research centers


Search results: Found 3

Listing 1 - 3 of 3
Sort by

Article
The Kinetic Model for Decolorization of Commercial Reactive Red 120 Azo Dye Aqueous Solution by the Fenton Process and Study the Effect of Inorganic Salts

Authors: Ahmed Khudhair Hassan --- Hasan Fadhil AL-Rubai --- Hadi Hassan AL-Shamary
Journal: Al-Nahrain Journal of Science مجلة النهرين للعلوم ISSN: (print)26635453,(online)26635461 Year: 2018 Volume: 21 Issue: 3 Pages: 82-93
Publisher: Al-Nahrain University جامعة النهرين

Loading...
Loading...
Abstract

The degradation of a commercial azo dye Reactive Red 120 (RR120) in synthetic aqueous solution using Fenton's oxidation has been studied. The influence of different reaction parameters such as pH, hydrogen peroxide, ferrous sulfate, and the RR 120 concentration on the oxidative degradation of RR 120 have been appraised. The optimal reaction conditions were determined and it was found to be pH = 3.50, [H2O2] = 1.1×10-3 M, [Fe2+] = 1.0×10-4 M for [RR 120] = 7.5×10-5 M. Under optimal conditions, 96.0% decolorization efficiency of dye in aqueous solution was achieved after 15 min of reaction. The effect of azo bond loading (Lazo bond), from 0.25 to 1.0, and pH values from 2.5 to 5.0 were estimated on RR 120 color removal kinetic rates. A correlation between the kinetic of the color removal rates (ln k2) versus Lazo bond was carried out at the different pH levels. The color removal rate increased linearly with decreasing Lazo bond, in the order of pH: 3.5 > 5.0 > 2.5. All the experimental data were analyzed using the first and second-order kinetic models. The second-order provides the best correlation of the data. 67% Chemical Oxygen Demand (COD) removal efficiency of the RR 120 were achieved after 15 min of reaction by fixing the initial H2O2/Fe2+ molar ratio, COD loading factor (LCOD), and pH at 11, 0.25 and 3.5, respectively. Also, the effects of various inorganic anions (such as Cl−, SO42-, CO32-, etc.) on the oxidation efficiency of Fenton were studied. This study can benefit planners who deal with contaminated textile wastewater using chemical treatment by advanced oxidation technologies.


Article
DESTRUCTION OF EXPIRED DRUGS TO ADDRESS ENVIRONMENT-FRIENDLY
اتلاف الادوية المنتهية الصلاحية (المستحلبات) بشكل صديق للبيئة

Loading...
Loading...
Abstract

The method of incineration was chosen to treat the most commonly used antimicrobial agents in Iraq (Triclabendazol, Oxfendazol, Mebendazole), which are antibiotics for children. The moisture content and chemical oxygen demand (COD) were examined and the results were (93.34, 94.88, 92.97)%, (52000, 33200, and 64000) mg/ L. The temperature was determined as a variable in the burning process (600, 500, 400)° C for the purpose of calculating the loss of ignition LOI and determining the ideal temperature. The results of the models (Triclabendazol, Oxfendazol, Mebendazole) (94.92, 93.12, 58.81% and 88.87), (62.61, 44.08%, 98.75, 84.98 and 55.086)% respectively. When mixing the three models in equal proportions, the percentage of loss was 92.87%. The analysis of the active aggregates using FTIR device was determined. A diagram of each dryer model was determined before burning and re-examination at each degree after burning. It was observed that the peaks of the model fingerprint and the active aggregates were dissolved and the materials were fully decomposed to carbon at a temperature of 600°C.

اختيرت طريقة الحرق لمعالجة مخلفات دوائية (مستحلبات) شائعة الاستخدام في العراق وهي (Triclabendazol, Oxfendazol, Mebendazole) وهي مضادات حيوية للالتهابات خاصة بالاطفال، اجري فحص محتوى الرطوبة والمتطلب الكيمياوي للاوكسجينChemical Oxygen Demand COD وكانت النتائج (92.97، 94.88، 93.34)% و (64000، 33200، 52000)% ملغم/لتر، وحددت درجة الحرارة كعامل متغيير في عملية الحرق (400، 500، 600)م لغرض حساب نسبة الفقدان Loss of Ignition LOI وتحديد درجة الحرارة المثالية وكانت النتائج للنماذج (Triclabendazol, Oxfendazol, Mebendazole) (58.81، 93.12، 94.92)% و (44.08، 62.61، 88.87)% و (55.086، 84.98، 98.75)% على التوالي وعند خلط النماذج الثلاثة بنسب متساوية كانت نسبة الفقدان (92,87)%ن واعتمد فحص المجاميع الفعالة باستخدام جهاز FTIR حيث حدد مخطط لكل نموذج مجفف قبل الحرق وأعادة الفحص عند كل درجة بعد الحرق ولوحظ أختفاء القمم التي تدل على بصمة النموذج والمجاميع الفعالة و تتحلل المواد بشكل كامل الى كاربون عند درجة حرارة 600م.


