Article
Enhancement the Performance of Condenser of Split Type Air Conditioning System by Using Evaporative Cooling
تحسين أداء مكثف منظومة تبريد نوع سبلت باستخدام تبريد تبخيري

Author: Lina Ismail Jassim لينا إسماعيل جاسم
Journal: Al-Ma'mon College Journal مجلة كلية المامون ISSN: 19924453 Year: 2011 Issue: 17 Pages: 230-246
Publisher: AlMamon University College كلية المامون الجامعة

Loading...
Loading...
Abstract

The reduction of energy demand is a major concern in areas with very hot weather conditions about 50Co. This can be achieved by using more energy efficient equipment. Evaporative cooling provides a low cost, energy efficient and environmental friendly alternative to traditional Air Conditioning. In this study, a simple design of applying indirect evaporative cooling which investigated experimentally to improve the coefficient of performance of split unit and power consumption. This model consists of a cooling pad behind condenser and injected water on it to reduce air temperature before it passes over the condenser. The experimental results show that the coefficient of performance increases by about 73% and the power consumption decreases by about 18%.

يتضمن هذا البحث، تصميم نموذج عملي لتحسين اداء منظومة التبريد، والتقليل من استهلاك الطاقة الكهربائية خاصة في المناطق ذات الدرجة الحرارية العالية، والتي تصل إلى حوالي 50 درجة مئوية وذلك باستخدام التبريد التبخيري. ان النموذج المستخدم يتضمن وسيط تبريد تبخيري, وهو مادة الحلفة بشكل يشبه تصميم المكثف الخاص بالسبلت، موضوعة خلف المكثف لتبريد الهواء قبل مروره على ملف المكثف، وحوض ماء ومضخة صغيرة وانابيب توصيل الماء. علما ان النتائج العملية تشير الى زيادة في معامل اداء المنظومة بنسبة 73% وانخفاض باستهلاك الطاقة الكهربائية بنسبة 18%.


Article
Life-Cycle Cost Analysis for Three Different Types of A/C Systems Applied on an Apartment Located in a Multi-Floors Residential Tower in Mosul City
تحليل كلفة العمر الافتراضي لثلاث منظومات مختلفة لتبريد وتكييف الهواء لشقة متواجدة في برج سكني متعدد الطوابق في مدينة الموصل

Author: Badran Mohammed Salim
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2014 Volume: 32 Issue: 9 Part (A) Engineering Pages: 2134-1147
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

This research studies the life cycle cost analysis using detailed cooling and electrical load profiles to calculate initial and running costs to evaluate the economic feasibilities of three different types of air conditioning systems as residential air conditioning system (RACs), commercial air conditioning system (CACs) and multi power air conditioning system (MPACs). The present-worth cost method for life-cycle cost period for ten (10) years analysis is applied to a sample building located in Mosul city / Iraq so as to select the best air conditioning system. The cooling load temperature differential with cooling load factor (CLTD/CLF) was used with hourly analysis program (HAP v4.6) for the estimation cooling load in each room of apartment.The results showed that the RAC system is lower than CAC and MPAC systems in initial cost approximately 53% and 67% respectively and the running cost for CAC system is lower than RAC and MPAC systems approximately 12% and 7% respectively for one month. The the total cost for two systems RAC and CAC are equal after 20 months of the beginning run and after even break point (BEP) the total cost for CAC system began to decline which indicates there is save in electric consumption and present worth cost over a period of (10) ten years after operation interval. The CAC system uses duct always to distribute air into each condition zone, therefor this system gives less noise of air distribution with best interior aesthetic appearance so that it fits with the interior decoration for each rooms of apartment. The outdoor unit of CAC system doesn’t appearance because the system working for long distances and can put outdoor units on the roof of the building.

