Thermo- economic analysis of inlet air cooling in gas turbine plants in Basrah(Al-Rumaila gas turbine power plant case study)
تحليل حراراي - اقتصادي لتبريد الهواء الداخل لمحطات القدرة الغازية في البصرة ( محطة القدرة الغازية في الرميلة كحالة دراسية)

Author: Hussien S. Sultan
Journal: University of Thi-Qar Journal for Engineering Sciences مجلة جامعة ذي قار للعلوم الهندسية ISSN: 26645564/26645572 Year: 2016 Volume: 7 Issue: 1 Pages: 58-66
Publisher: Thi-Qar University جامعة ذي قار

Loading...
Loading...
Abstract

In the hot regions the demand on electricity increased in the hot months. Gas turbine power plant is a good solution for this problem, since it has low cost, low time of installation and stable with electricity grid variation. But the power output of gas turbine is affected by the ambient temperature, the power decrease by 18% when the ambient temperature increase to 40oc. Inlet air cooling methods are used to boost the power losses in the hot days. In the present study a thermally and economically analysis was performed for Al-Rumaila gas turbine power plant located in Basrah (south of Iraq). The plant consist from five units and each unit designed to generates 296MW.The results shows that, the maximum decrease in the power developed due the increase in ambient air temperature reaches 22.97% during the month of July. The percentage of power saving due inlet air cooling increased with increasing the ambient air temperature.

في المناطق ذات المناخ الحار يزداد الطلب على الطاقة الكهربائية في الاشهر الحارة. تعتبر محطات القدرة الغازية حل جيد لهذه المشكلة, لان كلفة انشائها منخفضة , الوقت اللازم لتشييدها قصير ومستقرة مع التغيرات الحاصلة في الشبكة الكهربائية. لكن القدرةالمنتجة من المحطات الغازية تتأثر كثيرا بدرجة حرارة المحيط الخارجي, حيث تنخفض القدرة بمقدار 18% عندما ترتفع درجة حرارة المحيط الخارجي الى 40 درجة مئوية. تستخدم طرق متعددة لتبريد الهواء الداخل للمحطات الغازية من اجل تعزيز القدرة الخارجة منها. في هذه الدراسة تم تطبيق تحليل حراري اقتصادي لمحطة قدرة غازية في محافظة البصرة جنوب العراق. المحطة تحتوي خمس وحدات والقدرة التصميمية لكل وحدة هي 296 ميكاواط. اثبتت النتائج ان اعظم هبوط للقدرة المنتجة بسسبب ارتفاع درجة حرارة المحيط الخارجي يصل 22.97% خلال شهر تموز. النسبة المئوية للتوفير في القدرة بسسبب تبريد الهواء الداخل تزداد مع ارتفاع درجة حرارة المحيط الخارجي.


Article
Monitoring of Evaporated Cooling Tower

Authors: Mahmood K. H. Al-Mashhadani --- Salam K .A1-Dawery
Journal: Iraqi Journal of Chemical and Petroleum Engineering المجلة العراقية للهندسة الكيمياوية وهندسة النفط ISSN: 19974884/E26180707 Year: 2009 Volume: 10 Issue: 4 Pages: 39-43
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The present study was conducted for monitoring of the evaporative cooling tower in methanol production plant using digital computer. Visual Basic computer program was usedfor the monitoring of the performance of the cooling tower. The structure program consists of sub programs andforms to show all the related variables such as temperature, flaw rate, pressure .... etc. that affect the cooling tower operation and give alarms and important functional information regarding these variables

Keywords

Monitoring --- cooling tower


Article
Development Of Absorption Cooling System Work By Using Solar Energy
تطوير عمل منظومة التبريد الامتصاصية باستخدام الطاقة الشمسية

Author: Hashim A.Hussain هاشم عبد حسين
Journal: Al-Rafidain University College For Sciences مجلة كلية الرافدين الجامعة للعلوم ISSN: 16816870 Year: 2013 Issue: 32 Pages: 131-160
Publisher: Rafidain University College كلية الرافدين الجامعة

Loading...
Loading...
Abstract

This paper is devoted to optimize the performance of absorption cooling system working with on solar energy .It aims at reducing the cost of the absorption cooling system and reducing the temperature of the generator to enable the cooler to work with solar collector more economical and to reduce the energy consumption compared with classical cooling system.The COP has been studied for four absorption systems which using water and lithium- Bromide. The temperature of the generator for each cycle was determined according to the (pressure – temperature –concentration) diagram. The COP has been determined by drawing it’s the change with the change of temperature of the generator after determination of condensation and evaporation temperature. The results of this work indicated that, the COP. for double effect cycle is high respectively, but it requires expensive solar receivers.

