research centers


Search results: Found 10

Listing 1 - 10 of 10
Sort by

Article
USING NETWORK RECONFIGURATION AS A TOOL FOR MITIGATING VOLTAGE SAGS IN PRACTICAL DISTRIBUTION SYSTEMS
استخدام إعادة ترتيب الشبكة كطريقة للتخفيف من ضعف الفولتية في أنظمة التوزيع العملية

Author: Balasim Mohammed بلاسم محمد حسين
Journal: DIYALA JOURNAL OF ENGINEERING SCIENCES مجلة ديالى للعلوم الهندسية ISSN: 19998716/26166909 Year: 2010 Volume: Engineering Sc. Conference Issue: First Pages: 463-472
Publisher: Diyala University جامعة ديالى

Loading...
Loading...
Abstract

ABSTRACT:- Voltage magnitude is one of the major factors that influence the quality of power supply. In this paper a practical method is presented for mitigating voltage sag in power distribution systems by means of network reconfiguration. The method initially identifies the weak areas in the system when it is subjected to faults in the system. Then it tries to reconfigure the network by locating the weak areas as far away as possible from the main source. Network reconfiguration is implemented by changing the opening and closing switching status of the switches in a network. A practical test distribution system is analyzed and reconfigured to illustrate the applicability of the proposed method. The results proved that the proposed voltage sag mitigation method can improve the system voltage profile during faults and hence decrease the use of voltage sag mitigation devices. Such a technique can be used to improve power quality and reliability of power distribution networks.Keywords:- power, distribution network, reconfiguration, voltage sag.

الخلاصة مقدار الفولتية هو واحد من العوامل الرئيسية التي تؤثر على نوعية القدرة المجهزة.في هذا البحث تم إيجاد طريقة عملية للتخفيف من ضعف الفولتية في نظم توزيع القدرة بواسطة إعادة ترتيب الشبكة.الطريقة في بدايتها تحدد مناطق الضعف في النظام عندما يتعرض النظام إلى خطأ. بعدها تقوم بإعادة ترتيب الشبكة لجعل مناطق الضعف ابعد ما يمكن عن المصدر الرئيسي. حيث عن طريق تغير حالات الفتح والإغلاق للمفاتيح الموجودة في الشبكة يتم إعادة ترتيب الشبكة.وتم تحليل وإعادة ترتيب نظام اختبار عملي لتوضيح تطبيق الطريقة المقترحة. أثبتت النتائج ان الطريقة المقترحة للتخفيف من ضعف الفولتية تستطيع تحسين فولتية النظام أثناء حدوث الأخطاء وبالتالي التقليل من استخدام أجهزة تخفيف ضعف الفولتية. حيث يمكن استخدام هذه التقنية لتحسين نوعية القدرة وموثوقية شبكات توزيع القدرة.


Article
Earth Fault Protection Failure in the Distribution Transformer 11/0.4 kV Supply

Authors: Thamir M. Abdul-Wahhab --- Mohammed S. Jasim
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2018 Volume: 36 Issue: 4 Part (A) Engineering Pages: 391-400
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

This research studies a miss-coordination problem in the protection of 11 kV distribution network in Iraq. The problem arises when an underground cable is exposed to an earth fault at a location between the High Rupturing Capacity (HRC) fuses and the high voltage windings of the distribution transformer. In this case, the protective relay of the main circuit breaker of the feeder operates at a time faster than the HRC fuses of the faulty transformer. The distribution network considered in this work is an underground 11kV distribution network at Al-Rusafa General Directorate geographical region in Baghdad city. The problem was studied using mathematical analysis and software analysis. The mathematical results and the analysis of the simulated network using CYME 7.1 program show that the relay will operate before the HRC fuses as a response to an earth fault occurrence on that part of the network. To solve this problem several solutions are proposed and discussed in this research.


