research centers


Search results: Found 5

Listing 1 - 5 of 5
Sort by

Article
Using Hydraulic Modeling With Solar Energy To Optimize The Chlorine Contact Tanks

Author: Ali Hadi Ghawi
Journal: Journal of University of Babylon مجلة جامعة بابل ISSN: 19920652 23128135 Year: 2012 Volume: 20 Issue: 1 Pages: 229-242
Publisher: Babylon University جامعة بابل

Loading...
Loading...
Abstract

Traditionally, contact time of a chlorine contact tank (CCT) in waster water treatment plants is determined by performing field tracer tests. This paper presents an alternative approach by using computational fluids dynamics (CFD) modeling to predict the contact time. This method is known as numerical tracer testing. Numerical tracer testing was used for determining the contact time at the Al-Dewanyia Wastewater Treatment Plant in Al-Dewanyia The CCT is of 1600 m3 volume, five-pass baffled tank capable of handling up to 1000 m3/ hr . CFD results were compared to field data obtained by a step-feed field tracer tests using Rhodamine-wt. The comparison shows that CFD modeling is capable of accurately predicting contact times in the CCT. Results of CFD modeling, including flow streamlines, velocity contours and vectors, were used to improve velocity distribution and reduce solids deposition, short-circuiting and vortices with the inclusion of SolarBee mixers. The CFD modeling has clearly illustrated the short-circuiting phenomenon that occurs without the SolarBee mixer in place. SolarBees can be effectively used to prevent short-circuiting by being placed directly in the short-circuiting path. The study demonstrates that CFD modeling is a valuable modeling tool for wastewater industry.

من الحقائق العلمية الشائعة في حساب زمن بقاء الكلور في حوض التعقيم في محطات معالجة مياه الصرف الصحي هو اختبار اضافة صبغة في الحوض. في هذا البحث تم استخدام موديل رياضي يسمى ديناميكا السوائل الحسابية لغرض حساب زمن بقاء الكلور في حوض التعقيم. هذة الطريقة تسمى الطريقة العددية لأضافة الصبغة في حوض التعقيم. تم استخدام الطريقة العددية لأضافة الصبغة لغرض دراسة أمكانية تحسين أداء حوض التعقيم في محطة معالجة مياة الصرف الصحي في مدينة الديوانية. ان حجم حوض التعقيم في محطة معالجة مياة الصرف الصحي في مدينة الديوانية هو 1600 م3 و يتكون من خمسة مصدات (جدران) بتصريف اكثر من 1000 م3ساعة. تم مقارنة نتائج الموديل الرياضي مع التجارب الحقلية باستخدام صبغة Rhodamine-wt. المقارنة اثبتت دقة الموديل الرياضي في ايجاد زمن بقاء الكلور في الحوض. نتائج الموديل الرياضي شملت خطوط الجريان و السرعة التي استخدمت لتحسين اداء حوض التعقيم بتحسين توزيع السرع و تقليل الدوامات والمناطق المعدومة السرعة بعد استخدام خلاطات تعمل بالطاقة الشمسية وزعت على امتداد حوض التعقيم. و في هذة الدراسة تم ايجاد تاثير اضافة وعدم اضافة خلاطات تعمل بالطاقة الشمسية على تقليل الدوامات و زيادة كفاءة حوض التعقيم. اثبتت هذة الدراسة فعالية النموذج الرياضي المستخدم في هذة الدراسة لتصميم محطات معالجة مياه الصرف الصحي.

Keywords

contact tank --- CFD --- RTD --- SolarBee mixer --- tracer --- wastewater


Article
Using Hydraulic Modeling With Solar Energy To Optimize The Chlorine Contact Tanks

Author: Ali Hadi Ghawi
Journal: Journal of University of Babylon مجلة جامعة بابل ISSN: 19920652 23128135 Year: 2012 Volume: 20 Issue: 1 Pages: 229-242
Publisher: Babylon University جامعة بابل

