IMPROVING TRANSIENT STABILITY IN CASE OF FAULTS IN HADITHA-QASIM LINE
تحسين الاستقرارية العابرة في حالة الخلل في خط حديثة – ألقائم

Author: Samir S. Mustafa سمير سعدون مصطفى
Journal: Al-Qadisiyah Journal for Engineering Sciences مجلة القادسية للعلوم الهندسية ISSN: 19984456 Year: 2009 Volume: 2 Issue: 2 Pages: 477-485
Publisher: Al-Qadisiyah University جامعة القادسية

Loading...
Loading...
Abstract

Iraqi National Super Grid suffers from out of synchronism of the system due to short circuit in the lines. The main goal of this work is to study the effect of optimum generation and reconfiguration of some transmission paths on transient stability improvement for Iraqi Network in case of short circuit in Haditha-Qaim line because it is one of the wrest lines. A programmable package build under Matlab5.3 was used to determine synchronous machines rotor angles as an indicator of transient stability. Sad Al-Mosul, Haditha and Nasiriya power plant were chosen to notice the situation of stability.

تعاني شبكة الضغط الفائق في العراق من مشكلة خروج المنظومة عن التزامن وذلك عند حدوث دائرة قصر في احد خطوط الشبكة. يهدف هذا البحث إلى دراسة تأثير التوليد الأمثل وتأثير إعادة تشكيل بعض مسارات الخطوط في تحسين الاستقرارية العابرة في شبكة الضغط الفائق وذلك عند حدوث دائرة قصر في خط حديثة – القائم لأنه يعتبر أحد أضعف الخطوط في المنظومة. تم استخدام برنامج جاهز بلغة Matlab5.3 لحساب زوايا دوار المكائن التزامنية كمؤشر لحالة الاستقرارية.تم اختيار محطات توليد سد الموصل, حديثة و الناصرية لملاحظة أستقرارية المنظومة.


Article
THE APPLICATION OF PROGRAMMING FAST METHOD FOR CALCULATION THE CRITICAL CLEARING TIME IN TRANSIENT STABILITY ANALYSIS OF IRAQ SUPER GRID
تطبيق طريقة برمجية سريعة لحساب وقت الازالة الحرج في تحليل الاستقرارية العابرة لشبكة الجهد الفائق العراقية

Authors: Majli Nema Hawas مجلي نعمة حواس --- Maitham Ali Naji ميثم علي ناجي --- Arwa Amer Abdul Kareem أروى عامر عبد الكريم
Journal: AL-TAQANI مجلة التقني ISSN: 1818653X Year: 2014 Volume: 27 Issue: 4 Pages: E1-E21
Publisher: Foundation of technical education هيئة التعليم التقني

Loading...
Loading...
Abstract

A transmission line trip during a power swing may cause instability of a power system. It is necessary to recognize the power swing from fault based on stability boundary, the power swing blocking relays must be set to do that, power swing should be analyzed, a way of probability of occurrence of fault must be found, the critical condition under which the stability of a power system hasn’t been disturbed is recognized & finally the settings of the power swing relays are calculated. The main aim of this paper is to reduce the execution time of the process of finding of the Critical Clearing Time (CCT) using Programming Fast Method (PFM) and compare it with Bisection Method. In practice however, calculating the CCT is computationally inefficient and not desirable because the Bisection method is a tedious and inefficient process. A proposed method for finding the CCT of the power system at any direct fault or indirect-fault is more efficient method in the accuracy & solution time to calculate (CCT) in transient stability analysis. The results obtain by Bisection and proposed methods show that the proposed method reduce the execution time of the CPU about 8-10 times.In this paper the CCT was calculated for two power systems (single machine and the Iraq Super Grid at 10 locations in the Iraqi transmission line network) by using Bisection & proposed methods.MATLAB version 7 is used to implement several programs for the optimal execution time of the CPU time, with using PC4 and CPU speed 3 GHz.

