research centers


Search results: Found 25

Listing 1 - 10 of 25 << page
of 3
>>
Sort by

Article
Physical Adsorption of Reforming Catalyst by Nitrogen

Authors: Tariq M.Naife --- Hussain K.Hussain --- Abdul Halim A.K. Mohammed
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2006 Volume: 12 Issue: 2 Pages: 345-359
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Physical adsorption by nitrogen gas was studied on seven commercial platinum reforming catalysts (RG-402, RG-412, RG-432, RG-451, RG 422,RG-482, PS-10), four prepared platinum catalysts (0.1%Pt/alumina, 0.2 %Pt/alumina, 0.45 %Pt/alumina and 0.55% Pt/alumina), and γ-alumina support.Physical adsorption was carried out by using Accelerated Surface Area and Porosimetry (ASAP 2400 device) at 77 K . The results indicate that the surface area in general decreases with increasing platinum percentage,high platinum loaded (0.45% and 0.55%) it was found that the percent increasing in surface area was lower than those obtained for low platinum loaded catalysts , and at very higher platinum loading 0.6 %Pt , some reduction in surface area was observed . The precipitation of Re and Ir metals with 0.35 % and 0.6 % platinum increases the surface area , while precipitation of 0.57% Sn with 0.375% Pt/ γ-alumina deceases the surface area catalyst .

تم دراسة الإمتزاز الفيزياوي باستخدام غازالنتروجين للعوامل المساعدة التالية: سبعة عوامل مساعدة تجارية(RG-402, RG-412, RG-432, RG-451, RG 422,RG-482, PS-10) أربع عوامل مساعدة محضرة (0.1، 0.2، 0.45 و 0.55) % وزنا بلاتين (نسبة وزنية مئوية) محمل على الألومينا, اضافة الى كاما اوكسيد الالمنيوم.تم إجراء الإمتزاز الفيزياوي في درجة حرارة النيتروجين السائل (77)كلفن باستعمال جهاز قياس المساحة السطحية والمسامية (ASAP 2400). أظهرت النتائج أن المساحة السطحية تنخفض مع زيادة نسبة البلاتين المحمل على الألومينا بشكل عام وفي نسب البلاتينيوم العالية (0.55,0.45)% وجد بأن نسبة الزيادة في المساحة السطحية هي أقل من التي تم الحصول عليها في نسب البلاتينيوم الواطئة للعوامل المساعدة ،وجد ايضا بانه عندما تكون نسبة البلاتين عالية جدا 0.6% لوحظ أنخفاض بسيط في المساحة السطحية.أن ترسيب Re و Ir للعوامل المساعدة الثنائية المعدن بنسبة 0.35 % و 0.6 % من البلاتينيوم أدى الى زيادة في المساحة السطحية مقارنة بالعوامل المساعدة الاحادية المعدن , بينما ترسيب Sn بنسبة 0.57 % للعامل المساعد 0.357%البلاتين / كاما-الومينا أدى الى أنخفاض المساحة السطحية.


Article
The influence of various pH values on the aerogel physical properties by sol-gel technique
تأثير قيم pH المختلفة على الخصائص الفيزيائية للأيروجل بواسطة تقنية سول-جل

Authors: Baha Fakhry shehab بهاء فخري شهاب --- Wesam A. A. Twej وسام عبد علي تويج
Journal: Iraqi Journal of Physics المجلة العراقية للفيزياء ISSN: 20704003 Year: 2019 Volume: 17 Issue: 41 Pages: 75-81
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Hydrophobic silica aerogels were successfully preparation by an ambient pressure drying method from sodium silicate (Na2SiO3) with different pH values (5, 6, 7, 8, 9 and 10). In this study, acidic HCl (1M), a basic NH4OH (1M) were selected as a catalyst to perform the surface modification in a TMCS (trimethylchlorosilane) solution. The surface chemical modification of the aerogels was assured by the Fourier transform infrared (FTIR) spectroscopic studies. Other physical properties, such as pore volume and pore size and specific surface area were determined by Brunauer-Emmett- Teller (BET) method. The effect of pH values on the bulk density of aerogel. The sol–gel parameter pH value in the sol, have marked effects on the physical properties of the silica aerogels produced by this technique. The density and the hydrophobic tendency of the aerogels were significantly influenced.

