AN EXPERIMENTAL STUDY ON A VAPOR COMPRESSION REFRIGERATION CYCLE BY ADDING INTERNAL HEAT EXCHANGER
دراسة عملية لدورة التثليج الأنضغاطية بإضافة مبادل حراري داخلي

Author: Muhammad Asmail Eleiwi
Journal: Tikrit Journal of Engineering Sciences مجلة تكريت للعلوم الهندسية ISSN: 1813162X 23127589 Year: 2008 Volume: 15 Issue: 4 Pages: 63-78
Publisher: Tikrit University جامعة تكريت

Loading...
Loading...
Abstract

This paper presents practical study to improve the indication COP of a vapor compression refrigeration cycle in instrumented automobile air conditioner by designing internal heat exchanger and installing it in the vapor compression refrigeration cycle. Two cases of vapor compression refrigeration cycle were taken in this paper: the first case is that the vapor compression refrigeration cycle without internal heat exchanger and in the second case the vapor compression refrigeration cycle with heat exchanger ; in these two cases, the temperature at each point of a vapor compression refrigeration cycle, the low and the high pressure ,the indoor temperature and the outdoor temperature were measured at each time at compressor speed 1450 rpm and 2900 rpm for each blower speed 1, blower speed 2 and blower speed 3.The refrigerant fluid was used in the vapor compression refrigeration cycle without IHE and with IHE is R134a..

أن هذا ا البحث يقدم دراسة عملية لتحسين معامل أداء منظومة التثليج الأنضغاطبة لجهاز تكيف سيارة بتصميم مبادل حراري داخلي وتنصيبة في دورة التثليج ألأنضغاطية.حالتان تم ألأخذ بها في دورة التثليج ألأنضغاطية, الحالة ألأولى هي دورة التثليج ألأنضغاطية بدون إضافة مبادل حراري والحالة الثانية هي دورة التثليج الأنضغاطية بإضافة مبادل حراري داخلي ; في تلك الحالتين سيتم قياس درجة الحرارة عند كل نقطة من دورة التثليج ألأنضغاطية وفي كل وقت ,الضغط العالي والضغط الواطئ سيتم قياسهم عند كل وقت, درجة الحرارة داخل الغرفة ودرجة الحرارة خارج الغرفة سيتم قياسهم عند كتل وقت أيضا عند سرعة 1450rpm و2900rpm للكومبريسر لسرعة بلور 1 , سرعة بلور 2 وسرعة بلور 3.مائع التبريد المستخدم في دورة التثليج ألأنضغاطية بدون المبادل الحراري الداخلي ومع المبادل الحراري الداخلي هو R134a.


Article
Evaluation of low GWP refrigerants as alternatives for R134a in a vapor compression refrigeration cycle under varying operating conditions

Authors: Qusay Rasheed Al-Amir --- Mousa Mustafa Waes
Journal: Journal of University of Babylon مجلة جامعة بابل ISSN: 19920652 23128135 Year: 2017 Volume: 25 Issue: 1 Pages: 346-359
Publisher: Babylon University جامعة بابل

Loading...
Loading...
Abstract

The present work is a numerical comparative study for low GWP refrigerants based on R161, R152a, R1234ze(e) and R1234yf as a substitute for R134a in a vapor compression refrigeration cycle under varying operating conditions. A computational model is developed by engineering equation solver software (EES). The effects of degree of subcooling, superheating, evaporating and condensing temperatures on the main performance parameters in term of mass flow rate of refrigerant, pressure ratio, volumetric cooling capacity, compressor input power and coefficient of performance are computed for selected refrigerants. The performance results are compared with respect to R134a. The results indicated that the coefficient of performance for R152a is slightly better than the other refrigerants under various operating conditions. The refrigerant R1234ze(e) has approximately the same COP and VCC of R134a and it has the lowest compressor input power and TEWI value over the four compared low GWP refrigerants.

البحث الحالي هو دراسة عددية لمقارنة اداء موائع التثليج ذات احتباس حراري منخفض مثل R1234yf, R152a, R161 و R1234ze(e) كبدائل لمائع التثليج R134a بدورة التثليج الانضغاطية البخارية عند درجات حرارة التشغلية مختلفة. تم اجراء الحسابات باستخدام برنامج ( (EES لمحاكاة منظومات التثليج ولموائع التثليج المختارة . إنّ الهدفَ الأساسي للدراسةِ الحاليةِ هو دراسة تأثيرمختلف الشروط التشغلية مثل درحات حرارة التبريد الفائق و التحميص و درجات المبخر والمكثف على متغيرات أداءِ الدورةَ والتي هي الكتلة الجريانية لمائع التثليج ومعامل الاداء وسعة التثليج الحجمية و قدرة الضاغط. كذلك تم مقارنة متغيرات الاداء لهذه الموائع مع متغيرات الاداء لمائع التثليج R134a. النتائج بينت ان معامل اداء لمائع R152a اعلى بقليل اذا ما قورن ببقية الموائع الاخرى عند مختلف درجات حرارة التشغلية. كذلك بينت النتائج ان المائع R1234ze(e) يملك معامل اداء و سعة تثليج حجمية مشابهة لمائع التثليج R134a بينما يمتلك من جهة اخرى اوطا قدرة داخلة للضاغط و كذلك اوطا التأثير الحراري المكافئ الكليّ( (TEWI مقارنة ببقية الموائع.الكلمات المفتاحية : - موائع ذات احتباس حراري منخفض,دورة التثليج الانضغاطية البخارية, الشروط التشغلية, متغيرات الاداء الرئيسية, التأثير الحراري المكافئ الكليّ.