research centers


Search results: Found 11

Listing 1 - 10 of 11 << page
of 2
>>
Sort by

Article
A Study of Forward Osmosis Using Various Drawing Agents

Authors: Adil A. Al-Hemiri عادل احمد الحميري --- ِAdil O. Sharif --- Mustafa Hussein
Journal: Iraqi Journal of Chemical and Petroleum Engineering المجلة العراقية للهندسة الكيمياوية وهندسة النفط ISSN: 19974884/E26180707 Year: 2009 Volume: 10 Issue: 3 Pages: 51-56
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

This research was aimed to study the osmotic efficiency of the draw solutions and the factors affecting the performance of forward osmosis process. The draw solutions used were magnesium sulfate hydrate (MgSO4.7H2O), potassium chloride (KCl), calcium chloride (CaCl2), and ammonium bicarbonate (NH4HCO3). It was found that water flux increases with increasing draw solution concentration, and feed solution flow rate and decreases with increasing draw solution flow rate and feed solution concentration. And also found that the efficiency of the draw solutions is in the following order:CaCl2> KCl> NH4HCO3> MgSO4.7H2O


Article
Forward Osmosis Process for the Treatment of Wastewater from Textile Industries
عملية التناضح الامامية لمعالجة مخلفات المياه من الصناعات النسيجية

Authors: Hasan F. Makki حسن فرهود مكي --- Majid I. Abdul Wahab ماجد ابراهيم عبدالوهاب --- Rana Raheem Said رنا رحيم سيد
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2013 Volume: 19 Issue: 12 Pages: 1557-1565
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

This paper was aimed to study the efficiency of forward osmosis (FO) process as a new application for the treatment of wastewater from textile effluent and the factors affecting the performance of forward osmosis process.The draw solutions used were magnesium chloride (MgCl2), and aluminum sulphate (Al2 ( SO4)3 .18 H2O), and the feed solutions used were reactive red, and disperse blue dyes. Experimental work were includes operating the forward osmosis process using thin film composite (TFC) membrane as flat sheet for different draw solutions and feed solutions. The operating parameters studied were : draw solutions concentration (10 – 90 g/l), feed solutions concentration (5 – 30 mg/l), draw solutions flow rate (10 – 50 l/hr), feed solutions flow rate (20-60 l/hr), constant pressure and temperature were maintained at 0.5 bar and 30ºC respectively. And includes operating the forward osmosis process using cellulose triacetate (CTA) membrane as flat sheet for different draw solutions and feed solutions. The operating parameters studied were : draw solutions concentration (10 – 90 g/l), and feed solutions concentration (5 – 30 mg/l), constant temperature at 30ºC. It was found that water flux increases with increasing draw solution concentration, and feed solution flow rate and decreases with increasing draw solution flow rate and feed solution concentration for TFC and CTA. It was found MgCl2 given water flux larger than Alum. And also found that reactive red given water flux larger than disperse blue.The experiments also show that CTA membrane gives higher water flux than TFC membrane for forward osmosis operation. The increase in water flux for CTA is about 12.85% than TFC.