يهدف البحث إلى اختيار منظومة التبريد الامتصاصية الأكثر ملائمة للعمل في استخدام الطاقة الشمسية للحصول على الحرارة اللازمة لتشغيلها لتطوير نظام تبريد الهواء بتكاليف استثمارية اقل بايجاد معامل اداء مقبول ودرجة حرارة مولد منخفضة نسبياً تمكن المبرد من العمل باستخدام لواقط شمسية مسطحة أكثر اقتصادية والهدف الثاني هو تخفيض استهلاك الطاقة مقارنة مع أنظمة التبريد التقليدية . تم دراسة تغير معامل الأداء لمنظومات التبريد الامتصاصية المستخدمة لمحلول بروميد الليثيوم والماء لأربعة أنواع من هده المنظومات لتحديد معامل الأداء لكل منظومة والمقارنة بينهما لاختيار الأفضل . تم تحديد مجال درجة حرارة المولد لدوائر التبريد الأربعة اعتمادا على مخطط الضغط ودرجة الحرارة والتركيز. اعتمدت هده الدراسة على طريقة حل باستخدام الجداول والمخططات وطريقة الحل باستخدام برنامج EES. وتم دراسة أداء منظومات التبريد الامتصاصية الأربعة من خلال رسم مخطط تغير معامل الأداء تبعاً لتغير درجة الحرارة في المولد بعد أن تم تحديد درجة التكاثف والتبخر.


Article
Cooling Load Calculations For Typical Iraqi Roof And Wall Constructions Using Ashrae's RTS Method
حسابات حمل التبريد لتركيبات سقوف وجدران نموذجية عراقية باستخدام نظرية RTS لاشري

Authors: Khalid Ahmed Joudi خالد أحمد جودي --- Ali Naser Hussien علي ناصر حسين
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2015 Volume: 21 Issue: 5 Pages: 98-114
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The present work is an attempt to develop design data for an Iraqi roof and wall constructions using the latest ASHRAE Radiant Time Series (RTS) cooling load calculation method. The work involves calculation of cooling load theoretically by introducing the design data for Iraq, and verifies the results experimentally by field measurements. Technical specifications of Iraqi construction materials are used to derive the conduction time factors that needed in RTS method calculations. Special software published by Oklahoma state university is used to extract the conduction factors according to the technical specifications of Iraqi construction materials. Good agreement between the average theoretical and measured cooling load is obtained and the difference between them does not exceed 9.3%.

الدراسة الحالية هي محاولة لتقديم بيانات تصميمية لسقوف وجدران عراقية باستخدام أحدث الطرق المستخدمة من قبل جمعية اشري لحساب حمل التبريد وهي طريقة السلسلة الزمنية للإشعاع (RTS). يتضمن العمل حساب الحمل الحراري نظريا باستخدام ظروف العراق التصميمية, والتحقق منها بالقياسات العملية. تم استخدام المواصفات الفنية لمواد بناء عراقية لاشتقاق المعاملات الزمنية للتوصيل المطلوبة للعمليات الحسابية بطريقة (RTS). وقد استخدم برنامج خاص مصمم من قبل جامعة أوكلاهوما الأميركية لاستخراج المعاملات الزمنية للتوصيل وفقا للمواصفات الفنية لمواد البناء العراقية. وقد تم الحصول على توافق جيد بين معدل حمل التبريد المحسوب نظريا والمقاس عمليا ولم يتجاوز الفرق بينهما 9,3%.


Article
Construction and performance study of a solar - powered hybrid cooling system in Iraq
تقييم أداء منظومة تبريد هجينة تعمل بالطاقة الشمسية وفق الأجواء العراقية

Loading...
Loading...
Abstract

The systems cooling hybrid solar uses solar collector to convert solar energy into the source of heat for roasting Refrigerant outside of the compressor and this process helps in the transformation of Refrigerant from the gas to a liquid state in two-thirds the top of the condenser instead of two-thirds the bottom of the condenser as in Conventional cooling systems and this in turn reduces the energy necessary to lead the process of cooling. The system cooling hybrid use with a capacity of 1 ton and Refrigerant type R22 and the value of current drawn by the system limits (3.9-4.2A), the same value of electric current calculated by the system are Conventional within this atmosphere of Iraq, and after taking different readings of the temperatures and pressure to several points in the system's found that the Refrigerant when it comes out of the compressor, it loses part of the temperature of the water in the solar collector through a heat exchanger while the literature published in accordance with the manufacturers that the solar collector, a kind of vacuum tubes contributes to raise the pressure and temperature of the fluid cooler to reduce the consumption of energy spent on compressor. Therefore, the system described by the current not fit for domestic use within the Iraqi environmental conditions.

