research centers


Search results: Found 9

Listing 1 - 9 of 9
Sort by

Article
Cooling Load Calculations For Typical Iraqi Roof And Wall Constructions Using Ashrae's RTS Method
حسابات حمل التبريد لتركيبات سقوف وجدران نموذجية عراقية باستخدام نظرية RTS لاشري

Authors: Khalid Ahmed Joudi خالد أحمد جودي --- Ali Naser Hussien علي ناصر حسين
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2015 Volume: 21 Issue: 5 Pages: 98-114
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The present work is an attempt to develop design data for an Iraqi roof and wall constructions using the latest ASHRAE Radiant Time Series (RTS) cooling load calculation method. The work involves calculation of cooling load theoretically by introducing the design data for Iraq, and verifies the results experimentally by field measurements. Technical specifications of Iraqi construction materials are used to derive the conduction time factors that needed in RTS method calculations. Special software published by Oklahoma state university is used to extract the conduction factors according to the technical specifications of Iraqi construction materials. Good agreement between the average theoretical and measured cooling load is obtained and the difference between them does not exceed 9.3%. الدراسة الحالية هي محاولة لتقديم بيانات تصميمية لسقوف وجدران عراقية باستخدام أحدث الطرق المستخدمة من قبل جمعية اشري لحساب حمل التبريد وهي طريقة السلسلة الزمنية للإشعاع (RTS). يتضمن العمل حساب الحمل الحراري نظريا باستخدام ظروف العراق التصميمية, والتحقق منها بالقياسات العملية. تم استخدام المواصفات الفنية لمواد بناء عراقية لاشتقاق المعاملات الزمنية للتوصيل المطلوبة للعمليات الحسابية بطريقة (RTS). وقد استخدم برنامج خاص مصمم من قبل جامعة أوكلاهوما الأميركية لاستخراج المعاملات الزمنية للتوصيل وفقا للمواصفات الفنية لمواد البناء العراقية. وقد تم الحصول على توافق جيد بين معدل حمل التبريد المحسوب نظريا والمقاس عمليا ولم يتجاوز الفرق بينهما 9,3%.


Article
Feasibility Study of Power Saving Based on Using EMMEDUE M2 Building System

Author: Akram. W. Izzat
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2008 Volume: 14 Issue: 4 Pages: 3257-3267
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The present work concentrates on the feasibility of the heat load reduction by utilizing some structural material with very poor heat conductivity as isolators for heat transmission. Average annular heating and cooling load is estimated for a typical building of certain area and design using ordinary structural material and EMMEDUE M2 building system. The basic element of the new structural material is made of a foam polystyrene core that is self extinguishing and chemically inert with varying density and thickness depending on panel type. The calculations are based on the average maximum and minimum monthly temperature in Baghdad. Building heating load could mainly depend on the average temperature difference per each daily hour per year, while building cooling load components are; direct solar radiation, transmission load, ventilation/infiltration load and internal load. Except the transmission load which depends on the same average temperature difference the other factors could be calculated separately.A reduction of 55% in the annual load is estimated per each house using the new building technology. For a district sums up 1000 houses of the new structural design the total saving of power will be 10.45 MW. The saving in heating and cooling cost is estimated based on capital cost of the diesel generation system and the fuel consumption cost. It has been concluded that the passive structural heat isolation is a very effective manner in countries like Iraq which has severe temperature differences between the summer and winter seasons. يتركز البحث على مدى عملية تفليل الحمل الحراري بأستخدام مواد بناء ذات توصيل حراري ضعيف كمواد عازلة للأنتقال الحراري. تم تخمين معدل الحمل الحراري والتريد السنوي لبناية نموذجية ذات مساحة وتصميم معين بأستخدم مواد بناء عادية مقارنة بمادة بناء EMMEDUE M2. العنصر الأساسي في مادة البناء الجديدة مكونة من مادة البوليسترين الرغوية ذات قابلية الأطفاء التلقائي وغير الفعالة كيمياويا وبكثافات مختلفة وسمك يعتمد على نوع القطعة.تم بناء الحسابات على معدل القيم العليا والسفلى لدرجات الحرارة الشهرية في مدينة بغداد. يعتمد الحمل الحراري على معدلات فرق درجات الحرارة اليومية على مدار السنة بينما يعتمد حمل التبريد على: أشعة الشمس المباشرة¸ الحمل الأنتقالي, حمل التهوية, والحمل الداخلي. بأستثناء الحمل الأنتقالي الذي على نفس معدلات فروقات درجات الحرارة فأن بقية العوامل تحسب بشكل منفصل.تم تخمين مفدار النقصان في قيمة الحمل السنوي بقيمة مقدارها 55% لكل بناية يتم فيها أستخدام مواد البناء العازلة والمشار اليها في البحث. لحي سكني مكون من 1000 بناية مبنية من مادة البناء العازلة يكون مقدار الأدخار في طاثة التدفئة والتبريد 10.45 ميكاواط. تم حساب معدل الأدخار في كلفة التدقئة والتبريد بناءا على القيمة الفعالة لمنظومة التوليد وكلفة الوقود المتسخدم لمدة سنة. حيث تم الأستنتاج من البحث أن أستخدام مواد البناء العازلة في دول ذات مناخ قاري يكون ذا جدوى اقتصادية عالية جدا.