Article
A Reliable Load Flow Method for Radial Distribution Systems
طريقة موثوقة لحساب سريان الحمل في منظومات التوزيع الشعاعية

Authors: Kassim A. Ali Al-Anbarri --- Wafaa Saeed Majeed
Journal: Journal of Engineering and Sustainable Development مجلة الهندسة والتنمية المستدامة ISSN: 25200917 Year: 2012 Volume: 16 Issue: 2 Pages: 248-265
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

This paper presents a reliable load flow algorithm for radial distribution systems. The proposed algorithm exploits the particular topological structure of the radial distribution system. A system of algebraic equations which describe the steady state performance of the radial system is derived based on the relation between the nodal currents and the lateral currents. Different types of load models can be easily handled. The presented method is tested on several radial distribution systems. The results obtained reveal the robustness and effectiveness of the proposed algorithm for solving load flow problem in radial distribution system.

يقدم هذا البحث خوارزمية موثوقة لحساب سريان الحمل في منظومات التوزيع الشعاعية. تستخدم الخوارزمية المقترحة بشكل فعال طبيعة تركيب منظومات التوزيع الشعاعية. تم اشتقاق منظومة من المعادلات الجبرية التي تصف سلوك المنظومة الشعاعية في الحالة المستقرة استنادا إلى العلاقة التي تربط تيارات العقد مع تيارات فروع المنظومة. يمكن تناول مختلف نماذج الحمل في الخوارزمية بسهولة. تم اختبار الطريقة المقترحة على عدد من منظومات التوزيع الشعاعية. ان النتائج المستحصلة تظهر كفاءة ومتانة الخوارزمية المقترحة لحل مسائل سريان الحمل في منظومات التوزيع الشعاعية.


Article
Harmonic Analysis of a Power Distribution Network in Baghdad City

Author: Thamir M. Abdul-Wahhab
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2016 Volume: 34 Issue: 6 Part (A) Engineering Pages: 1088-1103
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

In electrical distribution systems, capacitors are used for reactive power compensation and reducing active power losses. With the presence of harmonic distortion the installation of shunt capacitors will amplify the harmonics distortion level. The objective of this study is to investigate the effect of capacitor placement on a certain feeder in AL_AMILdistribution network in Baghdad city with the presence of harmonics generated by a large non-linear load such as an ARC furnace. The CYMDIST software package was used for the implementation of this study. The results show the effectiveness of optimal capacitor placement on reactive power compensation, enhancing voltage profile, relieving the lines from over load conditions, and reducing active power losses. However the total harmonic distortion level is increased and methods are required for mitigation the harmonic effects. Several passive filters have been considered to tune out the harmonics; among these the double tuned filter has proven to be the most effective one for our particular case.


Article
Exponential Based Load Model for Baghdad Distribution Feeder
تمثيل الاحمال بنموذج ذو صيغة أسية لشبكة مغذي

Author: Azhar M. Al-Rawi أزهر مجيد عبد الحميد الراوي
Journal: Journal of Al-Ma'moon College مجلة كلية المأمون ISSN: 19924453 Year: 2013 Issue: 21 Pages: 203-211
Publisher: AlMamon University College كلية المامون الجامعة

Loading...
Loading...
Abstract

Distribution feeders in Baghdad comprise different load classes, those classes differ in load component, characteristics and sensitivity to network variables. In view of this fact, applying any dynamic study to those feeders requires proper modeling of loads, otherwise, unfavorable results obtained. Realistic load component varies in relation to both system voltage and frequency, and this variation is related to load type and sensitivity, that may alter studies by deliveringnon -desired results. Proper modeling leads to desirable decisions,correct and realistic results, and undoubtedly will reduce efforts and expense of the un-justified network modifications. In this work, residential load mix feederisstudied,the load characteristic is acquired, and thennetwork componentsand loads are presented using voltage-frequency dependable exponential load model. The results obtained arerecommended to be implemented in distribution network studies and dedicated software within Baghdad network.

