research centers


Search results: Found 3

Listing 1 - 3 of 3
Sort by

Article
Concentration of Residual Chlorine in Tikrit University Water Supply Network
تراكيز الكلور المتبقي في شبكة ماء جامعة تكريت

Author: عفاف جدعان عبيد
Journal: Iraqi Journal of Civil Engineering المجلة العراقية للهندسة المدنية ISSN: 19927428 Year: 2011 Volume: 7 Issue: 1 Pages: 18-29
Publisher: University of Anbar جامعة الانبار

Loading...
Loading...
Abstract

Chlorine is considered as one of the most important disinfectants because of its availabilityin a wide form and in acceptable cost. Measurements of residual chlorine are very essential toassure the presence of disinfection at various locations of the water distribution system. Theaim of the present work is to find the residual chlorine concentrations in potable water whichleaves Tikrit University water supply plants. pH-, water temperature and water turbidity arealso measured. Sixty samples of tap water are tested during November 2009 till April 2010.The results show that range of residual chlorine is 0.2-4mg/l) and most of the measured valuesare higher than the maximum permissible limit according to Iraqi standards( 417/1974 )The data indicated that pH is within the range of (7-8.2) and there is no clear relationshipbetween pH and residual chlorine concentration. It is found that there an inverseproportionality between residual chlorinean and temperature . Same trend is found between residual chlorine and turbitiy. The Conductivity and total dissolved solid of drinking water waswithin the permitted level by the Iraqi standers

يعتبر الكلور من أهم المعقمات لتوفره بصورة واسعة وبكلفة معتدلة في اغلب مناطق العالم. ان وجود الكلور في مختلف مناطق شبكات الاسالة مهمجدا للتاكد من وجود التعقيم للمياه. يهدف البحث إلى إيجاد تركيز الكلور المتبقي في الماء الخارج من محطة إسالة ماء جامعة تكريت وبعض المناطق التابعة لهاضمن جامعة تكريت وملحقاتها.اختيرت هذه المناطق على مسافات مختلفة من المحطة وذلك لمعرفة وجود الكلور المتبقي في مياه الشرب ضمن الحدود المسموحة.ودرجة حرارة الماء والعكورة لستين عينة من ماء الشرب pH تم قياس تركيز الكلور المتبقي وكذلك قيم بعض العوامل المؤثرة ع ليه مثل الدالة الحامضية. خلال فترة الدراسة التي امتدت بين شهري تشرين الثاني ٢٠٠٩ الى نيسان ٢٠١٠٤ ملغرام/ لتر. ان معظم تراكيز - تم استعمال نماذج إحصائية لتحليل البيانات حيث بينت النتائج ان تركيز الكلور المتبقي تراوح بين ٠٫٢- فقد تراوحت بين ٧ pH الكلور المتبقي كانت اعلى من القيم المسموح بها وفق المعايير القياسية لمياه الشرب العراقية. اما بالنسبة لقيم الدالة الحامضية٨٫٢ واظهرت ا لنتائج عدم وجود علاقة واضحة بين هذه القيم وتركيز الكلور المتبقي. كذلك اشارت النتائج ان هناك تناسبا عكسيا بين درجة الحرارة وترك يزالكلور المتبقي وكذلك تناسب تركيز الكلور عكسيا مع الكدرة. أما بالنسبة للتوصيلية الكهربائية والاملاح الذائبة الكلية فقد كانت ضمن حدودالمواصفات القياسية العراقية.


Article
Comparability Study between Digital and Visual Colorimeter by using of Chlorine Indicators of DpD No.1 and DpD No.3 under practical conditions
دراسة مقارنة بين جهاز قياس الكلور الرقمي وجهاز قياس الكلورالعيني بواسطة استخدام كواشف الكلور الدي بي دي رقم 1 والدي بي دي رقم 3 تحت ظروف قياسية

Author: Fulath Abdul-RedahMuhsin فولاذ عبد الرضا محسن
Journal: Al-Kufa University Journal for Biology مجلة جامعة الكوفة لعلوم الحياة ISSN: 20738854 23116544 Year: 2014 Volume: 6 Issue: 1 Pages: 10-22
Publisher: University of Kufa جامعة الكوفة

Loading...
Loading...
Abstract

All public drinking water system was required to measure the levels of residual chlorine in a practically accurately instruments to ensure that the water was adequately disinfected. This experimental study was carried out to compare under practical condition in laboratory the test results of free and total chlorine in the water samples between digital colorimeter and visual colorimeter by using of chemical indicatorreagentsof ((DpD number (1)) for testing of free chlorine in water samples, and ((DpD number (3)) for testing of total chlorine in water samples. The experiments lasted from (1/10/2011 to 1/5/2012). The study was conducted in the Laboratories of Al-Kufa Technical Institute in Al-Kufa city that belong to Al-Najaf governorate about 165 Km to the south of Baghdad, and 60 km to the south of Babylon governorate.200 experiments were done in the laboratory, by made of 2 experiments in each day through a standards laboratory conditions. There was a highly statistical significant difference (p=0.000), in comparing between digital calorimeter and visual colorimeter of both free and a total chlorine test results. There was a highly differences in the mean when was comparison of the digital colorimeter with the visual colorimeter of both all free and total chlorine experiment. There was a strong direct correlation between digital colorimeter experimental results and contact time in both all free and total chlorine experiments, while there was a weak direct correlation between visual colorimeter and contact time in all free and total chlorine experiments. From the all tested results of experiment that was derived from this study, the study recommend to practically adaptation of a digital colorimeter instead of visual colorimeter in all the chlorine residual test results that was done by ministry of health inspectors in all governorates in monitoring of drinking water, and for more accurate and sensitive test result we recommend to adapted of digital colorimeter in all researches when tracing of chlorine residual of different water samples.

