research centers


Search results: Found 184

Listing 1 - 10 of 184 << page
of 19
>>
Sort by

Article
The Characteristic Performance of Fluidized bed Ion Exchange
دراسة محددات اداء العمود الايوني ذو الطبقة المسيلة

Authors: Malik M. Mohamed مالك مصطفى --- Nahidh W. Kaseer ناهض وديع قيصر --- Iman Haider Mahdi ايمان حيدر مهدي
Journal: AL-NAHRAIN JOURNAL FOR ENGINEERING SCIENCES مجلة النهرين للعلوم الهندسية ISSN: 25219154 / eISSN 25219162 Year: 2009 Volume: 12 Issue: 1 Pages: 38-47
Publisher: Al-Nahrain University جامعة النهرين

Loading...
Loading...
Abstract

The aim of this work is to study the characterization of ion exchange in important characteristics (i.e., breakthrough time and exchange capacity) by investigation the performance of cation exchange column subjected to makeup solution in term of three different parameter (i.e., bed depth 5-45cm, NaCl salt concentration100-2000 ppm and feed flow rate 9.5-26.5l/h). Two second order polynomial model are proposed with Box Wilson composite rotatable design. The experimental result had shown an efficient performance of using ion exchange column with strong acid cation exchange resin in fluidized mode operation which given maximum breakthrough time and higher exchange capacity means the rate of exchange is very rapid to completed the removing of all undesired ions at a condition of low bed depth, high NaCl concentration and high feed flow rate

يهدف البحث المقدم الى دراسة العوامل المؤثرة في اداء المبادلات الايونية من خلال قياس خاصيتين مهمتين هما زمن الاستنفاذ وقابلية التبادل عن طريق بحث اداء عمود للمبادلات الايونية الموجبة معرض لمحاليل مياه محضرة مختبريا من خلال ثلاثة متغيرات مختلفة (ارتفاع الطبقة 5- 45 سم , تركيز محلول ملحي من كلوريد الصوديوم 100-2000 جزء بالمليون ومعدل جريان المغذي 9,5- 26,5 لتر/ساعة).ُافترضت معادلتان متعددة الحدود من الدرجة الثانية واوجدت حدودها بطريقة بوكس ويلسن للتحليل الارتدادي اللاخطي .وقد اظهرت النتائج العملية كفاءة استخدام عمود المبادل الايوني الموجب الحامضي القوي بطريقة الطبقة المسالة والذي يعطي اعلى زمن للاستنفاذ واعلى قابلية للتبادل والذي يعني ان معدل التبادل سريع جدا للقيام باكمال ازالة جميع الايونات غير المرغوبة تحت ظروف تشغيلية اقل ارتفاع للطبقة,اعلى تركيز لكلوريد الصوديوم واعلى معدل جريان للمغذي.

Keywords

Fluidization --- Ion Exchange


Article
Diagnosis and Assessment of Severity of Neonatal Hyperbilirubinæmia in Babylon Governorate, Incorporating Serum Albumin Level As A Sensitive Predictor of Outcome

Authors: Ameerah MA Al Hassan أميرة الحسن --- Mazin J. Mousa مازن جعفر موسى --- Safa W. Azeez صفاء عزيز
Journal: Al-Qadisiyah Medical Journal مجلة القادسية الطبية ISSN: 18170153 Year: 2015 Volume: 11 Issue: 20 Pages: 239-244
Publisher: Al-Qadisiyah University جامعة القادسية