Article
COMPARISON OF COOLING LOAD CALCULATION METHODS BY

Author: Khalid A. Joudi
Journal: Al-Fatih journal مجلة الفتح ISSN: 87521996 Year: 2005 Volume: 1 Issue: 24 Pages: 57-61
Publisher: Diyala University جامعة ديالى

Loading...
Loading...
Abstract

The present work includes cooling load measurement in Iraq. One room located in Baqubah was the object of the study. The measurement was taken for the room in summer months of 2004 (i.e. in May, June, July, August & September). The area of test room was 15 m2 and 3 m ceiling height with medium weight construction specifications. The test room includes exterior east and west wall facing, un-conditioning adjacent space with an exterior roof, east window and an exterior west door. The air conditioner unit used in this work was a window type with a nominal capacity of 2 T.R. (7 kW). The theoretical cooling load was predicted by three methods of cooling load calculation, which are TFM, CLTD/SCL/CLF & TETD/TA methods. Measurement of cooling load showed that there is a large difference between the measured and predicted cooling load with all theoretical methods. The difference ranged from 33% to 40%. This large difference is appear because of the several season such as the air conditioner type, suffer environmental and the construction specification of the test room where it’s represent the Iraqi building and not exactly same as building specification tabulated in ASHRAE tables ,يعنى هذا البحث بإجراء قياسات عملية لحساب حمل التبريد في العراق. غرفة الاختبار الواقعة في مدينة بعقوبة كانت مشروع الدراسة حيث أخذت القياسات خلال اشهر الصيف (أيار, حزيران, تموز, آب و أيلول). و كانت مساحة غرفة الاختبار 15م2 مع ارتفاع 3م للسقف مع مواصفات إنشاء ذات تركيب متوسط. تشمل غرفة الاختبار جداران خارجيان أحدهما مواجه للشرق و الآخر مواجه للغرب مع حيز مجاور غير مكيف مع سقف خارجي و كذلك شباك مواجه للشرق و باب خارجية مواجه للغرب. و قد كانت منظومة التكييف التي لتبريد هذه الغرفة تم استخدام وحدة تبريد جدارية سعة 2طن تثليج (7كيلو واط). أجريت الحسابات النظرية لحمل التبريد بثلاث طرق لحساب حمل التبريد و هي طريقة دالات التحويلTFM وطريقة حمل التبريد من فرق درجات الحرارة (CLTD) بالإضافة إلى طريقة فرق درجات الحرارة الكلي المكافئ (TETD). أظهرت النتائج العملية لحسابات حمل التبريد للغرفة أن هناك فرق في الحمل كبير نسبيا بين النتائج العملية و النتائج النظرية و الفرق يتراوح بين 33% إلى 40%.


Article
Reduction Cooling Load Using Intelligent Envelope System
تقليل حمل التبريد بتطبيق منظومة غلاف المبنى الذكي

Authors: wael awad alaqily وائل عواد العُقيـلي --- Dr.Ibrahim J.K. Al-Yousif م.د.إبراهيم جـــواد آل يوسف
Journal: The iraqi journal of architecture and planning المجلة العراقية للهندسة المعمارية ISSN: 19991738 Year: 2008 Volume: 4 Issue: 14-15 Pages: 76-96
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

