research centers


Search results: Found 10

Listing 1 - 10 of 10
Sort by

Article
Influence Of Ambient Temperature On Stiffness Of Asphalt Paving Materials

Authors: Maryam S. Makki --- Hamed M. H
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2011 Volume: 17 Issue: 5 Pages: 1090-1108
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Asphalt pavement properties in Iraq are highly affected by elevated summer air temperatures. One of these properties is stiffness (resilient modulus).To explain the effect of air temperatures on stiffness of asphalt concrete, it is necessary to determine the distribution of temperatures through the pavement asphalt concrete layers. In this study, the distribution of pavement temperatures at three depths (2cm ,7cm, 10cm) below the pavement surface is determined by using the temperature data logger instrument .A relationship for determining pavement temperature as related to depth and air temperature has been suggested. To achieve the objective of this thesis,the prepared specimens have been tested for indirect tension in accordance with ASTM D4123, using the pnuematic repeated load apparatus , in order to determine the values of resilient modulus at three different temperatures (10, 25, 40) ◦C. From results of testing, it is observed that the resilient modulus decreases with increase in test temperature by a rate of 8.78×103 Psi/C˚ for asphalt concrete wearing courses. An increase in optimum asphalt content by 0.1% (by weight of total mixture) causes a decrease in resilient modulus by 22% at a temperature of 40C˚.A statistical model for the prediction of resilient modulus has been developed depending on mixture variables of: asphalt content , asphalt binder viscosity , surface area of combined aggregates , air voids of compacted mixture and test temperature خواص التبليط الاسفلتي في العراق تتأثر بدرجة كبيرة بدرجات حرارة الهواء المرتفعة خلال فصل الصيف.وانه أحد هذه الخواص هو معامل الجساءة و لبيان تأثير درجات حرارة الهواء على معامل الجساءة للخرسانة الاسفلتية فأنه من الضروري تحديد توزيع درجات الحرارة خلال طبقات الخرسانة الاسفلتية للتبليط. في هذه الدراسة توزيع درجات حرارة التبليط على ثلاثة اعماق(2سم ,7سم ,10 سم) تحت سطح التبليط تم تحديده بأستخدام جهاز تسجيل بيانات درجات الحرارة. لقد تم اقتراح علاقة رياضية لتحديد درجة حرارة التبليط نسبة الى العمق ودرجة حرارة الهواء. و لتحقيق الهدف من هذا البحث العينات المحضرة تم فحصها للشد الغير مباشر وفقآ ((ASTM D4123 بأستخدام جهاز الاحمال المتكررة لأيجاد معامل المرونة بثلاث درجات حرارة مختلفة هي 10, 25 ) , (40درجة مئوية.ومن نتائج الفحص لوحظ ان معامل المرونة يتناقص بزيادة درجة حرارة الفحص بنسبة8.78×103 Psi/C˚ للطبقات السطحية للخرسانة الاسفلتية.وأن الزيادة في محتوى الاسفلت المثالي بمقدار 0.1% من وزن الخلطة الكلية يسبب نقصان في معامل المرونة بمقدار22% عند درجة حرارة 40 مئوي.وقد تم تطوير علاقة احصائية لتنبأ معامل المرونة وفقآ لمتغيرات الخلطة الاسفلتية: محتوى الاسفلت ’ لزوجة الاسفلت ’المساحة السطحية للركام ’نسبة الفجوات الهوائية للخلطة المرصوصة ودرجة حرارة الفحص


Article
Ambient Temperature Affect the Pore size of PVA Nanofibers Tissues
تأثير درجة حرارة المحيط على الحجم المسامي لانسجة الياف بولي فينال الكحول النانويه

Authors: Akram R. Jabur --- Laith K. Abbas --- Safa M. Muhi Aldain
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2015 Volume: 33 Issue: 6 Part (B) Scientific Pages: 1040-1047
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