يهدف هذا البحث الى دراسة كفاءة عملية التناضح الامامي كتطبيق جديد لمعالجة الفضلات الخارجة من الصناعات النسيجية والعوامل التي تؤثر على اداء عملية التناضح الامامي . محاليل السحب المستخدمة هي : كلوريد المغنيسيوم و كبريتات الالمنيوم المائية و محاليل اللقيم المستعملة هي : الاحمر المتفاعل و الازرق المنتشر . العمل التجريبي يتضمن تشغيل عملية التناضح الامامي باستخدام اغشية ( TFC ) على شكل صفيحة مستوية لمحاليل سحب مختلفة و محاليل لقيم مختلفة. العوامل التشغيلية التي تم دراستها : تركيز محاليل السحب (10-90غرام / لتر ), تركيز محاليل اللقيم (5-30ملغم / لتر) , معدل الجريان الحجمي لمحاليل السحب ( 10-50لتر / ساعة ) , معدل الجريان الحجمي لمحاليل اللقيم ( 20-60لتر / ساعة). الضغط و درجة الحرارة ثابتين عند0.5 بار و30 o م على التوالي . وكذلك يتضمن تشغيل الوحدة التناضحية بأستخدام اغشية من نوع CTA على شكل صفيحة مستوية . العوامل التشغيلية التي تم دراستها : تركيز محاليل السحب ( 10-90 غرام / لتر ) , و تركيز محاليل اللقيم ( 5-30ملغم / لتر )عند درجة حرارة ثابتة30o م. لقد وجد بأن معدل تدفق الماء يزداد بزيادة تركيز محلول السحب و معدل الجريان الحجمي لمحلول اللقيم ويقل بزيادة معدل الجريان الحجمي لمحلول السحب و تركيز محلول اللقيم لكلا الغشائين TFC)) وCTA)) .لقد وجد بان كلوريد المغنيسيوم يعطي معدل تدفق ماء اعلى من كبريتات الالمنيوم المائية . وايضا وجد بان الاحمر المتفاعل يعطي معدل تدفق ماء اعلى من الازرق المنتشر. اظهرت التجارب ايضا ان اغشية CTA تعطي معدل تدفق ماء اعلى من اغشية TFC في عمليات التناضح الامامي. ان الزيادة في معدل تدفق ماء لاغشية CTA تقريبا 12,85% من اغشية TFC.


Article
A Study of Water Flux through Forward Osmosis Membrane Using BrineFresh Water System

Authors: Adel A. Al-Hemiri عادل احمد عوض --- Marwah M. Kamil مروة مازن
Journal: Iraqi Journal of Chemical and Petroleum Engineering المجلة العراقية للهندسة الكيمياوية وهندسة النفط ISSN: 19974884/E26180707 Year: 2013 Volume: 14 Issue: 4 Pages: 11-18
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The present work aims to improve the flux of forward osmosis with the use of Thin Film Composite membrane by reducing the effect of polarization on draw solution (brine solution) side.This study was conducted in two parts. The first is under the effect of polarization in which the flux and the water permeability coefficient (A) were calculated. In the second part of the study the experiments were repeated using a circulating pump at various speeds to make turbulence and reduce the effect of polarization on the brine solution side.A model capable of predicting water permeability coefficient has been derived, and this is given by the following equations:z = Z_0 + (C.R.T)/(9.8 ( d^2/D^(2 ) +1) ) [Exp. [- 9.8 ( d^2/D^(2 ) +1 ) (A.M )/ρ . t] -1]


Article
REMOVAL OF LEAD, COPPER AND NICKEL IONS FROM WASTEWATER BY FORWARD OSMOSIS PROCESS
ازالة ايونات الرصاص، النحاس، والنيكل من المياه الملوثة بعملية التناضح الأمامي

Authors: Ahmed A. Mohammed --- Ahmed Faiq Al – Alawy --- Tamara Kawther Hussein
Journal: DIYALA JOURNAL OF ENGINEERING SCIENCES مجلة ديالى للعلوم الهندسية ISSN: 19998716/26166909 Year: 2015 Volume: 8 Issue: 4 Pages: 893-908
Publisher: Diyala University جامعة ديالى

Loading...
Loading...
Abstract

In this study the application of a novel forward osmosis (FO) process for the removal of Pb(II), Cu(II), and Ni(II) metal ions from wastewater is briefly described. Polyamide (thin film composite (TFC))used as flat sheet forward membrane for heavy metal rejection under orientation membrane of active layer facing feed solution and using NaCl of different concentration as the draw solution. The operating parameters studied were draw solutions concentration (5 - 100 g/l), feed solutions concentration (5 - 200 mg/l), pH of feed solution (4 - 8), constant pressure and temperature were maintained at 0.2 bar and 25 °C respectively. It was found that the water flux increases with increasing draw solution concentration, and decreases with increasing feed solution concentration and pH of feed solution. For different type of heavy metal used as feed solution, the order of water flux was Pb+2> Cu+2> Ni+2. For binary and ternary feed solution, the water flux decreased with time and increasing with the concentration of feed solution due to decreasing of driving force. Forward osmosis can be used to recover water from wastewater contaminated by heavy metals with a rejection efficiency more than 99%, 97% and 87% for Pb+2, Ni+2, and Cu+2metal ions respectively.