Article
Performance Evaluation of Al-RustamiyaWastewater Treatment Plant
تقييم اداء محطة الرستمية لمعالجة مياه الصرف الصحي

Author: AbdulKarim Muneer AbdulRazzak عبدالكريم منيرعبدالرزاق
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2013 Volume: 19 Issue: 4 Pages: 429-438
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Al-Rustamiya sewage treatment plant (WWTP) serves the east side of Baghdad city (Rusafa) and is considered one of the largest projects.It consists of three parts (old project F0, first extension F1, and second extension F2) that treat wastewater and the effluent is discharged into Diyala river and thus into the Tigris River. These plants are designed and constructed with an aim to manage wastewater to reachIraqi effluent standard for BOD5, COD, TSS and chloride concentrations of 40, 100, 60 and 600 mg/L respectively. The data recordedfrom March till December 2011 provided from Al-RustamiyaWWTP, were considered in this study to evaluate the performance of the plant. The results indicated that the strength of the wastewater entering the plant varied from medium to high. The average concentrations of the effluent of BOD5, COD, TSS and chloride were within Iraqi effluent standards. The overall efficiency removalswere:For BOD5: 92.1, 90.31, and 92.96% for F0, F1, and F2 respectively COD: 88.23, 87.9, and 87.95% for F0, F1, and F2 respectively TSS: 86.98, 80.72, and 89% for F0, F1, and F2 respectively Chloride: 14.79, 15.37, and 15.31% for F0, F1, and F2 The mean value of BOD5/COD ratio of the raw wastewater was 0.67 as for typical untreated domestic wastes. The mean BOD/COD ratios of the treated sewage from F0 was 0.48, from F1 0.50 and from F2 0.38. These ratios did not confirm with the typical ratios indicating that the wastewaterneeds more treatment.

تخدم محطة معالجة مياه الصرف بالرستمية الجانب الشرقي لمدينة بغداد الرصافة ويعتبر واحد من اكبر المشاريع ويتالف من ثلاثة اجزاء (المشروع القديم F0والتوسعة الاولىF1 والتوسعة الثانية F2) ويقوم المشروع بمعالجة مياه الصرف الصحي ورمي المياه بعد المعالجة الى نهر ديالى وهكذا الى نهر دجلة بعد المرور بمجموعة من العمليات. وهذه المحطة مصممة لمعالجة مياه الصرف الصحي يموجب المواصفة العراقية 40لتراكير BOD5,CODوالمواد العلقة والكلوريد المساوية الى 40 و100و60و 600 ملغم/لتر على التوالي.القراءات اليومية للفترةمن بداية شهر اذار ولغاية نهاية كانون الاول عام 2011 لقياسات خصائص مياه الصرف الصحي في مداخل ومخارج المحطة زودت من ادارة محطة معالجة الرستميةلتقييم اداء المحطة.النتائج اظهرت ان قوة مياه الصرف الصحي تتفاوت من الوسط الى المستوى العالي وان المياه المعالجة ذات تراكيز لل BOD5 و COD والمواد العالقة والكلوريدكانت ضمن المواصفة العراقية لرمي المياه المعالجة الى المصادر المائية. والاداء العام لمحطة الرستمية بمراحله المشار لها يكون جيد .وكانت كفاءة الازالة العامة هي:1-قيم ال BOD592.1 و 90.31 و 92.96% على التوالي للرستمية FoوF1 و F22-قيم ال COD87.23 و 87.9و 87.95 %على التوالي للرستمية FoوF1 و F23-قيم ال86.98 SS و 80.72و 89%على التوالي للرستمية FoوF1 و F24-قيم الكلورايد 14.79 و 15.37و 15.31% على التوالي للرستمية FoوF1 و F2.ان متوسط قيمة نسبة (BOD5/COD) لمياه الصرف الخام كانت 0.67 وكما هي لمياه الصرف المنزلية غير المعالجة. واماللمياه الصرف المعالجة فان معدل نسبة BOD5/COD في الرستمية القديم F0هي 0.48 وبالنسبة للتوسع الاولFفكانت0.50 والبالنسبة للتوسع الثاني Fكانت النسبة 0.38 . وهذه النسب من (BOD5/COD) لم تكن مطابقة للنسب المثالية للمياه المعالجة.و هذه المياه تحتاج الى معالجة اكثر.

Listing 1 - 3 of 3
Sort by
Narrow your search

Resource type

article (3)


Language

English (2)

Arabic (1)


Year
From To Submit

2018 (2)

2013 (1)