في منظومات التبريد ألهجينه العاملة بالطاقة الشمسية تستخدم مجمع شمسي لتحويل الطاقة الشمسية إلى مصدر حرارة لتحميص مائع التثليج الخارج من الضاغط وهذه العملية تساعد في تحول مائع التثليج من الحالة الغازية إلى الحالة السائلة في الثلثين الأعلى من المكثف بدلا من الثلثين السفلي من المكثف كما في منظومات التبريد التقليدية وهذا بدوره يقلل من الطاقة الضرورية لقياده عمليه التبريـــــــــــــد ،تم استخدام منظومة تبريد هجينه بسعة 1 طن ولمائع التبريد نوع R22 وكانت قيمه التيار المسحوب من قبل المنــــــــظومة بحــــــدود (3.9-4.2A) وهو نفس قيمه التيار المحسوب من قبل منظومة تقليدية ضمن هذه الأجواء للعراق، وبعد اخذ قراءات مختلفة لدرجات الحرارة والضغط لعده نقاط في المنظومة وجد إن مائع التثليج عندما يخرج من الضاغط فأنه يفقد جزء من حرارته إلى الماء الموجود في المجمع الشمسي عن طريق المبادل الحراري في حين إن الأدبيات المنشورة وفق الشركات المصنعة إن المجمع الشمسي وهو من النوع المفرغ الأنابيب يساهم برفع الضغط ودرجة الحرارة لمائع التثليج وذلك لتقليل استهلاك الطاقة المصروفة على الضاغط. لذلك فأن المنظومة على وصفها الحالي لاتتناسب للاستخدام المنزلي ضمن الظروف البيئية العراقية.


Article
Experimental and Theoretical Study of Vacuum Cooling System
دراسة تجریبیة ونظریة لمنظومة التبرید بالتفریغ

Authors: Ahmed A. M. Saleh --- Qussai J. Abdul Ghafour --- Luay T. Al-Rawi
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2013 Volume: 31 Issue: 14 Part (A) Engineering Pages: 2619-2631
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

A vacuum cooling system and the parameters which affect on its performancewere studied experimentally and theoretically. For the experimental study the rig wasbuilt up to studying the performance of cooling system in three cases. These casesare: Cooling water by vacuum only, cooling water in conventional method, andcooling water by vacuum with condensation.The experimental results show that the addition of a condenser to the vacuumcooling system leads to sweep of largest amount of generated vapor, also the timeconsumed for the process was decreased. The times required for cooling 45 g fromwater from temperature 29oC to 10oC for the three test cases were 4375 second, 3535second and 263 second, respectively. Vacuum cooling with condenser is a fastcooling of three systems test, which is about (13.7 times) faster than the system ofnatural convection cooling. To work properly, the existence of condenser is veryimportant in vacuum cooling. It normally removes the large amount of water vaporgeneration (about 94%).For the theoretical study, a computer program was built up by employing thegoverning equation to simulate the performance of the vacuum cooling system. Thetheoretical results indicate an acceptable agreement with the experimental results.Also, the results show that the decreasing of condenser temperature causes decreasingof cooling time according to the equation (t = 0.2031Tcd4 - 2.8958 Tcd3 + 16.406Tcd2 - 21.104 Tcd + 313.39), and increasing the evaporation surface area leads todecreasing of cooling time according to the equation (t=1/ (0.0006*Area+0.0005)),and the increasing of water mass causes in increasing of cooling time according to theequation (t=7.2667*mass+14).