The nature of Iraqi climate which represents longevity the hot summer seasons, made almost the buildings depend on mechanical services to remove the cooling loads and ensure a suitable conditions of human activity within it. Therefore and for the importance of topic many architecture researches in Iraq focused on searching practical solutions that could reduce the consumption in buildings through controlling the climate effect on these buildings, by following different strategies for cooling. The research has focused on active cooling strategies which contribute on a larger part to the reduction of the cooling load in the buildings through its providing with the disposition of adaptation and response. This research has come as an attempt at the consolidation of that strategy through the activation of the response of the building envelope to the changing circumstances of the external environment by application of intelligent envelope system that includes a group of technologies works for the improvement of the thermal performance to the building.For the purpose of the knowledge of the effect of the application of the system in the reduction of the cooling load in the building holding several applied tests using computer simulation program (Ecotect). And the test has taken place on a building that represents a model to residential house that designed with taking the view of consideration the most environmental criteria that advised on previous studies.The research reached that the using of intelligent envelope system works for the reduction of the annual cooling loads by the rate of (24.97 %) which means the reduction of energy loss to quarter approximately. Hence this research comes as an attempt to give a clear conception to the designer about the benefit of the intelligent envelope system application and the encouragement on its use. أصبحت مسألة استهلاك الطاقة في مختلف قطاعات الحياة وخاصةً قطاع المباني الذي يمثل الجزء الأكبر من هذا الاستهلاك مسألة جوهرية تشغل دول العالم كافة وبضمنها العراق. إن طبيعة مناخ العراق المتمثلة بفترتين رئيستين وهما فصلي الشتاء والصيف، وقصر فترات الاعتدال جعل الاستعانة بالمنظومات الخدمية الميكانيكية والكهربائية وبشكل مكثف في المباني أمراً ضرورياً ومهماً لضمان بيئة داخلية ملائمة للشاغلين وخاصةً في فترة الصيف الحار. أدى ذلك إلى زيادة في معدلات استهلاك الطاقة في المباني وبشكل خاص في العقدين الأخيرين، ومثلت هذه المشكلة الحدود العامة للدراسة، ولأهمية الموضوع سعت دراسات وبحوث عديدة إلى محاولة إيجاد حلول عملية تقلل من صرفيات الطاقة في المباني من خلال السيطرة على تأثيرات المناخ على المبنى بإتباع استراتيجيات مختلفة، تبدأ بالإستراتيجية الذاتية غير المستهلكة للطاقة والتي يقتصر دورها في تقليل عمليات السريان الحراري إلى الداخل ودعم عمليات الفقدان الحراري ضمن غلاف المبنى ولان تلك الاستراتيجة غير كافية للتبريد الكفوء فقد تطرق البحث إلى استراتيجيات التبريد الفعالة والتي تسهم بشكل اكبر في تقليل حمل التبريد في المباني من خلال تزويده بقابلية الاستجابة والتكيف مع متغيرات البيئة الخارجية، وقد جاء هذا البحث كمحاولة لتعزيز تلك الإستراتيجية من خلال تفعيل استجابة غلاف المبنى لظروف البيئة الخارجية المتغيرة بتطبيق منظومة غلاف المبنى الذكي والتي تشتمل على مجموعة من التقنيات تعمل على تحسين الأداء الحراري للمبنى بإتباع الذكاء كوسيلة تعطي صفة التكامل لتلك التقنيات مع النظم الميكانيكية للمبنى والمنسجمة مع التكنولوجيا البنائية المحلية،ولغرض معرفة تأثير تطبيق منظومة غلاف المبنى الذكي في تقليل حمل التبريد في المبنى تم إجراء عدة اختبارات تطبيقية بالاستعانة ببرنامج محاكاة الطاقة الحاسوبية (Ecotect)، أدرجت النتائج باعتماد الرسوم التوضيحية وبناءاً عليها توصل البحث إلى إن استعمال المنظومة يعمل على تقليل أحمال التبريد السنوية للمبنى بمعدل( 24.97%) مما يعني تقليل الهدر بالطاقة المصروفة إلى الربع تقريبا. وبذلك يأتي البحث كمحاولة لتقديم صورة واضحة أمام المصمم عن جدوى تطبيق المنظومة والتشجيع على استخدامها.