Loading...
Loading...
Abstract

Traditionally, contact time of a chlorine contact tank (CCT) in waster water treatment plants is determined by performing field tracer tests. This paper presents an alternative approach by using computational fluids dynamics (CFD) modeling to predict the contact time. This method is known as numerical tracer testing. Numerical tracer testing was used for determining the contact time at the Al-Dewanyia Wastewater Treatment Plant in Al-Dewanyia The CCT is of 1600 m3 volume, five-pass baffled tank capable of handling up to 1000 m3/ hr . CFD results were compared to field data obtained by a step-feed field tracer tests using Rhodamine-wt. The comparison shows that CFD modeling is capable of accurately predicting contact times in the CCT. Results of CFD modeling, including flow streamlines, velocity contours and vectors, were used to improve velocity distribution and reduce solids deposition, short-circuiting and vortices with the inclusion of SolarBee mixers. The CFD modeling has clearly illustrated the short-circuiting phenomenon that occurs without the SolarBee mixer in place. SolarBees can be effectively used to prevent short-circuiting by being placed directly in the short-circuiting path. The study demonstrates that CFD modeling is a valuable modeling tool for wastewater industry.

من الحقائق العلمية الشائعة في حساب زمن بقاء الكلور في حوض التعقيم في محطات معالجة مياه الصرف الصحي هو اختبار اضافة صبغة في الحوض. في هذا البحث تم استخدام موديل رياضي يسمى ديناميكا السوائل الحسابية لغرض حساب زمن بقاء الكلور في حوض التعقيم. هذة الطريقة تسمى الطريقة العددية لأضافة الصبغة في حوض التعقيم. تم استخدام الطريقة العددية لأضافة الصبغة لغرض دراسة أمكانية تحسين أداء حوض التعقيم في محطة معالجة مياة الصرف الصحي في مدينة الديوانية. ان حجم حوض التعقيم في محطة معالجة مياة الصرف الصحي في مدينة الديوانية هو 1600 م3 و يتكون من خمسة مصدات (جدران) بتصريف اكثر من 1000 م3ساعة. تم مقارنة نتائج الموديل الرياضي مع التجارب الحقلية باستخدام صبغة Rhodamine-wt. المقارنة اثبتت دقة الموديل الرياضي في ايجاد زمن بقاء الكلور في الحوض. نتائج الموديل الرياضي شملت خطوط الجريان و السرعة التي استخدمت لتحسين اداء حوض التعقيم بتحسين توزيع السرع و تقليل الدوامات والمناطق المعدومة السرعة بعد استخدام خلاطات تعمل بالطاقة الشمسية وزعت على امتداد حوض التعقيم. و في هذة الدراسة تم ايجاد تاثير اضافة وعدم اضافة خلاطات تعمل بالطاقة الشمسية على تقليل الدوامات و زيادة كفاءة حوض التعقيم. اثبتت هذة الدراسة فعالية النموذج الرياضي المستخدم في هذة الدراسة لتصميم محطات معالجة مياه الصرف الصحي.

Keywords

contact tank --- CFD --- RTD --- SolarBee mixer --- tracer --- wastewater


Article
Optimization of the Horizontal Sedimentation Tank to Predict Turbidity Removal Efficiency in Water Treatment Plant in Iraq

Authors: Ali. Hadi . Ghawi --- Yaser. Ibrahim. Jasem ياسر ابراهيم جاسم
Journal: DIYALA JOURNAL OF ENGINEERING SCIENCES مجلة ديالى للعلوم الهندسية ISSN: 19998716/26166909 Year: 2018 Volume: 11 Issue: 1 Pages: 33-37
Publisher: Diyala University جامعة ديالى

Loading...
Loading...
Abstract

The goal of this research was to design and evaluate the efficiency of horizontal sedimentation tank for water treatment using different position of baffles. Turbid water was treated using alum in the condition with and without baffle in the settling unit. Turbidity was the main determinant in assessing the effectiveness of the settling tank processes. Visualization and profiling research was done using a dye tracer. Samples were collection at different baffle horizontal and vertical height, different flow rates and turbidity with respect to time. Baffle position was found to be capable of increasing turbidity removal efficiency considerably in the settling tank by diminishing the surface loading rate and increasing the retention time. Simulation displayed that turbidity can be eliminated higher than 95%. The type of water purified using optimum position of baffle was well below the WHO guideline for drinking water of <5 NTU.