Article
Heat Transfer Enhancement in Air Cooled Gas Turbine Blade Using Corrugated Passages

Authors: Dr. Emad Qasem Hussein --- Dr. Haider Nadhom Azziz --- Dr. Farhan Lafta Rashid
Journal: Journal of Petroleum Research & Studies مجلة البحوث والدراسات النفطية ISSN: 22205381 Year: 2018 Issue: 20 Pages: 52-69
Publisher: Ministry of Oil وزارة النفط

Loading...
Loading...
Abstract

In this paper, an investigation of using corrugated passages instead of circular cross section passages was achieved in conditions simulate the case in the gas turbine blade cooling using ANSYS Fluent version (14.5) with Boundary conditions: inlet coolant air temperature of 300 K with different air flow Reynolds numbers (191000, 286000 and 382000). The surrounding constant hot air temperatures was (1700 K). The numerical simulations was done by solving the governing equations (Continuity, Reynolds Averaging Navier-stokes and Energy equation) using (k-ε) model in three dimensions by using the FLUENT version (14.5). The present case was simulated by using corrugated passage of 3 m long, internal diameter of 0.3 m, 0.01 m groove height and wall thickness of 0.01 m, was compared with circular cross section pipe for the same length, diameter and thickness. The temperature, velocity distribution contours, cooling air temperature distribution, the inner wall surface temperature, and thermal performance factor at the two passages centerline are presented in this paper. The coolant air temperature at the corrugated passage centerline was higher than that for circular one by (12.3%), the temperature distribution for the inner wall surface for the corrugated passage is lower than circular one by (4.88 %). The coolant air flow velocity seems to be accelerated and decelerated through the corrugated passage, so it was shown that the thermal performance factor along the corrugated passage is larger than 1, this is due to the fact that the corrugated walls create turbulent conditions and increasing thermal surface area, and thus increasing heat transfer coefficient than the circular case.


Article
Absorbs Heat from Outside Air and Release it inside the Building by Heat Pump
تمتص الحراره من الهواء الخارجي وترسلة داخل البناية بواسطة مضخات حرارية

Author: Afreen Emad saad AL- deen افرين عماد
Journal: Journal of Engineering and Sustainable Development مجلة الهندسة والتنمية المستدامة ISSN: 25200917 Year: 2011 Volume: 15 Issue: 4 Pages: 189-204
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

A heat pump in the most basic sense, is little more than a conventional air – conditioning system that is equipped with the necessary components to cause it to reverse its running cycle, while the heat pump is operating in reverse, it absorbs heat from the air outside and releases it inside the building.
In this system Freon gas (R134) was used because it is more efficiency from the other kinds of gases that used for conditioning, and the data that produced from this system at its running time was compared with that produced from another system also used the same kind of gas.
In this work the first step is to measure the temperatures at various points in the cycle (t1-----t8) these points are:
•The temperature of (R134) at outlet from the compressor.
•The temperature of (R134) at outlet from the condenser.
•The temperature of (R134) at outlet from the expansion valve.
•The temperature of (R134) at outlet from the evaporator.
•The temperature of water at inlet to the condenser.
•The temperature of water at outlet from the condenser.
•The temperature of water at inlet to the evaporator.
•The temperature of water at outlet from the evaporator.
Also to measure the intake and compression pressures, denoted with Pv and Pc, which do not coincide with the evaporation and compression pressures, due to the pressure drops taking place in the refrigerant going through the heat exchangers.
And determine the heat in condenser and in compressor, and in evaporator.
Then determine the efficiency of Carnot’s ideal cycle to be able of compare the results with those relating to an ideal machine.

المضخة الحرارية بأبسط اوضاعها هي اصغر من منظومة مكيف الهواء التقليدية والتي تكون مزودة بالمحتويات الضرورية لتسبب انعكاس دورتها التشغيلية حيث ان المضخة الحرارية تعمل عكس هذه الطريقة تماما حيث تقوم بأمتصاص الحرارة من الهواء الخارجي وتطلقه داخل البناية حيث استخدم في هذه المنظومة غاز فريون من نوع (R134) وقد تم اختيار هذا النوع من الغاز لكونه اكثر كفاءة من غيره من الغازات بالاضافة الى ان القيم الناتجة من عمل هذه المنظومة قد تمت مقارنتها مع قيم ناتجة من منظومة اخرى مستخدم فيها غاز(R134) في هذا البحث اول خطوة نقوم بها هي قياس درجات الحرارة في نقاط مختلفة من المنظومة (t1--------t8) وهذه النقاط هي :•درجة حرارة غاز الفريون (R134) الخارج من الضاغط.•درجة حرارة غاز الفريون (R134) الخارج من المكثف .•درجة حرارة غاز الفريون (R134) الخارج من الصمام الموسع.•درجة حرارة غاز الفريون (R134) الخارج من المبخر.•درجة حرارة الماء الداخل الى المكثف.•درجة حرارة الماء الخارج من المكثف.• درجة حرارة الماء الداخل الى المبخر.•درجة حرارة الماء الخارج من المبخر. بالاضافة الى قياس الضغط عند المأخذ و الضاغط والتي تعرف ب (Pv and Pc, ) والتي ليس لها ارتباط بضغط المبخر والضاغط نسبة الى الخسارة الحاصلة بالضغط نتيجة للبـرودة التي تمر خلال المبادلات الحرارية وحساب الحرارة في المكثف والضاغط والمبخر ومن ثم حساب كفاءة دائرة كارنوت المثالية للتمكن من مقارنة النتائج مع تلك الناتجة من منظومة مثالية اخرى .