Loading...
Loading...
Abstract

Neonatal jaundice is a common health problem in Iraqi neonates and oriental populations in general. Proper diagnosis and management is crucial to prevent brain damage by high concentrations of bilirubin (kernicterus). Neonatal jaundice is also regarded as the most common cause of hospitalization of neonates. It is widely agreed that the causes of neonatal jaundice is alteration of a panel of physiological factors including rapid postnatal destruction of excess red blood cells, derangement of liver clearance function and prematurity.This study was designed to reveal the importance of determining serum albumin level as a predictor of liver function in neonates with jaundice. Sixty-four patients were included in this study during a period of four months. A ratio between bilirubin and albumin levels (B/A ratio) was depicted. A B/A ratio of < 2 showed no risk of exchange transfusion as a treatment modality in all four patients aged 5-12 days, noting that there are no neonates aging 2-5 days with a B/A ratio of < 2, reflecting the accelerated course in this age group. A ratio > 4 carried a high risk of exchange transfusion (18 out of 23 in those aging 5-12 days). The grey zone of B/A ratio lying between 2-4 needed further follow up and more clinical determinants to be treated properly, only 5 out 21 were treated by exchange transfusion aging 5-12 days, while only 1 out of 8 aging 2-5 days was subjected to exchange transfusion. It is clear that the B/A ratio is a good indicator of the severity of neonatal jaundice, predicting the modality of treatment options.

يعد اليرقان الولادي من المشاكل الصحية الشائعة في حديثي الولادة في العراق و الشرقيين بشكل عام . انالتشخيص و العلاج السليمين يعتبران من أهم العوامل لمنع حدوث تلف في الدماغ بسبب التركيزات العالية منالبيليروبين ) اليرقان ( . ويعتبر يرقان حديثي الولادة أيضا هو السبب الأكثر شيوعا لدخول المستشفى فيالاطفال حديثي الولادة. ومن المتفق عليه على نطاق واسع أن أسباب اليرقان الولادي هو تغييرات في مجموعةمن العوامل الفسيولوجية بما في ذلك التحطيم السريع للفائض من خلايا الدم الحمراء، و اضطراب وظيفة الكبد والولادةالمبكرة.وقد تم تصميم هذه الدراسة بهدف الكشف عن أهمية تحديد مستوى الزلال في الدم باعتباره مؤشرا منوظائف الكبد في حديثي الولادة مع اليرقان. أدرج أربع وستون مريضا في هذه الدراسة خلال فترة أربعة أشهر.تم احتساب النسبة بين البيليروبين و بين مستويات الزلال )نسبة B / A (. أظهرت هذه الدراسة ان )نسبة B / A )أقل من 9 لا تحمل اية خطورة لنقل الدم التبادلي كطريقة للعلاج في جميع المرضى الذين تتراوح أعمارهم بين5 9 أيام أربعة ، و أيضا في جميع المرضى الأربعة الذين أعمارهم تراوحت بين 29 5 أيام . بينما أظهرت - -)نسبة B / A ( أكثر من 4 احتمالية عالية لنقل الدم التبادلي ) 21 من أصل 93 في المرضى بعمر 29 5 يوما(. و -أعتبرت المنطقة الحرجة الواقعة بين ) 4 9 ( بحاجة إلى مزيد من المتابعة و معطيات سريرية اضافية، فقط 5 من -أصل 92 وعولجوا عن طريق نقل الدم التبادلي للمرضى بعمر 29 5 يوم ، في حين عولج مريض واحد فقط من -أصل 1 بعمر 5 9 يوم بنقل الدم التبادلي. ومن الواضح أن )نسبة - B / A( تعد مؤشرا جيدا لشدة اليرقان الولادي ومن العوامل المحددة لطريقة العلاج.


Article
The Characteristics of Vortex Spray Countercurrent Mass Exchange Device (VSCMED)

Authors: Sklabinskyy Vsevolod Ivanovych --- Abdullah Jalal Mohammed --- Mohammed Nahdim Gasim
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2011 Volume: 29 Issue: 15 Pages: 3211-3223
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

The article contains the results of the efficiency research of vortex dispersing countercurrent mass exchange device performance. There are recommendations given on the basis of analysis of liquid jet and liquid drops movement to assess the mass exchange surface. Processes and Equipment of Chemical and Petroleum Refineries Department of Sumy State University has carried out a great research to design newconstructions of vortex mass exchanged devices with countercurrent flow of gas and drop flows.


