Damping of Power System Oscillations by Using Coordinated Control of PSS and STATCOM Devices
اخماد تذبذبات منظومة القدرة بتنسيق السيطرة PSS وجهاز STATCOM

Authors: Rashid H. Al- Rubayi --- Inaam Ibrahim Ali
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2010 Volume: 28 Issue: 23 Pages: 6814-6830
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

The main objective of this paper is to investigate the power system stability enhancement via coordinated control of PSS and static synchronous compensator (STATCOM) based controllers. Also, investigate the effectiveness and dynamic interaction of STATCOM controllers in damping system oscillation. Proposed optimal pole shifting technique to design damping controller of excitation system (PSS) and STATCOM basedcontroller. The method is based on modern control theory for multi-input and multi-output system. Several control schemes are proposed. The effectiveness of the proposed control schemes in improving the power system is verified through eigenvalues and time domain simulations under nominal loading conditions. The analysis of cases under study show that, the STATCOM – based controller has good effect on improving system damping and the coordinated control of PSS and STATCOM – based controller provide the best means forstabilizing power system, more damping with less control effort than individual control


Article
Enhancement of a Power System Transient Stability Using Static Synchronous Compensator STATCOM
تعزیز الاستقراریة العابرة لنظام القدرة بأستخدام المعوض التزامني الثابت

Authors: Naseer M. Yasin --- Mustafa M. Al-Eedany
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2013 Volume: 31 Issue: 15 Part (A) Engineering Pages: 2805-2815
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

In modern power system utilities, increased power demand often lead to thesituation where the system no longer remains in secure operating region. Flexible ACTransmission Systems (FACTS) controllers can play an important roll in powersystem security enhancement. The goal of FACTS devices study is to measure theirimpact on the state of the electrical networks into which they are introduced. Theirprincipal function is to improve the static and dynamic properties of the electricalnetworks and that by increasing the margins of static and dynamic stability. In thispaper the modeling of Static Synchronous Compensator (STATCOM) withinNewton-Raphson power flow equations has been presented, discussed, implementedand the transient stability of a power system was tested when three phase fault isapplied at a certain branch of the power system. Case studies are carried out on a 5-bus and a 30-bus test systems to demonstrate the effectiveness of the proposed model.


Article
Stability Improvement Of the (400kV) Iraqi Grid using the best FACTS Devices
تحسين إستقرارية منظومة الشبكة العراقية (KV 400) بأستعمال افضل جهاز من اجهزة ال FACTS))

Authors: Rashid H. Al-Rubayi --- Shaimaa Sh. Abd Alhalim
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2015 Volume: 33 Issue: 7 Part (A) Engineering Pages: 1598-1618
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

Electrical power system has become large and complicated, so it is subjected to sudden changes in load levels. Stability is an important concept which determines the stable operation of the power system.The modern trend is to employ by installing Flexible Alternating Current Transmission System (FACTS) devices in the system for effective utilization of transmission resources.The FACTS devices contribute to the power flow improvement besides, they extend their services in transient stability improvement as well, study and analyze the stability of the system through rotor angle and voltage .The object of this work is to improve the stability of the Iraqi National Super Grid System (INSGS) by using optimal FACTS devices in different optimal locations under fault conditions.Two test systems are studied, the first system is IEEE or WSCC (9-bus bars), and the second system is the Iraqi (400 KV) electrical network 24-bus bars.The load flow program was implemented using the Newton-Raphson method and the numerical solutions of non-linear differential equations are solved using Trapezoidal method.A comparison has been made between five types of FACTS (UPFC, SSSC, TCSC, SVC, STATCOM) at optimal location of the Iraqi grid and (9-bus bars) to get optimal FACTS devices by (voltage stability, rotor angle ).The results obtained showed that the installation of Unified Power Flow Controller (UPFC) is optimal devices for an improvement of the stability by damping the voltage and rotor angle oscillations.

