research centers


Search results: Found 78

Listing 1 - 10 of 78 << page
of 8
>>
Sort by

Article
The Effect of Specifications Flat Plate Collector on its Performance
تأثير خصائص اللوح الماص على اداءه

Author: Nables Younis Sulayman
Journal: Al-Rafidain University College For Sciences مجلة كلية الرافدين الجامعة للعلوم ISSN: 16816870 Year: 2006 Issue: 18 Pages: 200-210
Publisher: Rafidain University College كلية الرافدين الجامعة

Loading...
Loading...
Abstract

The present paper includes a theoretical study concerning the effect of specifications for absorber flat plate collector (collector plate temperature, outlet temperature, storage volume and the collector area) on its performance, also its effected on flow rate of fluid and the efficiency of flat plate collector. The present data have been compared with other studies.

تضمن البحث دراسة نظرية حول تأثير مواصفات اللوح الماص لمجمع شمسي (درجة حرارة اللوح الجامع ، درجة الحرارة النهائية ، حجم الخزان ، ومساحة اللوح) على اداءه ومدى التأثير على تدفق السائل وكفاءة السخان الشمسي. تمت مقارنة النتائج المستحصلة مع بحوث اخرى.


Article
CFD Simulation of Enhancement Techniques in Flat Plate Solar Water Collectors

Authors: Jafar Mehdi Hassan --- Qussai J. Abdul-Ghafour --- Mohammed F. Mohammed
Journal: AL-NAHRAIN JOURNAL FOR ENGINEERING SCIENCES مجلة النهرين للعلوم الهندسية ISSN: 25219154 / eISSN 25219162 Year: 2017 Volume: 20 Issue: 3 Pages: 751-761
Publisher: Al-Nahrain University جامعة النهرين

Loading...
Loading...
Abstract

The present work is a numerical study of thermal performance of modified flat plate solar water collectors. Numerical simulations have been done by solving the governing equations (Continuity, Momentum and Energy) equations in the laminar regime , three dimensions by using the FLUENT software version (14.5). The effect of flow on temperature distribution of flat plate water collectors by inserting (twist strip with twist ratio (3), helical spring surrounding the solid shaft) inside riser pipes is numerically simulated and compared with solar collector without inserting device inside its riser pipes at flow rates of (100)ℓ/h . The numerical simulation results show that the flat plate water, solar collectors with the inserted, twist strip and helical spring that’s surround the solid shaft were higher enhancement of heat transfer than without inserted devices. The useful energy in case of twist strip is (10%) higher than the case of flat plate solar collector without enhancement device. Also, the case of helical spring is increased (6.8 %) than the twist strip, and (16.2%) than collector without enhancement device for the same mass flow rate.

يوضح البحث الحالي دراسة عددية لتحسين الاداء الحراري لمجمعات الماء الشمسية المسطحة. تمت الدراسة العددية بحل المعادلات الحاكمة (الاستمرارية ، الزخم والطاقة) لجريان طباقي ثلاثي الابعاد باستخدام برنامج (Fluent 14.5 ) . تضمن الحل العددي دراسة تاثير الجريان وتوزيع درجات الحرارة لمجمعات الماء الشمسية من خلال اقحام ادوات (شريط ملتوي ذات نسبة التواء (3) ، محور صلب محاط بنابض حلزوني ) داخل انابيب رفع الماء ومقارنتها مع مجمع شمسي بدون اقحام ادوات داخل انابيب رفع الماء عند معدل تدفق (100) لتر/ ساعة. اظهرت النتائج العددية ان اقحام شريط ملتوي ذات نسبة الالتواء (3) ومحور صلب محاط بنابض حلزوني داخل انابيب رفع الماء تؤدي الى تحسين انتقال الحرارة بشكل ملحوض عن الحالة بدون اقحام هذه الادوات . ان الطاقة المفيدة في حالة الشريط الملتوي اعلى بمقدار ((10% في حالة المجمع الشمسي بدون ادوات اقحام . كذلك في حالة اقحام محور صلب محاط بنابض حلزوني بلغت الزيادة في مقدار الطاقة المفيدة 6.8 %)) عن حالة الشريط الملتوي و 16.2% )) عن حالة المجمع الشمسي بدون ادوات اقحام عند نفس معدل التدفق.