Article
Synthesis, Characterization of polyacrylamide as chelating agent for some metal ions

Author: Asmahan A.Abdulla , Hassan T. Abdulsahib and Nadhum A.NAwad
Journal: Journal of Basrah Researches (Sciences) مجلة ابحاث البصرة ( العلميات) ISSN: 18172695 Year: 2006 Volume: 32 Issue: 1A Pages: 75-80
Publisher: Basrah University جامعة البصرة

Loading...
Loading...
Abstract

A polyacrylamide was prepared by applying the solution technique used for synthesis of organic polymer. It was characterized by different techniques such as elemental analysis , Infrared spectroscopy and thermal analysis .The extracting efficiency of the resin was studied toward several metal ions from their diluted solutions (50ppm) by atomic absorption spectrometry .The effect of pH and treatment time on the chelating efficiency of the resin was examined and the optimum conditions were found, the chelating efficiency of the resin decrease with pH less than 1.5 and from 1.5 to 7.5 above that the resin became soluble. The loading capacities of the resin for Zn2+,Cd2+,Cu2+and Pb2+ ions were found to be 1.40,1.0,0.62 and 0.42 mg ion/gm resin respectively. The recovery efficiency of these ions was also studied as a function of treating time and the pH of the acidic eluent, and it was found to be in the sequence of Zn2+>Cd2+>Cu2+>Pb2+.

في الدراسة الحالية تم تحضير راتنج البولي اكريل امايد بطريقة تحضير البوليمرات العضوية ،تم تشخيص هذا الراتنج باستخدام تقنيات التحليل الحراري،التحليل العنصري ومطيافية الأشعة تحت الحمراء . تم دراسة كفاءة الراتنج في استبدال عدد من الايونات المعدنية من محاليلها المخففة (50 جزء بالمليون )بإتباع تقنية الامتصاص الذري و دراسة تأثير كل من الحامضية و زمن المعاملة على كفاءة الراتنج التبادلية حيث وجد أن الكفاءة الاستبدالية للراتنج تجاه الايونات المدروسة كالأتي:الزنك> الكادميوم> النحاس>الرصاص إذ تم حساب سعة تحمل الراتنج لكل ايون فكانت 0.42،0.62،1.0،1.4 ملغم ايون /غرام من الراتنج على التوالي و بذلك فان الراتنج أبدى كفاءة عالية في الاستبدال تجاه تلك الايونات، حيث إن هذه الكفاءة تعتبر دالة مع الزمن و الدالة الحامضية من ناحية أخرى درست كفاءة استعادة الايونات من الراتنج بمعاملتها مع محلول حامض الهيدروكلوريك المخفف وقد وجد أن استعادة هذه الايونات حسب الترتيب الآتي: الزنك> الكادميوم> النحاس>الرصاص .


Article
Neonatal Polycythemia: Risk Factors, Clinical Manifestation and Treatment Applied

Authors: Sawsan Sati Abbas --- Hamed Fakhri Fayadh
Journal: Iraqi Academic Scientific Journal المجلة العراقية للاختصاصات الطبية ISSN: 16088360 Year: 2013 Volume: 12 Issue: 3 Pages: 390-395
Publisher: The Iraqi Borad for Medical Specialization المجلس العراقي للاختصاصات الطبية

Loading...
Loading...
Abstract

BACKGROUND: Polycythemia is defined as a venous hematocrit above 65%.Polycythemia is sometimes associatedwith hyper viscosity of blood .The etiology of polycythemia is related either to intra-uterine hypoxiaor secondary to fetal transfusion. Increased viscosity of blood is associated with symptoms of hypoperfusion.Clinicalfeaturesrelatedtohyperviscositymayaffectallorgansystems. OBJECTIVE: To evaluate the prevalence of polycythemia among neonates who were admitted to the nursery careunit, to evaluate the difference between peripheral and central hematocrit (PCV) and to have an ideaabout the main presentation and modes of treatment of polycythemia. PATIENTS AND METHODS: A case – control study was done in the nursery care unit of AL - Kadhyimia Teaching Hospital , onehundred neonates (50 polycythemic and 50 control healthy neonates ) were taken , for each neonates ,information regarding (name ,age , sex , gestational age , mode of delivery , body weight ,length, headcircumference , clinical presentation and risk factors ) were taken, investigations includinghematocrite (PCV) , random blood sugar and total serum bilirubin were done for all neonates. RESULTS: The prevalence of neonatal polycythemia was (2.2%) , male was affected more than female with male: female ratio equal to ( 1.5:1) . The difference between peripheral and central PCV was (4 - 15%) with a mean and standard deviation of ( 7 ± 0.33%). The main signs & symptoms were jaundice (58%), lethargy (30%) , respiratory distress(26%) and hypoglycemia (26%) . Risk factors were preterm (36%) , neonates of diabetic mother(20%) , small for gestational age (18%) , twin pregnancy (12%) and down's syndrome (10%) . Partialexchange transfusion was done to 28 cases (56%). CONCLUSION: Males were affected more than females. Jaundice was the main presentation followed by lethargy,respiratory distress and hypoglycemia .Higher risk in twin pregnancy ,neonates of diabetic mother ,small for gestational age , preterm and down's syndrome while delivery by caesarian section reducethe risk of polycythemi