في نظام القدرة الكهربائية اي قطع او عطل في منظومة القدرة خلال تارجح الماكنة قد يسبب حالة عدم استقرار في نظام القدرة لذلك يكون من الضروري تمييز نظام القدرة خلال حدوث العطل ويتم ذلك عن طريق اجهزة حماية هذه الانظمة لايجاد طريقة افتراضية لحدوث العطل وتحديد الظروف الحرجة لأستقرارية منظومة القدرة وحسابات تارجح النظام.ان الهدف الرئيسي من هذا البحث هو تقليل زمن الانجاز الازم لايجاد زمن الازالة الحرج في وحدة المعالجة المركزية بواسطة طريقة البرمجة السريعة ومقارنتها بطريقة التنصيف. عمليا ,تكون طريقة التنصيف غير مرغوب فيها وتكون غير فعالة وشاقة جدا اما الطريقة المقترحة في عملية ايجاد زمن الازالة الحرج عند اي عطل مباشر او غير مباشر فوجد انها اكثر فاعلية من ناحية الدقة وزمن الحل لتقييم استقرارية القدرة.تشير النتائج المستحصلة بالطريقتين الى تفوق الطريقة المقترحة على طريقة تنصيف الزمن. حيث وجد انها تقلل زمن الانجاز في وحدة المعالجة المركزية بمقدار يتراوح بين 8 – 10 مرات. في هذا البحث تم حساب زمن الازالة الحرج لمنظومتين اختباريتين (الماكنة الاحادية و10 موقع لشبكة الجهد الفائق العراقية) بواسطة تطبيق طريقة التنصيف والطريقة المقترحة وذلك باستخدام برنامج الماتلاب (اصدار 7) وحاسبة بانتيوم 4 وسرعة المعالج 3 ميغا هيرتز.


Article
Reduction Reactive Power and Collapse Voltage Using Series Capacitors Compensation in Sudden Change Loads of Transmission Lines
تقليل القدرة المفاعلية وانهيار الفولتية باستخدام تعويض المتسعات المتوالية في حالة تغير الاحمال المفاجئة في خطوط النقل

Author: Hussein Thani Rishag
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2012 Volume: 30 Issue: 5 Pages: 897-919
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

The continuous increase of disturbances on the interconnected electric power system resulting in its inability to reliably meet demands. This paper presents an application of a series capacitor compensation in transmission line and shunt reactors. Wherever all inductive loads required two kinds of power to operate with active power (P) and reactive power (Q) in design and operation of alternating current electric power systems. There is an important interrelation between reactive power and voltage of electrical power systemwhich depends on losses compensation using series capacitors compensation. The reactive power losses in power system distribution can be reduced by connect series capacitors and shunt reactors with transmission lines. From noticing the location of reactive power control in distribution substation we can see the reactive power, seriescapacitors and shunt reactors, economical considerations which are effected on selection of using apparatus and equipments in power stations. Certain switching conditions of circuit breakers of electric power systems can result very high transient recovery voltagescomparing with its normal conditions of working. Using Metal-oxide varistor (MOV) and shunt reactors helping on damping high voltages and return systems to its normal state. The paper describes how can we design and implement series capacitors compensation to solve problem working of reactive power and collapse voltage in transmission lines using simulation methods.


Article
METHODS OF IMPROVING PERFOMANCE FOR ELECTRICAL POWER SYSTEMS IN IRAQ
طرق تحسين أداء أنظمة القدرة الكهربائية في العراق

Author: . ALI A. AL RAZZAQ AL - TAHIR
Journal: journal of kerbala university مجلة جامعة كربلاء ISSN: 18130410 Year: 2008 Volume: 6 Issue: 4 Pages: 14-32
Publisher: Kerbala University جامعة كربلاء

Loading...
Loading...
Abstract

The main purpose in this paper to improve the performance of the electrical power systems in Iraq being developed and thereby add to its value. In recent years, performance evaluation and analysis have become increasingly for any kind of projects and for both personal and equipments safety assessment. This paper presents efficient practical methods for performance improvement and enhancement based on scientific and practical fundamentals. Power stations play important role in performance calculations, the station elements are important factors in improving the quality and security of a power system taking into account the economic problems. Failures originating within a station can create significant electrical power system disturbances. Redundancy principle can be resulted in increasing design complexity through difficult in load distribution equally between redundant systems and increased costs through additional weight and space. Full benefit is resulting of studying the connection bus-bar scheme, if the incoming and outgoing circuits are distributed evenly on the sections of bus - bars. The main reasons for grounding the neutral points to limit over voltages, different types of ground fault currents and to permit the application of suitable ground fault relaying. Transient stability enhancement is the fold of transient stability object that means suggestion of various enhancing methods to improve or augment electrical power system transient stability. Programs and graphics are executed using MATLAB Vol . 7 and Excel programs.