Electrospinning has recently emerged as a leading technique for generating biomimetic scaffolds made of synthetic and natural polymers for tissue engineering applications. PVA was dissolved in distilled water at concentration (10% wt). PVA 10% DW solution was prepared as biopolymeric materials for fabricating tissue engineered scaffolds by electrospinning, varying ambient temperature (25, 30, 35, 40, 45 and 50) ͦ C andinvestigated the ambient temperature effect on tissue nanofibers pore size. Scanning electron microscopy was utilized to profile the topography of individual electrospun fibers. Statistical measurements for each SEM images lead to measure the mean poresize of tissue obtained. Our results indicate that the average poresize of PVA fibertisues could be scaled down to mean values (132-300)nm smooth nanofibers without any beads, poresize decreased as ambient temperature increase to certain temperature at (40 °C) and retrain increasing at (45 and 50) °C temperature. برز البرم الالكتروني حديثا" كتقنية رائده لتخليق سقالات محاكاة بايولوجيا مصنعه من بوليمرات صناعيه او طبيعيه لاستخدامات الهندسة النسيجيه . أذيب بولي فينال الكحول في ماء مقطر بتركيز 10% وزنيا" . حضر بولي فينال الكحول 10% من الماء المقطر كماده سائل بوليمر احيائي لتصنيع سقالات هنسة نسيجيه بالبرم الالكتروني , وبتغيير درجات حرارة المحيط (45,40,35,30,25 و( 50 ͦم° ودراسة تأثير تغيير درجة حرارة المحيط على حجم المسامي للانسجه الليفيه النانويه.أستخدم فحص المجهر الالكتروني الماسح لتحديد شكل وطوبوغرافية الالياف المبرمه الكترونيا .واجريت حسابات احصائيه من كل صور من صور المجهر الالكتروني الماسح المأخوذه للالياف لتحديد معدل حجم المسامات للنسيج المحضر والمفحوص . النتائج التي تم الحصول عليها تدل على أن معدل حجم المسامات للالياف أنسجه بولي فينال الكحول يمكن أن تتدرج الى قيمه ممتده بين (132-300) نانومتر لالياف ملساء دون حصول اي عقد , والحجم المسامي يتناقص بزيادة درجة حرارة المحيطه الى درجه حراره معينه هي 40 م° والتي بعدها يعود للتزايد عند درجات حراره (50, 45) م°.


Article
Effects of Ambient Temperature and Needle to Collector Distance on PVA Nanofibers Diameter Obtained From Electrospinning Technique

Authors: A.R. Jabur --- L.K. Abbas --- S.M. Muhi Aldain
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2017 Volume: 35 Issue: 4 Part (A) Engineering Pages: 340-347
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

Electro spinning is regarded as an active technique for producing biomimetic scaffolds used in tissue engineering applications from synthetic and natural polymers. The technique used in this research gives the ability to produce bio-polymeric materials for fabricating engineered scaffold tissues by preparing (PVA) solution. Ambient temperature at (25, 30, 35, 40, 45 and 50 °C) and needle tip to collector distance with (4, 8, 12, 15, 20 and 22 cm) were studied to optimize the electrospun fibers (size and shape). The electrospun fibers topography were studied by scanning electron microscopy (SEM). Measurements were done for each (SEM) images and lead to determine the mean diameters size of the obtained fibers. Results showed that the average fiber diameter of the (PVA) electrospun decreased to the range (220–500 nm) without creation of any beads, fibers diameter decreased as ambient temperature increase to certain temperature at (45 °C) and retrain to increase at (50 °C) temperature, while increasing the distance of the needle tip to collector decrease the mean nanofiber diameter from (875 nm) at (4 cm) to (600 nm) at (22 cm).


Article
COMPARISON OF COOLING LOAD CALCULATION METHODS BY

Author: Khalid A. Joudi
Journal: Al-Fatih journal مجلة الفتح ISSN: 87521996 Year: 2005 Volume: 1 Issue: 24 Pages: 57-61
Publisher: Diyala University جامعة ديالى