Article
A Novel Semi Automated On-Line Determination of Oxonium Ion Via Precipitation Reaction Using a New Mode of Attenuated Measurement of Incident Light (0 – 180o) by AYAH 5SX4-ST-5D Solar CFI Analyser.
تقدير نبيل اني شبه تلقائي لأيون الأوكسونيوم عن طريق تفاعل الترسيب بأستخدام نمط جديد لقياس توهين الضوء الساقط بزاوية (0-180˚) بوساطة AYAH 5SX4-ST-5D solar CFI analyser

Authors: Hussein F. A. AL-Razack حسين فارس عبد الرزاق الجبوري --- Issam M. A. Shakir عصام محمد علي شاكر الهاشمي
Journal: Iraqi Journal of Science المجلة العراقية للعلوم ISSN: 00672904/23121637 Year: 2014 Volume: 55 Issue: 4B Pages: 1736-1750
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Strong acids were determined via the precipitation reaction of loaded copper (II) ion on strong cation exchange resin which in turn reacts with potassium hyxacyano ferrate (II). The attenuation effect of formed precipitate Cu2 [Fe (CN) 6] on (0 -180o) incident LED light was measurement via homemade AYAH 5SX4-ST-5D solar CFI analyser. Optimum parameters were 0.005M.L-1 [Fe(CN)6]-4 , flow rate of 2.4 mL.min-1 , sample volume 204 µL , sample purge time of 64 seconds was chosen, and 1.6 V for light intensity. A liner calibration graph of 0.005 -0.2 M.L-1 were obtains for HCl, HNO3, HCLO4 and H2SO4, with a linearity (r2 %) 96 -97 % and L.O.D based on gradual dilution of lowest concentration in calibration graph was 37.19 µg for HCl, 64.273 µg for HNO3, 102.26 µg for HCLO4, and 0.01 µg for H2SO4 .Repeatability (RSD %) less than 1.12 was obtained. the proposed was compared well with standard method. FTU method for available acid in commercial ( HCl, H2SO4).

قدرت الحوامض القوية عن طريق تفاعل الترسيب والمعتمد على التفاعل بين ايون النحاس الثنائي والمحمل على مبادل ايوني حامضي قوي و بوناسيوم سداسي ثايوسيانات الحديد (II). قياس توهين الضوء المسلط بزاوية ( 0-180˚) والمعتمد على تكوين راسب Cu2 [Fe (CN) 6] يتم عن طريق محلل الحقن الجرياني المستمر والمصنع محليا AYAH 5SX4-ST-5D solar CFI analyser. تم اختيار الظروف الفضلى 0.005مول.لتر-1 [Fe(CN)6]-4 وسرعة الجريان 2.4 مل. دقيقة-1 ,حجم الأنموذج المحقن 204مايكروليتر ,زمن حقن الأنموذج 64 ثانية ويالأضافة الى 1.6 فولت وهي شدة الضوء الساقط . منحني معايرة بحدود 0.005 – 0.2 مول .لتر-1 لكل من HCl, HNO3, HClO4 بالأضاقة الى H2SO4مع نسبة خطيه (r2% ) تمتد من 96- 97 % بالأضافة الى حدود الكشف (LOD ) والمستندة على التخفيف التدريجي لأقل تركيز في منحني المعايرة 73.19ملغم لأنموذج HCl , 64.273مكغم لـ HNO3 , 102.26 مكغم لـ HClO4 بالأضافة الى 0.01 مكغم لـ H2SO4 . تم الحصول على تكرارية (RSD% ) اقل من 1.12 .وقد تم مقارنة الطريقة المقترحة مع الطريقة الكلاسيكية لكل من الحوامض المتوفرة (HCl , H2SO4).