أن الهدف الأساسي لهذا البحث هولتحسين الأداء أنظمة القدرة الكهربائية في العراق لكي يكون متُطَوَّراً وهذا يُضيفُ إِلى قيمتها. في السنوات الأخيرة لقد أَصْبَحَت دراسة وتحليل الأداء تزداد لأي نوعِ من المشاريعِ ولكلا الحسابات الشّخصيِة وتقييمِ سلامةِ الأجهزِة .يقدم هذا البحث طرقِ كفوءةِ وعملية لتحسينِ وتعزيز الأداء مستندة على قواعدِ وأسس علمية وعمليةِ. إن محطات القدرة الكهربائية تَلْعبُ دورَ مهمَ في حسابات الأداء وأن عناصر المحطةِ هي عواملُ مهمةُ في تَحسينِ الجودة وأمن منظومِة القدرةِ أْخذُين في الحسبان ا لمشاكلَ الاقتصادية وأن الفشل الناجمُ ضمن أي محطةَ يُمكنُ أَنْ تَخْلقَ اضطرابات هامّةَ في منظومة القدرة الكهربائية .أن مبدأ التعددية قد تؤدي إلى زّياده في تعقيدِ التّصميمِ من خلال الصّعوبِة في توزيعِ الأحمالِ بشكل منتظم بين الأنظمةِ المتعددة وبالتالي زيادةِ الكلفِة و كذلك زيادةِ الوزن وحيز الفضاء والمساحة المشغولة.هنالك فائدة كبرى من دراسة تأثير نسق قضبان التوصيل على الأداء تتحقق إذا كانت الدّوائرَ الداخلةَ و الـخارجةَ تُوزّعُ بانتظام على مقاطعِ القضبان في مختلف أنواعها. أن الأسباب الرّئيسية لتأريض نقطة التعادل هو لتقيد ارتفاع الفولطياتِ ولتقيد مختلف أنواع الأعطال بسبب ارتفاع أو أنخفاض التيارات ولأختيار المرحل المناسب لتشخيص أعطال التأريض المختلفة.أن تعزيز الأستقرارِية العابرة تهدف الى أقتراح طرقَ مختلفة لتحسين الأستقرارية العابرة لمنظومة القدرةَ الكهربائية. البرامج والرُسوماتِ في هذا البحث نفذت بأستخدام الحزمة البرمجية مختبر المصفوفات الأصدار السابع وبرنامج أكسل.


Article
Using Power System Stabilizers (Pss) And Shunt Static Var Compensator (Svc) For Damping Oscillations In Electrical Power System
أستخدام موازن نظام القدرة (PSS) والمعوضات الساكنة المتوازية (SVC) لإخماد التذبذبات في منظومة القدرة الكهربائية

Author: Hussein Thani Rishag حسين ثاني رشك
Journal: Journal of Al-Ma'moon College مجلة كلية المأمون ISSN: 19924453 Year: 2012 Issue: 19-E Pages: 57-76
Publisher: AlMamon University College كلية المامون الجامعة

Loading...
Loading...
Abstract

The power system stabilizer (PSS) is a control device provides a maximum power transfer and optimal power system stability. PSS has been widely used to damp electromechanical oscillations that occur in power systems due to disturbances. If no adequate damping is available, the oscillation will increase result in instability case. Shunt static var compensator (SVC) is also used to improve system stability because of its role in decreasing the reactive power in electrical transmission lines. This paper presents an application of (SVC) in electrical transmission lines and PSS in two areas, two generator test power system. Using mat lab software to design and implements control system and study the effect of damping oscillations in stability power system after proposed faults in transmission lines of research model that used (PSS - generic & multiband) types and automatic voltage regulator (AVR).

يعتبر موازن نظام القدرة (PSS) احد اجهزة السيطرة التي تجهز منظومة القدرة بأعظم قدرة نقل واستقرارية مثالية لنظام القدرة. يستخدم موازن نظام القدرة (PSS) بنطاق واسع لإخماد التذبذبات الكهروميكانيكية التي تحدث في نظام القدرة بسبب الاضطرابات وإذا لم يتوفر نظام اخماد في المنظومة فان التذبذبات سوف تزداد مما يقود النظام الى حالة عدم الاستقرارية. كذلك تستخدم المعوضات الساكنة المتوازية (SVC) لزيادة استقرارية النظام بسبب دورها في تقليل القدرة المفاعلية الموجودة في خطوط النقل الكهربائية.يقدم البحث الحالي تطبيق المعوضات الساكنة المتوازية (SVC) في خطوط النقل الكهربائية وموازن نظام القدرة (PSS) في نظام سيطرة المولد لمنطقتي عمل ومولدي اختبار نظام القدرة، استخدم برنامج ماتلاب لتصميم وتنفيد نظام ودراسة تاثير اخماد التذبذبات في استقرارية نظام القدرة بعد افتراض اعطال في خطوط النقل موديل البحث الذي يستخدم سيطرة موازن نظام القدرة العام والمتعدد (PSS - generic & multiband) وسيطرة تنظيم الفوليتة (AVR).