Loading...
Loading...
Abstract

The present work includes cooling load measurement in Iraq. One room located in Baqubah was the object of the study. The measurement was taken for the room in summer months of 2004 (i.e. in May, June, July, August & September). The area of test room was 15 m2 and 3 m ceiling height with medium weight construction specifications. The test room includes exterior east and west wall facing, un-conditioning adjacent space with an exterior roof, east window and an exterior west door. The air conditioner unit used in this work was a window type with a nominal capacity of 2 T.R. (7 kW). The theoretical cooling load was predicted by three methods of cooling load calculation, which are TFM, CLTD/SCL/CLF & TETD/TA methods. Measurement of cooling load showed that there is a large difference between the measured and predicted cooling load with all theoretical methods. The difference ranged from 33% to 40%. This large difference is appear because of the several season such as the air conditioner type, suffer environmental and the construction specification of the test room where it’s represent the Iraqi building and not exactly same as building specification tabulated in ASHRAE tables ,يعنى هذا البحث بإجراء قياسات عملية لحساب حمل التبريد في العراق. غرفة الاختبار الواقعة في مدينة بعقوبة كانت مشروع الدراسة حيث أخذت القياسات خلال اشهر الصيف (أيار, حزيران, تموز, آب و أيلول). و كانت مساحة غرفة الاختبار 15م2 مع ارتفاع 3م للسقف مع مواصفات إنشاء ذات تركيب متوسط. تشمل غرفة الاختبار جداران خارجيان أحدهما مواجه للشرق و الآخر مواجه للغرب مع حيز مجاور غير مكيف مع سقف خارجي و كذلك شباك مواجه للشرق و باب خارجية مواجه للغرب. و قد كانت منظومة التكييف التي لتبريد هذه الغرفة تم استخدام وحدة تبريد جدارية سعة 2طن تثليج (7كيلو واط). أجريت الحسابات النظرية لحمل التبريد بثلاث طرق لحساب حمل التبريد و هي طريقة دالات التحويلTFM وطريقة حمل التبريد من فرق درجات الحرارة (CLTD) بالإضافة إلى طريقة فرق درجات الحرارة الكلي المكافئ (TETD). أظهرت النتائج العملية لحسابات حمل التبريد للغرفة أن هناك فرق في الحمل كبير نسبيا بين النتائج العملية و النتائج النظرية و الفرق يتراوح بين 33% إلى 40%.


Article
THE INFLUENCE OF AMBIENT TEMPERATURE ON THE GAS TURBINE POWER PLANT PERFORMANCE
دراسة تاثير درجة حرارة الهواء الجوي على اداء محطة توليد غازية

Authors: Sameer D. Ali --- Saadoon Abdul hafed Jawad --- Salim farman
Journal: DIYALA JOURNAL OF ENGINEERING SCIENCES مجلة ديالى للعلوم الهندسية ISSN: 19998716 Year: 2015 Volume: 8 Issue: 4 Pages: 632-640
Publisher: Diyala University جامعة ديالى

Loading...
Loading...
Abstract

In this paper a computer program is employed to evaluate the performance of a gas turbine power plant at a different ambient temperature. This is very important especially in Iraq, because of the wide range of ambient temperature variation throughout the year. The results show that the thermal efficiency of the plant decreases as the ambient air temperature increases, where the drop in efficiency is significant at higher temperatures, especially in summer season. So, it is very important to use a cooling system to control the ambient temperature for best performance. The study is done on a single shaft, simple cycle gas turbine power plant with maximum output power of 20 MW. في هذا البحث استخدم برنامج حاسوبي لايجاد كفاءة (اداء) محطة توليد كهرباء غازية لمختلف درجات الحرارة للهواء الجوي الداخل الى الضاغطة التي تمثل المرحلة الاولى للمنظومة.وهذا مهم جدا خصوصا في العراق حيث يكون فارق درجات الحرارة للهواء الجوي كبير خلال السنة.لنتائج اظهرت انخفاض واضح في اداء المنظومة بزيادة درجات الحرارة خصوصا في فصل الصيف والتي تمثل مرحلة الذروة للطلب على الطاقة الكهربائية لذلك من المناسب استخدام منظومة تبريد لتبريد الهواء الداخل الى الضاغطة من اجل تحسين الاداء.الدراسة تمت على وحدة توليد بطاقة قصوى (20 MW)، بترتيب محور ,واحد وبدورة بسيطة.