Article
New mode for the on-line determination of oxonium ion in differentstrong acids using CFIA via the use of homemade linear array Ayah 5Sx4-ST- 5D solar CFI analyser
طريقة جديدة انيه لتقدير ايون الاوكسونيوم في الحوامض القويه المختلفة باستخدام تقنيه التحليل بالحقن الجرياني المستمر من خلال استخدام محلل الحقن الجرياني المستمرlinear array Ayah 5Sx4-ST- 5D solar

Authors: Issam M. A. Shakir عصام محمد علي شاكر --- Hussein F. A. AL-Razack حسين فارس عبد الرزاق
Journal: Iraqi Journal of Science المجلة العراقية للعلوم ISSN: 00672904/23121637 Year: 2015 Volume: 56 Issue: 1B Pages: 282-302
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Strong acids were determined via the blue complex solution reaction of a loaded ferric (III) ion on strong cation exchange resin which in turn reacts with potassium hyxacyano ferrate (II). The attenuation effect of formed blue complexFe4([Fe(CN)6])3on (0 -180o) incident LED light was measurement via homemade linear array AYAH 5SX4-ST-5D solar CFI analyser. Optimum parameters were 0.005M.L-1 [Fe(CN)6]-4 , flow rate of 3mL.min-1 , sample volume 204 µL , sample purge time of 70 seconds was chosen, and 1V for light intensity. A liner calibration graph of 0.005 -0.15 M.L-1 were obtains for HCl, HNO3, HCLO4 and H2SO4, with a linearity (r2 %) 94 -98 % and L.O.D based on gradual dilution of lowest concentration in calibration graph was 22.314 µg for HCl, 38.563 µg for HNO3,61.480 µg for HCLO4, and 60.020 µg for H2SO4 .Repeatability (RSD) 0.5% was obtained. the proposed method was compared with standard method. turbidity measured using HANNA instrument for available acid in commercial (HCl, H2SO4).

قدرت الحوامض القوية عن طريق محلول معقد ازرق والمعتمد على التفاعل بين ايون الحديد الثلاثي والمحمل على مبادل ايوني حامضي قوي وبوناسيوم سداسي ثايوسيانات الحديد (II). قياس توهين الضوء المسلط بزاوية ( 0-180˚) والمعتمد على تكوين معقد ازرق Fe4([Fe(CN)6])3 يتم عن طريق محلل الحقن الجرياني المستمر والمصنع محليا linear array AYAH 5SX4-ST-5D solar CFI analyser. تم اختيار الظروف الفضلى 0.005مول.لتر-1[Fe(CN)6]-4 وسرعة الجريان 3 مل. دقيقة-1 ,حجم الأنموذج المحقن 204مايكروليتر ,زمن حقن الأنموذج 70 ثانية ويالأضافة الى 1 فولت وهي شدة الضوء الساقط . منحني معايرة بحدود 0.005 – 0.15 مول .لتر-1 لكل من HCl, HNO3, HClO4 بالأضاقة الى H2SO4مع نسبة خطيه (r2% ) تمتد من 94- 98 % بالأضافة الى حدود الكشف (LOD ) والمستندة على التخفيف التدريجي لأقل تركيز في منحني المعايرة 22.314مكغم لأنموذج HCl , 56.38مكغم لـ HNO3, 48.61 مكغم لـ HClO4بالأضافة الى 02.60مكغم لـ H2SO4 . تم الحصول على تكرارية (RSD% ) 0.5% .تم مقارنة الطريقة المقترحة مع الطريقة الكلاسيكية(قياس التعكريه) باستخدام جهازHANNA لكل من الحوامض المتوفرة (HCl , H2SO4).