Article
ESTIMATION OF RESIDENCE TIME IN KHOR ABDULLA AND KHOR AL-ZUBAIR NORTHWEST OF ARABIAN GULF, USING NUMERICAL MODELING TECHNIQUE

Authors: NOORI H. N. AL-HASHIMI --- SAMER A. R. ALTAEI --- ALI A. LAFTA
Journal: Journal of Basrah Researches (Sciences) مجلة ابحاث البصرة ( العلميات) ISSN: 18172695 Year: 2019 Volume: 45 Issue: 2A Pages: 202-216
Publisher: Basrah University جامعة البصرة

Loading...
Loading...
Abstract

A two dimensional depth-average hydrodynamic model that combined with a transport model was applied to study the hydrodynamic characteristics and residence time distribution in Khor Abdulla and Khor Al-Zubair which locate in the northwest of Arabian Gulf. The model was run for two months with a time step of 5 sec. The model results of water level and flow velocities were in a good agreement with measurements. The result of simulations and measurements indicate that there are asymmetries in the tidal wave that propagates farther in inland direction with a gradual increase in their amplitude and hence in its tidal range. The results indicate that residence time in the study area is a site-specific, and show a heterogeneous distribution. However, the longest residence time is observed in two sites, UMR1 with 12 days and KZL with residence time that exceeds 25 days. The data provide useful information and will be significant in the future assessments of coastal developments in this region.


Article
INTERNET OF THINGS ARCHITECTURE BASED CLOUD FOR HEALTHCARE
إنترنت الأشياء التي تعتمد على سحابة للهندسة المعمارية

Loading...
Loading...
Abstract

The Internet of Things (IoT) contains smart devices placed in different environments, connectedwith each other across networks and Internet. The integration between Things and Cloud Computing (CC) formonitoring and permanent storage is required for future IoT applications. Therefore, this paper proposes IoTarchitecture based Cloud for healthcare network when patients are remotely monitored by their family andphysicians. This proposed architecture is different from the traditional IoT architecture that consists of Things,getaways, middleware, and application layers which in turn need connectivity insurance between them. Theproposed architecture is designed and configured using Cisco Packet Tracer version 7.0 over two sites: Site 'A'located at smart home and site 'B' located at the smart hospital. The results show that the IoT based Cloudenhances the patient life style by using smart sensors and mobile application, as well as the physicians canremotely monitor the data in real time.

إنترنت الأشياء (IoT) يحتوي على الأجهزة الذكية وضعت في بيئات مختلفة، متصلةمع بعضها البعض عبر الشبكات والإنترنت. التكامل بين الأشياء والحوسبة السحابية (CC) لـمطلوب الرصد والتخزين الدائم لتطبيقات إنترنت الأشياء في المستقبل. لذلك، تقترح هذه الورقة إنترنت الأشياءالهندسة المعمارية القائمة سحابة لشبكة الرعاية الصحية عندما يتم رصد المرضى عن بعد من قبل أسرهم والاطباء. يختلف هذا الهيكل المقترح عن الهندسة المعمارية التقليدية لإنترنت الأشياء التي تتكون من الأشياء،المهربات، الوسيطة، وطبقات التطبيق التي بدورها تحتاج إلى تأمين الاتصال بينهما. تم التم تصميم الهندسة المعمارية المقترحة وتكوينها باستخدام الإصدار 7.0 من Cisco Packet Tracer عبر موقعين: الموقع 'A'يقع في المنزل الذكي وموقع 'B' يقع في المستشفى الذكي. تظهر النتائج أن سحابة المستندة إلى إنترنت الأشياءيعزز نمط حياة المريض باستخدام أجهزة الاستشعار الذكية وتطبيق المحمول، فضلا عن الأطباء يمكنمراقبة البيانات عن بعد في الوقت الحقيقي.

Listing 1 - 5 of 5
Sort by
Narrow your search

Resource type

article (5)


Language

English (5)


Year
From To Submit

2019 (1)

2018 (2)

2012 (2)