research centers


Search results: Found 6

Listing 1 - 6 of 6
Sort by

Article
Entropy Method as Criteria for Analysis of a Steam Power Plant

Author: Moayed Razoki Hasan
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2007 Volume: 13 Issue: 3 Pages: 1818-1833
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

In this paper a theoretical analysis of South Baghdad and Dura power plant is carried out according to second law of thermodynamic depending on entropy (irreversibility coefficient or lost work) method instead of exergy (availability) method. In the used entropy method. The power plant is divided into main blocks ( boiler, turbine, condenser, and feed water heater and pumps ). The irreversibility losses and coefficient for each block are calculated and then the overall irreversibility and thermal efficiency of the plant are calculated. The results of this work are compared with previous results, that depending on exergy method. The comparison of results show that both methods give approximately the same results since both of them rely the 2nd law of thermodynamic. Entropy method is simple and intellectually and intuitively satisfying and giving direct relationship between components losses of power plant and its overall efficiency.

يتناول البحث الحالي تحليل محطة جنوب بغداد ومحطة الدورة الحرارية باعتماد طريقة الانتروبي (معامل اللانعكاسية او الشغل المفقود) بدلا من طريقة المتاحية. في طريقة الانتروبي المستخدمة, يتم تقسيم محطة القدرة الى اجزاء رئيسية ( المرجل, التوربين, المكثف, و المسخنات و مضخات ماء التغذية ). يتم حساب معاملات و خسائر اللاانعكاسية لكل جزء ثم بعد ذلك يتم حساب اللاانعكاسية الكلية للمحطة و كفاءتها الحرارية. اظهرت مقارنة النتائج مع نتائج الاعمال السابقة لتحليل المحطتين باعتماد طريقة المتاحية. لقد اشارت النتائج بان الطريقتين تعطيان نتائج متقاربة جداً مع افضلية لطريقة الانتروبي التي تمتاز بسهولتها مع امكانية الربط المباشرلخسارات كل جزء من اجزاء المحطة مع الكفاءة الكلية للمحطة.


Article
Entropy Method as Criteria for Analysis a Steam Power Plant

Author: Moayed Razoki Hasan
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2009 Volume: 15 Issue: 3 Pages: 4025-4040
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

In this paper a theoretical analysis of South Baghdad and Dura power plant is carried out according to second law of thermodynamic depending on entropy (irreversibility coefficient or lost work) method instead of exergy (availability) method. In the used entropy method. The power plant is divided into main blocks ( boiler, turbine, condenser, and feed water heater and pumps ). The irreversibility losses and coefficient for each block are calculated and then the overall irreversibility and thermal efficiency of the plant are calculated. The results of this work are compared with previous results, that depending on exergy method. The comparison of results show that both methods give approximately the same results since both of them rely the 2nd law of thermodynamic. Entropy method is simple and intellectually and intuitively satisfying and giving direct relationship between components losses of power plant and its overall efficiency.

يتناول البحث الحالي تحليل محطة جنوب بغداد ومحطة الدورة الحرارية باعتماد طريقة الانتروبي (معامل اللانعكاسية او الشغل المفقود) بدلا من طريقة المتاحية. في طريقة الانتروبي المستخدمة, يتم تقسيم محطة القدرة الى اجزاء رئيسية (المرجل, التوربين, المكثف, و المسخنات و مضخات ماء التغذية). يتم حساب معاملات و خسائر اللاانعكاسية لكل جزء ثم بعد ذلك يتم حساب اللاانعكاسية الكلية للمحطة و كفاءتها الحرارية. اظهرت مقارنة النتائج مع نتائج الاعمال السابقة لتحليل المحطتين باعتماد طريقة المتاحية. لقد اشارت النتائج بان الطريقتين تعطيان نتائج متقاربة جداً مع افضلية لطريقة الانتروبي التي تمتاز بسهولتها مع امكانية الربط المباشر لخسارات كل جزء من اجزاء المحطة مع الكفاءة الكلية للمحطة.