Article
PERFORMANCE STUDY OF OFDM BASED ON IP-WT
دراسة أداء مازج تقسيمات التردد المتعامدة بالاعتماد على في-مكان لتحويل الويفليت

Author: Salih M. Salih صالح محمد صالح
Journal: Journal of university of Anbar for Pure science مجلة جامعة الانبار للعلوم الصرفة ISSN: ISSN: 19918941 Year: 2008 Volume: 2 Issue: 1 Pages: 131-138
Publisher: University of Anbar جامعة الانبار

Loading...
Loading...
Abstract

In this paper, a proposed model based on In-Place Wavelet Transform (IP-WT) was suggested to improve the performance of the Orthogonal Frequency Division Multiplexing (OFDM) under the Additive White Gaussian Noise (AWGN), and flat fading channel. The proposed model does not require additional arrays at each sweep such as in the ordered Haar wavelet transform; this ensures fast processing time with minimum memory size. The results extracted by a computer simulation and compared with the performance of the conventional model based on Fast Fourier Transform (FFT). As a result, it can be seen that the proposed technique has high performance improvement over the conventional OFDM system based FFT, where the Bit Error Rate (BER) is widely reduced under these models of channels.

تحت تأثير قناة الضوضاء (OFDM) في هذا البحث تم اقتراح نموذج لتحسين أداء مازج تقسيمات التردد المتعامدةبالاعتماد على في- مكان لتحويل الويفليت وقناة الخبو المنبسط . ان النموذج (IP-WT) الابيض التراكمية لكاوزمرحلة معالجة للإشارة مثلما يحتاجه تحويل (AWGN) المقترح لايحتاج الى مصفوفة إضافية عند كل مستوى منحجم للذاكر ة .تم مقارنة النتائج مع اداء .(FFT) الويفليت المرتب؛ وبالتالي فان سرعة المعالجة ستزداد وبأقلالنموذج الاعتيادي المعتمد على تحويل الفوري السريع النتائج بينت ان النموذج المقترح قد اعطى تحسن عاليبالاداء نسبة الى النموذج الاعتيادي ، حيث انقل بشكل كبير تحت تأثير تلك النماذج من القنوات.

Keywords

In-Place --- QAM --- OFDM --- AWGN --- Flat Fading


Article
Effect Of Openiings With Or Without Strenghening On Punching Shear Strength For Reinforced Concrete Flat Plates
تأثير الفتحات مع أو بدون تقويه على مقاومة القص الثاقب لبلاطات خرسانية مستوية مسلحه

Author: Abeer H.H. Al-Shammari
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2011 Volume: 17 Issue: 2 Pages: 218-234
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Reinforced concrete slabs with openings are usually designed with help of traditional rules proposed by building codes. Such methods introduce limitations concerning size, location of openings and magnitude of applied loads. Furthermore, there are some traditional approaches to strengthen reinforced concrete slabs with openings which can be either cumbersome or expensive. This paper studies variable locations of an opening with respect to a central column in reinforced concrete flat plates, and presents a good approach to strengthen this opening by using steel plates. Nine reinforced concrete flat plates are cast with dimensions (length, width and thickness) equal to (850, 470 and 50) mm) using a single concrete mix with average compressive strength (fcu) equals 30 MPa. Each slab contains a square cross-section opening (side length =75 mm) and supported by a central square cross-section column (side length =75 mm). The variables of this study are: the type of opening (with or without strengthening) and the clear distance between the opening and the column which takes the values (0.0d, 2d, 4.5d and 7d), where d is the effective depth. The specimens are tested over a simply supported span at four edges. The test results show that, the ultimate load reaches the maximum value for slab without opening while this load reaches the minimum value for slab with a non-strengthening opening and lies in the pattern of the failure zone (where the clear distance between the column and the opening equals 4.5d). When a comparison is made between the test results ,it is concluded that ;strengthening the slab opening with steel plates causes increasing in the ultimate load by (19.44 ,19.51 ,35.13 and 13.46) % for the specimens (0.0d ,2d ,4.5d and 7d ) respectively.

