research centers


Search results: Found 7

Listing 1 - 7 of 7
Sort by

Article
ASSAY OF TETRACYCLINE IN PHARMACEUTICAL PREPARATIONS, SPIKED INDUSTRIAL WASTEWATER AND CHICKEN MEAT SAMPLES USING VISIBLE SPECROPHOTOMETER TECHNIQUE
تقدیر التتراسایكلین طیفیا في المستحضرات الصیدلانیة ولحم الدجاح والمیاه الصناعیة المطروحة

Loading...
Loading...
Abstract

A simple, accurate, and rapid visible spectrophotometric method has beendeveloped for the determination of tetracycline hydrochloride in pure, pharmaceuticalpreparations and environmental water samples. The method is based on the oxidationof tetracycline hydrochloride by sodium hypochlorite in alkaline medium to form ared colored product with an absorption maximum at 400 nm. Beer’s Law was obeyedin the range of 2-24 µg/ml with molar absorptivity of 1.346×104 L.mol.-1.cm-1. Therelative standard deviation of the method was less than 2% and accuracy (averagerecovery ) was 100 ± 0.85 % .The optimum conditions for all color development aredescribed and the proposed method has been successfully applied for thedetermination of tetracycline hydrochloride in pharmaceutical preparations, chickenmeat and waste water samples.

تم اختبار طریقة طیفیة جدیدة مباشرة لتقدیر التتراسایكلین في حالتھ النقیة وفي بعض مستحضراتھ الدوائیة وفيلحم الدجاج وفي المیاه الصناعیة المطروحة،تتمیز الطریقة بالبساطة والانتقائیة والحساسیة والدقة وتعتمد الطریقةعلى أكسدة التتراسایكلین بواسطة الھایبوكلورات في الوسط القاعدي لتعطي ناتج احمر اللون لھ أقصى امتصاصعند الطول ألموجي 400نانومیتر وأمكن تقدیر الكمیات التي تتراوح بین 24-2مایكروغراممل وان معاملالامتصاص المولاري للطریقة المقترحة ھو 1.346×104لتر .مول-.1سم-.1ان الانحراف القیاسي النسبيللطریقة أقل من % 2وبدقة )معدل استرجاعیة( . % 0.85 ±100وتم دراسة الظروف المثلى للتفاعل .وطبقتالطریقة بنجاح لتقدیرھیدروكلورید التتراسایكلین في حالتھ النقیة وفي مستحضراتھ الصیدلانیة وفي لحم الدجاجوفي المیاه الصناعیة المطروحة


Article
Sensitive Spectrophotometric Determination of Tetracycline Hydrochloride Indosage forms using Sodium Nitroprusside and Hydroxylamine Hydrochloride

Authors: Hind Hadi --- Ghadah Fadhil
Journal: Al-Nahrain Journal of Science مجلة النهرين للعلوم ISSN: (print)26635453,(online)26635461 Year: 2014 Volume: 17 Issue: 3 Pages: 53-58
Publisher: Al-Nahrain University جامعة النهرين

Loading...
Loading...
Abstract

An optimized and validated spectrophotometric method has been developed for the determination of Tetracycline hydrochloride (TCH) in pharmaceutical formulations. The method is based on the reaction between TCH, sodium nitroprusside and hydroxylamine hydrochloride in alkaline medium. The product absorbed maximally at 529 nm. Beer’s law is obeyed in the working concentration range of 2-60 µg mL-1 with apparent molar absorptivity of 5.049×103 L mol-1cm-1 and Sandell’s sensitivity of 0.0952 µg cm2/ 0.001 absorbance unit. The proposed procedure was applied successfully for estimation of drug in different commercial forms. The proposed method was applied to the determination of the studied drug in pharmaceutical formulations and the results demonstrated that the method is equally accurate and precise as the official method as found from the t- and F-values.