Article
Utilization of exhaust waste heat from power plants for sea water desalination
تسخين حراره النفايات الغازية (العوادم)من محطات توليد الطاقة في تحلية مياة البحر

Authors: Lina Ismail Jassim لينا اسماعيل جاسم --- Ghanim Kadhem Sada غانم كاظم عبد السادة
Journal: Journal of Engineering and Sustainable Development مجلة الهندسة والتنمية المستدامة ISSN: 25200917 Year: 2009 Volume: 13 Issue: 4 Pages: 58-68
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

The international demand of water increased compared to the available water resources due torecent development water resources for different uses. In many areas especially in Arabian GulfAreas, a shortage of portable water. This study deals with design a model to combine the multi effect desalination water (MED) with the steam power plant. Using the exhaust waste heat of the power plant to heat the sea water. The model has been based upon various heat and mass transfer equations. Taking in consideration all requirements of making available safe drinking water for requirement. The waste heat of the exhaust gases of power plant is captured before exhausting it to the atmosphere and transferred to salty water. The temperature of salty water rise to level 90C to130C. This is ideal temperature for desalination in multiple effect distillation MED plant. The hot salty water then passes through a flash into the evaporator then condenses on the condenser tube bank, and internal heat recovery is achieved by transferring its heat of condensation to the sea water feed that is thus being preheated.In this study selective an exist steam power plants, combine with MED to produce 1000 m3/day to15000 m3/day drinking water from salty water.The cost of combine MED desalination with power plant was compared with the exist desalination methods, the study show that this system less cost than the other methods of desalination.The model is useful in sizing various components, power plant chimney heat exchanger, evaporation and condensation chambers of desalination plant and useful to find out plant output for various combinations of design parameters. The basic motivation for this research and development is to propose a choice of technical options, based on the use of power plant energy, which could be sustainable and at same time economically. The lowest costs with the multi effect desalination (MED) plants are obtained by utilizing virtually free waste heat of power plant.

نتيجة لشحة المياه الصالحة للشرب في منطقة الشرق الاوسط وخاصة منطقة الخليج العربي. تضمن هذا البحث تصميم نموذج لتقطير مياه البحر المالحة للحصول على ماء صالح للشرب باستخدام الحرارة المطروحة من محطات الطاقة الكهربائية لتسخين المياه المالحة، وهذا النموذج يشمل تصميم مجموعة مبادلات حرارية اللازمة لعملية التقطير تتكون المنظومة من مدخنة محطة الطاقة الكهربائية والمبخر والمقطر ومجمعين للملح والماء المقطر، علما ان هذه المنظومة تنتج ما يقارب 1000 متر مكعب الى 15000 متر مكعب ماء صالح للشرب. وتعتبر تلك طريقة اقتصادية للحصول على ماء الشرب مقارنة بتكلفة محطات تحلية المياه.


Article
A Numerical and Experimental Study of Steam Condenser Working with Modified Rankine Cycle
دراسة عددية وعملية لمكثف بخاري يعمل بدورة رانكن المعدلة

Author: Hisham Hassan Jasim
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2013 Volume: 31 Issue: 1 Part (A) Engineering Pages: 156-171
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

A Numerical and experimental study of thermal and heat transfer processes in a steam condenser operating in steam power plant with steam engine was developed to built analytical model using to predict thermal profile of condenser. Iterative technique between Engineering Equations Solver (EES) and Matlab programming was developed to find water properties .The exit water temperature, steam flow rate, geometric dimension (diameter and tube length) ,convection heat transfer coefficient of water and condenser efficiency were computed using the analytic model. Experimental results for a range of water flow rate (0.0153 to 0.0121 kg/s) with constant inlet water temperature of 25 were used to validate the analytical model. Compared with a validated model, the standard deviations of analytical model are less than 4%, and all errors fall into ±6%. Analytical model can be used to show the relation between thermal parameters.

تضمن العمل في هذا البحث دراسة عددية وعملية لكل من عمليات داينميك وانتقال الحرارة لمكثف بخاري يعمل بوحدة توليد قدرة تستخدم محرك بخاري لبناء موديل رياضي يستخدم للتنبؤ بالأداء الحراري للمكثف . اعتمد على تقنية التكرار بين (EES) و(Matlab) بداءً من قيم الإدخال الأولي للحصول على خواص الماء. يستخدم الموديل الرياضي للحصول على درجة حرارة خروج الماء ومعدل تدفق البخار و قطر وطول الأنبوب ومعامل انتقال الحرارة بالحمل لماء التبريد مع كفاءة الأداء للمكثف. وحدة توليد قدرة تم اعتمادها للحصول على النتائج المختبرية ولمدى من قيم تدفق ماء التبريد (0.0153 - 0.0121 kg/s) ودرجة حرارة ثابتة لدخول الماء ( 25) لتصديق نتائج الموديل. عند مقارنة نتائج الموديل الرياضي مع النتائج المختبرية وجدنا انحراف معياري اقل من 4% ونسب خطاء تقع ضمن حدود ±6%. يمكن استخدام الموديل الرياضي لبيان علاقة الخواص الحرارية فيما ببينها.