يعتبر نظام القدره الكهربائيه من الانظمه الضخمه والمعقده لاحتوائها على عدد كبير من محطات التوليد وخطوط النقل وأجهزة السيطرة لذلك فانه يخضع الى تغيرات مفاجئه في مستويات الحمل ، حيث اصبح من الصعب جداً الحفاظ على نظام مستقرمع التغيرات التي يشهدها النظام, لذلك فمن المهم جداً تحسين أستقرارية منظومة القدرة.التطور الحديث في نظام القدره الكهربائيه هو عن طريق تنصيب اجهزة ال(FACTS ) في اماكن مثاليه مختلفه حيث تساهم هذه الاجهزه الكهربائيه في تحسين تدفق القدره الكهربائيه الى جانب تحسين الاستقرارية العابره عن طريق الفولتية وزاوية الدوار الغرض من هذا العمل هو تحسين استقرارية منظومة القدرة للشبكة العراقية عن طريق استخدام افضل جهاز للـ(FACTS) ونصب هذه الاجهزه في اماكن مثاليه مختلفة تحت ظرف الخطأ تم دراسة منظومتان, المنظومة الأولى هي(IEEE or WSCC ) المكونة من (9) عقدة والمنظومة الثانية هي الشبكة الوطنية العراقية( 400 KV) المكونه من (24) عقدة ,في المنظومتان تم اختبار عطل ثلاثي الأطوار عند مواقع مختلفة و حالات مختلفة (عطل وقتي, عطل دائم) . تم في هذا البحث دراسة وتكوين برنامج لسريان الحمل(Load Flow) باستخدام طريقة (Newton-Raphson) وتم حل المعادلات التفاضلية الغير خــطـيــــة باســتــخــدام الطـرق العــدديــــــة وذلـك باســتــخــدامطــريـقــة (Trapezoidal) . البرامج المستخدمة في هذا البحث تم تطبـيـقــهــا باستخدام برنامج MATLAB (7.11.0.584 ) اصدار(R2010b) المبني على اساس برامجيات (PSAT version 2.1.6)( 2002-2010 (©. في هذا البحث تم المقارنه بين خمسة انواع من ال FACTS)) هي UPFC, SSSC, TCSC, SVC, STATCOM)) وتنصيبها في اماكن مثالية ومختلفه في الشبكه الوطنيه العراقية ومنظومة (9) عقدة للحصول على جهاز مثالي لتحسين القدره المنقوله والمقارنة تمت عن طريق الفولتية وزاوية الدوار.

Keywords

FACTS --- UPFC --- SSSC --- STATCOM --- TCSC --- SVC --- PSAT


Article
THD Reduction Using Series Transformer Connection In A STATCOM Within Mosul Ring System
تقليل المحتوى الكلي للتشوه باستخدام ربط التوالي للمحولة في المعوض التزامني الساكن ضمن النظام الحلقي لمدينة الموصل

Authors: Yasser A. Mahmood ياسر احمد محمود --- Majed S. Al-Hafid ماجد صالح الحافظ --- Dhaiya A. Al-Nimma ضياء علي النعمة
Journal: AL Rafdain Engineering Journal مجلة هندسة الرافدين ISSN: 18130526 Year: 2009 Volume: 17 Issue: 5 Pages: 15-22
Publisher: Mosul University جامعة الموصل

Loading...
Loading...
Abstract

AbstractThe static synchronous compensator (STATCOM) is one of the components of Flexible AC Transmission System (FACT). STATCOM is used to compensate the reactive power with fast response. It consist of power electronic devices. The main drawback of STATCOM is harmonics injection to the system. Different techniques can be used to reduce harmonic injection, such as the use of 12-pulse STATCOM with Pulse Width Modulation (PWM) to control the operation of power electronic devices. In this work the series connection of transformers is studied and compared with parallel connection. The study is applied to the suggested STATCOM in the ring system around Mosul city. Matlab / Simulink is used to analyze the two systems. The results are given and discussed in the paper. Also it is found that the Total Harmonic Distortion (THD) can be further reduced by using series connection of transformers secondary rather than shunt connection. Keywords :STATCOM, Harmonic reduction, Transformer connection in STATCOM, Mosul distribution ring.