السقوف الخرسانيه المسلحة والحاوية على فتحات تصمم عادة بمساعدة القواعد التقليدية المقترحة من قبل انظمة ( كودات) البناء .هذه الطرق تقدم حدود بخصوص حجم الفتحات , موقع الفتحات وقيم الأحمال المسلطة.كذلك فان هنالك بعض الطرق التقليدية لتقوية السقوف الخرسانيه المسلحة ذات الفتحات وهذه الطرق أما متعبه أو مكلفه.هذا البحث يدرس مواقع متغيره لفتحه بالنسبة لعمود محوري لبلاطات خرسانيه مسلحه مستوية ,و يقدم طريقه جيده لتقوية تلك الفتحة باستخدام صفائح حديديه. تتضمن الدراسة صب تسعه نماذج من البلاطات الخرسانيه المسلحة بأبعاد (الطول ,العرض والسمك) مساوية إلى (850 ,470 و 50 ) ملم , كل سقف يحتوي فتحه ذات مقطع مربع (طول الضلع =75 ملم) ,باستخدام خلطه خرسانيه واحده بمعدل مقاومه انضغاط مساوية إلى 30 ميكا باسكال ,البلاطة مسنده بواسطة عمود محوري ذو مقطع مربع (طول ضلعه = 75 ملم) . متغيرات هذه الدراسة هي :نوع ألفتحه ( مع أو بدون تقويه ) و المسافة الصافية بين العمود والفتحة والتي أخذت القيم التالية (0 ,2 , 4.5 و 7 ) من العمق الفعال .تم فحص النماذج على فضاء بسيط الإسناد من الجوانب الاربعه . نتائج الفحص بينت أن حمل الفشل وصل أعلى قيمه له في السقف الغير حاوي على فتحه ,و وصل أدنى قيمه له في السقف ذي الفتحة غير المقواة و واقعة على مسار حيز الفشل ( عندما تكون المسافة الصافية بين العمود و الفتحة تساوي 4.5 من العمق الفعال ). عندما عملت مقارنه بين نتائج الفحوصات ,فقد تم استنتاج أن تقوية فتحات السقوف بصفائح حديديه يسبب زيادة في حمل الفشل بنسب ( 19.44 ,19.51 ,35.13 و 13.46 ) % للنماذج (0.0 ,2 , 4.5 و 7 ) من العمق الفعال على التوالي .


Article
EXPERIMENTAL STUDY OF NATURAL CONVECTION HEAT TRANSFER COEFFICIENT FROM FLAT ASBESTOSE-CEMENT
دراسة عملية لأنتقال الحرارة بالحمل الحر من لوح اسبستي مستوي

Authors: كفاح حامد هلال --- عبد الامير داخل زيدان --- قيس يوسف محمود
Journal: AL-TAQANI مجلة التقني ISSN: 1818653X Year: 2011 Volume: 24 Issue: 8 Pages: A1-A16
Publisher: Foundation of technical education هيئة التعليم التقني

Loading...
Loading...
Abstract

Natural convection heat transfer from flat asbestose – cement sheet which used in roofing and building constructions was studied experimentally. With air as the working fluid , the effects of heat flux and inclination angle on the local and average heat transfer coefficients were examined . The asbestos cement (0.45 * 0.45m) which heated surface facing upwards , was subjected to constant heat flux at arrange (1111 , 607 , 252 , 87 W/m2) and the experimental study was done with a range of inclination angles (00 , 150 , 300 , 450 ) from vertical . Results show that the local heat transfer coefficient increase with increasing of heat level or increasing the angle of inclination , Radiation heat transfer take place at (55 – 93%) percent from heat flux which provided to asbestose – cement sheet and convection heat transfer at (45 – 4.59%) percent . The relation between local Nusselt number and local Rayliah number which obtained from experimental results is : Nux = 1.34 (Rax)0.179 1 * 108 < Rax < 3 * 108

يتضمن البحث الحالي دراسة عملية لانتقال الحرارة بالحمل الحر من لوح اسبستي مستوي يستخدم في البناء والتسقيف ، تم تصنيع جهاز مختبري لاجراء التجارب على لوح بأبعاد (0.45 * 0.45m) مصنوع من مادة الاسبست وجهه المسخن الى الاعلى وبمستويات فيض حراري (1111 , 607 , 252 , 87 W/m2) وزوايا ميل ( )عن العمود . استخدم الهواء كوسط ناقل للحرارة وايجاد معامل انتقال الحرارة بالحمل الحر الموضعي والمتوسط وتأثرهما بتغيير الفيض الحراري وزاوية الميل عملياً وبينت النتائج ازدياد معامل انتقال الحرارة بالحمل الموضعي بزيادة الفيض الحراري وزيادة زاوية الميل عن العمود .وان كمية الحرارة المنتقلة بالاشعاع كانت بنسبة عالية (55 - 93%) من الفيض الحراري المسخن للوح ، اما الحرارة المنتقلة بالحمل الحر تكون بنسبة (45 – 4.59%) من الفيض الحراري . تم الحصول على العلاقة التالية بين رقم نسلت الموضعي ورقم رالي الموضعي ولمدى 1 * 108 < Rax < 3 * 108 Nux = 1.34 (Rax)0.179