تم تحضير سيليكا ايروجل بنجاح بواسطة طريقة تجفيف الضغط المحيط من سيليكات الصوديوم (Na2SiO3) مع قيم مختلفة من الدالة الحامضية pH(5، 6، 7، 8، 9 و10). في هذه الدراسة، قمنا باختيار حمض الهيدروكلوريك HCl(1M)، هيدروكسيد الأمونيوم NH4OH القاعدية (1M) كمحفزات، وقام بإجراء تعديل السطح بواسطة محلول TMCS (trimethylchlorosilane)، وتم تأكيد التعديل الكيميائي السطحي لعينات الايروجل بواسطة دراسة طيف تحويل فورير للأشعة تحت الحمراء ( FTIR). تم تحديد الخصائص الفيزيائية الأخرى، مثل حجم المسام ومساحة سطحه بواسطة طريقة بروناور-إيميت-تيلر (BET). تم إثبات تأثير قيم الأس الهيدروجيني على الكثافة الظاهرية لعينات الايروجل المعدة. إن قيمة الرقم الهيدروجيني لمعلمة sol-gel في sol، لها تأثيرات ملحوظة على الخواص الفيزيائية لعينات الايروجل التي تنتجها بهذه التقنية. كانت الكثافة والنزعة الكارهة للماء تتأثر بشكل كبير.


Article
Determination The Effect of ZnO on Iraqi Bentonite Surface Properties
تعيين تأثير اوكسيد الخارصين على خواص سطح البنتوبايت العراقي

Authors: Zahra A.K.AL-Asadi زهره عبد الكريم --- SariaA.Al-Safi سارية عبد الجبار --- KhuloodA.S.Al-saade خلود السعدي
Journal: Baghdad Science Journal مجلة بغداد للعلوم ISSN: 20788665 24117986 Year: 2013 Volume: 10 Issue: 3عدد خاص بموتمر الكيمياء Pages: 1034-1040
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Bentonite is widely used in industrial applications. The present study reports the effect of adding different weights of ZnO to the Iraqi bentonite, on surface area, pore volume and real density. These surface properties were evaluated for pure and modified bentonite. The modification was made by adding different ZnO weights such as; ( 0.5%, 1%, 5%, 10% ). The effect of heat exposing for all modified clay samples at 500 οC have been also evaluated. The results show that the addition of 0.5% ZnO leads to increase the surface area percentage about 36%, increase pore volume percentage about 5.48% and increase the real density percentage about 27.116%. When the samples exposed to 500 οC, their surface area and pore volumes have been decreased and the real density increased in compared with non-heat exposed samples.

طين البنتونايت له استخدامات واسعة في مجال التطبيقات الصناعية، في هذه الدراسة تمت متابعة تأثير اضافة أوزان مختلفة من أوكسيد الزنك لـ 10 غم من البنتونايت العراقي، على صفاته السطحية مثل المساحة السطحية، حجم المسام والكثافة الحقيقية للأطيان. تم تقدير الخواص السطحية للطين النقي وطين البنتونايت المحسن ( باضافة أوزان مختلفة من أوكسيد الزنك 1, 0.5, 0.1, 0.05 ) g) الى 10 غم من البنتونايت في 50 مل من الماء المقطر كمحلول عالق. تم تقدير تأثير تعريض نماذج الطين المحسنة في درجة حرارة 500 مئوي. بينت النتائج ان اضافة 0.05 غم من أوكسيد الزنك تؤدي الى زيادة المساحة السطحية بنسبة مئوية حالي 36%، وزيادة حجم المسام بنسبة 5.48% وزيادة نسبة الكثافة الحقيقية بـ 27.116%. تعريض النماذج لدرجة حرارة 500 οCأدى الى تقليل المساحة السطحية وحجم المسام وزيادة الكثافة النسبية مقارنة بالنماذج غير المعرضة للحرارة.


Article
Surface area measurements of upper dental cast with different final impressions

Author: Reem Abdul Rahim ريم عبد الرحيم
Journal: Journal of baghdad college of dentistry مجلة كلية طب الاسنان بغداد ISSN: 16800087 Year: 2013 Volume: 25 Issue: 2 Pages: 36-40
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Background : surface area anatomy is a proportional point to the retention of complete denture, in past there wasno quantitative method to evaluate the surface area, nowadays the size and shape of maxillary arch is measuredby different electronically and mathematical devices. A study was therefore, undertaken to measure surface areaof upper dental cast that was taken by different final impressions.Materials and methods: twenty patients were examined. All of them had a healthy palate with no singe of injury,trauma, or deformity. Casts were taken by three different final impressions; zinc oxide, additional silicon, and polyether. And two different devices were used; the computerized one and the Aluminum foil measure. Age, sex, andshape of upper dental arch were also evaluated.Results: the results of this study showed that the use of different methods to measure the surface area of upperdental cast had a significant difference between the two different measurements, while there was no difference inthe measurements between the different final materials. Age variable showed more significant difference betweenthe first and second method than sex variable.Conclusion: data collected in the present investigation showed a highly significant difference in measurementsbetween the computerized method and the direct foil method. Zinc oxide, silicon and poly ether materials showedno significant differences in readings


