Experimental Study Of Air Flow Rate Effects On Humidification Parameters With Preheating And Dehumidification Process Changing

Author: Ayad Tareq Mustafa
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2011 Volume: 17 Issue: 4 Pages: 979-992
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

This research study experimentally the effect of air flow rate on humidification process parameters. Experimental data are obtained from air conditioning study unit T110D. Results obtained from experimental test, calculations and psychometrics software are discussed. The effect of air flow rate on steam humidification process parameters as a part of air-conditioning processes can be explained according to obtained results. Results of the steam humidification processes (1,2) with and without preheating with 5A and 7.5A shows decreasing in dry bulb temperature, humidity ratio, and heat add to moist air with increasing air flow rate, but humidification load, and total energy of moist air increase with increasing air flow rate in the testing tunnel. The steam humidification process (1) with dehumidifying coil shows increase in dry bulb temperature, humidity ratio, humidification load, and heat add to moist air with increasing air flow rate in the testing tunnel, but the total energy decrease as air flow rate increase. These obtained results can be beneficial for controlling comfort air-conditioning processes in buildings.

هذا البحث يدرس تأثير نسبة جريان الهواء عمليا على معاملات عملية الترطيب. البيانات التجريبية تم الحصول عليها من جهاز وحدة دراسة تكييف الهواء T110D. تم مناقشة نتائج الحسابات والبرنامج الحسابي المصردي. تأثير نسبة جريان الهواء على معاملات عملية الترطيب بالبخار يمكن توضيحها في النتائج المستحصلة كجزء من عمليات تكييف الهواء. نتائج الترطيب بالبخار (2,1) مع/ بدون تسخين ابتدائي 5A و7.5A اظهرت نقصان في درجة حرارة البصلة الجافّة, نسبة الترطيب, والحرارة المضافة للهواء الرطب بازدياد نسبة جريان الهواء, ولكن حمل الترطيب والطاقة الكليّة للهواء الرطب تزداد بازدياد نسبة جريان الهواء في قناة الاختبار. عملية الترطيب بالبخار (1) مع وجود ملف سحب الرطوبة اظهرت زيادة في درجة حرارة البصلة الجافّة, نسبة الترطيب, حمل الترطيب, والحرارة المضافة للهواء الرطب بازدياد نسبة جريان الهواء في قناة الاختبار, ولكن نقصان الطاقة الكليّة بازدياد نسبة جريان الهواء. هذه النتائج المستحصلة يمكن الاستفادة منها في نظام سيطرة عمليات تكييف الهواء في الابنية.


Article
Performance of a Plate Fin and Tube Dehumidifying Coil Using Entropy GenerationMethod
اداء ملف ازالة الترطيب نوع انبوب- زعنفه مستويه بأستخدام طريقة تولد الأنتروبيه

Authors: Alaa Ruhma Kazim --- Eaman Hassan Muhammed
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2009 Volume: 27 Issue: 16 Pages: 3112-3128
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

The objective of the present work is to apply the concept of entropy generation method to evaluate the performance of a plate fin and tube dehumidifying coil. The present study provides an analytical method to model the working and performance of this coil as an independent part from the system without modeling the other parts that the system consisted of under wet and dry surface conditions for variable operating parameters. A comparison was made between the traditional effectiveness of the coil and the entropy generation modelto evaluate the performance of the coil for variable conditions. The study found that the entropy generation algorithm is more efficient and more sensitive to parameters change than traditional effectiveness to describe the performance of a dehumidifying coil depending onthe design and operating parameters. The combination of operating parameters of the coil such as air velocity, air wet bulb temperature, air dry bulb temperature, air relative humidity and heat load capacity affected the performance of the coil and the variable operatingparameters lead to variable performance, so the air velocity should be varied according to the state of entering air and the total space load during operation time to compensate the loss in performance and to save power consumed.

لأيجاد اداء ( Entropy Generation) الهدف من الدراسه هو تطبيق مفهوم طريقة تولد الأنتروبیه ملف ازالة الترطيب نوع انبوب- زعنفه مستويه. الدراسه الحاليه تقدم طريقه تحليليه لمماثلة عمل وأداء هذا الملف كوحده مستقله عن المنظومه بدون مماثلة الأجزاء الأخرى التي تتكون منها المنظومه في حالةجفاف او رطوبة سطح الملف ولعدة متغيرات تشغيليه. تمت مقارنة الفعاليه التقليديه للملف مع نموذج تولد الأنتروبيه لوصف اداء الملف في ظروف متغيره. الدراسه وجدت ان طريقة تولد الأنتروبيه اكثر كفاءه وأكثر حساسيه للمتغيرات من الفعاليه التقليديه لوصف اداء ملف ازالة الترطيب اعتمادا على المتغيراتالتشغيليه والتصميميه. مجموعه المتغيرات التشغيليه للملف مثل سرعه الهواء , درجة الحراره الرطبه , درجة الحراره الجافه , الرطوبه النسبيه والحمل الحراري تؤثر على اداء الملف وهذه العوامل التشغيليه المتغيره تؤدي الى تغير الأداء لذلك فأن سرعة الهواء يجب ان تتغير طبقا الى حالة الهواء الداخل والحمل الحراري خلال وقت التشغيل لتعويض النقصان بألأداء ولتوفير الطاقه المستهلكه.