Article
INFLUENCE OF AMBIENT TEMPERATURE ON THE PERFORMANCE OF REPOWERED COMBINED CYCLE POWER PLANT
تأثير درجة حرارة الهواء المحيطة على اداء محطة الطاقة المشتركة

Loading...
Loading...
Abstract

A performance study was conducted on the combined cycle power plant (CCPP), which is one of the most important options for replacement and repowering of the available steam power plant. The thermodynamic performance of these plants depends on the ambient temperature which varies considerably from one season to another. The objective of the current work is to investigate the effects of these variations on the performance of combined cycle power plants. In this study AL-Mussaib thermal power plant has been chosen for repowering, for this purpose, AL-Khairat gas turbines are used and the effect of duct burner is investigated. The repowered combined cycle power plant (RCCPP) consists of four gas turbines and four heat recovery steam generator (HRSG) with one steam turbine was associated with the unit in this model. The theoretical analysis was made according to both first and second laws of thermodynamic analysis. A generalized computer program was prepared by Fortran 90 for this purpose. It is found that the net power output, thermal and exergy efficiencies of the RCCPP increases as the ambient temperature decreases. The mass flow rate of steam decreases with the increase of ambient temperature at constant compressor pressure ratio and turbine inlet temperature (TIT). The exergy destruction in the combustion chamber and HRSG decreases while, the exergy destruction of the condenser increases greatly as the ambient temperature increases اشتمل البحث على دراسة اداء محطة توليد الكهرباء والتي تعمل بنظام الدورة المركبة او المؤتلفة CCPP))والتي تعد واحدة من اهم الخيارات لاستبدال واعادة تأهيل محطة توليد الكهرباء البخارية المتاحة . يعتمد الاداء الثرموديناميكي لهذه المحطات على درجة حرارة الهواء المحيط , والذي يتغير بشكل كبير من فصل الى اخر . وتهدف هذه الورقة الى دراسة تأثير التغير في درجة حرارة الهواء المحيط على اداء هذه المحطات . في هذا البحث تم اختيار محطة المسيب الحرارية لإعادة التأهيل ولهذا الغرض تم استخدام التوربين الغازي لمحطة الخيرات ودراسة تأثير اضافة المحارق الانبوبية ايضا حيث تتكون محطة الطاقة المشتركة او المؤتلفة CCPP)) من اربعة توربينات غازية واربعة مولدات بخار ( HRSG) مع توربين بخاري واحد . تم اجراء التحليل النظري وفقا لقانوني الاول والثاني من قوانين الثرموداينمك . فقد تم اعداد برنامج حاسوبي شامل باستخدام لغة فورتران 90 لهذا الغرض , وجد ان معدل القدرة الناتجة وكلا من الكفاءة الحرارية والمتاحية لمحطة الطاقة المشتركة او المؤتلفة CCPP)) تزداد بزيادة درجة حرارة الهواء المحيطة , ان كتلة البخار تتناقص بزيادة درجة حرارة الهواء المحيط بثبوت كلا من نسبة الانضغاط ودرجة حرارة التوربين الداخلة . ان فواقد كل من غرفة الاحتراق والمولد البخاري ( HRSG) تتناقص بزيادة درجة حرارة المحيط بينما في المكثاف تزداد .


Article
Modeling of Monocrystalline PV Cell Considering Ambient Conditions in Baghdad City
نمذجة الخلية الفوتوفولتائية احاديه الكريستالين أخذين بنظرالأعتبارالظروف الجوية في مدينة بغداد

Authors: Mohammed E. Abd Al-Wahed محمد عماد عبد الواحد --- Osamah F. Abdullateef اسامة فاضل عبد اللطيف
Journal: Al-Khwarizmi Engineering Journal مجلة الخوارزمي الهندسية ISSN: 18181171 23120789 Year: 2017 Volume: 13 Issue: 3 Pages: 74-82
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The environmental conditions are important factors, because they affect both the efficiency of a photovoltaic module and the energy load. This research was carried out experimentally and modeling was done in MATLAB –Simulink by monitoring the variation in power output of the system with environmental conditions such as solar radiation, ambient temperature, wind speed, and humidity of Baghdad city. From the results, the ambient temperatures are inversely proportional to humidity and the output power performance of the system, while the wind speed is directly proportional with the output power performance of the system. الظروف البيئية هي عوامل مهمة، لأنها تؤثر بشكل كبيرعلى كل من كفاءة اللوح الشمسي والطاقة الناتجه. حيث أجري هذا البحث تجريبيا وتمت نمذجة النتائج في برنامج الماتلاب من خلال رصد التغير في انتاج الطاقة من النظام مع الظروف البيئية مثل الإشعاع الشمسي ودرجة حرارة المحيط، وسرعة الرياح، والرطوبة في مدينة بغداد. ومن خلال النتائج وجدنا ان هناك تناسباً عكسياً بين درجة حرارة المحيط وأداء انتاج الطاقة للنظام والرطوبة وأداء انتاج الطاقة للنظام، في حين أن سرعة الرياح تتناسب تناسبا طرديا مع أداء انتاج الطاقة من النظام