Article
Study to improve heat transfer reduction for exist building’s roof by using local available materials
دراسة لتحسين الحد من انتقال الحرارة لسطح مبنى مشيد باستخدام المواد المحلية المتاحة

Author: Assist. Prof.Dr. Ibtisam Ahmed Hasan Salih أستاذ مساعد دكتور ابتسام احمد حسن
Journal: Journal of Engineering and Sustainable Development مجلة الهندسة والتنمية المستدامة ISSN: 25200917 Year: 2015 Volume: 19 Issue: 3 Pages: 1-18
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

The research is developed to study the impact of structural change makeup for the cover of an exist building’s roof in the city of Baghdad on thermal loads .it included the study of several variables to change the quality of thermal insulation materials for ceilings and the quality of thermal insulation material added, the quality of seven kinds for local material for external packaging ,they are reed, reed without air gap, nylon mat, felt, Jnvas, Jnvas stuffed with sawdust, and hyber HTS and the quality of material used for secondary roof which are plate of gypsum and a hollow plastic plates of (8.5 mm) thickness and (4.7 mm). يهدف البحث إلى دراسة تأثير تغير التركيب الإنشائي لغلاف سقوف المباني المشيدة في مدينة بغداد على الأحمال الحرارية المنتقلة. حيث شملت الدراسة عدة متغيرات مثلا نوعية مواد البناء للسقوف السائدة ونوعية مواد العزل الحراري المضافة وأنواع مختلفة من المواد المحلية الصنع (قصب بفجوة هوائية,قصب بدون فجوة هوائية,حصير نايلون,لباد, جنفاص, جنفاص محشو بنشارة الخشب ولباد. وكذالك مادة مستوردة تستخدم كطلاء خارجي للمبنى (من ضمنها السقوف) تعرف ب (hyber HTS )) التي يمكن استخدامها كتغليف خارجي (الجانب المعرض لتأثير الطقس) ,وثلاثة أنواع من المواد المستخدمة في تغليف السقوف من الداخل هي ألواح جبسيه جاهزة وألواح بلاستيكية مجوفة سمك 8.5 mm)) وألواح بلاستيكية مجوفة سمك (4.7 mm) .بينت النتائج إن أفضل أداء حراري قد تمثل بالسقف المشيد من الطابوق المثقب والبلاط الخارجي من الطابوق ألفرشي (النموذج الثاني) بزيادة مقدارها ( 9.23%) عن القيمة القياسية لمعامل انتقال الحراري الكلي للسقوف. استخدام المواد العازلة الخارجية المشار لها أضافت زيادة ملحوظة في مقدار مقاومة السقوف لانتقال الحرارة مما سبب تقليل في قيمة الحمل الحراري قد يصل إلى 30% عند استخدام القصب المجوف. إما استخدام السقوف الثانوية فقد كان له اثر كبير في تقليل الحمل الحراري تراوحت قيمته من 76% إلى 80% وكانت الألواح البلاستيكية المجوفة سمك 8.5 mm)) الأفضل أداءً.


Article
Internal Convective Heat Transfer Effect on Iraqi Building Construction Cooling Load
تأثير انتقال الحرارة الداخلي بالحمل على حمل التبريد لأبنية عراقية التركيب الإنشائي

Authors: Khalid Ahmed Joudi خالد أحمد جودي --- Ali Naser Hussien علي ناصر حسين
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2015 Volume: 21 Issue: 9 Pages: 119-134
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

This work involves the calculation of the cooling load in Iraqi building constructions taking in account the effect of the convective heat transfer inside the buildings. ASHRAE assumptions are compared with the Fisher and Pedersen model of estimation of internal convective heat transfer coefficient when the high rate of ventilation from ceiling inlet configuration is used. Theoretical calculation of cooling load using the Radiant Time Series Method (RTSM) is implemented on the actual tested spaces. Also the theoretical calculated cooling loads are experimentally compared by measuring the cooling load in these tested spaces. The comparison appears that using the modified Fisher and Pedersen model when large ventilation rate is used; modify the results accuracy to about 10%. العمل الحالي يتضمن حساب حمل التبريد في تراكيب البناء العراقي مع الأخذ في الاعتبار تأثير انتقال الحرارة بالحمل داخل البناية. فرضية اشري قورنت مع طريقة فيشر وبدرسن في تخمين معامل انتقال الحرارة الداخلي عند استخدام معدلات عالية للتهوية لحالة تجهيز الهواء من السقف. تم احتساب حمل التبريد نظريا باستخدام طريقة السلسلة الزمنية للإشعاع RTSM)) لفضاءات اختبار حقيقية. كذلك فان حمل التبريد المحسوب نظريا تم مقارنته عمليا بقياس حمل التبريد في هذه الفضاءات. المقارنة أظهرت ان استخدام طريقة فيشر وبدرسن المعدلة لمعدلات كبيرة من التهوية, يحسن دقة النتائج لحدود تصل ل 10%.