في هذة الدراسة تم تطبيق عملية التناضح الأمامي(FO) لازالة ايونات المعادن(الرصاص , النحاس, والنيكل) من المياه الملوثة.غشاء البولي امايد (البوليمر مركب رقيق الغشاء((TFC)استعمل على شكل صفيحة مستوية لرفض المعادن الثقيلة عندما يقابل محلول التغذية اللقيم الجهة الفعالة للغشاء الناضح واستعمال تراكيز مختلفة من محلول كلوريد الصوديوم كمحلول سحب .العوامل التشغيلية التي تم دراستها كانت : تركيز محاليل السحب (5-100غرام / لتر ), تركيز محاليل اللقيم (5-200 ملي غرام / لتر ) , درجة حامضية محلول اللقيم (4 – 8), الضغط و درجة الحرارة ثابتين عند 0.2 بار و25 مo على التوالي. لقد وجد بأن معدل تدفق الماء يزداد بزيادة تركيز محلول السحب ويقل بزيادة تركيز محلول اللقيم و زيادة درجة حامضية محلول اللقيم. لعدة أنواع من المعادن الثقيلة المستخدمة كمحاليل اللقيم كان ترتيب معدل الانتقال هو Pb+2> Cu+2> Ni+2. لمحلول اللقيم الثنائي والثلاثي كان معدل انتقال الماء يقل مع الزمن وزيادة تركيز محلول اللقيم نتيجة إلى نقصان القوة الدافعة للانتقال. التناضح الأمامي(FO) يستخدم لاسترجاع المياه من مياه الصرف الصحي الملوثة بالمعادن الثقيلة مع كفاءة رفض اكبر من 99%, 97% , و87% للـرصاص , النحاس, والنيكل على التوالي.


Article
Forward and Reverse Osmosis Process for Recovery and Re-use of Water from Polluted Water by Phenol
عملية التناضح الامامي والعكسي لاسترجاع واعادة استخدام الماء من المياه الملوثة بالفينول

Author: Ahmed Faiq Al-Alawy
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2011 Volume: 17 Issue: 4 Pages: 912-928
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The research aims to apply the novel forward osmosis (FO) process to recover pure water from contaminated water. Phenol was used as organic substance in the feed solution, while sodium chloride salt was used as draw solution. Membranes used in the FO process is the cellulose triacetate (CTA) and polyamide (thin film composite (TFC)) membrane. Reverse osmosis process was used to treatment the draw solution, the exterior from the forward osmosis process. In the FO process the active layer of the membrane faces the feed solution and the porous support layer faces the draw solution and this will show the effect of dilutive internal concentration polarization and concentrative external concentration polarization.In the FO process was a run-time for five hours, and the concentration of phenol 100 and 1000 mg/l, and for the NaCl the concentration was 10000 and 30000 mg/l. It was found that recovery percent increases with increasing time, while water flux through membrane decreases with increasing time. Also, it was found that recovery and water flux increases with increasing draw solution concentration, on the contrary, water flux and the percentage of recovery decreases with increasing the concentration of phenol (feed solution). Increase in draw solute (NaCl) concentration has more effect on the water flux in FO process compared with increase in the concentration of phenol. Outlet phenol concentration increases with time, while the outlet salt concentration decreases with increasing the time. The results showed that the cellulose triacetate membrane gave the highest recovery ratio from the thin film composite membrane. The highest recovery was reached in five hours is 51.33%, while using CTA membrane recovery rate increase, by 23% compared with TFC membrane. The value of the resistance to solute diffusion within the membrane porous support layer is 36.83 h/m. Reverse osmosis is perfect method for removal of dissolved salts from water, thus its suitable process for reducing the content of NaCl in draw solution; therefore the sodium chloride rejection percentage was 91.6 – 96 % for polyamide membrane (TFC). Within two hours of work of the reverse osmosis system the recovery percentage of pure water is 58%.