يتضمن البحث تطوير طريقة طيفية سريعة وحساسة للتقدير الكمي للمقادير الضئيلة من مستحضر التتراسايكلين هيدروكلورايد في المحاليل المائية والمستحضرات الصيدلانية باستخدام الطريقة الطيفية. تعتمد الطريقة على التفاعل بين التتراسايكلين وكاشف نتروبروسيد الصوديوم وهيدروكسيل امين هيدروكلورايد في الوسط القاعدي. بلغ مدى الخطية 2-60 مايكروغراممل من التتراسايكلين حيث تم القياس عند طول موجي 529 نانومترا. قيمة الامتصاصية المولارية وحساسية ساندل مساوية الى 5.049 ×103 لتر.مول-1.سم-1 و 0.0952 مايكروغرام .سم-2 على التوالي .طبقت الطريقة المقترحة بنجاح لتقدير الدواء في مستحضراته الصيدلانية حيث اثبتت النتائج من خلال اختباري t وF بعدم وجود اختلاف بالدقة والتوافقية بين الطريقة المقترحة والطريقة القياسية.


Article
Batch and Flow Injection Spectrophotometric Determination of Tetracycline Hydrochloride and Doxycycline Hyclate in Pharmaceutical Preparations
التقدير الطيفي للتتراسايكلين هيدروكلورايد والدوكسي سايكلين هايكلات في المستحضرات الصيدلانية بطريقة الدفعة والحقن الجرياني

Authors: Mouayed Q. Al-Abachi مؤيد قاسم العبايجي --- Zaid A. Al-Nedawi زيد عبد الستار النداوي
Journal: Iraqi Journal of Science المجلة العراقية للعلوم ISSN: 00672904/23121637 Year: 2015 Volume: 56 Issue: 2A Pages: 909-920
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

New, simple and accurate batch and flow injection spectrophotometric methods have been developed for the determinationsof tetracycline hydrochloride (TCH) and doxycycline hyclate (DCH) in pharmaceutical preparations.The methods are based on diazotization of metchlopramide and coupling reaction with either TCH or DCH in alkaline medium to form yellow–orange water soluble dye with absorption maxima at 414 and 436 nm for TCH and DCH, respectively. A graphs of absorbance versus concentration show that Beer’s law was obeyed over the concentration ranges of 1 –52 µgmL-1 TCH and DCH for batch method and of 8 – 240 µg mL-1 TCH and 5 – 350 µgmL-1 DCH for FIA method. The limits of detection in batchmethods were 0.333 and 0.235µgmL-1for TCH and DCH respectively, and in FIA methods were 0.895, 0.612 µgmL-1for TCH and DCH respectively. Samplethroughputs in FIA procedures were 120 and 80samples per hour for TCH and DCH, respectively. Different chemical and physical experimental parameters affecting on the development and stability of the colored product were carefully studied and the proposed methods were successfully applied for determination of TCH and DCH in pharmaceutical preparations.

يتضمن البحث تطوير طرائق بسيطة وجديدة وذلك باستخدام تقنية المطياف الضوئي بطريقة الدفعة والحقن الجرياني للتقدير الكمي لكل من التتراسايكلين هيدروكلورايد و الدوكسي سايكلين هايكلات في المستحضرات الصيدلانية .اعتمدت الطرائق على تفاعل الازودتة والازدواج بين الميتكلوربرمايد المؤزوت والتتراسايكلين والدوكسي سايكلين حيث تتكون نواتج من اصباغ الاوزو الملونة وذائبة بالماء اعطتا على قمة امتصاص عند طول موجي414 و436نانوميتر لكل من التتراسايكلين والدوكسي سايكلين على التوالي . تشير منحنيات الامتصاص مقابل التركيز بانقانونبيرينطبقضمنمدىالتركيز52-1و50-1 مايكروغرام لكل مل لكل من التتراسايكلين هيدروكلورايد والدكوكسي سايكلين على التوالي وبحدودكشف 0.333 و 0.235 مايكروغرام لكل مل للتتراسايكلين هيدروكلورايد والدوكسي سايكلين هيكلات على التوالي لطريقةالدفعة.امابطريقةالحقن- الجريانيفكانمدى التراكيز من 280-5 و350-5 مايكرو غرام لكل مل للتتراسايكلين هيدروكلورايد والدوكسي سايكلين هيكلات على التوالي، وحدود الكشفكانت0.895 و0.612 مايكروغرام لكل مل للتتراسايكلين والدوكسي سايكلين على التوالي، تمت دراسة الظروفالمثلى للمتغيراتالكيميائيةوالفيزيائيةبدقةوطبقتالطريقتينبنجاحعلى المستحضرات الصيدلانية الحاويةعلى التتراسايكلينهيدروكلورايد والدوكسي سايكلين هيكلات.وقورنتالنتائجالتيتمالحصولعليها معنتائجطرائقالتحليل القياسبةللادويةاعلاهواظهرتنتائجالمقارنةعدموجودفرق جوهري بين نتائج الطرائق المقترحة ونتائج الطريقة القياسية .