Article
FLEXURAL STRENGTH OF FLAT PLATE WITH OPENING UNDER COMBINED LINEAR AND UNIFORMLY DISTRIBUTED LOADS
مقاومة الثني في السقوف المستوية ذات الفتحات المعرضة للأحمال المنتظمة التوزيع والأحمال الخطية

Author: Adnan Sadiq Al-Kuaity عدنان صادق الكويتي
Journal: KUFA JOURNAL OF ENGINEERING مجلة الكوفة الهندسية ISSN: 25230018 Year: 2011 Volume: 3 Issue: 1 Pages: 19-36
Publisher: University of Kufa جامعة الكوفة

Loading...
Loading...
Abstract

This paper presents an analytical study to predict the flexural strength of reinforced concrete flat plate with opening of any size. The study includes both plastic and elastic analysis of flat plate with opening. The plastic analysis is based on yield line theory using modified collapse mechanism as found experimentally by others ,whereas, the elastic analysis is carried out by finite element technique using computer program. The slab is considered to be under linear load around the opening edge besides the design loads ( uniformly distributed load). Comparisons between theoretical results obtained from the proposed equations derived in this study and those obtained from test results published by others is shown. The ratio of ultimate design load of flat slab with opening to its resisting moment along yield line is inversely proportional to the ratio of opening size to span length. The proposed equation shows that the theoretical collapse load is drastically reduced as the opening size increases. The reduction in flexural strength reaches to about 70% when the opening size increased to about 25% of slab area. A good agreement is found between the theoretical flexural strength proposed here and those observed by test results. The average ratio of theoretical strength to the test result was about 0.82. On the other hand, finite element results of cracking loads and elastic deflections have shown good agreement with those obtained from test results. The average ratio between them was about 0.8.

يقدم هذا البحث دراسة تحليلية نظرية لاحتساب قابلية تحمل للبلاطات الخراسانية المسلحة ذات الفتحات المحمولة بالأعمدة فقط و التي تكون تحت تأثير الأحمال الخطية على حواف فتحاتها إضافة للأحمال التصميمية الموزعة على سطوحها. تم أجراء تحليل لدن وأخر مرن لهذه السقوف حيث استخدم برنامج حاسبة الكترونية لإيجاد السلوك المرن إثناء التحميل إلى مرحلة ما قبل التشقق. أستند التحليل اللدن في هذه الدراسة على نظرية الخط اللدن في البلاطات باعتماد آلية الانهيار التي لوحظت عمليا عند فحص هذا النوع من البلاطات من قبل باحثين آخرين. هذا وقد استخدم برنامج الحاسبة الكترونية الذي يعتمد علي طريقة الشرائح المحددة في التحليل المرن. لقد أجريت مقارنات بين نتائج التحليل النظري المقترح في هذه الدراسة والنتائج العملية التي نشرت من قبل باحثين آخرين . لقد بينت النتائج النظرية إن نسبة التحمل القصوى للسقوف إلى مقاومة الثني تتناسب عكسيا مع نسبة حجم الفتحات إلى فضاء البلاطة. إن المعادلة المقترحة في هذه الدراسة تبين بان مقاومة الانحناء للبلاطات المنتخبة في هذه الدراسة تتناقص بدرجة كبيرة كلما ازداد حجم الفتحة في السقف. لقد أظهرت هذه الدراسة توافقا جيدا بين النتائج النظرية والنتائج العملية المنشورة من قبل باحثين آخرين. لقد بين التحليل المرن بان حمل التشقق و الإزاحة المركزية الناتجة عن طريقة الشرائح المحددة تتوافق جيدا مع النتائج العملية التي نشرت من قبل باحثين آخرين.


Article
EXPERMENTAL STUDY OF PUNCHING SHEAR FOR REINFORCED CONCRETE FLAT PLATE SLABS WITH COUPLED COLUMNS
دراسة عملية للقص الثاقب للبلاطات الخرسانية المسلحة ذات اعمدة مزدوجة