يهدف البحث الى تطبيق عملية التناضح الامامي(FO) الجديدة لاسترجاع الماء النقي من المياه الملوثة. تم استخدام الفينول كمادة عضوية في محلول التغذية, بينما تم استخدام ملح كلوريد الصوديوم كمحلول سحب. الاغشية المستخدمة في عملية التناضح الامامي هي غشاء الأسيتات الثلاثي السليلوزي (CTA) وغشاء البولي امايد (البوليمر الرقيق المركب (TFC)). تم استخدام عملية التناضح العكسي لمعالجة محلول السحب الخارج من عملية التناضح العكسي. في عملية التناضح الامامي الطبقة الفعالة للغشاء تقابل محلول التغذية وطبقة الدعم المسامية تقابل محلول السحب وهذا سوف يظهر تاثير استقطاب التركيز الداخلي المخفف واستقطاب التركيز الخارجي المركز. في عملية التناضح الامامي كان وقت التشغيل لمدة خمس ساعات ، وتركيز الفينول المستخدم 100 و 1000 مغ لتر ، وبالنسبة لتركيز NaCl كان 10000 و 30000 ملغم لتر. لقد وجد بأن نسبة الاسترجاع تزداد بزيادة الزمن ، في حين تدفق الماء خلال الغشاء يتناقص مع زيادة الوقت. وكذلك, لقد وجد بان الاسترجاع وتدفق الماء يزداد بزيادة تركيز محلول السحب, وبالعكس, تدفق الماء ونسبة الاسترجاع تقل بزيادة تركيز الفينول (محلول التغذية). الزيادة في تركيز مذاب السحب (NaCl) له تأثير اكثر على معدل تدفق الماء في عملية التناضح الامامي مقارنةً بالزيادة في تركيز الفينول. تركيز الفينول الخارج يزداد مع الزمن, بينما تركيز الملح الخارج يقل بزيادة الزمن. وأظهرت النتائج أن غشاء الأسيتات الثلاثي السليلوزي أعطى أعلى نسبة استرجاع من الغشاء الرقيق المركب. اعلى نسبة مئوية للاسترجاع تم التوصل اليها في خمس ساعات هي 51,33% ,بينما استخدام غشاء CTA الاسترجاع زاد بنسبة 23% مقارنةً باستخدام غشاء TFC. قيمة المقاومة لانتشار المذاب داخل الطبقة الداعمة المسامية للغشاء هي 36،83 ساعة م. التناضح العكسي هي طريقة مثالية لأزالة الاملاح الذائبة من الماء, لهذا تعتبر عملية مناسبة لتقليل محتوى ملح كلوريد الصوديوم في محلول السحب, ولهذا النسبة المئوية لرفض كلوريد الصوديوم كانت 91,6 – 96 % لغشاء البوليمر (TFC). خلال ساعتين من عمل نظام التناضح العكسي نسبة استرجاع الماء النقي هي 58 ٪.


Article
Concentration of Orange Juice Using Forward Osmosis Membrane Process

Author: Khalid W. Hameed خالد وليد حميد
Journal: Iraqi Journal of Chemical and Petroleum Engineering المجلة العراقية للهندسة الكيمياوية وهندسة النفط ISSN: 19974884/E26180707 Year: 2013 Volume: 14 Issue: 4 Pages: 71-79
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Forward osmosis (FO) process was applied to concentrate the orange juice. FO relies on the driving force generating from osmotic pressure difference that result from concentration difference between the draw solution (DS) and orange juice as feed solution (FS). This driving force makes the water to transport from orange juice across a semi-permeable membrane to the DS without any energy applied. Thermal and pressure-driven dewatering methods are widely used, but they are prohibitively energy intensive and hence, expensive. Effects of various operating conditions on flux have been investigated. Four types of salts were used in the DS, (NaCl, CaCl2, KCl, and MgSO4) as osmotic agent and the experiments were performed at the concentration of the salts in the DS ranged (3.5 – 20% by wt), the temperature of DS ranged (20 – 50oC), and the flow rate of the FS and DS ranged (1 – 4 lit/min). It was observed that the optimum operating conditions are: concentration of salt = 20% by wt for CaCl2, temperature of DS = 50oC, and the flow rate of FS = 4 lit/min where at these conditions the maximum flux was obtained equal to 13.2 lit/m2.h or the total volume of the water transferred from the juice (during 3 hours and membrane area of 0.0135 m2) was 0.535 lit. NaCl performed much higher efficiency as osmotic agent than the others salts up to the concentration of 15.2%, but after 15.2% the CaCl2 was the best.