يعد المعوض التزامني الساكن (STATCOM) احد مكونات نظام النقل المتناوب المرن (FACT). حيث يستخدم المعوض التزامني الساكن لتعويض القدرة المتفاعلة باستجابة سريعة. ويتكون من نبائط الكترونيات القدرة. ويمثل توليد مجموعة من التوافقيات في الشبكة عائقا رئيسيا عند استخدامه. وهناك تقنيات مختلفة تعمل إلى تقليل هذه التوافقيات كثيرا منها استخدام المعوض ذو 12 نبضة وفق تقنية تضمين عرض النبضة (PWM). تم في هذا البحث دراسة استخدام ربط التوالي للمحولة في المعوض التزامني الساكن ومقارنته مع ربط التوازي. طبق التحليل على المعوض المتزامن المقترح للنظام الحلقي لمدينة الموصل. وتم تحليل الشبكة باستخدام برنامج Matlab / Simulink مع عرض ومناقشة النتائج. ولوحظ ان استخدام ربط التوالي لثانوي تلك المحولات يقلل كثيرا من المحتوى الكلي للتشوه (THD) مقارنة مع ربط التوازي.


Article
STATCOM Application in 400kv Iraqi Super Grid for Voltage Magnitude Improvement
تطبيق STATCOM في شبكةالضغط الفائق العراقية Kv(400) لتحسين قيمة الفولتية

Author: Shatha S. Abdulla Al-Kubragyi شذى صحبت عبدالله الكبراغي
Journal: Al-Qadisiyah Journal for Engineering Sciences مجلة القادسية للعلوم الهندسية ISSN: 19984456 Year: 2014 Volume: 7 Issue: 3 Pages: 290-305
Publisher: Al-Qadisiyah University جامعة القادسية

Loading...
Loading...
Abstract

This paper presents a study of static synchronous compensator (STATCOM). One of the Flexible AC Transmission System (FACTS) devices, it can significantly improve power systems stability. Consisting of voltage sourced converters connected to an energy storage device on one side and to the power system on the other, it specifically can provide reactive support to buses.This work presents a simple algorithm for identifying weak buses to determine the best location for STATCOM. Singularity of the power flow Jacobian matrix as an indicator of steady-state stability has used, the sign of the determinant of the load flow Jacobian was used to determine the system stability, by computing eigenvalues, eigenvectors , minimum singular value of load-flow Jacobian Matrix and sensitivity analysis between power flow and bus voltage changes. Load flow analysis of the Iraqi grid 400 KV network has been carried out using Newton- Rephson Method with and without STATCOM. The result of Load flow analysis show improvement in bus voltage with the use of STATCOM in the system.

في هذا البحث تم دراسة ثابت المعوض المتزامن (STATCOM). واحد من أجهزة نظام نقل التيار المتردد المرنة ،حيث يمكن أن يحسن إلى حد كبير استقرار أنظمة الطاقة. يتكون من محولات مصادر الجهد متصلة إلى جهاز تخزين الطاقة على جانب واحد ونظام الطاقة من جهة أخرى، فإنه على وجه التحديد يمكن أن توفر دعم لل bus بالقدرة التفاعلية.في هذا العمل تم الاعتماد على خوارزمية بسيطة لتحديد buses الضعيفة لتحديد أفضل موقع لSTATCOM، استخدمت singularity لمصفوفة جاكوبين لتدفق الطاقة كمؤشر على استقرارية النظام ،حيث تم اعتماد أشارة المحدد لمصفوفة جاكوبين لتدفق الحمل لتحديد استقرار النظام، من خلال حساب القيم الذاتية (eigenvalue)، المتجهات الذاتية (eigenvectors) ، وminimum singular value لمصفوفة جاكوبين لسريان الحمل وتحليل الاستجابة بين تدفق الطاقة وتغيرات مجمع الجهد.تم تحليل سريان الحمل للشبكة العراقية ٤٠٠ كف باستخدام طريقة نيوتن رافسن مع وبدون STATCOM. ونتائج التحليل أظهرت تحسنا في مجمع الجهد ((bus voltage بأستخدام STATCOM في النظام.


