research centers


Search results: Found 2

Listing 1 - 2 of 2
Sort by

Article
Effect of Temperature on the Stability and Release Profile of Ibuprofen Microcapsules

Author: Issraa R. Abed Al- Rahman اسراء رشيد عبد الرحمن
Journal: Iraqi Journal of Pharmaceutical Sciences المجلة العراقية للعلوم الصيدلانية ISSN: 16833597 Year: 2006 Volume: 15 Issue: 2 Pages: 37-45
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The stability and releasing profile of 2:1 core: wall ratio ibuprofen microcapsules prepared by aqueous coacervation (gelatin and acacia polymers coat) and an organic coacervation methods (ethyl cellulose and sodium alginate polymers coat) in weight equivalent to 300mg drug, were studied using different storage temperatures 40°C, 50°C ,60°C and refrigerator temperature 4°C in an opened and closed container for three months (releasing profile) and four months (stability study).It was found that, these ibuprofen microcapsules were stable with expiration dates of 4.1 and 3.1 years for aqueous and an organic method respectively.Aqueous prepared ibuprofen microcapsules were found more stable than those microcapsules prepared by organic method with activation energy (Ea) 4804.8 cal/mol and 5033.6 cal/mol of a drug respectively.The releasing percentage of ibuprofen for all microcapsules prepared by both methods was decreased as the storage temperatures increased, except for microcapsules prepared by aqueous method, which were found to be the same at 25-40°C as the standard one which stored at 25°C temperature, on the other hand , as the temperature decreased to 4°C (refrigerator ) of an open and closed container ,the amount of drug detected in microparticles is increased. These differences in the amount of drug released may be referred to the change in physical properties in polymer coats or in the amount of drug detected in a whole microcapsules.

تمت دراسة تأثير درجات الحرارة لكبسولات الايبوبروفين في درجات حرارة مختلفة (٦٠°م ,٥٠ °م، ٤٠ °م) واخرى بوضعها في درجة حرارة ٤°م) في وعائين مفتوح والأخر مغلق)على ثباتية وطريقة تحرر مادة الأيبوبروفين من النسبة( ٢: ١) للكبسولات المجهرية المحضرة بالطريقتين المائية (المغلفة بمادتي الجلاتين والصمغ العربي)والطريقة العضوية (لسليلوز الأثيل والجينيت الصوديوم ) بوزن يعادل ٣٠٠ ملغم من مادة الأيبوبروفين لمدة ثلاثة اشهر لدراسة تحرر الدواء واربعة اشهر لدراسة ثباتية الدواء .كان ثباتية تلك النسبة من الكبسولات المجهريه المحضرة بالطريقتين واضحا مع مدى صلاحية كل منهما١.٤ و ١.٣ سنوات للطريقتين المائية و العضوية على التوالي.ولقد وجد أن الكبسولات المجهرية المغلفة بالطريقة المائية أكثر ثباتية بسبب وجود المادة المصلبة للغلاف (الفورمالديهايد) التي تزيد من كفاءة التغليف وقابلية تحمله للحرارة العالية أو الرطوبة مع درجات حرارة منخفضة كان ذلك واضحا أيضا من خلال قلة طاقة تحفيز جزيئات الدواء.من جانب أخر وجد أن تحرر الدواء من تلك الكبسولات عند زيادة درجات حرارة الخزن تؤدي الى قلة في سرعة التحرر وعلى العكس بانخفاض درجات الحرارة ويعود ذلك الى التغيرات الفزياوية التي تحدث في المادة المغلفة للكبسولات المجهرية للأيبوبروفين والمشابهة لتحرر الأيبوبروفين من الكبسولات المجهرية المخزونة عند ٢٥°م عند خزنها في نفس تلك الدرجة, كما لوحظ تحرر الدواء من الكبسولات المجهرية المحضرة بالطريقة المائية لا تتغير مقارنة للنسبة الأصلية عند الدرجة ٢٥-٤٠°م.


Article
Thermal Performance of Plastic Receiver in Solar Collector
الاداء الحراري لمستقبل بلاستيكي في مجمع شمسي

Author: Kadhim Fadhil Nasir كاظم فاضل ناصر
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2019 Volume: 25 Issue: 7 Pages: 37-60
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

A plastic tubes used as absorber of active flat plate solar collector (FPSC) for heating water were studied numerically and experimentally. The set-up is located in Babylon (republic of Iraq) 43.80 East longitude and 32.30 North latitude with titled of 450 toward the south direction. The study involved three dimensions mathematical model for flat coil plastic absorber which solved by FLUENT-ANSYS-R.18 program. Experiments were conducted at outdoor conditions for clear days on January and February 2018 with various water volume flow rates namely (500, 750, 1000, 1250, and 1500 Liter per hour LPH) on each month for Reynolds number range of (1 x 104 to 5 x 104) through the receiver. The experimental results showed improvement in absorber input - output temperature difference, collector efficiency, and water storage temperature; the maximum input - output temperature difference is 3.1 °C, the maximum collector efficiency is 79%, and the maximum water storage temperature is 67 °C. The comparison validates a good agreement between the numerical and experimental results at variable operation conditions with maximum deviation of 4.2%. Also the experimental results were compared with previous study for similar condition and gave a good improvement.

تم اجراء دراسة عددية وعملية على مجمع شمسي من نوع الصفيحة المستوية الفعال باستخدام انابيب بلاستيكية كمستقبل شمسي. اجريت الدراسة العملية في محافظة بابل (العراق) عند خط طول 43.8 درجة شرقا و خط عرض 32.3 درجة شمالا مع زاوية ميلان 45 درجة مع الافق باتجاه الجنوب. تضمنت الدراسة بناء نموذج رياضي ثلاثي الابعاد للمستقبل البلاستيكي وتم حله بواسطة برنامج الانسز فلونت 18 . تم اجراء التجارب العملية في الاجواء الخارجية خلال شهري كانون الثاني وشباط 2018 لمعدلات جريان مختلفة للماء المار داخل المستقبل وهي (500, 750, 1000, 1250,و 1500) لتر بالساعه خلال كل شهر ولمدى رقم رينولد من 1*104 الى 5*104. اثبتت النتائج العملية فاعلية في فرق درجات الحرارة للماء مابين الدخول والخروج للمستقبل وفاعلية في كفاءة المجمع الشمسي ودرجات حرارة الماء المخزون حيث كان اكبر فرق بدرجات الحرارة هو 3,1 درجة مئوية و اكبر كفاءة للمجمع الشمسي هي 79% واعلى درجة حرارة للماء المخزون هي 67 درجة مئوية. تم اجراء مقارنه مابين النتائج العددية والعملية لهذا البحث وكان التطابق جيدا مع وجود فرق مقداره 4,2% كما تم اجراء مقارنه ما بين النتائج العملية لهذه الدراسة ونتائج الدراسات السابقة عند ظروف تشغيل متشابهة واعطت المقارنة افضلية جيده للدراسة الحالية.

Listing 1 - 2 of 2
Sort by
Narrow your search

Resource type

article (2)


Language

English (2)


Year
From To Submit

2019 (1)

2006 (1)