Article
Osmotic Membrane Bioreactor for Oily Wastewater Treatment using External & Internal Configurations

Loading...
Loading...
Abstract

The present work aims to study the treatment of oily wastewater by means of forward osmosis membrane bioreactor process. Side stream (external) configuration and submerged (internal) configuration of osmotic membrane bioreactor were performed and investigated. The experimental work for each configuration was carried out continuously over 21 days. The flux behavior of forward osmosis membrane in an osmotic membrane bioreactor (OMBR) was investigated, using NaCl as the draw solution and CTA as FO membrane. The effect of mixed liquor suspended solids (MLSS) concentration and TDS accumulation of bioreactor on water flux and membrane fouling behaviors was detected. The accumulation and rejection of nutrients in the bioreactor (Nitrate, COD, and Phosphate) were investigated over the days of the experiment. Water flux and membrane fouling were not significantly affected by MLSS concentration at low level and this effect increase with increasing MLSS concentration (4000–10000 mg/L). Besides, water flux was severely affected by elevated salinity of the aeration tank. OMBR showed high removal of COD (96%) and FO membrane revealed high retention of phosphate (97%) but retention for nitrate was relatively low (72%). The sparingly soluble salts in the influent, bioreactor, draw solution, and RO effluent were detected through the experiment. The results showed flux decline with time to about 47% from the initial flux and two osmotic backwashing were applied at day 7 and 14 during the operation and the flux restored approximately 30% of its loss. Side stream and submerged configurations revealed nearly similar response over the experiments while side stream module showed better water flux (7.0 LMH) than submerged (6.1 LMH). The results showed that the concentration of inorganic ions is below the limits that may cause severe scaling.


Article
Comparative Study for Organic and Inorganic Draw Solutions in Forward Osmosis
دراسة مقارنة لمحاليل السحب العضوية واللاعضوية في عملية التنافذ الامامي

Authors: Hadeer Kadhim Mohammed هدير كاظم محمد --- Talib Rashid Abbas طالب رشيد عباس --- Ahmed Faiq Al-Alalawy أحمد فائق العلوي
Journal: Al-Khwarizmi Engineering Journal مجلة الخوارزمي الهندسية ISSN: 18181171 23120789 Year: 2017 Volume: 13 Issue: 1 Pages: 94-102
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The present work aims to study forward osmosis process using different kinds of draw solutions and membranes. Three types of draw solutions (sodium chloride, sodium formate, and sodium acetate) were used in forward osmosis process to evaluate their effectiveness with respect to water flux and reverse salt flux. Experiments conducted in a laboratory-scale forward osmosis (FO) unit in cross flow flat sheet membrane cell. Three types of membranes (Thin film composite (TFC), Cellulose acetate (CA), and Cellulose triacetate (CTA)) were used to determine the water flux under osmotic pressure as a driving force. The effect of temperature, draw solution concentration, feed and draw solution flow rate, and membrane types, were studied with respect to water flux. The results showed an increase in water flux with increasing feed temperature and draw solution concentrations In addition, the flux increased with increasing feed flow rate while the flux was inversely proportional with the draw solution flow rate. The results showed that reverse osmosis membranes (TFC and CA) are not suitable for using in FO process due to the relatively obtained low water flux when compared with the flux obtained by forward osmosis membrane (CTA). NaCl draw solution gave higher water flux than other draw solutions and at the same time, revealed higher reverse salt flux.