Article
مقارنة السلوك الحراري لمواد التغليف الطبيعية والصناعية للجدران على حمل التبريد في بغداد

Authors: أياد كاظم خليف --- علي عبد الوهاب اسماعيل --- نصر فاضل حسين
Journal: Journal of University of Babylon مجلة جامعة بابل ISSN: 19920652 23128135 Year: 2013 Volume: 21 Issue: 4 Pages: 1450-1463
Publisher: Babylon University جامعة بابل

Loading...
Loading...
Abstract

Research aims to make a comparison of the thermal performance between modern packaging materials and traditional for walls of buildings in Iraq. Where increased in recent times the entry of new materials used in the packaging and external facades of buildings or inside the building as decorative materials. The study conducted a survey of those materials and thermal testing and analyzing the value of convection (cooling load) when the use of such materials or other traditional materials. The results showed that the percentage reduction in load when using internal packaging material ranges between 12% -10%, which is higher than the value of the reduction of external packaging materials did not exceed 2%. The study also pointed out the need to use a thermal insulation when covering the wall to make the thermal specifications of the walls of the Iraqi within the international standard specifications. هدف البحث إلى إجراء مقارنة للأداء الحراري بين مواد التغليف الحديثة والتقليدية للجدران المباني العراقية. حيث ازداد في الآونة الأخيرة دخول مواد جديدة تُستخدم في تغليف واجهات المباني الخارجية أو داخل المبنى كمواد ديكور. قامت الدراسة بأجراء مسح لتلك المواد وأجراء الفحوص الحرارية لها وتحليل قيمة الحمل الحراري (حمل التبريد) عند استخدام تلك المواد أو المواد التقليدية الأخرى. بينت النتائج بأن نسبة التخفيض في الحمل عند استخدام مواد التغليف الداخلية يتراوح بين 12%-10% وهو أعلى مقارنة بقيمة التخفيض للمواد التغليف الخارجية حيث لم تتجاوز 2%. كما أوضحت الدراسة ضرورة استخدام العازل الحراري عند تغليف الجدران لجعل المواصفات الحرارية للجدران العراقية ضمن المواصفات القياسية الدولية.


Article
مقارنة السلوك الحراري لمواد التغليف الطبيعية والصناعية للجدران على حمل التبريد في بغداد

Authors: أياد كاظم خليف --- علي عبد الوهاب اسماعيل --- نصر فاضل حسين
Journal: Journal of University of Babylon مجلة جامعة بابل ISSN: 19920652 23128135 Year: 2013 Volume: 21 Issue: 4 Pages: 1450-1463
Publisher: Babylon University جامعة بابل

Loading...
Loading...
Abstract

Research aims to make a comparison of the thermal performance between modern packaging materials and traditional for walls of buildings in Iraq. Where increased in recent times the entry of new materials used in the packaging and external facades of buildings or inside the building as decorative materials. The study conducted a survey of those materials and thermal testing and analyzing the value of convection (cooling load) when the use of such materials or other traditional materials. The results showed that the percentage reduction in load when using internal packaging material ranges between 12% -10%, which is higher than the value of the reduction of external packaging materials did not exceed 2%. The study also pointed out the need to use a thermal insulation when covering the wall to make the thermal specifications of the walls of the Iraqi within the international standard specifications. هدف البحث إلى إجراء مقارنة للأداء الحراري بين مواد التغليف الحديثة والتقليدية للجدران المباني العراقية. حيث ازداد في الآونة الأخيرة دخول مواد جديدة تُستخدم في تغليف واجهات المباني الخارجية أو داخل المبنى كمواد ديكور. قامت الدراسة بأجراء مسح لتلك المواد وأجراء الفحوص الحرارية لها وتحليل قيمة الحمل الحراري (حمل التبريد) عند استخدام تلك المواد أو المواد التقليدية الأخرى. بينت النتائج بأن نسبة التخفيض في الحمل عند استخدام مواد التغليف الداخلية يتراوح بين 12%-10% وهو أعلى مقارنة بقيمة التخفيض للمواد التغليف الخارجية حيث لم تتجاوز 2%. كما أوضحت الدراسة ضرورة استخدام العازل الحراري عند تغليف الجدران لجعل المواصفات الحرارية للجدران العراقية ضمن المواصفات القياسية الدولية.