Article
VOLTAGE STABILITY IMPROVEMENTS USING ADAPTIVE CONTROLLER FOR STATCOM
تعزيز أستقرارية الفولتية باستخدام المسيطر التكيفي للمعوض التزامني الساكن

Authors: Ayad A. AL-Gailany --- Inaam I. Ali --- Abdelelah K. Mahmood
Journal: Journal of Engineering and Sustainable Development مجلة الهندسة والتنمية المستدامة ISSN: 25200917 Year: 2017 Volume: 21 Issue: 2 Pages: 129-148
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

: In this work, A STATCOM of 12-pulse two levels is used to regulate the bus voltage at specific bus bar under many cases of abnormal conditions like load and source disturbances. The proposed system consists of a single machine, transmission line and load. The compensation process are performed and compared between the two suggested control methods, first, the conventional control by using PI controller only which is used to improve the voltage profile. Second, the adapting controller uses self-tuning fuzzy PI controller for improving the voltage profile. At the time of disturbance gets occurrence, the PI controller must change its parameters to recover the voltage profile into the stable state at the disturbance moment. The simulation results show the improvements of voltage profile for both two types and then compare them. The improvement of voltage profile using adaptation method is less over shoot and attains a steady state faster than the conventional PI when the system is subjected under many disturbances. The results of the harmonic effect show low values of total harmonic distortion (THD) of supply voltage and current. Moreover, it is acceptable with IEEE standards because a new technique of Sinusoidal Pulse Width Modulation (SPWM) is used.

تم في هذا البحث استخدام معوض تزامني ساكن (STATCOM ) ذو 12 نبضة ثنائي المستوى وذلك لتنظيم الفولتية عند احد القضبان العمومية في الحالات الغير طبيعية كما في اضطراب الحمل واضطراب المصدر. يتكون نظام القدرة المقترح من مولد واحد وخط نقل و حمل. تتم عملية التعويض والمقارنة بين طريقتين مقترحتين للسيطرة, الاولى, باستخدام السيطرة التقليدية عن طريق استخدام المسيطر (التناسبي- التكاملي) لتحسين الفولتية, الثانية, بأستخدام السيطرة التكيفية ذاتية التنغيم بواسطة المنطق المضبب لتحسين الفولتية. في لحظة حصول الاضطراب يحتاج المسيطر (التناسبي- التكاملي) الى تغيير في معاملاته وذلك لتحسين وتنظيم فولتية العمومي وارجاعها الى قيمتها المستقرة. بينت نتائج التمثيل تحسن في قيمة الفولتية لكلا الحالتين و بالمقارنة بينهم. تعزيز استقرارية الفولتية بأستخدام طريقة التكييف يكول اقل تجاوز للحد ويصل للحالة المستقرة اسرع من الطريقة التقليدية باستخدام المسيطر(التناسبي –التكاملي) . النتائج المستحصله من تأثير التوافقيات اظهرت قيم قليلة لنسبة تشوه التوافقيات الكلي (THD%) للفولتية والتيار بالاضافة الى مقبوليتها ضمن معايير IEEE وذلك بسبب استخدام تقنية تعديل عرض النبضة الجيبي (SPWM ).


Article
Optimal Location and Parameter Setting of STATCOM Device Based PSO for Iraqi Grid Voltage Profile Enhancement and Power Losses Minimizing

Authors: Rashid H. Al-Rubayi --- Mohammed B. Eesee
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2019 Volume: 37 Issue: 2 Part (A) Engineering Pages: 60-69
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

The main goal of this work is to enhance the Voltage stability by usingoptimum location and parameters setting of STATCOM device. The parametersare the magnitude of the output voltage ��� and the angle ���, these parametersare taken to control the device performance. The simulation results have beendone by using power flow program solution by Newton-Raphson method (Matlabprogram / M-file) with Particle Swarm Optimization (PSO) technique, for powerlosses minimizing and improving voltage profile. Two systems have beenimplemented:- IEEE 5-bus test system and Iraqi (400 kV) National super GridSystem 27-bus. The MATLAB programs are Applied in the first step on IEEE 5-bus test system to examine the performance of the programs by comparing theresults with other references, then it is implemented on Iraqi (400 kV) Nationalsuper Grid System to find optimum location and parameter setting of STATCOMdevice. The results show that, the STATCOM has significant effect on improvingthe voltage profile and reducing apparent power losses, The STATCOM deviceperformance depends on its location and parameter settings, and The PSOalgorithm can easily find out the optimal location and parameters setting ofthe STATCOM for which the voltage deviation are minimum.