Loading...
Loading...
Abstract

This study is conducted to investigate the punching shear of reinforced concrete flat plate slabs supported by coupled columns; sixteen specimens with average cube compressive strength (fcu) of (28 MPa) were tested.The slab specimens were made with (850x470x50mm) dimensions and concrete cover of (15 mm). The specimens were tested over a simply supported span (800 x 420mm) at four sides. The variables investigated in this study are the shape of column and the clear distance between columns of the slab specimen. The specimens are divided according to column shape into two groups, each group includes eight specimens.The first group (group A) has two square columns with cross sectional dimensions of (75x75mm) and height of (75mm) and column cross-sectional area equals to (5626mm). The clear distance between columns were varied from (2 mm) to (325 mm) (equals to 0.05d to 9.3d). While, the second group (group B) has two circular columns with (85mm) diameter and (75mm) height and column cross-sectional area equals to (5671)mm with variable clear distance between them from (2 mm) to (315 mm) (equals to 0.05d to 9d ).The test results showed that, the ultimate load reaches the maximum value when the distance between columns equal to (9.3d and 9d) for group (A) and (B) respectively; and decreases by (6.5 to 33.9%) and by (16.4 to 35.9%) of the maximum ultimate load when the clear distance between columns decreases by (7d to 0.05d) for group (A) and (B) respectively.The test results show that when the clear distance between columns is in the range of (0.05d to 7d) ,the failure zone is separated as one zone ;while when the clear distance between columns is equal to (9.3d and 9d ), the failure zone separates into two zones

اعدهذا البحث لدراسة القص الثاقب للبلاطات الخرسانية المسلحة ذات أعمدة مزدوجة ، تتضمن الدراسة صب ستة عشر نموذج من البلاطات (الصفائح) الخرسانية المسلحة باستخدام خلطة خرسانية واحدة بمعدل مقاومة انضغاط(fcu) مساوية إلى (28MPa) .ابعاد البلاطات متماثلة (الطول , العرض والسمك) والمساوية إلى (470,850 و 50ملم ) وبنفس الغطاء الخرساني والمساوي إلى (15ملم). تم فحص النماذج على فضاء بسيط الإسناد من جميع إضلاعه الأربعة وبإبعاد (420x800 ملم)، المتغيرات التي تم دراستها في هذا البحث هي شكل العمود والمسافة الصافية ما بين الأعمدة. تم تقسيم النماذج إلى مجموعتين (A) و (B) حسب شكل العمود وبواقع ثمان نماذج لكل مجموعة.أعمدة ألمجموعه ( A) لها مقطع عرضي مربع الشكل طول ضلعه (75 ملم ) ومساحة مقطعه تساوي(5625ملم2) وارتفاع العمود يساوي (75ملم ) والمسافة الصافية بين الأعمدة متغيرة من (2ملم ) إلى (325 ملم) أي ((0.05dإلى (9.3d), بينما أعمدة المجموعة (B) لها شكل دائري بقطر (85ملم(ومساحة مقطعه (5675ملم2) وارتفاع العمود يساوي (75ملم ) والمسافة الصافية بين الأعمدة متغيرة من (2ملم ) إلى (315 ملم) أي ((0.05dإلى (9d) .بينت نتائج الفحوصات أن حمل الفشل وصل إلى أعلى قيمة عندما أصبحت المسافة بين الأعمدة مساوية إلى ( 9.3dو 9d) للمجموعتين(AوB) على التوالي ، وتتناقص هذه القيمة بنسبة تتراوح بين (6.5-33%) و(16.4-35.9%) من أقصى حمل للفشل عندما تناقصت المسافة بين الأعمدة من (7d) إلى (0.05d).عندما تكون المسافة الصافية بين الاعمدة بحدود (0.05dالى 7d) بينت نتائج الفحوصات أن منطقة الفشل تنفصل عن البلاطة كجزء واحد، لكن عندما تكون المسافة الصافية ما بين الاعمدة بحدود ( 9.3dو 9d) للمجموعتين (A) و (B) على التوالي فأن منطقة الفشل تنفصل عن البلاطة كجزئين منفصلين

Keywords

Punching --- Shear --- Flexural --- flat plate --- coupled --- columns


Article
Finite Element Analysis of Deformation Behavior of Wire Cold Flat Rolling

Author: Abdul Kareem Flaih Hassan
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2011 Volume: 29 Issue: 11 Pages: 2102-2113
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

Flat rolling of wire is an industrial process used to manufacture electrical flat wire, medical catheters, springs and piston segments, among other products. This paper presents a 3D finite element analysis of wire flat rolling. The variations of rolling force due to roll speed changes, Effect of reduction in height on width of contact Area, andLateral spread of wire has been discussed. It is found that a negligible increase in flow stress and rolling force does occur due to increase in the strain rate at room temperature. Besides, the results showed that the behavior of rolling force variation versus roll speeddepends on the rolling reductions. A theoretical relationship has been developed to relate the reduction in height of wire to the width of contact area between the rolls and wire. This relationship depicts that the width of contact area is proportional to square root ofreduction in height of wire. Finally the finite element can give a reasonable estimation of the deformation behavior in wire flat rolling, since the theoretical predictions are reasonable agreement with the experimental measurements of other authors.


