research centers


Search results: Found 2

Listing 1 - 2 of 2
Sort by

Article
Stability Index of the Treated Water from Al-Karkh and Al-Rasheed Water Treatment Plants in Baghdad City

Authors: Mohammed Abdul- Khalek --- Awatif Soaded Alsaqqar
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2009 Volume: 15 Issue: 2 Pages: 3606-3619
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

An analysis was performed on the treated water from two water treatment plants in Baghdad city. This analysis was used to evaluate the stability of the treated water from these plants and that will flow in the distribution system to consider its corrosivity. The variation in water stability with time and distance from the north to the south of Baghdad was indicated. The analysis showed that the flowing water in the distribution system in Baghdad is corrosive to very corrosive water by calculating Ryznar stability index (RI). In Al- Karkh WTP in the north, RI maximum ranged between 7.958 to 9.403 where RI minimum ranged between 7.03 to 7.915. Where in the south Al-Rasheed WTP, RI maximum ranged between 7.119 to 8.63 and RI minimum ranged 6.679 to 7.994. The corrositivity of water decreased in the water flowing down stream. The water quality parameters affecting RI was discussed which were calcium, alkalinity, total dissolved solids and pH.

في هذا البحث تم تحليل الماء من محطتين لتنقية المياه في مدينة بغداد. والهدف من هذا التحليل هو لايجاد استقرارية هذه المياه التي تجري داخل شبكة توزيع الماء و معرفة مدى تآكلها. وقد بين البحث مدى تغير هذه الاستقرارية مع الزمن و المسافه بين شمال و جنوب مدينة بغداد. تبين من التحليل بأن المياه الخارجة من محطات التنقية و التي تجري في شبكة التوزيع لمدينة بغداد ذات صفة تآكلية وذلك من حساب معامل الاستقرارية. في محطة الكرخ لتنقية الماء في شمال مدينة بغداد تراوح معامل الاستقرارية الاعظم بين 7.956- 9.403 و معامل الاستقرارية الادنى 7.915 - 7.03 وفي جنوب بغداد محطة الرشيد لتنقية المياه كان معامل الاستقرارية الاعظم للماء المعالج 7.119 - 8.63 و تراوح معامل الاستقرارية الادنى بين 6.679-7.994 ومن هذه النتائج نلاحظ بان تآكلية الماء تقل بأتجاه الجريان من الشمال الى جنوب من مدينة بغداد اعتمادا على صفات الماء التي تؤثر على معامل الاستقرارية . ومن هذه الصفات والتي تمت مناقشتها تركيز الكالسيوم, القاعديه, الاملاح الكليه الذائبه و درجة الحامضيه .


Article
Investigation of the Corrosion and Scaling Potentials of Raw and Treated Water and Its Effect on Concrete Tanks at Al-Tayyaraa Water Treatment Plant

Authors: Layla Abdulkareem Mokif --- Zainab Hashim Abbas --- Noor Alaa Abdulhusain
Journal: Journal of University of Babylon مجلة جامعة بابل ISSN: 19920652 23128135 Year: 2018 Volume: 26 Issue: 2 Pages: 135-140
Publisher: Babylon University جامعة بابل

Loading...
Loading...
Abstract

This study is conducted to evaluate corrosion and scaling potentials of raw and treated water at Al-Tayyaraa water treatment plant during a period of twelve months, starting from January to December 2016. Three indices of corrosion and scaling in this study are considered including Ryznar Index (RI), Langelier Saturation Index (LSI), and Aggressive Index (AI). Water quality parameters pH, Alk, (Ca), temperature, calcium as CaCO3, and (TDS) are measured. For raw water, the values of LSI and RI are (0.14-0.504) and (6.956 -7.62), respectively, whereas for treated water, the values of LSI and RI are (0.03-0.4) and (7.02-7.7), respectively. The values of AI are (11.77-12) for raw water and (11.67-11.948) for treated water. The calculated values of Langelier Saturation Index (LSI) reveal that the treated and raw water are balanced to some faint coating (light scale forming). The values of RI point that the raw and treated water are corrosive and values of aggressive index show that the water is moderate corrosion and no obvious effect on concrete tank at water treatment plants.

تم إجراء هذه الدراسة لتقييم الامكانيات التآكلية وتكوين التكلس للمياه الخام والمعالجة في محطة الطيارة لمعالجة المياه خلال فترة اثني عشر شهرا بدءا من يناير حتى ديسمبر 2016. تم النظر في ثلاثة مؤشرات للتآكل والقياس في هذه الدراسة بما في ذلك مؤشر ريزنار (Ryznar Index (RI)) ومؤشر لانجيلير للتشبع (Langelier Saturation Index (LSI)) والمؤشر العدواني (Aggressive Index (AI)). في هذا البحث تم قياس معاملات جودة المياه pH، Alk (Ca) ، درجة الحرارة، الكالسيوم متمثلا ﺒ (CaCO3)، و أخيرا المعامل TDS. واظهرت النتائج للمياه الخام ان قيم LSI و RI كانت على التوالي (0.14-0.504) و (0.03-0.4) في حين كانت نتائج نفس المؤشرين للمياه المعالجة هي (6.956 -7.62) و (7.02-7.7) على التوالي. وكانت نتائج المؤشر AI للمياه الخام والمياه المعالجة هي (11.77-12) و (11.67-11.948 ) على التوالي. وكشفت القيم المحسوبة للمؤشر LSI أن المياه المعالجة والماء الخام كانت متوازنة أو ممكن تكون طبقة رقيقة جدا من الترسبات. أشارت قيم المؤشر RI إلى أن المياه الخام والمعالجة كانت مسببة للتآكل وأظهرت قيم المؤشر العدواني (AI) أن الماء كان مسببا لتآكل معتدل وليس له تأثير واضح على الخزان الخرساني في محطات معالجة المياه.

Listing 1 - 2 of 2
Sort by
Narrow your search

Resource type

article (2)


Language

English (2)


Year
From To Submit

2018 (1)

2009 (1)