Article
Design and Simulation of the Flexible AC Transmission System (FACTS) with Power Oscillation Damping (POD)
تصميم ومحاكاة لنظام نقل التيار المتناوب المرن مع مخمد التذبذب بالقدرة

Authors: Raaed Faleh Hassan --- Ahmed Wahab Abdul Razzaq
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2012 Volume: 30 Issue: 9 Pages: 1428-1445
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

In electrical power systems there are many problems, from these problems voltage drop, over voltage and instability. These problems are solved by using FACTS technology. Flexible AC transmission system (FACTS) can provides better control than conventional control and achieves fast control time response; therefore FACTS controllers play an important role in power system stability enhancement. STATCOMis a shunt FACTS device which is used for voltage controlling and increasing the performance of the system. In this paper STATCOM is used to improve voltage magnitude and stability of electrical network by using MATLAB/SIMULINK. To show its effectiveness a prototype of electrical network has been chosen which consists of five buses, three generators and four loads. Simulation results show a robust improvement in network with STATCOM. If a three phase to ground fault occursbetween buses (3&4) there are oscillations after clearing fault. To reduce these oscillations power oscillations damping (POD) has been proposed with STATCOM. Simulation results show that an enhancement of the network prototype with proposed controller (STATCOM- POD).

في انظمة القدرة الكهربائية توجد العديد من المشاكل منها مشاكل زيادة او نقصان الفولتية وعدم استقراريتها. لغرض حل هذه المشاكل تستخدم تقنية نظام نقل التيار المتناوب المرن الذي يمكن ان يجهز سيطرة افضل من السيطرة التقليدية ويحرز تحكم سريع بزمن الاستجابة. لذلك هذه التقنية تلعبدور مهم في زيادة استقرارية نظام القدرة. احدى هذه التقنيات المعوض التزامني الستاتيكي الذي يستخدم للسيطرة على الفولطية وزيادة جودة اداء النظام. في هذا البحث المعوض التزامني الستاتيكي يستخدم لتحسين قيمة الفولطية واسقرارية الشبكة الكهربائية بأستخدام برنامج الماتلاب. لغرضملاحظة تأثير هذا المسيطر يتم ربطه لنموذج شبكة كهربائية. هذه الشبكة تتكون من خمس قضبان توصيل و ثلاث مولدات و اربعة احمال. نتائج برنامج الماتلاب توضح تحسن كبير لاداء الشبكة مع ربط المسيطر. في حالة ظهور عطل من نوع (ثلاثي الطور ارضي وهو اقوى انواع الاعطال) بين قضيب التوصيل الثالث والرابع من الشبكة الكهربائية تنتج ذبذبات بعد زوال العطل. هذه الذبذباتتقل عن طريق استخدام مخمد ذبذبات القدرة مع المعوض التزامني الستاتيكي كمسيطر مقترح. نتائج برنامج الماتلاب توضح تحسين عمل الشبكة بعد زوال العطل باستخدام المسيطر المقترح.


Article
STATCOM Application on the Iraqi (400kv) Super Grid Network with Power Oscillation Damping(POD) & Proportional Integral (PI) Controller
تطبیق المعوض المتزامن الستاتیكي على الشبكة العراقیة الوطنیة مع مخمد ذبذبات القدرة و المسیطر التناسبي التكاملي

Authors: Raaed Faleh Hassan --- Ahmed Wahab Abdul Razzaq
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2012 Volume: 30 Issue: 10 Pages: 1816-1842
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