Article
The Influence of Food Availability on Burrowing Activities The Crab Sesarma boulengeri (Calman)

Author: Hamza A. Kadhem
Journal: Journal of Basrah Researches (Sciences) مجلة ابحاث البصرة ( العلميات) ISSN: 18172695 Year: 2007 Volume: 33 Issue: 1A Pages: 1-10
Publisher: Basrah University جامعة البصرة

Loading...
Loading...
Abstract

Sesarma boulengeri (Calman) crab populations were tested for food limitation in an intertidal flat in Shatt Al-Arab River. Food supply was artificially increased by adding thin - cut plants. This resulted in a relative increase in the crabs population density, recruitment and organic content. Crabs dig more burrows than they require for theis protection and their physiological needs; some time they may dig burrows in excess even when empty burrows are available in response to their food supply. The hypothesis was examined by comparing burrow and crab densities in an intertidal flat, then manipulating the burrow density and food availability in the laboratory. Furthermore, females were assumed to be more sensitive to the food availability than males and small crabs more sensitive than large crabs and the numbers of burrows were more than crabs. Smaller crabs of both sexes burrow faster and to lesser depths .New burrows despite the presence of unoccupied burrows and burrowing activity of smaller crabs of both sexes varied with food availability. The final results showed that the small crabs may be more sensitive to food availability and may be more capable of adjusting their burrowing activity to their food supply.

تناول البحث تاثير وفرة الغذاء على كثافة حفر السرطانات في مسطحات المد والجزر لضفاف شط العرب وقد اجريت الدراسة حقليا" ومختبريا" للحصول على نتائج اكثر دقة. بينت النتائج ان السرطانات تظهر حساسية تجاه نقص المتطلبات الغذائية وانها تقوم بالحفر بصورة اكثر واسرع عندما يقل الغذاء ، كما تقوم بحفر الحفر المتشعبة ونقل الرواسب بسرعة اكبر مما هي عليه في الظروف الاعتيادية. اظهرت النتائج بان الاناث اكثر حساسية من الذكور وان السرطانات اليافعة اكثر حساسية من السرطانات الكبيرة في هذا المجال. كما بينت النتائج بان كثافة الحفر تكون اكثر من كثافة السرطانات عندما يكون هنالك نقص في المتطلبات الغذائية.


Article
Front Window Heat Loss From Different Material of Flat Plate Collector
الفقدان الحراري من الجهة الأمامية لصفائح مختلفة للسخان الشمسي

Author: Luma Mohammad Ali لمى محمد علي
Journal: Tikrit Journal of Pure Science مجلة تكريت للعلوم الصرفة ISSN: 18131662 Year: 2012 Volume: 17 Issue: 4 Pages: 169-173
Publisher: Tikrit University جامعة تكريت

Loading...
Loading...
Abstract

The present paper includes a theoretical study concerning front window heat loss of a single glazing flat plate collector, for different emissivity (e) of material (black chrome , black paint copper and black paint aluminum) and ambient temperature (Ta). A computer program is devised to find a relationship between heat loss through the glass cover and collection plate temperature. Computed data are fitted to 4th order polynomial equation include a constant coefficients shown in table (1) for application convenience.

يتضمن البحث دراسة نظرية حول الفقدان الحراري لصفيحة السخان الشمسي مغطاة بطبقة زجاجية واحدة ولمواد مختلفة الإنبعاثية (المواد المطلية بالصبغة السوداء وهي الكروم،النحاس والألمنيوم) ودرجة حرارة المحيط. صمم برنامج على الآلة الحاسبة لإيجاد العلاقة بين الفقدان الحراري من خلال الغطاء الزجاجي ودرجة حرارة الصفيحة الجامعة. أدخلت القيم المستحصلة في معادلة متعددة الحدود من الدرجة الرابعة تتضمن ثوابت موضحة في جدول رقم (1) لاستخدامها في تطبيقات مناسبة.

Listing 1 - 10 of 78 << page
of 8
>>
Sort by
Narrow your search

Resource type

article (78)


Language

English (62)

Arabic (7)

Arabic and English (7)


Year
From To Submit

2019 (2)

2018 (10)

2017 (10)

2016 (6)

2015 (10)

More...