ان كل منظومة ماء شرب بحاجة لقياس مستويات الكلورين المتبقي باجهزة دقيقة عمليا للتاكد من ان الماء تم تنقيته بصورة مظبوطة.اجريت هذه الدراسة التجريبية للمقارنة تحت ظروف قياسية في المختبر نتائج فحوصات الكلور الحر والكلي في نماذج الماء بين جهاز قياس الكلور الرقمي وجهاز قياس الكلور العيني بواسطة استخدام الكواشف الكيمياوية ((الدي بي دي رقم (1)) لقياس الكلورين الحر في نماذج الماء, واستخدام ((الدي بي دي رقم (3)) لقياس الكلورين الكلي في نماذج المياه. استمرت هذه الدراسة من (1/10/2011 الى 1/5/2012) . تمت الدراسة في مختبرات المعهد التقني الكوفة والتابع لمحافظة النجف الاشرف حوالي 165 كم للجنوب من بغداد, و60 كم للجنوب من محافظة بابل. 200 تجربة قد تم اجرائها في المختبر, بواسطة العمل بتجربتين في كل يوم تحت ظروف قياسية في المختبر.كان هنالك فروق معنوية احصائية كبيرة (p=0.000) عند المقارنة بين جهاز قياس الكلور الرقمي مع جهاز قياس الكلور العيني لكل من فحوصات الكلور الحر والكلور الكلي. كان هنالك فرق كبير في المتوسط الحسابي عند المقارنة بين الجهازين بالنسبة لكل فحوصات الكور الحر والكلي. كان هنالك ارتباط موجب وقوي بين نتائج تجارب جهاز الكلور الرقمي ووقت التلامس لكل من فحوصات الكلور الحر والكلي, بينما كان هنالك ارتباط موجب وظعيف بين نتائج تجارب جهاز قياس الكلور العيني ووقت التلامس لكل من فحوصات الكلور الحر والكلي.من جميع نتائج التجارب المعمولة والمستخلصة من هذه الدراسة, توصي الدراسة من تبني الاستخدام العملي لجهاز قياس الكلورالرقمي بدلا من جهاز قياس الكلور العيني في جميع فحوصات الكلور المتبقي من قبل المفتشين التابعين لوزارة الصحة في جميع المحافظات عند مراقبة مياه الشرب. كما توصي الدراسة لنتائج اكثر دقة وحساسية من تبني استخدام جهاز قياس الكلور الرقمي في جميع البحوث للتقصي عن الكلور الحر والمتبقي في مختلف نماذج المياه.


Article
Removal of Residual Chlorine from Water by Adsorption Using Apricot Shell Activated Carbon
إزالة الكلور المتبقي في الماء عن طريق الامتزاز باستخدام الكربون المنشط المحضر من قشرة نوى المشمش

Author: Bakhtiar K. Hamad بختيار كاكل حمد
Journal: Diyala Journal For Pure Science مجلة ديالى للعلوم الصرفة ISSN: 83732222 25189255 Year: 2018 Volume: 14 Issue: 4 Pages: 138-153
Publisher: Diyala University جامعة ديالى

Loading...
Loading...
Abstract

Apricot Shell Activated Carbon (ASAC) was examined for removal of residual chlorine in aqueous solution through the adsorption process. The effects of solution pH, agitation time, and initial concentrations were estimated. The results showed that the adsorption increased as the contact time increased and the initial concentration decreased, while the high adsorption was at pH=2. Langmuir, Freundlich and Temkin isotherm models were used for studying the adsorption equilibrium data. Adsorption data were fitted better with Freundlich isotherm, with a maximum monolayer adsorption capacity (q max) of 285.71 mg/g for Langmuir isotherm. The pseudo-first-order and pseudo-second-order equations were used for explaining the adsorption kinetics. The results were found to follow the pseudo-second-order model with correlation coefficients (R2) equal to 0.999. ASAC was shown to be a good adsorbent for removing residual chlorine from aqueous solutions at 25°C.

تم فحص الكربون المنشط المحضر من قشرة نوى المشمش لإزالة الكلور المتبقي في محلول مائي من خلال عملية الامتزاز. تم تقدير تأثيرات درجة الحموضة المحلول، وقت التحريض، والتركيزات الأولية. وأظهرت النتائج أن الامتزاز ازداد مع زيادة وقت الاتصال وانخفض مع زياده‌ التركيز الاولية للمحلول، في حين كان الامتزاز العالي عند الرقم الهيدروجيني = 2. استخدمت نماذج لانكماير و فريوندليتش و تمكين إيزوثرم لدراسة بيانات توازن الامتزاز. تم تركيب بيانات الامتزاز بشكل أفضل مع إيزوثرم فريوندليتش و أقصى أحادية الطبقة الامتزاز بسعة (qmax) تصل 285.71 ملغم / غم لإيزوثرم لانكماير. تم استخدام المعادلات الكاذبة من الدرجة الأولى و الكاذبة من الدرجة الثانية لشرح حركية الامتزاز. من النتائج الحاصلة تتبع النموذج الثاني شبه الكاذبة مع معاملات الارتباط (R2) تساوي 0.999. وأظهرت الممتزة قدرة عالية لإزالة الكلور المتبقي من المحاليل المائية في 25 درجة مئوية.

Listing 1 - 3 of 3
Sort by
Narrow your search

Resource type

article (3)


Language

Arabic and English (1)

English (1)


Year
From To Submit

2018 (1)

2014 (1)

2011 (1)