Flexible ac transmission system (FACTS) can provide control more thanconventional control and achieve fast control response time, STATCOM is a shuntFACTS device it is used to voltage control and increase the performance of the system.In this paper STATCOM is used to improve the voltage magnitude and stability for theIraqi (400KV) super grid network byusing MATLAB/SIMULINK. STATCOM isconnected to Iraqi (400kv) super gridnetworkwhich is consisting of twenty four buses,eleven generators, eleven step up transformers fromeach generator side, twenty stepdown transformers from each load side and twenty loads.The loads variation throughthe seasons of the year causesdrop voltage on the buses of the network.To return thevoltage to the rated value (400kv) STATCOM is used for this purpose. STATCOMprovides suitable reactive power to the network to compensate the drop voltage on thebuses, in the same time when the STATCOM improves the voltage there are largeoscillations. These oscillations are handled by using power oscillation damping (POD)and proportional integral (PI) controller with the STATCOM.Each of thepoweroscillation damping (POD) and Proportional integral (PI) controller is connected insidecurrent regulator of the STATCOM device.The performance of the (POD) and (PI) incancelation the oscillations is compared.

نظام نقل التیار المتناوب المرن یمكن ان یجھز سیطلرة افضل من السیطرة التقلیدیة ویحرزسرعة تحكم بزمن الاستجابة. المعوض المتزامن الستاتیكي جھاز تحویل نظام نقل التیار المتناوبالمرن انھ یستخدم للسیطرة على الفولطیة وزیادة اداء النظام. في ھذا البحث المعوض المتزامنالستاتیكي یستخدم لتحسین قیمة واستقراریة الشبكة الوطنیة العراقیة (جانب الاربعمائة كیلو فولت)بأستخدام سمنلك برنامج الماتلاب. المعوض الستایكي المتزامن یربط الى الشبكة الوطنیة العراقیة جانب(الاربعمائة كیلو فولت) التي تتكون من اربعة وعشرون قضیب توصیل, احد عشر مولد, احد عشرمحولة رافعة للفولطیة من جھة كل مولد, عشرون محولة خافضة للفولطیة من جھة كل حمل و عشرونحمل.تغیر الاحمال خلال فصول السنة تسبب سحب الفولطیة على قضبان توصیل الشكبة. لارجاعالفولطیة الى القیمة التقدیریة اربعمائة كیلو فولط المعوض الستاتیكي المتزامن یستخدم لھذا الغرض.المعوض الستاتیكي المتزامن یجھز قدرة متفاعلة مناسبة الى الشبكة لتعویض سحب الفولطیة علىالقضبان, في نفس الوقت عندما المعوض الستاتیكي المتزامن یحسن الفولطیة توجد ذبذبات كبیرة. ھذهالذبذبات تعالج بأستخدام مخمد ذبذبات القدرة و مسیطر نوع تناسب تكامل الربح مع المعوضالستاتیكيالمتزامن. كل من مخمد ذبذبات القدرة و مسیطر نوع تناسب تكامل الربح یربط داخل منظم التیار منجھاز المعوض الستاتیكي المتزامن. اداء مخمد ذبذبات القدرة و مسیطر نوع تناسب تكامل الربح فيازالة او تقلیل الذبذبات یقارن.


Article
Unified P-Q based STATCOM Control for Wind Driven Induction Generator

Authors: Ahmed A. A. Hafez --- R. M. Al-Bouthig --- J. I. AL-Sadey
Journal: Iraqi Journal for Electrical And Electronic Engineering المجلة العراقية للهندسة الكهربائية والالكترونية ISSN: 18145892 Year: 2015 Volume: 11 Issue: 1 Pages: 10-17
Publisher: Basrah University جامعة البصرة

Loading...
Loading...
Abstract

This paper principally advises a simple and reliable control for Static Synchronous Compensator(STATCOM) in a stand-alone wind driven self-excited induction generator power system. The control was proposedbased on instantaneous P-Q theory. The advised control enjoys the merits of robustness, reliability and simplicity.The paper also proposes a dimensioning procedure for the STATCOM that involves advising an annotativeanalytical expression for sizing the DC-link capacitor. This procedure has the advantages of applicability fordifferent reactive power compensators that depend on a separate DC-link in its operation. Comprehensive simulationresults in Matlab environment were illustrated for corroborating the performance of the advised control underrigorous operating scenarios. The results show the feasibility, reliability and practicability of the proposedcontroller.