Article
Computer Simulation of an Automobile Air-Conditioner with Ambient Temperature Effects
محاكاة باستخدام الحاسوب لمكيف هواء السيارة مع تأثير درجة حرارة المحيط الخارجي

Author: Saad N. Shehab سعد نجيب شهاب
Journal: Al-Ma'mon College Journal مجلة كلية المامون ISSN: 19924453 Year: 2011 Issue: 18-E Pages: 84-99
Publisher: AlMamon University College كلية المامون الجامعة

Loading...
Loading...
Abstract

Theoretical and experimental studies were conducted to analyze and simulate the performance of instrumented automobile air-conditioner , using R134a as a working refrigerant . The experimental work was carried out on an available automobile air-conditioner unit with ambient temperature effects on the cycle performance . A computer program is constructed to analyze , and simulate the working and performance of instrumented automobile air-conditioner with the effect of ambient temperature on the performance of compressor , condenser , condensing unit , evaporator , and complete refrigeration cycle . The experimental performance equations of the compressor , condenser , and evaporator are used in the mathematical simulation . The comparison between the mathematical model and experimental results of refrigeration load , compressor work , condenser load , and coefficient of performance for different ambient temperatures showed a good agreement . أجريت دراسة نظرية وعملية، لتحليل ومحاكاة أداء منظومة تبريد هواء السيارة بأستخدام غاز فريون R134a كمائع تبريد . تم تنفيذ الدراسة العملية على منظومة تبريد هواء السيارة المتوفرة لدرجات حرارية مختلفة للمحيط الخارجي . تم بناء برنامج حاسوبي لتحليل ومحاكاة عمل وأداء جهاز تبريد السيارة، ودراسة تأثير درجة حرارة المحيط الخارجي على الضاغط والمكثف ووحدة التكثيف والمبخر و كامل منظومة التبريد . وقد أستخدمت معادلات أداء الضاغط والمكثف والمبخر المستحصلة بصورة عملية في التحليل الرياضي . أظهرت المقارنة بين نتائج النموذج الرياضي والقيم العملية تطابق جيد لحمل التبريد و شغل الضاغط و حمل المكثف ومعامل الأداء ولدرجات حرارة مختلفة للمحيط الخارجي .


Article
Estimation of Wasted Thermal Energy from Gas Turbine Units in Mosul Power Station
تخمين الطاقة الحرارية المهدورة من الوحدات الغازية في محطة الموصل الغازية

Author: Dr. A. R. Al-Habbo A.Youns Fathi
Journal: Tikrit Journal of Engineering Sciences مجلة تكريت للعلوم الهندسية ISSN: 1813162X 23127589 Year: 2012 Volume: 19 Issue: 2 Pages: 10-17
Publisher: Tikrit University جامعة تكريت

