Pages: 30-40
Publisher: Basrah University جامعة البصرة

Loading...
Loading...
Abstract

In the current scenario, power factor has become an important concern in all industries. Poor power factorgives rise to many problems which result in financial loss of industries and also for the commercial users. The mainconcern of this work is to improve the usage of real power with respect to reactive power hence improving the powerfactor. Here we have used the technique of relay switching method with a capacitor so that any drop in power factorcan be sensed by the controller and switch the capacitor as required. This will not only help to improve power factorbut also demand of electricity supply on utility side will be reduced. The Significance of this work is to build anAPFC (Automatic Power Factor Correction) Unit. The APFC appliance calculates the reactive power (KVAR)expended by a system’s load and compensates the lagging PF (power factor) utilizing capacitances from capacitorbanks.


Article
Online Monitoring and Controlling Water Plant System Based on IoT Cloud Computing and Arduino Microcontroller

Authors: Ali Najim Abdullah --- Ahmed Mohamed Merza --- Bdoor Alaa Mahmood
Journal: Journal of University of Babylon مجلة جامعة بابل ISSN: 19920652 23128135 Year: 2017 Volume: 25 Issue: 4 Pages: 1230-1240
Publisher: Babylon University جامعة بابل

Loading...
Loading...
Abstract

Water is basis of the existence of life on earth and its invaluable because it’s an essential requirement for all the human beings but, presently water preparation and processing systems are suffering from different problems such as real-time operations problems, loss of large amounts of water in the liquidation and distribution operations, less amount of water sources, i.e. The increase in water problems coincides with the increase in population numbers and residential areas such as (water distribution, consumption, Interrupted water sources problems as well as water quality). Therefore, to eliminate these problems and make more efficient water systems, effective and reliable there is necessity for accurate monitoring and proper controlling system. In this paper, we are focusing on the design of water system in real-time and on the continuous monitoring of water based on IoT cloud computing and Arduino microcontroller. Water system with proper control algorithm and continuous monitoring any place and any time makes a stable distribution so that, we can have a record of height of water in tanks and we can change the devices status in the plant. Internet of things is a network of physical connected objects equipped with software, electronics circuits, sensors, and network connection part which allow monitoring and controlling anywhere around the world. Through using cloud computing proved by free severs, the water system’s data continuously is uploaded to cloud allowing the real time monitoring operation by the use of sensors and microcontroller (Arduino) as Minicomputer to control and monitor the system operation from cloud with efficient (client to server) connection.

يعد الماء أساس وجود الحياة على كوكب الارض ولا يقدر بثمن لأنه يمثل الحاجة الأساسية لجميع البشر، ولكن في الوقت الحاضر، تعاني أنظمة إعداد ومعالجة المياه الكثير من المشاكل المختلفة مثل مشاكل عمل الانظمة بالوقت الحقيقي، وفقدان كميات كبيرة من المياه في عمليات التصفية والتوزيع وتناقص مصادر المياه مثل انخفاض معدل سقوط المطر. وتزداد مشاكل المياه مع الزيادة في أعداد السكان والمناطق السكنية منها مشاكل توزيع المياه والاستهلاك وانقطاع مصادر المياه وكذلك جودة المياه. ولهذه فان القضاء على هذه المشاكل يجعل أنظمة المياه أكثر كفاءة وفعالية وموثوقية اذ ان هناك ضرورة لمراقبة الدقيقة ونظام تحكم سليم. في هذا البحث سوف نسلط الضوء على تصميم نظام لمراقبة المستمرة على عمليات معالجة وتوزيع المياه بالوقت الحقيقي المستندة على تقنية الكمبيوتر السحابي والمتحكم الدقيق من نوع (أرد ينو). ان انظمة المياه مع الخوارزمية التحكم المناسبة وامكانية المراقبة والرصد المستمر من أي مكان وفي أي وقت يجعل عملية توزيع المياه منتظمة بحيث أننا يمكن أن نسجل ارتفاع مستوى المياه في الخزانات وأيضا تغيير حالة الأجهزة في المحطة. إنترنت الأشياء هو عبارة عن شبكة من الأشياء المادية مرتبطة مجهزة ببرامج ودوائر الكترونية وأجهزة الاستشعار ودوائر لاتصال بالشبكة بحيث يسمح بعمليات الرصد والمراقبة في أي مكان في جميع أنحاء العالم. ومن خلال استخدام الكمبيوتر السحابي الذي توفره الخوادم مجاناً فان بيانات منظومات المياه يتم تحميلها بشكل مستمر إلى السحابة ممكنا بذلك الرصد في الوقت الحقيقي لعمليات باستخدام أجهزة استشعار والمتحكم الدقيق من نوع (أرد ينو) والذي يعتبر كالكمبيوتر مصغر لمراقبة ورصد وتشغيل النظام من سحابة مع كفاءة الاتصال باستخدام بروتكول (العميل إلى الخادم).

Listing 1 - 8 of 8
Sort by
Narrow your search

Resource type

article (8)


Language

English (7)


Year
From To Submit

2018 (1)

2017 (1)

2016 (1)

2012 (2)

2009 (1)

More...