Article
Flow injection spectrophotometric determination of Tetracycline hydrochloride in pharmaceutical samples
التقدير الطيفي الحقن الجرياني للتتراسايكلين هيدروكلورايد في النماذج الصيدلانية

Loading...
Loading...
Abstract

AbstractTetracycline hydrochloride (TCH) was determined spectrophoto-metrically in the pure form and in the pharmaceutical formulations using flow injection analysis (FIA). The automated method is based on the reaction between TCH, sodium nitroprusside and hydroxylamine hydrochloride in alkaline medium. The product absorbed maximally at 529 nm. The calibration graph of TCH is linear from 25-1000 µg mL-1 with detection limit (S/N=3) of 7.589 µg mL-1 and sample through put of 69 h-1. The various chemical and physical variables were optimized and the proposed procedure was applied successfully for estimation of drug in different commercial forms.

الخلاصةتم تقدير التتراسايكلين هيدروكلورايد بشكله النقي وفي المستحضرات الصيدلانية طيفيا باستخدام تقنية التحليل بالحقن الجرياني.تعتمد الطريقة المؤتمتة على التفاعل بين التتراسايكلين وهيدروكسيل امين هيدروكلورايد في الوسط القاعدي.الناتج اعطى اعلى امتصاص عند 529 نانومترا وبلغ مدى الخطية من 25-1000 مايكروغرام من التتراسايكلين هيدروكلورايد لكل مللتر من المحلول وبحد كشف 7.589 مايكروغرام مل-1 وبمعدل نمذجة 69 نموذج بالساعة.تمت دراسة جميع التغيرات الفيزيائية والكيميائية وتم تطبيق الطريقة وبنجاح لتقدير الدواء بمختلف اشكاله التجارية.


Article
Spectrophotometric Determination of Tetracycline Hydrochloride in Pure Form and Pharmaceutical Preparation by Coupling with Diazotized Anthranilic Acid
التقدير الطيفي للتتراسايكلين هيدروكلوريد بصورته النقية وفي مستحضرات صيدلانية بالاقتران مع حامض الانثرانلك المؤزوت

Loading...
Loading...
Abstract

A simple, fast and sensitive spectrophotometric method has been applied for the determination of tetracycline hydrochloride in its pure form and in pharmaceutical preparations. The method based on coupling reaction of the antibiotic with diazotized anthranilic acid to form a stable yellow azo dye which shows a maximum absorption at 419 nm. Uni- and multivariate approaches were followed in optimizing the experimental conditions. Under optimum experimental conditions obtained via multivariate (Central Composite Design), the linearity of the constructed calibration curve was in the range of 0.5-60 μg.mL-1 with molar absorptivity of 14619 L.mol-1.cm-1 and the value of detection limit was 0.2813μg.mL-1. The capability of the method for the analysis of real tetracycline samples was evaluated. The results show that the method could successfully be applied with no significant interference from the common excipients.

تم استعمال طريقه طيفيه سهلة وسريعة وحساسة لتقدير دواء تتراسايكلين هيدروكلوريد في عيناته النقية وفي بعض المستحضرات الصيدلانية. تعتمد الطريقه على تفاعل اقتران للمضاد الحيوي اعلاه مع حامض الانثرانلك المؤزوت لتكوين صبغه آزو مستقرة صفراء اللون أعطت اعلى امتصاص عند الطول الموجي 419 نانوميتر، اذ استعملت طريقة المتغيرات الاحادية والمتعددة لضبط ظروف التجربة. أعطت طريقة المتغيرات المتعددة (تصميم التراكم المركزي) خطية تراوحت بين (0.5-60) ميكروغرام.ملليتر-1 وامتصاصية مولية مقدارها 14619 لتر.مول-1.سنتيمتر-1 وبحد كشف يساوي 0.2813 ميكروغرام.ملليتر-1. تم تطبيق الطريقه بنجاح في تقدير تتراسايكلين هيدروكلوريد في بعض المستحضرات الصيدلانية وبدون تأثير يذكر على قيم الامتصاص من المتداخلات المتواجدة في تلك المستحضرات.