يهدف البحث الى دراسة عملية التنافذ الامامي بأستخدام انواع مختلفة من محاليل السحب والاغشية. ثلاثة انواع من محاليل السحب ( كلوريد الصوديوم, فورميت الصوديوم, وخلات الصوديوم ) استخدمت في عملية التنافذ الامامي وذلك لتقويم كفاءة هذه المحاليل عن طريق حساب معدل تدفق الماء ومعدل التدفق العكسي للاملاح. التجارب اجريت في وحدة مختبرية للتنافذ الامامي بأستخدام خلية ذات جريان متقابل وغشاء طبقي مسطح. استخدمت ثلاثة انواع من الاغشية هي الغشاء الرقيق المركب (TFC), سليلوز اسيتيت (CA) وسليلوز تراي اسيتيت (CTA) لحساب معدل تدفق الماء ومن خلال الضغط الاوزموزي بوصفه قوة دافعة و تأثير درجة الحرارة و تركيز محلول السحب و معدل جريان اللقيم ومحلول السحب, ونوع الغشاء تم دراستها من خلال حساب معدل تدفق الماء. اوضحت النتائج زيادة في معدل تدفق الماء مع زيادة درجة حرارة اللقيم وكذلك التاثير نفسه يحدث بزيادة تركيز محلول السحب, بالإضافة الى ذلك فأن معدل التدفق يزداد مع زيادة معدل جريان اللقيم بينما يكون التأثير عكسياً مع زيادة معدل جريان محلول السحب. النتائج اظهرت بأن أغشية التناضح العكسي TFC,CA)) ليس مناسبا لأستخدامه في عملية التنافذ الامامي وذلك لأنها تعطي معدل تدفق ضعيفا للماء بالمقارنة مع معدل التدفق الناتج عن غشاء CTA . محلول السحب كلوريد الصوديوم اعطى معدل تدفق اعلى للماء من محاليل السحب الاخرى المستخدمة في البحث وفي الوقت نفسه اظهرت الدراسة معدل تدفق عكسيا اعلى للاملاح بالنسبة لكلوريد الصوديوم.


Article
Comparative Study for Removal of Zn+2 Ions from Aqueous Solutions by Adsorption and Forward Osmosis

Author: Tamara Kawther Hussein
Journal: Iraqi Journal of Chemical and Petroleum Engineering المجلة العراقية للهندسة الكيمياوية وهندسة النفط ISSN: 19974884/E26180707 Year: 2017 Volume: 18 Issue: 2 Pages: 125-138
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The aim of this paper was to investigate the removal efficiencies of Zn+2 ions from wastewater by adsorption (using tobacco leaves) and forward osmosis (using cellulose triacetate (CTA) membrane). Various experimental parameters were investigated in adsorption experiment such as: effect of pH (3 - 7), contact time (0 - 220) min, solute concentration (10 - 100) mg/l, and adsorbent dose (0.2 - 5)g. Whereas for forward osmosis the operating parameters studied were: draw solution concentration (10 - 150) g/l, pH of feed solution (4 - 7), feed solution concentration (10 - 100) mg/l. The result showed that the removal efficiency by using adsorption was 70% and the removal efficiency by using forward osmosis was 96.2 %.


Article
Reduction of Concentrating Poisonous Metallic Radicals from Industrial Wastewater by Forward and Reverse Osmosis
اختزال تركيز جذور المعادن السامة من مخلفات المياه الصناعية بواسطة التنافذ الأمامي والتنافذ العكسي

Authors: G. A. R. Rassoul غياث عبد الرضا رسول --- Ahmed Faiq Al – Alawy احمد فائق --- Woodyian Nahedth Khudair وديان ناهض خضير
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2012 Volume: 18 Issue: 7 Pages: 784-798
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The research aims to use a new technology for industrial water concentrating that contains poisonous metals and recovery quantities from pure water.Therefore, the technology investigated is the forward osmosis process (FO). It is a new process that use membranes available commercial and this process distinguishes by its low cost compared to other process. Sodium chloride (NaCl) was used as draw solution to extract water from poisonous metals solution. The driving force in the FO process is provided by a different in osmotic pressure (concentration) across the membrane between the draw and poisonous metals solution sides. Experimental work was divided into three parts. The first part includes operating the forward osmosis process using TFC membrane as flat sheet for NaCl. The operating parameters studied were: draw solutions concentration (10 – 95 g/l), draw solution flow rate (12-36 I/h), temperature of draw solution (30 and 40°C), feed solution concentration (10 -210 mg/l), feed solution flow rate (10 -50 l/h), temperature of feed solution (30 and 40°C) and Pressure (0.4 bar). The second part includes operating the forward osmosis process using CTA membrane as flat sheet for NaCl. The operating parameters studied were: draw solution concentration (15 – 95 g/l), feed solution concentration (10-210 mg/l). Constant temperature was maintained at 30°C. The last part includes operating the reverse osmosis process using TFC membrane as spiral wound module in order to separate NaCl salt from draw solution and obtain on pure water so as to usefully in different uses and also obtain on solution of NaCl concentrate which was recirculated to forward osmosis process. It is then used as draw solution. The operating parameter studied was: feed solution flow rate (15-55 l/h).The experimental results show that the water flux increases with increasing draw solution concentration, feed solution flow rate, temperature of draw solution and decreases with increasing feed solution concentration, draw solution flow rate and temperature of feed solution. The experiments also show that CTA membrane gives higher water flux than TFC membrane for forward osmosis operation.