Keywords

Heat Pump --- temperature --- cooling --- cycle


Article
Employing Inner Triplet Upgrade in Cold Mass Cooling Design for Large Hadron Collider

Authors: F.M. Alshimmary --- A.F. Almaliki --- S.H. Alhadithi
Journal: Iraqi Journal of Applied Physics Letters الرسائل العراقية في الفيزياء التطبيقية ISSN: 1999656X Year: 2009 Volume: 2 Issue: 1 Pages: 19-22
Publisher: iraqi society for alternative and renewable energy sources and techniques الجمعية العراقية لمصادر وتقنيات الطاقة البديلة والمستجدة

Loading...
Loading...
Abstract

A luminosity upgrade of the CERN Large Hadron Collider (LHC) is planned to coincide with the expected end of life of the existing inner triplet quadrupole magnets. The upgraded inner triplet will have much larger heat loads to be removed from the magnets by the cryogenics system. As part of the LHC Accelerator Research Program (LARP), a design study has been completed to investigate the required characteristics of the cold mass cooling system within the framework of a design temperature profile. These characteristics are the beam pipe annulus, collar radial cooling channels, yoke radial cooling channels, yoke longitudinal cooling channels, and heat exchanger connecting pipe. Using these parameters in conjunction with energy deposition calculations, longitudinal and radial temperature profiles for an entire inner triplet are calculated and presented.


Article
The effect of using ramps with trench cylindrical holes on film cooling effectiveness
تأثير استخدام المنحدرات مع الشق القوسي المثقب على فعالية التبريد الغشائي

Authors: Falah F. Hatem --- Humam K. Jalghef --- Ahmed A. Imram
Journal: Wasit Journal of Engineering Sciences مجلة واسط للعلوم الهندسية ISSN: 23056932 Year: 2015 Volume: 3 Issue: 2 Pages: 15-27
Publisher: Wassit University جامعة واسط

Loading...
Loading...
Abstract

The effect of introducing ramp with a cylindrical slot hole on the film cooling effectiveness has been investigated experimentally and numerically. The film cooling effectiveness measurements are obtained experimentally. A test study was performed at a single mainstream with Reynolds number 76600 at three different coolant to mainstream blowing ratios 1.5, 2, and 3. Numerical simulation is introduced to primarily estimate the best ramp configurations and to predict the behavior of the transport phenomena in the region linked closely to the interaction between the coolant air injection and the hot air mainstram flow. The results showed that using ramps with trench cylindrical holes would enhanced the overall film cooling effectiveness by 83.33% compared with baseline model at blowing ratio of 1.5, also the best overall flim cooling effectevness was obtained at blowing ratio of 2 while it is reduced at blowing ratio of 3.

تم دراسة تأثير إدخال المنحدرات مع وجود شق أسطواني يحتوي على ثقوب على فعالية التبريد الغشائي عمليا ونظريا. يتم الحصول على قياسات فعالية التبريد الغشائي تجريبيا. وأجريت دراسة اختبار في التيار واحد من رقم رينولدز 76600 مع ثلاث سرع مختلفة للهواء البارد لتحقيق نسبة نفث ( 1.5 و 2 و 3( تقدم المحاكاة العددية مبدئيا" لتخمين أفضل التشكيلات للمنحدرات والتنبؤ بسلوك ظاهرة الانتقال في المنطقة القريبة جدا"من تداخل الهواء البارد المحقون مع المجرى الرئيسي للهواء الحار . أظهرت النتائج أن استخدام المنحدرات مع الشق القوسي لثقوب الاسطواني من شأنه تعزيز فعالية التبريد الغشائي بنسبة 83.33٪ مقارنة مع النموذج الأساسي لنسبة نفث 1.5 ,كذلك أفضل فعالية للتبريد الغشائي تم الحصول عليها عند نسبة نفث 2 في حين قلت فعالية التبريد عند نسبة نفث 3.

Keywords

Film Cooling --- Effectiveness --- Trench --- Ramp.