يتضمن البحث الحالي تحليل كلفة العمر الافتراضي لثلاث منظومات مختلفة لتبريد وتكييف الهواء وكانت على النحو التالي منظومة تبريد وتكييف منزلية ومنظومة تبريد وتكييف تجارية ومنظومة تبريد وتكييف متعددة الاحمال حيث تم دراسة الكلفة الاولية والكلفة التشغيلية للمنظومات المختلفة بالاعتماد على مخطط الاحمال الحرارية والاحمال الكهربائية لنموذج شقة سكنية تقع في برج متعدد الطوابق في مدينة الموصل / العراق ، تم أعتماد طريقة فرق درجات حرارة مع عامل تصحيح حمل التبريد (CLTD/CLF) وبرنامج تحليل الساعات (HAP) أصدار (4.6) من شركة كاريير لحساب احمال التبريد الخاصة بالشقة السكنية. تم ملاحظة أن منظومة التبريد والتكييف المنزلية (RACs) تكون كلفتها الاولية اقل بمقدار 53% عن منظومة التبريد والتكييف التجارية (CACs) و67% عن منظومة التبريد والتكييف متعددة الاحمال (MPACs) وأن الكلفة التشغيلية لمدة شهر واحد فقط لمنظومة التبريد والتكييف التجارية هي أقـل من منظومة التبريد والتكييف المنزلية ومنظومة التبريد والتكييف متعددة الاحمال بمقدار 7% و 12% على التوالي، كذلك تم استنتاج أن منظومة التبريد والتكييف التجارية هي أفضل من ناحية الكلفة الكلية (المتمثلة بالكلفة الاولية والتشغيلية) لمدة تشغيلية مقدارها (10) عشر سنوات وأنه بعد مرور ((20 شهر من التشغيل الاولي للمنظومات الثلاث سيحدث تطابق في قيم الكلف الكلية لمنظومتي التبريد والتكييف التجارية والمنزلية وبعد تجاوز نقطة التطابق (EBP) سيتم عمل منظومة التبريد والتكييف التجارية مع ربح من ناحية الكلفة التشغيلية على مدار السنوات المتعاقبة وهذا يمثل الربح في اختيار هذا النوع من المنظومات الثلاث، فضلا عن ان منظومة التبريد والتكييف التجارية تستخدم مجرى هوائي دائماً لتمرير الهواء من الوحدة الداخلية وصولاً الى الحيز المراد تكييفه وبالتالي سيتم التحكم من خلال تصميم المجرى الهوائي بمقدار الضوضاء التي يصدرها الهواء الخارج من موزع الهواء لكل حيز مع وجود تناسق كبير بين اشكال والوان موزعات الهواء التي ستكون ملائمة مع التصميم الداخلي لكل حيز. إن منظومة التبريد والتكييف التجارية (CACs) تعمل لمسافات طويلة وبذلك سيكون من السهل جداً وضع الوحدة الخارجية على سطح البرج السكني وبالتالي المحافظة على المظهر الخارجي للبرج السكني .


Article
Economic Feasibility Study of Modern and Conventional Central Heating Systems for Villa Located in Duhok City, Iraq

Authors: B.M. Salim --- I.F. Abdulqadir --- F.M. Younis
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2017 Volume: 35 Issue: 7 Part (A) Engineering Pages: 725-736
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

This research includes the evaluation of economic feasibilities based on the Iraqi’s market cost by using three different types of central heating systems in a residential villa located in Duhok city / Iraq. It also compares between modern and conventional central heating systems. A life cycle cost analysis based on detailed heating and operation load profiles considered in this work. Initial, running and maintenance costs for three central heating systems examined for fifteen years as a working period. The used systems in this study were; modern central heating system (heat pump water heater system) and conventional central heating system (fuel oil hot water boiler system and electric hot water boiler system). Transfer function method with hourly analysis program platform (HAP4.9) used for estimation the heating loads within each zone of the project. The proposed technique of modern central heating system found to be more efficient for thermal and economic efficiencies and it uses an environmentally friendly refrigerant such as (R410A). It also works efficiently in severe cold climate with low temperature of (-20°C) in winter season. The results shows that the heat pump water heater central heating system is most efficient system, this system has provided an energy saving range up to 57.5% compared with electric hot water boiler system and 70.6% compared with fuel oil hot water boiler system.


Article
Solar Energy Utilization Instead of Oil Energy
إستغلال الطاقة الشمسیة بدل الطاقة النفطیة

Authors: S. A. Salman --- F. L. Rashed --- I. G. Faiadh*
Journal: Diyala Journal For Pure Science مجلة ديالى للعلوم الصرفة ISSN: 83732222 25189255 Year: 2012 Volume: 8 Issue: 2 Pages: 108-117
Publisher: Diyala University جامعة ديالى

Loading...
Loading...
Abstract

In this work solar collector had been used as thermal collector for old oil systemrefrigerator driven by oil (spent gas) after developing it’s diffusion-absorption hest pump.Glycerin liquid boiling 290 °C was used instead of water in the pipe which surround the,generator with a pipe of 30 cm height and 5 cm in diameter. The ammonia vapor generator atfluid temperature of 140 °C up to 190 °C where the pipe near the condenser become hot, thismean that the ammonia vapor generator up to the condenser.The requirement calculation were performance for this work are the volume of storage hotfluid required to operate the refrigerator for one day, the flow rate required to supply heatinput to generator, and the solar collector absorber area.