Article
Loquate Stones, a novel feedstock for Activated carbon production through chemical activation

Author: Mohammed M. Dheyab
Journal: Tikrit Journal of Pure Science مجلة تكريت للعلوم الصرفة ISSN: 18131662 Year: 2013 Volume: 18 Issue: 3 Pages: 70-75
Publisher: Tikrit University جامعة تكريت

Loading...
Loading...
Abstract

The objective of this study is to produce activated carbons with high adsorption capacities from Loquate stones. Chemical activation using phosphoric acid and potassium hydroxide was used to produce the activated carbons. Surface area of the produced carbon were determined through various methods namely adsorption from solution by using iodine, p-nitro phenol and methylene blue as solutes, adsorption from vapor phase by using hexane and ethanol vapors, and retention method by using ethylene glycol mono ethyl ether (EGME) as an adsorbate .Surface area of the produced carbons were high using iodine as adsorbate implying that the produced carbons have micro porous structure. Furthermore, adsorption isotherms of the adsorption of methylene blue and PNP were determined and found conform with Langmuir type of adsorption which indicates the micro porous structure of the produced carbons.

تهدف هذه الدراسة الى انتاج كاربون منشط ذو سعة امتزاز عالية من نوى العنكودنيا , حيث تم في هذا البحث اعتماد اسلوب التنشيط الكيميائي باستخدام العوامل الكيميائية من حامض الفسفوريك وهيدروكسيد البوتاسيوم. المساحة السطحية النوعية للكاربون المنشط الناتج تم تعيينها بعدة طرق, طريقة الامتزاز باستخدام اليود, بارا نايترو فينول (PNP), وصبغة المثلين الازرق (MB) للمذاب, طريقة امتزاز الابخرة باستخدام الهكسان والايثانول, وطريقة الاحتفاظ باستخدام اثلين كلايكول مونو ايثايل ايثر(EGME). كانت المساحة السطحية للكاربون المنشط الناتج عالية باستخدام اليود مما يعني ان الكاربون المنشط الناتج لديه بنية ذات مسامات صغيرة جدا, اضافة الى ذلك, تم تعيين ايزوثرمات الامتزاز للنماذج المحضرة من خلال الامتزاز من المحلول المائي لصبغة (MB) ومادة (PNP), وكانت هذه الايزوثرمات متلائمة مع نوع لاكماير من ايزوثرمات الامتزاز مما يدل على ان الكاربون المنشط الناتج ذات تراكيب مسامية دقيقة .


Article
Measurements of Pressure Area for Different Pressure Indicating Materials

Authors: Reem Abdul Rahim --- Hadeel Adnan
Journal: Medical Journal of Babylon مجلة بابل الطبية ISSN: 1812156X 23126760 Year: 2015 Volume: 12 Issue: 4 Pages: 1146 -1153
Publisher: Babylon University جامعة بابل

Loading...
Loading...
Abstract

Pressure indicator during insertion of removable prosthesis can help identify potential areas of discomfort resulting from different errors during prosthetic work, correct diagnosis of specific problem relies on proper application of pressure indicator. A study was therefore, undertaken to measure pressure area of upper and lower complete dentures using different types of pressure indicating materials. Thirty two processed dentures were examined. All of them had a clear tissue surface with no sharp projections to minimize patient discomfort. Three different pressure indicating materials ; zinc oxide, alginate, and extra light silicon were used, surface area measurements were evaluated for each material. Setting time, ease of remove, no. of sites, and coast of the materials were also evaluated.The results of this study showed that there was a significant difference in pressure area measurements between the three different pressure indicating materials, while there was no difference between alginate and silicon- alginate and zinc oxide materials, while there was a significant difference between silicon and zinc oxide pressure materials. Setting time appreciation showed that silicon set in shorter time than alginate and zinc oxide materials, while for cost variable discussion silicon material revealed a higher cost means than both alginate and zinc oxide materials.In the present investigation data collected showed a significant difference in pressure area measurements between silicon and zinc oxide materials. Silicon, and alginate pressure materials showed no difference in pressure area readings between them.