تتضمن مغذيات شبكة توزيع كهرباء بغداد أنواعاً متنوعة من الاحمال تختلف عن بعضها بالسلوك والخصائص والحساسية لمتغيرات النظام . ان تنفيذ اية دراسات واقعية على هذه المغذيات يتطلب التمثيل الامثل للاحمال وبخلافه تنتج هذه الدراسات نتائج غير مثالية.تتغير الاحمال الواقعية عند تذبذب الفولتية وتردد النظام ويعتمد هذا التغير على نوع الحمل وحساسيته ومن الممكن ان يؤثر في الدراسات الديناميكية لانظمة التوزيع. ان التمثيل الامثل للاحمال يقود لقرارات مثلى ونتائج واقعية صحيحة وبالتاكيد يقلل من كلفة التطوير والتنمية غير المبررة للشبكات في حال تمثلها بشكل ثابت.تضمن هذا البحث دراسة نموذج لمغذي ذي حمل سكني ,حيث تم تسجيل خصائص الحمل ومن ثم تمثيله باستخدام نموذج أسي مع الاخذ بنظر الاعتبار تاثير تغير الفولتية والتردد على تلك الاحمال , وخرجت هذه الدراسة بنتائج واقعية يوصى باستخدامها في دراسات شبكة توزيع كهرباء بغداد وبرامجياتها.


Article
Optimal Placement of Distribution Generating in Distribution System Based on Cost worth & System Reliability indices.
تحديد الموقع الامثل للمولدات الموزعة في نظم التوزيع على اساس دلائل كلفة قطع التجهيز ووثوقية النظام

Author: Dr. Wafaa Saeed د. وفاء سعيد مجيد
Journal: Univesity of Thi-Qar Journal مجلة جامعة ذي قار العلمية ISSN: 66291818 Year: 2016 Volume: 11 Issue: 2 Pages: 1-22
Publisher: Thi-Qar University جامعة ذي قار

Loading...
Loading...
Abstract

Electrical power systems include three functional areas: generation, transmission and distribution systems. Evaluate the reliability of the whole system is very complex so the present research is limited on evaluate the reliability of radial distribution system. Since the demand loads have continuously growth and uncertainties it became one of the important things to be observed, so that we can forecast an accurate demand loads in the future .To ensure the continuity of providing demand loads and the possibility of covering the expected increase demand the technology of injected Distributed Generation in a radial distribution system through circuit breaker was adoption. DG works to generate energy to cover the increased in demand loads or to compensate the shortfall in generation during a Failure. To enhances the reliability of the test system optimal location and size of DG should be identifies. Basic reliability indices for load points and the overall system have been developed. A additional reliability (i.e. cost worth& System Reliability) indices are suggested. The cost worth indices serve as a guide to locate position where reliability needs to be supported. The suggested approach has been tested on Roy Billinton Test System 6 bus with four radial feeders. The Results that we got from this approach clearly shows the best location and sizing of DG and so support the reliability of the system.

نظم القدرة الكهربائية تشمل ثلاث مناطق وظيفية: نظم التوليد والنقل والتوزيع ,وحيث ان تقييم وثوقيه المنظومة بأكملها عملية معقدة جداً تحدد البحث الحالي بتقييم وثوقيه منظومة توزيع شعاعية. ان الاحمال المربوطة للشبكة تتنامى بشكل مستمر ولامركزي وعليه اصبح التوقع للزيادة المستقبلية في الطلب على الطاقة من الامور الواجب مراعاتها لضمان استمرارية التجهيز في حالات الخروج القسري لا حدى الوحدات التوليدية او حدوث زيادة مفاجئة بالطلب على الطاقة اعلى من الطاقة التصميمة. من التقنيات المعتمدة تقنية حقن مولد كهربائي مع قاطع دورة للشبكة عند احد المغذيات على ان يتم فصلة عن الشبكة حال رجوع الحمل الى قيمته الاعتيادية. اضافة مولد كهربائي الى منظومة التوزيع يعزز من وثوقيه التجهير بشرط ان يكون المولد المضاف بالمكان والحجم الامثل وذلك من خلال احتساب دلائل وثوقيه المنظومة والدلائل المتعلقة بكلفة قطع التجهيز. تم اختبار الطريقة المقترحة على منظومة توزيع شعاعية مخصصة للأغراض التعليمية بواقع (6) عموميات و(4) مغذيات شعاعية واشارت النتائج الى ان اختيار الموقع والحجم الامثل يعزز من وثوقية النظام .


