Design and Analysis of New Prosthetic Foot.
تصميم و تحليل قدم اصطناعي جديد للمبتورة اطرافهم

Loading...
Loading...
Abstract

There is a variety of artificial foot designs variable for use with prosthetic legs . Most of the design can be divided into two classes, articulated and non-articulated feet. one common non-articulated foot is the SACH . The solid ankle cushion heel foot referred to as the SACH foot has a rigid keelOne key or the key factor in designing a new prosthesis is in the analysis of a patients response This view is the most important because if the foot does not provide functional , practical or cosmetically acceptable characteristics the patient will not feel comfortable with the prosthesis , therefore design and manufacturing a new foot is essential, this foot made from polyethylene, its different shape and characteristics The characteristics deemed important by patients in achieving natural gait motion include:

Dorsiflexion
Energy return
Fatigue test In this study, including all these characteristics test, design fatigue foot tester according to ISO 10328 and design new foot .Also, the testometric crosshead was modified to find dorsiflexion angle and energy return .The fatigue criteria for polymer was proposed, in mathematical solution. Finally , the characteristics of SACH foot was compared with new foot by mathematical solution and used visual basic program and experimental method by different tests. From these test that the new foot is better than SACH foot for all test .

هناك تصاميم عديدة للأقدام الاصطناعية للمبتورة أطرافهم السفلى . وغالبا ما تصنف تلك التصاميم الى نوعين منها الاقدام المحورية التحرك و الاقدام الثابتة المفصل و احدى تلك الانواع القدم الشائع الاستخدام و الذي يدعى بـ (SACH) وهو ثابت الكاحل يحتوي على و سادة في منطقة الكعب مصنعة من رغوة المطاط اما الرسخ فيصنع من الخشب الصلب و يكون قصيرا . تعتبر استجابة المبتور طرفه من المفاتيح الاساسية في تصميم الاقدام الاصطناعية حيث من المفروض ان يشعر المريض براحة تامة في استخدام القدم من ناحية الشكل و الاداء لذا صممنا قدم جديد من مادة البولي اثلين تختلف من حيث الشكل و الخصائص عن القدم السابقة . ان من اهم الخصائص التي يجب ان تتوفر في القدم و التي يمكن ان تضمن الحركة الطبيعة للمريض :•مقدرة القدم على الانحناء بصورة طبيعية.•طاقة الارجاع•مقاومتها لفشل الكلل في هذه الدراسة صممنا جهاز لفحص فشل القدم تحت حمل الكلل لمعرفة العمر التشيغلي لاي قدم و ذلك حسب المقياس العالمي ISO 10328 , كما قمنا بتصميم طرف اصطناعي و اجرينا عليه اختبارات مختلفة منها حساب العمر التشيغيلي, قياس زاوية الانحناء للقدم و حساب طاقة الارجاع بعد ان ابدلنا الفك السفلي لجهاز الشد و اجرينا اختبار الكلل لمادة البولي اثليين لايجاد مخطط الاجهاد – العمر , رياضيا اوجدنا صيغة جديدة لفشل الكلل في البوليمرات و من ثم تم بناء برنامج فيجوال بيسك .في النهاية اجرينا مقارنة بين خصائص القدم الجديدة و القدم السابقة (SACH ) كما اجرينا مقارنة بين الجزء العملي و الجزء النظري و تبين ان القدم الجديدة كانت افضل بكل المعايير من القدم السابقة.


Article
Study and Analysis of Failure Mechanism of Bolt Adapter in Prosthetic SACH Foot
دراسة و تحليل الية الفشل لبرغي الطرف الاصطناعية نوع SACH

Authors: Muhsin J. Jweeg --- Kadhim K. Resan --- Ali Abdulameer Najm
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2014 Volume: 32 Issue: 6 Part (A) Engineering Pages: 1442-1457
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

This paper presents is the study and analysis of failure mechanism of non-articular prosthetic foot (SACH) in the region (Bolt Adapter). The tests of mechanical properties and fatigue behavior were carried for material of which the bolt manufacture from it is a region where the failure occurs out and inserted of these properties to the program of engineering analysis (Ansys) to calculate the safety factor of fatigue and stress equivalent (Von-Mises).The results that both, showed the maximum equivalent stress and the minimum safety factor of fatigue are located in bolt at interface region between the adapter and the foot at notch, however, in static case, the effect was on the ground reaction force at toe off phase more than heel strike phase.

في هذا البحث يتم دراسة و تحليل الية الفشل في الطرف الاصطناعي غير مفصلي (SACH) في منطقة البرغي,اجريتاختبارات الخواص الميكانيكية و الكلال للمادة المصنع منها البرغي,وهي المنطقة التي يحدث فيها الفشل و ادخال هذه الخواص لبرنامج التحليل الهندسي(Ansys) لحساب عامل الامان للكلال و الاجهاد المكافئ (Von-Mises). النتائج اظهرت ان اعظم اجهاد مكافئ و اقل عامل امان للكلال ظهر في منطقة البرغي عن المنطقة الفاصلة بين Adapter و القدم عند السن و في حالة السكون,كان تاثير رد فعل الارض عن طورtoe off اكبر مما علية عند طورheel strike.

Keywords

SACH --- prosthetic --- foot --- bolt --- adapter --- failure --- mechanism --- analysis


Article
Improving Fatigue Life of Bolt Adapter of Prosthetic SACH Foot
تحسين عمر الكلل للولب القدم الصناعية نوع SACH

Authors: Muhsin J. Jweeg محسن جبر جويج --- Kadhim K. Resan كاظم كامل رسن --- Ali Abdulameer Najm علي عبد الامير نجم
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2014 Volume: 20 Issue: 3 Pages: 62-71
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

In this research an analysis for improving the fatigue behavior (safety factor of fatigue) of non-articular prosthetic foot (SACH) in the region (Bolt Adapter).The laser peening was carried to the fatigue specimens to improving the fatigue properties of bolt’s material. The tests of mechanical properties and fatigue behavior were carried for material that the bolt manufacture from it, a region where the failure occur and inserted of these properties to the program of engineering analysis (Ansys) to calculate the safety factor of fatigue. The results showed that the safety factor after hardening by laser is increased by 42.8%.

في هذا البحث تم تحليل و تحسين سلوك الكلال (عامل الامان للكلال) للقدم الاصطناعية غير مفصلي (SACH) في منطقة الالولب.عملية التصليد بالليزر قد اجريت لعينات الكلال لتحسين خواص الكلال لمادة الالولب.اختبارات الخواص الميكانيكيه و سلوك الكلال اجريت لمادة التي صنع منها الالولب,المنطقة التي يحصل بها الفشل و ادخال هذه الخواص لبرنامج التحليل الهندسي (SACH) لحساب عامل الامان للكلال.النتائج اظهرت ان عمر الكلال بعد التصليد بواسطة الليزر قد ازداد بنسبة 42.8%.