Article
Body Surface Area and Sheath Size as a Risk Factors for Vascular Complications After Coronary Angiography Via Femoral Approach

Author: Salah Mahdy Majeed
Journal: Iraqi Academic Scientific Journal المجلة العراقية للاختصاصات الطبية ISSN: 16088360 Year: 2016 Volume: 15 Issue: 4 Pages: 481-485
Publisher: The Iraqi Borad for Medical Specialization المجلس العراقي للاختصاصات الطبية

Loading...
Loading...
Abstract

ABSTRACT:BACKGROUND: Vascular complications have been recognized as an important factor in morbidity after diagnostic and percutaneous coronary interventions.OBJECTIVE: This study sought to evaluate vascular body mass index and sheath size as risk factors for vascular complications after diagnostic coronary angiography via femoral approach.PATIENTS AND METHODS: This historical prospective cohort study was carried out from February 2012 till January 2013, at the Iraqi Center for the Heart Disease. A total number of 2400 patients underwent 3600 procedures, diagnostic coronary angiography (2196) and PCI(1404) via their common femoral arteries.Result: Body surface area > 2m2 is a statistically significant factor for vascular complications, and <1.6m2 is also an important statistically significant risk for vascular complications.The results of the current study according to sheath size show:- during the diagnostic coronary angiograph procedures, sheath size 5F was the least(n=34), in which no reported vascular complications. Sheath size 6F (n = 1661) with (75) 4.5% complicated vs. (1586) 95.5% didn’t, sheath size 7F used among (501) patients, vascular complications developed in (171) 34.1% vs. (330) 65.9%. In comparison between the incidence of vascular complications among sheath sizes (6F, 7F) vs. 5F the P value < 0.001 for both. During the PCI procedures, sheath size 6F was used among (140) patients, with vascular complications in one patient (0.7%). 7F used among (1219), with vascular complications in (115) 9.4%, and 8F used in (45) patients with vascular complications in (45) 100%. By using 6F as a referent, sheaths 7F&8F were statistical significant(p


Article
The Value of the chest X-Ray for diagnosing left ventricularDysfunction

Authors: Kasim M. AL- Doori --- Layth R. Shareef
Journal: Journal of the Faculty of Medicine مجلة كلية الطب ISSN: 00419419 Year: 2009 Volume: 51 Issue: 1 Pages: 23-26
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Background: The use of the chest x-ray measurements which includes the cardiothoracic ratio(C-T) and frontal area (FA) of the heart by the CXR are useful measures for primary assessment of the cardiac dysfunction.
Patients and Methods: A Prospective study was done from the 1st of January 2005 to the 1st of October in the same year on a 120 consecutive patients who have been admitted for coronary and L.V angiogram at IBN-AL-BITAR hospital. The C-T ratio and the frontal area were measured.
Results: The study comprised 120 subjects who were admitted for coronary and L.V angiogram for diagnostic reasons. 89subjects (74.2%) are male and 31subjects (25.8%) are female .17(14%) subjects have left ventricular dysfunction and dilated L.V with EDV&#8805;110 cm^2 by angiogram. (76) Subjects (71%) had LAD (Left anterior descending artery disease), (40) subjects (37%) had LCX (Left circumflex artery disease), 10subjects (9%) had LMS (Left main stem artery disease) and (38) subjects (34%) RCA (disease). 13subjects (10%) had valve disease , 2subjects (1%) of them have aortic stenosis , 5 subjects (4%) had A.I (aortic inche), 4 subjects (3%) had M.S(Mitral stenosis) , 6 subjects (5%) had M.R Mitral regurgitation and combined valve disease .The abnormal chest radiogram C/T Ratio had a sensitivity of 56.6%, a specificity of 78.6%, and positive ,negative predictive values and accuracy of 95.2% ,19.3% and 59.2% respectively, in the diagnosis of left ventricular dysfunction.while the abnormal chest radiogram FA/BSA £ had a sensitivity of 47.2%, specificity of 42.9%, and positive ,negative predictive values and accuracy of 86.2% ,9.7% and 46.7% respectively.
Conclusion: The radiological study of the thorax is not an accurate indicator of left ventricular dysfunction; its use as a screening method to initially approach the patient with ventricular dysfunction should be reevaluated.