Article
An Imperialist Competitive Algorithm for Sitting and Sizing of Distributed Generation in Radial Distribution Network to Improve Reliability and Losses Reduction

Authors: Farzaneh Ostovar --- Mahdi Mozaffari Legha
Journal: Iraqi Journal for Electrical And Electronic Engineering المجلة العراقية للهندسة الكهربائية والالكترونية ISSN: 18145892 Year: 2013 Volume: 9 Issue: 2 Pages: 59-66
Publisher: Basrah University جامعة البصرة

Loading...
Loading...
Abstract

Distributed Generation (DG) can help in reducing the cost of electricity to the costumer, relieve network congestion and provide environmentally friendly energy close to load centers. Its capacity is also scalable and it provides voltage support at distribution level. Hence, DG placement and penetration level is an important problem for both the utility and DG owner. The Optimal Power Flow (OPF) has been widely used for both the operation and planning of a power system. The OPF is also suited for deregulated environment.Four different objective functions are considered in this study: (1) Improvement voltage profile (2) minimization of active power loss (3) maximum capacity of conductors (4) maximization of reliability level. The site and size of DG units are assumed as design variables. The results are discussed and compared with those of traditional distribution planning and also with Imperialist competitive algorithm (ICA).


Article
SIMULATION AND CONTINGENCY ANALYSIS OF A DISTRIBUTED NETWORK IN IRAQ
محاكاة وتحليل الطوارئ لشبكة توزيع في العراق

Authors: Thamir M. Abdul-Wahhab --- Omar Ali Abdullah
Journal: Journal of Engineering and Sustainable Development مجلة الهندسة والتنمية المستدامة ISSN: 25200917 Year: 2016 Volume: 20 Issue: 4 Pages: 238-268
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

This paper presents the contingency analysis to study the impact of forced or planned outageson electrical distribution system. The mathematical modeling of contingency analysis includes; the loadflow analysis and the power restoration analysis. The power restoration is formulated as a constrainedmulti-objective optimization problem, based on the ranking search method. The method performs loadflow simulations and utilizes the analytical information obtained to maximize the amount of total powerrestored and to minimize the number of required switching operations.In this work the contingencyanalysis is based on the advanced CYMDIST software as a tool for the simulation of a distributionnetwork and performing the required analysis. CYMDIST software is practical and efficient analysissoftware used by many electrical companies worldwide as well as by the Iraqi ministry of electricity. Thedistribution network simulation and contingency analysis proposed in this paper were implemented onAl_Amereah 11 kV network which is a part of Baghdad city distribution network. The results show thatfull power restoration under contingency conditions after fault isolation without violating constraints wasachieved in three steps: optimal switching, addition of a feeder, and optimal capacitor placement.

تقدم هذه الورقة تحليل الطوارئ لدراسة أثر انقطاع التيار القسري أو المخطط له على منظومة التوزيع الكهربائية. التمثيل الرياضي لتحليل الطوارئ يشتمل على تحليلات سريان الحمل و تحليلات استعادة القدرة الكهربائية. استعادة القدرة الكهربائية تم صياغتها على شكل مسألة أمثلية متعددة الاهداف مقيدة,وذلك بالاستناد الى طريقة البحث حسب الترتيب الطبقي .ranking search method هذه الطريقة تعمل محاكاة لسريان الحمل وتستخدم المعلومات التحليلية التي يتم الحصول عليها لاستعادة اعظم قدرة كهربائية للمستهلكين وبأقل عدد من عمليات التبديل (فتح وغلق المفاتيح).في هذا العمل استند تحليل الطوارئ على برامجياتCYMDIST المتقدمة كأداة لمحاكاة شبكة التوزيع الكهربائية وإجراء التحليلات المطلوبة. برنامج CYMDIST برنامج تحليل عملي وفعال يستخدم من قبل العديد من شركات الكهرباء في جميع أنحاء العالم، وكذلك من قبل وزارة الكهرباء العراقية. محاكاة شبكة التوزيع الكهربائية وتحليل الطوارئ المقترح في هذه الورقة تم تنفيذه على شبكة توزيع كهرباء العامرية 11 kV والتي تمثل جزءاً من شبكة توزيع كهرباء بغداد-الكرخ. وتشير النتائج أن استعادة الخدمة كاملة بعد عزل العطل, بدون أي انتهاك للقيود في ظل حالة الطوارئ, تم تحقيقه في ثلاث خطوات: التبديل (فتح وغلق المفاتيح) الامثل, اضافة مُغذي, والتوزيع الامثل للمتسعات.