يهدف البحث لاستخدام تكنولوجيا جديدة لتركيز المياه الصناعية الحاوية على المعادن السامة واسترجاع كميات من المياه النقية . لذلك تمت دراسة عملية التنافذ الأمامي وهي طريقة جديدة تستخدم الأغشية المتوفرة تجارياً وتمتاز هذه العملية بكلفتها القليلة مقارنة بالطرق الأخرى . تم استخدام كلوريد الصوديوم (NaCl) كمحلول سحب لنزع الماء النقي من محاليل المعادن السامة . القوة الدافعة في عملية التنافذ الأمامي ناتجة من فرق الضغط التنافذي (التركيز) على جانبي الغشاء بين محلول السحب ومحلول المعادن السامة . تم تقسيم الجزء العملي إلى ثلاث أقسام : يضم القسم الأول تشغيل عملية التنافذ الأمامي باستخدام غشاء TFC على شكل صفيحة مستوية لمحلول سحب كلوريد الصوديوم. الظروف التشغيلية التي تم دراستها : تركيز محلول السحب (15-95 g/l) ، معدل الجريان لمحلول السحب (12-36 l/h) ، درجـة حرارة محلـول السحب (30 , 40°C) ، تركيز محلول اللقيم (10-210 mg/l) ، معدل الجريان لمحلول اللقيم (10-50 l/h)، ودرجة حرارة محلول اللقيم (30 , 40 °C) . الضغط (0.4 bar). القسم الثاني يضم تشغيل منظومة التنافذ الأمامي باستخدام غشاء نوع CTA على شكل صفيحة مستوية لمحلول السحب كلوريد الصوديوم . وكان تركيز محلول السحب (15-95 g/l) ، وتركيز محلول اللقيم ( 10-210 mg/ l) . درجة الحرارة ثابتة عند 30°C . القسم الثالث تضمن تشغيل منظومة التنافذ العكسي باستخدام غشاء نوع TFC على شكل وحدة حلزونية لفصل ملح الـNaCl من محلول السحب والحصول على مياه نقية يمكن الاستفادة منه في العديد من الاستخدامات وكذلك الحصول على محلول NaCl مركز يتم استرجاعه إلى منظومة التنافذ الأمامي واستخدامه من جديد كمحلول سحب . وكان الظرف التشغيلي الذي تم دراسته : معدل الجريان لمحلول اللقيم (15-55l/h). أظهرت نتائج البحث ان معدل تدفق الماء يزداد بزيادة تركيز محلول السحب ومعدل الجريان لمحلول اللقيم ودرجة حرارة محلول السحب والقوة الدافعة ويقل بزيادة تركيز محلول اللقيم ومعدل الجريان لمحلول السحب وزيادة درجة حرارة محلول اللقيم وكذلك أظهرت النتائج ان أغشية CTA تعطي معدل تدفق ماء أعلى من أغشية TFC في عمليات التنافذ الأمامي .

Listing 1 - 10 of 11 << page
of 2
>>
Sort by
Narrow your search

Resource type

article (11)


Language

English (9)

Arabic and English (2)


Year
From To Submit

2017 (2)

2016 (1)

2015 (1)

2013 (4)

2012 (1)

More...