Loading...
Loading...
Abstract

The present study involve a thermal analysis of a gas turbine unit like those which are used in Mosul gas turbine power station in order to estimate the amount of thermal energy is wasted in the exhaust gases. A computer program is developed to investigate the effect of ambient temperature on the performance of the gas turbine unit including the mass flow of air, power output, thermal efficiency, specific fuel consumption, exhaust gas temperature and the amount of wasted thermal energy (Qexh). Results indicate that mass flow of air decreases as the ambient temperature increase; this eventually affected the power out, thermal efficiency and specific fuel consumption. Results show that the power output decrease by 28.5% when the temperature increased from 15 ºC to 45 ºC. However, the temperature of exhaust gases increased by nearly 0.04% as the temperature approach 45 ºC and the thermal energy expelled with exhaust decreased nearly by 0.12%. It also found that the wasted thermal energy nearly twice the produced power output of gas turbine. يتضمن البحث الحالي التحليل الحراري لوحدة غازية مشابهة للوحدات الغازية العاملة في محطة الموصل الغازية لغرض تقييم الطاقة الحرارية المهدورة في غازات العادم. تم بناء برنامج حاسوبي لملاحظة تأثير درجة حرارة الجو على أداء الوحدة الغازية ليشمل كل من كمية الهواء الداخلة والقدرة الناتجة والكفاءة الحرارية و الاستهلاك النوعي للوقود و درجة حرارة غازات العادم وأخيرا الطاقة الحرارية المهدورة .بينت النتائج إن كمية الهواء الداخلة تنخفض بشكل واضح مع ارتفاع درجة حرارة الجو والتي بدورها تؤثر على القدرة المتولدة و الكفاءة الحرارية والاستهلاك النوعي للوقود. حيث لوحظ إن القدرة المتولدة تنخفض تقريبا %28.5 عندما تصل درجة حرارة الجو إلى 45 درجة مئوية، بينما لوحظ إن درجة حرارة غازات العادم تزداد بمقدار % 0.04 في حين وجد إن الطاقة الحرارية المهدورة مع غازات العادم تنخفض بنسبة 12% .كما بينت النتائج على انه هنالك طاقة حرارية كبيرة مفقودة مع غازات العادم والتي قدرت على انه تساوي ثلثي الطاقة الحرارية المجهزة للوحدة الغازية.


Article
Performance Evaluation of Small Scale Air-Conditioning System Using R22 and Alternative Refrigerants
وموائع بديلة R22 أداء منظومة تكييف هواء صغيرة الحجم باستخدام تقييم

Authors: Khalid Ahmed Al-Joudi خالد أحمد الجودي --- Qusay Rasheed Abd Al-Amir قصي رشيد عبد الامير
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2014 Volume: 20 Issue: 1 Pages: 62-77
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

A mathematical model has been formulated to predict the influence of high outdoor air temperature on the performance of small scale air - conditioning system using R22 and alternative refrigerants R290, R407C, R410A. All refrigerants were investigated in the cooling mode operation. The mathematical model results have been validated with experimental data extracted from split type air conditioner of 2 TR capacity. This entailed the construction of an experimental test rig which consists of four main parts. They are, the refrigeration system, psychrometric test facility, measuring instrumentation, and auxiliary systems. The conditioned air was maintained at 25 0C dry bulb and 19 0C wet bulb for all tests. The outdoor ambient air temperature was varied from 35 0C to 55 0C in 5 0C increments. The study showed that R290 is the better replacement for R22 when the air conditioning system works under high ambient temperature. It has better performance as a drop in refrigerant. R407C has the closest performance to R22, followed by R410A. تم بناء نموذج رياضي يحاكي َتأثيرَ ارتفاع درجة حرارة الهواء الخارجي على الأداء التشغيلي لمكيف هواء صغير السعة يعمل بمائع التثليج R22 و بدائله R410A ,R407C, R290 و بطورِ التَبريد. قورنت نتائج النموذج رياضي لهذه الدراسةِ بنتائج عملية من مكيّفِ هواء مُنْفصل سعةِ 2 طن تبريد. استلزم ذالك بناءَ جهاز اختبار تجريبيِ يتكون من أربعة أجزاء وهي نظام التثليج وحجرات الاختبار البيئية ومعدات القياس و أجهزة السيطرة على درجات الحرارة . تم تثبيت درجة حرارة الهواء الداخلية عند 25 °م بصلةً جافة و19 °م بصلةً رطبة. بينما تغيرت درجات حرارة الهواء الخارجية مِنْ 35 °م إلى 55 °م بزياداتِ مقدارها 5 °م كل مرة. أثبتت الدراسةَ أنّ مائع التثليج 290R هو البديل الأفضل إلى مائع التثليج 22R عندما يَعْملُ نظامَ التكييف تحت درجات حرارة بيئية عالية. كان مائع التثليج R407C اقربُ اداءاً إلى المائع R22 و يأتي بعده R410A.

Listing 1 - 10 of 10
Sort by
Narrow your search

Resource type

article (10)


Language

English (9)

Arabic and English (1)


Year
From To Submit

2017 (3)

2015 (2)

2014 (1)

2012 (1)

2011 (2)

More...