Article
Direct Determination of Tetracycline Hydrochloride and the Interaction with Bovine Serum Albumin by UV Spectra in Water
التقدير المباشر لتتراسايكلين هيدروكلورايد وتداخله مع مصل الالبومين ألبقري بواسطة الأشعة فوق البنفسجية

Authors: Isam J. Al-Nuri عصام جمال الدين النوري --- Banan A. Akrawi بنان احمد عقراوي --- Sana A. Hussin سناء علي حسين
Journal: Rafidain journal of science مجلة علوم الرافدين ISSN: 16089391 Year: 2017 Volume: 26 Issue: 1E Pages: 77-91
Publisher: Mosul University جامعة الموصل

Loading...
Loading...
Abstract

The UV fourth order derivative spectra were selected as the more reliable technique for the direct quantification of pure Tetracycline Hydrochloride in water, after the measurement of the zero, first, second, third and fourth order spectra, within the concentration range at (0.2885-144.27)µg/ml with R2 =0.9998 and RSD=0.215 %. Bovine serum albumin was directly quantified by the fourth order UV derivative technique within the concentration range (6.7-2680) µg/ml with R2 = 0.9998 and RSD=0.324 %. Appreciable interaction between Tetracycline hydrochloride and Bovine serum Albumin was found in accordance with the fraction coefficient and the apparent binding constant. The UV–fourth order derivative technique appears to be in a good accuracy and precise method for the direct quantification of Tetracycline Hydrochloride and Bovine Serum Albumin (BSA) in water.

يتضمن البحث تطبيق طريقة المشتقة الرابعة للأشعة فوق البنفسجية للتقدير الكمي المباشر، للتتراسايكلين هيدروكلورايد في الماء وبعد أن تم قياس مشتقات الأطياف الأخرى الأولى، الثانية، الثالثة والرابعة وجد إن انسب طريقة وأكثرها حساسية هي طريقة المشتقة الرابعة وتم استخدامها في التقدير المباشر لمصل الالبومين ألبقري وجد أن هناك تداخلا" بنسبة جيدة بين عقار التتراسايكلين هيدروكلورايد ومصل الالبومين ألبقري من خلال حساب قيمة نسبة التوزيع الجزئي وثابت الترابط الظاهري العالية. وتعد طريقة المشتقة الرابعة استنادا" إلى النتائج المستحصلة طريقة ذات دقة وتوافقية جديدتين بالإضافة إلى سهولة القياس.


Article
Colorimetry and Indirect X-ray Fluorescence Determination of Active Ingredients in Tetracycline Hydrochloride Drug and Injection Solution of B12 Vitamin Using of Polyurethane Foam Sorbents

Loading...
Loading...
Abstract

The simple and available technique of colorimetry and indirect X-ray fluorescence determination of tetracycline hydrochloride (in the form of the colored complex with iron(III) ions) and cyanocobalamine (in the form of the colored thiocyanate complex with cobalt(II) ions) is offered. The analytes were separated from the accompanying components by sorption to polyurethane foam based on ethers. The conditions of sorption separation and measurement of the analytical signal of these substances are optimized. The obtained results of tetracycline drug and injection solution of the B12 vitamin are in satisfactory agreement with data declared by the manufacturer.

The simple and available technique of colorimetry and indirect X-ray fluorescence determination of tetracycline hydrochloride (in the form of the colored complex with iron(III) ions) and cyanocobalamine (in the form of the colored thiocyanate complex with cobalt(II) ions) is offered. The analytes were separated from the accompanying components by sorption to polyurethane foam based on ethers. The conditions of sorption separation and measurement of the analytical signal of these substances are optimized. The obtained results of tetracycline drug and injection solution of the B12 vitamin are in satisfactory agreement with data declared by the manufacturer.

Listing 1 - 7 of 7
Sort by
Narrow your search

Resource type

article (7)


Language

English (6)

Arabic and English (1)


Year
From To Submit

2018 (1)

2017 (3)

2015 (1)

2014 (2)