research centers


Search results: Found 2

Listing 1 - 2 of 2
Sort by

Article
Dynamic Performance Enhancement of an Armature Controlled Separately Excited D.C. Motor
تحسين الاداء الديناميكي لمحرك التيار المستمر ذو التغذيه المنفصله للفيض المغناطيسي و بالسيطره على المنتج

Author: Zainab Basheer Abdulla زينب بشير عبد الله
Journal: Al-Rafidain University College For Sciences مجلة كلية الرافدين الجامعة للعلوم ISSN: 16816870 Year: 2015 Issue: 36 Pages: 271-304
Publisher: Rafidain University College كلية الرافدين الجامعة

Loading...
Loading...
Abstract

In this paper the dynamic performance (speed regulation performance versus reference and load torque changes) of a separately excited D.C. motor is enhanced, the D.C. motor is fed by a D.C. source through a chopper which consists of GTO thyristor and free-wheeling diode. The motor drives a mechanical load characterized by inertia J, friction coefficient B, and load torque TL. The performance enhancement is achieved by using a speed control loop uses a proportional-integral (PI) controller which produces the reference signal for the current control loop and this is a (PI) current controller compares the sensed current with the reference and generates the trigger signal for the GTO thyristor to force the motor current to follow the reference. The simulation of the D.C. drive is performed using MATLAB/Simulink program version 7.10 (R2010a).

في هذا البحث قد تم تحسين الاداء الديناميكي (اداء تنظيم السرعه حسب تغير عزم الحمل) لمحرك التيار المستمر ذو التغذيه المنفصله لملفات الفيض المغناطيسي. المحرك تم تغذيته من قبل مصدر تيار مستمر و من خلال المقطع من نوع GTO و ثنائي الدوران الحر. المحرك يسوق حمل ميكانيكي ذو عزم قصور ذاتي J و معامل احتكاك B وعزم TL. ان تحسين الاداء قد تم باستعمال حلقة سيطرة السرعه والتي تستخدم المسيطر من النوع التناسبي التكاملي وهذه الحلقه تنتج اشارة المقارنه لحلقة سيطرة التيار و هذا المسيطر ايضا من النوع التناسبي التكاملي و الذى بدوره يقوم بمقارنة تيار المحرك الفعلي مع اشارة تيار المقارنه و ان ناتج المقارنه تكون اشارة القدح للمقطع GTO وذلك لجعل تيار المحرك بتتيع اشارة المقارنه. المحاكاة لسواقة التيار المستمر هذه قد تمت باستعمال برنامج الماتلاب.


Article
Study the Robustness Active Filter for a Three-Phase Power Rectifier Considering Line Frequency and Load Variations

Authors: Ali Jafer Mahdi --- Bashar Abbas Fadheel
Journal: Journal of University of Babylon مجلة جامعة بابل ISSN: 19920652 23128135 Year: 2018 Volume: 26 Issue: 1 Pages: 141-154
Publisher: Babylon University جامعة بابل

Loading...
Loading...
Abstract

Power electronic converters (e.g. AC-DC and DC-AC) produce harmonics which distorting the waveforms of voltage and current. Many research works have examined various techniques to mitigate harmonics at operating conditions (i.e. at a fixed line frequency and a specific load) such as: (i) passive filters, (ii) Current-injection converters, (iii) active filters and (iv) hybrid filters. Active filters are widely used with three-phase bridge rectifiers due to their excellent features for reducing harmonics using power switches instead of passive components that minimize the efficiency of the system. This paper investigates the robustness and the dynamic performance of active filters under the variation of line frequency and DC load. In case of using active filters, it is observed that total harmonic distortion (THD) of voltage and current waveforms is kept at IEEE Standard limits(i.e. less than 5%) under the variation of line frequency . Whilst the performance of passive filters is highly affected by the variations of line frequency and THD of voltage and current waveforms is always greater than 5% except at designed frequency, i.e. 50 Hz. Moreover the load is changed from full-load to half-load, it is observed that the dynamic response of active filters is faster than passive filters for canceling harmonics. It is worth noting that the hysteresis-current-control method is utilized for adjusting the control pulses of active filters due to its rapid dynamic responsem. Simulation results present the highest values of THD of line currents in cases: without any filters , passive filters and active filters are 24.36%, 80.79% and 3.03%, respectively.

ان مغيرات الكترونيات القدرة والتي يكون مبدأ عملها هو التغيير والتقويم تنتج التوافقيات التي تقوم بتشويه موجة الفولتية والتيار لمصدر تجهيز القدرة. عدة بحوث منشورة سعت الى استخدام تقنيات مختلفة لتقليل التوافقيات ومنها:(1- المرشحات الخاملة, 2- مغيرات حقن التيار, 3- المرشحات الفعالة, 4- المرشحات الهجينة). تستخدم المرشحات الفعالة بصورة واسعة مع المقومات ثلاثية الطور لتقليل التوافقيات باستخدام عناصر خاملة مع مفاتيح دوائر الكترونيات القدرة. يتناول هذا البحث خصائص المرشح الفعال عند تغيير تردد المصدر والحمل. حيث لوحظ ان قيمة التشوه التوافقي الكلي THD هي دائما عند الحد المسموح به (اقل من 5%) للمرشح الفعال, اما للمرشح الخامل فأن قيمة THD هي اعلى من 5% وخصوصاً لموجة التيارات عند تغيير تردد المصدر وان المرشح فقط يعمل عند التردد المصمم عنده (50Hz), وايضاً, في حالة تغيير الحمل من الحمل التام الى نصف الحمل فأن استجابة المرشح الفعال يكون اسرع من المرشح الخامل. تم استخدام تقنية المسيطر التخلفي الهستيري لتوليد نبضات المرشح الفعال. نتائج المحاكاة تبين اعلى قيم THD للتيارات في الحالات: بدون استخدام اي مرشحات، استخدام المرشحات الخاملة واستخدام المرشحات الفعالة هي كالتالي: 24.36% ، 80.79% و 3.03%.

Listing 1 - 2 of 2
Sort by
Narrow your search

Resource type

article (2)


Language

English (2)


Year
From To Submit

2018 (1)

2015 (1)