Article
Reliability Evaluation of Al_Mansour 11kV Distribution Network in Baghdad City

Authors: Riyadh A. Ahmed --- Thamir M. Abdul-Wahhab
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2018 Volume: 36 Issue: 3 Part (A) Engineering Pages: 304-314
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

Reliability is a key aspect of power system design and planning. This work aims to evaluate and improve the reliability of a power distribution network in Baghdad city. The minimal cut set method has been adopted for reliability evaluation. Evaluating the reliability requires calculating and evaluating a set of reliability indices. In this research, the reliability indices are calculated for Al_Mansour 11kV distribution network in Baghdad city. According to these indices several improvements have been proposed and simulated on the network as follows:Adding N/C manually switches in the network for isolating fault areaand restoring the service to the remaining parts.Adding N/O manually switches to interconnect feeders and providealternative supply.Replacing the manually switches by remotely controlled or fullyautomated switches with fault indicators to reduce interruption times.Replacing the overhead lines by underground cables to reduce the faultrates. The software CYMDIST version 7.1 has been used as a tool for the simulation of the distribution network and performing the required analysis.


Article
Planning of Distribution Networks in Baghdad City
تخطيط شبكات التوزيع في مدينة بغداد

Authors: Dr. Thamir M. Abdul-Wahhab د. ثامر محمد عبد الوهاب --- Adeeb Nasser Hussein أديب ناصر حسين
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2015 Volume: 21 Issue: 2 Pages: 66-86
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Planning of electrical distribution networks is considered of highest priority at the present time in Iraq, due to the huge increase in electrical demand and expansions imposed on distribution networks as a result of the great and rapid urban development.Distribution system planning simulates and studies the behavior of electrical distribution networks under different operating conditions. The study provide understanding of the existing system and to prepare a short term development plan or a long term plan used to guide system expansion and future investments needed for improved network performance.The objective of this research is the planning of Al_Bayaa 11 kV distribution network in Baghdad city based on the powerful and efficient CYMDist software as a tool for the simulation and analysis of the network.The planning method proposed in this thesis is to reach the optimum operating conditions of the network by combining the network reconfiguration in sequence with the insertion of capacitors with optimal sizing and locations. The optimum performance of the network is achieved by reducing losses, improving voltage profile and alleviating overload for transformers and cables.

يعد تخطيط شبكات التوزيع الكهربائية من الأولويات في الوقت الحاضر في العراق نظراً للزيادة الهائلة في الأحمال الكهربائية و التوسعات المفروضة على الشبكات نتيجة التطور العمراني الكبير والسريع.تخطيط منظومة التوزيع يحاكي ويدرس سلوك شبكات التوزيع الكهربائية في ظل ظروف تشغيل مختلفة. الدراسة توفر فهم المنظومة القائمة وإعداد خطة تنموية قصيرة الأجل أو خطة طويلة المدى تستخدم لتوجيه التوسع في المنظومة والاستثمارات المستقبلية اللازمة لتحسين أداء الشبكة.الهدف من البحث هو تخطيط شبكة توزيع كهرباء البياع kV 11 في مدينة بغداد استناداً الى برمجيات CYMDist ذات القدرة والكفاءة العالية كأداة لتمثيلها حاسوبياً و اجراء التحليلات عليها.ان طريقة التخطيط المقترحة في هذه الأطروحة للوصول الى حالة الأداء الأمثل للشبكة هي بأجراء عملية تغيير طوبوغرافية الشبكة بالتعاقب مع ادخال متسعات بسعات محسوبة وفي اماكن مثالية في منظومة التوزيع. ويتحقق الأداء الأمثل للشبكة بتقليل المفاقيد, وتحسين الجهد (voltage profile) ومعالجة مشكلة الحمل الزائد للمحولات والمغذيات.

Listing 1 - 10 of 10
Sort by
Narrow your search

Resource type

article (10)


Language

English (9)

Arabic and English (1)


Year
From To Submit

2018 (2)

2016 (3)

2015 (1)

2013 (2)

2012 (1)

More...