Article
The effect of building facade Recovering by unclassical configuration reflecting Aluminum plates on energy consumption Numerical and Experimental Study
تغليف واجهات الابنية بالواح الالمنيوم العاكس الغير تقليدية الشكل وتاثيره على الطاقة الكهربائية المستهلكة للاغراض التكييف ( دراسة نظرية وعملية )

Authors: Atif Ali Hasan عاطف علي حسن --- Kadhum Audaa كاظم عودة جحف
Journal: DIYALA JOURNAL OF ENGINEERING SCIENCES مجلة ديالى للعلوم الهندسية ISSN: 19998716 Year: 2017 Volume: 10 Issue: 2 Pages: 12-34
Publisher: Diyala University جامعة ديالى

Loading...
Loading...
Abstract

The present numerical and experimental study aims to specify the amount of conserved electrical energy by reducing the environment effects on the building in summer season by covering the outer surfaces wall with plates were made from reflected aluminum of [ANS H35.1(2001)] with unconventional configurations. The room model was with dimensions of (1×1×2) m located in 3rd floor of a building in Baghdad city at latitude of (33.2 No). Using 200 mm thickness thermal insulation type of styropor (polystyrene) to cover the roof, ground and three walls inside room to reducing the heat transfer through these walls. Moreover, the wall of (1×2) m under study was at orientation to the east. This room was equipped with an air-conditioning unit with capacity of (1 Ton) to provide a cold space inside the room to obtain the standard thermal condition. The temperatures were recorded on the outer and inner surfaces of the wall. The air temperatures were recorded in the shadow for one day only (from 5 am to 6 pm) through summer months of 2015. The results show that the using proposed plates reducing the electrical energy consumption for cooling purpose and obtained an improved in saving was about (43.4- 50.8)% for closed air gap case in behind it. However, when using the thermal insulation the saving was about (62.5-63.4) %. While the saving was increased when that plates painted by thermal paints the saving raised to (57-63.3) % at presence the closed air gap and the saving becomes (68-70.9) % when adding the thermal insulation. الدراسة النظرية والعملية الحالية تهدف الى تحديد كمية الطاقة الكهربائية المرشدة من خلال تقليل التاثيرات البيئية الخارجية على بناية في فصل الصيف من خلال تغليف اسطح الجدران الخارجية بصفائح مصنوعة من الالمنيوم العاكس نوع [ANS H35.1(2001)] مع اشكال غير تقليدية . حيث كانت الغرفة النموذج بابعاد (2×1×1) متر تقع في الطابق الثالث ضمن بناية في مدينة بغداد عند خط عرض 33.2 درجة شمالا .وايضا تم استخدام عازل حراري بسمك 200 ملم نوع ستاييربور (البولي ستايرين) من اجل تغليف السقف والارضية والجدران الثلاثة الاخرى من داخل الغرفة من اجل تقليل انتقال الحرارة من تلك الجدران. اما الجدار قيد الدرسة الذي بابعاد (2×1) متر و مواجه لجهة الشرق . هذه الغرفة مجهزة بوحدة تكييف هواء سعتها واحد طن لتوفير حيز بارد داخل الغرفة ومن اجل الحصول على الظروف الحرارية القياسية. تم تسجيل درجات الحرارة على الاسطح الخارجية والداخلية للجدار وكذلك درجة حرارة الهواء الخارجي تم قياسها في الظل وليوم واحد من الساعة الخامسة صباحا الى الساعة السادسة عصرا خلال اشهر الصيف فقط من عام 2015. واظهرت النتائج ان استخدام الصفائح المقترحة سوف يقلل من استهلاك الطاقة الكهربائية لاغراض التكييف وان التوفير في الطاقة سيكون بمقدار ( 43.4 – 50.8 )% بوجود الفجوة الهوائية المغلقة خلف الصفيحة. وكذلك باستخدام العزل الحراري يكون التوفير بمقدار (62.5 – 63.4 )% بينما نلاحظ ازدياد التوفير عند طلاء بالاصباغ الحرارية ان التوفير يرتفع الى( 57 – 63.3 )% عند وجود الفجوة الهوائية المغلقة ويصبح التوفير بمقدار ( 68 – 70.9 ) %عند استخدام العازل الحراري خلفها.

Listing 1 - 9 of 9
Sort by
Narrow your search

Resource type

article (9)


Language

Arabic (5)

English (4)


Year
From To Submit

2017 (1)

2015 (3)

2013 (2)

2008 (2)

2005 (1)