Article
The adsorption-desorption process as a method for separation of nitrogen-carbon dioxide gas mixture using activated carbon
عملية الامتزاز والابتزاز كطريقة لفصل مزيج غازي النيتروجين وثاني أوكسيد الكاربون وباستخدام الفحم المنشط

Author: Faris Ibrahim Saleh فارس إبراهيم صالح
Journal: Baghdad Science Journal مجلة بغداد للعلوم ISSN: 20788665 24117986 Year: 2009 Volume: 6 Issue: 2 Pages: 302-308
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Gas adsorption phenomenon on solid surface has been used as a mean in separation and purification of gas mixture depending on the difference in tendencies of each component in the gas mixture to be adsorbed on the solid surface according to its behaviour. This work concerns to study the possibilities to separate the gas mixture using adsorption-desorption phenomenon on activated carbon. The experimental results exhibit good separation factor at temperature of -40 .

استخدمت ظاهرة امتزاز الغاز على سطوح المواد الصلبة في مجال فصل الغازات من مزيجها وتنقيتها اعتماداً على الاختلاف في ميل الغازات المكونة للمزيج للامتزاز على سطح المادة الصلبة وحسب الطبيعة الكيميائية والفيزيائية لتلك الغازات. جرى في هذه الدراسة توظيف لهذه الظاهرة في فصل غازي النيتروجين وثاني أوكسيد الكاربون باستخدام الفحم النباتي المنشط حيث أظهرت النتائج التجريبية أن أفضل مقدار لمعامل الفصل كان عند درجة حرارة -40 م وأن التواصل في تكرار عملية الامتزاز يؤدي الى الحصول على فصل الغازين وتنقيتهما.


Article
Adsorption Study of Hydrodesulphurization Catalyst

Author: Tariq M.Naife
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2012 Volume: 18 Issue: 1 Pages: 38-50
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Physical and chemical adsorption analyses were carried out by nitrogen gas using ASTM apparatus at 77 Kand hydrogen gas using volumetric apparatus at room temperature respectively. These analyses were used fordetermination the effect of coke deposition and poisoning metal on surface area, pore size distribution andmetal surface area of fresh and spent hydrodesulphurization catalyst Co-MoAl2O3 .Samples of catalyst (fresh and spent) used in this study are taken from AL-Dura refinery.The results of physical adsorption shows that surface area of spent catalyst reduced to third compare withfresh catalyst and these catalysts exhibit behavior of type four according to BET classification ,so, the poresof these samples are cylindrical, and the pores of fresh catalyst suffers during the hydrodesulphurization .The result of chemical adsorption shows that the metal surface area of fresh catalyst is 50.72 m2/g while itreduced to 39.04 m2/g for spent catalyst.

تم اجراء تحاليل الامتزاز الفيزياوي والكيمياوي باستعمال غاز النتروجين وبواسطة جهاز ASTM وبدرجة حرارة 77 K،وباستعمال غاز الهيدروجين بواسطة منظومة حجمية للامتزاز وبدرجة حرارة الغرفة على التوالي، هذه التحاليل تستعمل لحساب تاثير المواد الكاربونية والسمية على المساحة السطحية وحجم التوزيع المسامي والمساحة السطحية للمعدن للعامل المساعد Co-MoAl2O3 الطازج والمستهلك المستعمل في عملية إزالة الكبريت . جميع نماذج العامل المساعد (الطازجة والمستهلكة) تم أخذها من مصفى الدورة .تبين النتائج المستحصلة لعملية الامتزاز الفيزياوي بان قيمة المساحة السطحية للعامل المساعد المستهلك قلت للثلث مقارنة بالعامل المساعد الطازج وإن هذه العوامل المساعدة أظهرت النمط الرابع وفقا لتصنيف BET لمتساويات درجة الحرارة للامتزاز ،لذا فان مسامات هذه المواد هي من النوع الاسطواني.وقد عانى العامل المساعد الطازج نتيجة الاستخدام إلى فقدان الكثير من مساميته ومساحته السطحية بسبب عملية السلفرة الهيدروجينية .أظهرت نتائج الامتزاز الكيمياوي إلى ان المساحة السطحية للمعدن الطازج 50.72 م2/غم بينما تقل لتساوي 39.04 م2/غم للعامل المساعد المستهلك .

Listing 1 - 10 of 25 << page
of 3
>>
Sort by
Narrow your search

Resource type

article (25)


Language

English (20)

Arabic (2)

Arabic and English (2)


Year
From To Submit

2019 (2)

2016 (5)

2015 (3)

2014 (1)

2013 (4)

More...