Article
Small Volume Therapeutic Plasma Exchange Using Crystalloid Replacement Fluid is the Choice in Patients with Concomitant Anemia

Authors: Zainab Mohammed Hasan --- Abbas Hashim Abdulsalam
Journal: Iraq Joural of Hematology المجلة العراقية لامراض الدم ISSN: 20728069/25432702 Year: 2011 Volume: 1 Issue: 1 Pages: 50-56
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

AbstractBackground: Therapeutic plasma exchange (TPE) is used to treat a variety of diseases, however, patient who needssuch therapeutic regime can be already anemic and TPE itself may worsen the state of anemia by imposingred cell hemolysis and dilution.Objectives: To evaluate the effect of small volume TPE, type of replacement fluid, frequency of sessions and totalvolume of plasma exchanged on the level of Hb concentration and PCV %.Patients & Methods: This is a prospective study in which 50 patients underwent TPE at National Center for BloodTransfusion. A course of 3-12 TPE sessions performed at 1-11 days intervals; in each session about 1 liter ofplasma was exchanged. Normal saline used as the replacement fluid for 25 patients and diluted FFP used forremainder.Results: Hb concentration and PCV % changed significantly after the first (P-value 0.003 and 0.03 respectively) andlast (P-value 0.001 for both) TPE sessions using crystalloid replacement fluid. Also Hb concentration andPCV % changed significantly after the first (P-value 0.006 and <0.001 respectively) and last (P-value <0.001for both) TPE sessions using diluted FFP fluid. The differences in Hb concentration and PCV % were notrelated to the type and total amount of replacement fluid, frequency and spacing between sessions. Alsothere was no relation between the frequency of complications and type of replacement fluid and amount ofplasma exchanged per session except for perioral numbness and bleeding from site of puncture in which itwas significant with p-value 0.01 and 0.001 respectively.Conclusions: Crystalloid solution can be used as the replacement fluid in small volume TPE especially in anemicpatients. The amount of PE per session is a limiting factor for the development of TPE-related bleeding.Increasing the frequency of TPE sessions and reducing time spacing between them to increase the totalamount of PE is safe. TPE-related citrate toxicity is reduced by using crystalloid replacement fluid.


Article
Glimpse on Hemostatic Changes Produced By Plasmapheresis

Authors: Haider H. AL-Shammari --- Mayada S. Al-Niami --- Zainab M. Hasan
Journal: Journal of the Faculty of Medicine مجلة كلية الطب ISSN: 00419419 Year: 2010 Volume: 52 Issue: 2 Pages: 161-168
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Background: Aphaeresis is a term that means to separate or to take away. The basic idea of aphaeresis is efficient removal of a circulating cellular blood component, either cells (Cytopheresis) or plasma solute (plasmapheresis, plasma exchange).Thus, the treatment goal of aphaeresis is to remove the circulating cell or substance directly responsible for the disease process. Acceleration and development of aphaeresis applications had taken place with the arrival of automated cell separators in 1970s that ensure selectively removal of one or more of blood components from the blood and return the remainder to the individual. Plasmapheresis is separation of plasma from blood cells which are returned to the body. It is accompanied by multiple changes in haemostatic system. As many coagulation factors are removed during procedure, changes in selective parameters: Prothrombin Time (PT), Partial Thromboplastin Time (PTT), Thrombin Time (TT), Fibrinogen (FNG) & platelets count are found when the replacement fluids devoid from coagulation factor are used.
Patients and Methods: This clinico-haematological study conducted during a period of six months, from February 2004 to July 2004 at the National Blood Transfusion Center (NBTC) in Baghdad & 50 patients underwent Therapeutic Plasma Exchange (TPE) for various disorders with the use of two types of automated blood cell separators (Haemonetics MCS + which represent an intermittent flow centrifugation technique – IFC & Fresenius AS. TEC 204 which represent the continuous flow centrifugation technique - CFC) in this study, but no instrument type influenced the coagulation screening tests.
Results: The changes in all selective parameter: Prothrombin Time (PT), Partial Thromboplastin Time (PTT), Thrombin Time (TT), Fibrinogen (FNG), Platelets count, Haemoglobin (Hb) and Packed Cell Volume (PCV) were significant after Therapeutic Plasma Exchange (TPE). There was no significant difference in changes in crystalloid group from that in Fresh Frozen Plasma group. In crystalloid group, significant correlation was observed between Prothrombin Time (PT), Activated Partial Thromboplastin Time (APTT), Thrombin Time (TT) & volume of Plasma Exchanged (PE) /session, while spacing between sessions and the number of sessions is significantly correlated with Thrombin Time (TT). Plasma fibrinogen concentration and platelets count were decreased in the patients included in our current study.
Conclusion: There is no significant difference in changes in haemostatic system whether crystalloid or diluted Fresh Frozen Plasma (FFP) was used as replacement fluid. Thus, crystalloid, solution devoid of coagulation material can be used as a replacement fluid in the Therapeutic Plasma Exchange (TPE) if the volume of Plasma Exchanged (PE) is small. These results are of vital importance from the practical & public health point of view in minimizing the usage of blood components((i.e. Fresh Frozen Plasma (FFP) which is a potential source of Transfusion Transmissible Infections (TTIs) worldwide)) & replaced by crystalloid solution as a safer replacement fluid substitute in Therapeutic Plasma Exchange (TPE) process.