Article
Design of a Programmable System for Failure Modes and Effect Analysis of Steam-Power Plant Based on the Fault Tree Analysis
تصميم نظام مبرمج لتمييز أنماط الفشل وتحليل التأثيرات لمحطة بخارية لتوليد الطاقة الكهربائية اعتمادا على انشاء شجرة تحليل الخطأ

Loading...
Loading...
Abstract

In this paper, the system of the power plant has been investigated as a special type of industrial systems, which has a significant role in improving societies since the electrical energy has entered all kinds of industries, and it is considered as the artery of modern life.
The aim of this research is to construct a programming system, which could be used to identify the most important failure modes that are occur in a steam type of power plants. Also the effects and reasons of each failure mode could be analyzed through the usage of this programming system reaching to the basic events (main reasons) that causing each failure mode. The construction of this system for FMEA is depending on the logical relationships of the fault tree analysis for the systems that contained in the power station.
The designing of such system could be used as an assistance tool for the specialist user (the power engineer) in identifying of all reasons and effects for any type of failures. So this is help to fastening the repairing operation of the identified failure mode to improve the efficiency of operating system as represented by the maintainability, which is a function of system reliability. The selection of the steam type of power generation systems for the application of this study, because this type is the most common type of Iraqi power plants. While such the designed system could be programmed to be use in another types of industrial systems.

يهدف البحث الى إنشاء نظام مبرمج يمكن أن يستخدم في تمييز أنماط الفشل (العطلات) الرئيسة التي يمكن أن تحدث في محطة بخارية لتوليد الطاقة الكهربائية. كما ومن خلال استخدام هذا البرنامج يمكن تحليل التأثيرات والأسباب لكل نوع من أنواع العطلات وصولا الى ما يعرف بالأحداث الأساسية المسببة للعطل. لقد تم إنشاء هذا النظام الخاص بعملية تمييز أنماط العطلات وتحليل أسبابها أي ما يعرف بـ (FMEA)، وذلك اعتمادا على إنشاء شجرة تحليل الخطأ (FT- analysis) الخاصة بكل نظام من الأنظمة المكونة لمحطة توليد الطاقة. ان تصميم مثل هذا النظام المبرمج يمكن أن يستخدم من قبل مهندسي الطاقة في المحطة كوسيلة مساعدة في تسهيل عملية تمييز نوع العطل مع تحليل أسبابه وتأثيراته على النظام الشامل لوحدة إنتاج الطاقة وهذا يساعد على الإسراع في عملية تشخيص العطلات وإصلاحها وبالتالي تحسين كفاءة عمل المنظومة من خلال تطوير قابلية صيانة أنظمتها والتي تعتبر دالة من دوال موثوقية الأداء. ومن خلال التعديل في برمجة المعرفة الخاصة بهذا النظام يمكن تطبيقه في أنظمة صناعية أخرى.


Article
Using Vibration Signal with EHC System to Protect The Steam Turbine from Vibration

Author: Moneer Ali Lilo
Journal: Journal of University of Babylon مجلة جامعة بابل ISSN: 19920652 23128135 Year: 2014 Volume: 22 Issue: 6 Pages: 1805-1815
Publisher: Babylon University جامعة بابل

Loading...
Loading...
Abstract

This paper will working on the control valve main signal( demand) and the vibration of the steam turbine .will be putting condition to limiting the vibration increase in the turbine and generator, then when resolved the problem caused the turbine or generator vibration the main demand will return to normal value or normal turbine speed . This paper will take the power plant install from the Ansaldo company to work on this type of power plant . In this paper will us three type of circuit,this circuit contain op-amplifier us as comparator and the electronic relay to be isolate the signal in the circuit used and PNP &NPN transistor, by this working can be avoid the damage in turbine or generator result from vibration of the power plant.

في هذا البحث سوف نعالج الاشارة الرئسية الخاصة بالصمام الرئيسي مع الاشارة الخاصة بالاهتزاز .سوف نضع شرط لتحديد زيادة الاهتزاز بالتورباين االبخاري وكذلك المولد الكهربائي وتحديد السرعة ,وعند ازالة سبب الاهتزاز بالتوربين سوف يزيل هذا التحديد للسرعة. سوف يكون النموذج الخاص بهذا البحث هو منظومة مصنعة من قبل شركة انسالدوا الايطالية المستخدمة في المحطات .سوف نستخدم ثلاث انواع من الدوائر الاكترونية تحتوي على مكبر اشارة وكذلك صمام ترانستور من NPN وPNP , باستخدام هذه الاشارة سوفه نتجنب حدوث ضرر بالتورباين نتيجة ارتفاع الاهتزاز في المحطات الكهربائية .

Listing 1 - 6 of 6
Sort by
Narrow your search

Resource type

article (6)


Language

English (4)

Arabic and English (2)


Year
From To Submit

2014 (1)

2013 (1)

2009 (2)

2007 (1)

2005 (1)