في ھذا العمل، تم إستخدام خلیة شمسیة كمجمع حراري لمنظومة نفطیة تعمل بالنفط بعد تحویر المضخة الحراریةامتصاصیة-انتشاریة لھا.تم إستخدام سائل الكلیسرین بدل الماء في الانبوب المحیط بالمولد ذو درجة غلیان عالیة ٢٩٠ م وبانبوب ذي ارتفاع١٩٠ م. - ٣٠ م وبقطر ٥ سم حیث قد تم تبخر الامونیا بمعدل درجة حرارة ١٤٠ان الحسابات المطلوب انجازھا لھذا العمل ھي كمیة المائع المار مطلوب خلال مدة یوم واحد كامل، وبمعدل جریانالحرارة للمولد وكذلك الحسابات المتعاقة بالمساحة الامتصاصیة للمجمع الشمسي


Article
Modeling and Simulation of Thermal Performance of Solar-Assisted Air Conditioning System under Iraq Climate
تقييم الاداء الحراري لمنظومة تكييف هواء تعمل بمساعدة الطاقة الشمسية في العراق نظًرياً

Authors: Mohammed Abdulhassan Abid Mohammed Abdulhassan Abid محمد عبدالحسن عبد --- Najim Abid Jassim نجم عبد جاسم
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2016 Volume: 22 Issue: 8 Pages: 175-194
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

In Iraq most of the small buildings deployed a conventional air conditioning technology which typically uses electrically driven compressor systems which exhibits several clear disadvantages such as high energy consumption, high electricity at peak loads. In this work a thermal performance of air conditioning system combined with a solar collector is investigated theoretically. The hybrid air conditioner consists of a semi hermetic compressor, water cooled shell and tube condenser, thermal expansion valve and coil with tank evaporator. The theoretical analysis included a simulation for the solar assisted air-conditioning system using EES software to analyze the effect of different parameters on the power consumption of compressor and the performance of system. The results show that refrigeration capacity is increased from 2.7 kW to 4.4kW, as the evaporating temperature increased from 3 to 18 ºC. Also the power consumption is increased from 0.89 kW to 1.08 kW. So the COP of the system is increased from 3.068 to 4.117. The power consumption is increased from 0.897 kW to 1.031 kW as the condensing temperature increased from 35 ºC to 45 ºC. While the COP is decreased from 3.89 to 3.1. The power consumption is decreased from 1.05 kW to 0.7kW as the solar radiation intensity increased from 300 W/m2 to 1000 W/m2, while the COP is increased from 3.15 to 4.8. A comparison between the simulation and available experimental data showed acceptable agreement.

معظم المباني الصغيرة والمتوسطة في العراق تعتمد على انظمة التبريد ذات الضاغط الكهربائي والذي من عيوبه الاستهلاك العالي للطاقة الكهربائية عند حمل الذروة. في هذا العمل تم التحقق نظريا من الاداء الحراري لمنظومة تكييف الهواء المركبة مع مجمع شمسي. يتكون مكيف الهواء الهجين من ضاغط شبه مقفل، مكثف نوع الاسطوانة والانبوب المبرد بالماء، صمام تمدد حراري ومبخر نوع الخزان والملف. شمل التحليل النظري محاكاة لمنظومة تكييف الهواء التي تعمل بمساعدة الطاقة الشمسية باستخدام برنامج EES لتحليل تأثير عوامل مختلفة على استهلاك طاقة الضاغط وأداء المنظومة. بينت النتائج ان سعة التثليج قد زادت من 2,7 الى 4,4 كيلو واط مع زيادة درجة حرارة التبخير من 3 الى 18 درجة مئوية وكذلك فان الطاقة المستهلكة قد زادت من 0.89 الى 1.08 كيلو واط , والذي ادى الى زيادة معامل اداء المنظومة من 3,068 الى4,117. ان الطاقة المستهلكة قد ازدادت من 0,897 الى 1,031 كيلو واط مع زيادة درجة حرارة التكثيف من 35 الى 45 درجة مئوية. بينما معامل الاداء قد انخفض من من 3,89 الى 3,1. ان الطاقة المستهلكة قد انخفضت من 1,05 الى 0,7 كيلو واط عند زيادة الاشعاع الشمسي 300 الى 1000 واطم2, بينما معامل اداء المنظومة قد ازداد من 3,15 الى 4,8. واظهرت المقارنة بين النتائج التجريبية والنظرية اتفاق مقبول بينهما.