Article
Removal of Zinc ions from industrial wastewater with wool fibers
ازالة ايونات الخارصين من مياه المجاري الصناعية بواسطة الياف الصوف

Authors: Ammar W. Ahmed عمار وعد الله احمد --- Salwa Shamran Jassim سلوى شمران جاسم --- Ayad H. Jassim اياد حمزة جاسم
Journal: Baghdad Science Journal مجلة بغداد للعلوم ISSN: 20788665 24117986 Year: 2010 Volume: 7 Issue: 3 Pages: 1193-1201
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

In this research, the efficiency of low-cost unmodified wool fibers were used to remove zinc ion from industrial wastewater. Removal of zinc ion was achieved at 99.52% by using simple wool column. The experiment was carried out under varying conditions of (2h) contact time, metal ion concentration (50mg/l), wool fibers quantity to treated water (70g/l), pH(7) & acid concentration (0.05M). The aim of this method is to use a high sensitive, available & cheep natural material which applied successfully for industrial wastewater& synthetic water, where zinc ion concentration was reduced from (14.6mg/l) to (0.07mg/l) & consequently the hazardous effect of contamination was minimized.

في هذا البحث، تمت الاستفادة من كفاءة الياف الصوف غير المحسنة واطئة الكلفة لازالة ايون الخارصين من مياه المجاري الصناعية. تم ازالة ايون الخارصين بنسبة 99.52% باستخدام عمود الصوف البسيط. تم تنفيذ التجربة عند ظروف مختلفة، حيث ان زمن الاستبقاء (2 ساعة) وتركيز ايون الخارصين (50 ملغم/لتر) وكمية الياف الصوف الى الماء المعامل (70 غم/لتر) والدالة الحامضية(7) وتركيز الحامض (0,05 مولاري). ان الهدف من التجربة هو استخدام مادة طبيعية رخيصة الثمن ومتوفرة بكثره و ذات حساسية عاليه للايونات والتي تم تطبيقها بنجاح على مياه المجاري الصناعية والمياه المصنعة، حيث تم تقليل تركيز ايون الخارصين في هذه المياه من (14.6 ملغم/لتر) الى (0.07 ملغم/لتر) وهكذا تم خفض مستوى التلوث.

Listing 1 - 10 of 184 << page
of 19
>>
Sort by
Narrow your search

Resource type

article (184)


Language

English (70)

Arabic and English (59)

Arabic (54)


Year
From To Submit

2019 (26)

2018 (31)

2017 (16)

2016 (15)

2015 (18)

More...