research centers


Search results: Found 5

Listing 1 - 5 of 5
Sort by

Article
COMPARISON OF COOLING LOAD CALCULATION METHODS BY

Author: Khalid A. Joudi
Journal: Al-Fatih journal مجلة الفتح ISSN: 87521996 Year: 2005 Volume: 1 Issue: 24 Pages: 57-61
Publisher: Diyala University جامعة ديالى

Loading...
Loading...
Abstract

The present work includes cooling load measurement in Iraq. One room located in Baqubah was the object of the study. The measurement was taken for the room in summer months of 2004 (i.e. in May, June, July, August & September). The area of test room was 15 m2 and 3 m ceiling height with medium weight construction specifications. The test room includes exterior east and west wall facing, un-conditioning adjacent space with an exterior roof, east window and an exterior west door. The air conditioner unit used in this work was a window type with a nominal capacity of 2 T.R. (7 kW). The theoretical cooling load was predicted by three methods of cooling load calculation, which are TFM, CLTD/SCL/CLF & TETD/TA methods. Measurement of cooling load showed that there is a large difference between the measured and predicted cooling load with all theoretical methods. The difference ranged from 33% to 40%. This large difference is appear because of the several season such as the air conditioner type, suffer environmental and the construction specification of the test room where it’s represent the Iraqi building and not exactly same as building specification tabulated in ASHRAE tables ,يعنى هذا البحث بإجراء قياسات عملية لحساب حمل التبريد في العراق. غرفة الاختبار الواقعة في مدينة بعقوبة كانت مشروع الدراسة حيث أخذت القياسات خلال اشهر الصيف (أيار, حزيران, تموز, آب و أيلول). و كانت مساحة غرفة الاختبار 15م2 مع ارتفاع 3م للسقف مع مواصفات إنشاء ذات تركيب متوسط. تشمل غرفة الاختبار جداران خارجيان أحدهما مواجه للشرق و الآخر مواجه للغرب مع حيز مجاور غير مكيف مع سقف خارجي و كذلك شباك مواجه للشرق و باب خارجية مواجه للغرب. و قد كانت منظومة التكييف التي لتبريد هذه الغرفة تم استخدام وحدة تبريد جدارية سعة 2طن تثليج (7كيلو واط). أجريت الحسابات النظرية لحمل التبريد بثلاث طرق لحساب حمل التبريد و هي طريقة دالات التحويلTFM وطريقة حمل التبريد من فرق درجات الحرارة (CLTD) بالإضافة إلى طريقة فرق درجات الحرارة الكلي المكافئ (TETD). أظهرت النتائج العملية لحسابات حمل التبريد للغرفة أن هناك فرق في الحمل كبير نسبيا بين النتائج العملية و النتائج النظرية و الفرق يتراوح بين 33% إلى 40%.


Article
An Experimental Study of the Effect of Vortex Shedding on Solar Collector Performance
دراسة عملية لتأثير انبثاق الدوامات على كفاءة المجمع الشمسي

Author: Alaulddin Abdulqader Kadim علاء الدين عبد القادر كاظم
Journal: Al-Khwarizmi Engineering Journal مجلة الخوارزمي الهندسية ISSN: 18181171 23120789 Year: 2014 Volume: 10 Issue: 3 Pages: 25-38
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

In this work, the effect of vortex shedding on the solar collector performance of the parabolic trough solar collector (PTSC) was estimated experimentally. The effect of structure oscillations due to wind vortex shedding on solar collector performance degradation was estimated. The performance of PTSC is evaluated by using the useful heat gain and the thermal instantaneous efficiency. Experimental work to simulate the vortex shedding excitation was done. The useful heat gain and the thermal efficiency of the parabolic trough collector were calculated from experimental measurements with and without vortex loading. The prototype of the collector was fabricated for this purpose. The effect of vortex shedding at different operation conditions was examined. The variation of angles of attack and wind velocity leads to different values of vortex loading coefficients and shedding frequencies. The relation between the dynamic characteristics and solar collector performance was evaluated. The finite element method was used to estimate the dynamic characteristic of the solar collector in addition to experimental work to evaluate the relation between the dynamic behavior of the collector and its performance. في هذا البحث, أجريت دراسة تأثير انبثاق الدوامات على أداء المجمع الشمسي المصمم بشكل القطع المكافئ عملياً. تناولت الدراسة تأثير تذبذب الهيكل الناتج عن انبثاق الدوامات على نقصان كفاءة أداء المجمع. وتضمنت الدراسة حساب أداء المجمع باستخدام الكسب الحراري والكفاءة الحرارية. وقدمت محاكاة الإثارة الناتجة عن انبثاق الدوامات عملياً. تضمن البحث حساب الكسب الحراري والكفاءة الحرارية للمجمع الشمسي من قياسات عملية بدون تأثير انبثاق الدوامات وبوجود تأثير انبثاق الدوامات. كما وتم تصنيع انموذج من المجمع الشمسي لهذا الغرض. وتناولت الدراسة ايضا تأثير انبثاق الدوامات عند ظروف تشغيل مختلفة. ان تغيير زوايا الهجوم وسرعة الرياح تؤديان الى قيم مختلفة في معاملات الحمل الناتج عن الدوامات وكذلك تردد انبثاقها. تم ايجاد العلاقة بين الخواص الديناميكية للمجمع الشمسي وأداء المجمع الشمسي. كذلك استخدمت طريقة العناصر المحددة لدراسة المواصفات الديناميكية للمجمع الشمسي فضلا عن الجانب العملي لتقويم العلاقة بين السلوك الديناميكي للمجمع وأدائه.


Article
Energy Saving of Heat Gain by Using Buried Pipe Inside a Roof
ترشيد في كسب الطاقة الحرارية بأستخدام الأنابيب المدفونة في السقف

Author: Ahmed A. M. Saleh أحمد عبد محمد صالح
Journal: Al-Khwarizmi Engineering Journal مجلة الخوارزمي الهندسية ISSN: 18181171 23120789 Year: 2015 Volume: 11 Issue: 1 Pages: 32-39
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

This work deals with a numerical investigation to evaluate the utilization of a water pipe buried inside a roof to reduce the heat gain and minimize the transmission of heat energy inside the conditioning space in summer season. The numerical results of this paper showed that the reduction in heat gain and energy saving could be occurred with specific values of parameters, like the number of pipes per square meter, the ratio of pipe diameter to the roof thickness, and the pipe inlet water temperature. Comparing with a normal roof (without pipes), the results indicated a significant reduction in energy heat gain which is about 37.8% when the number of pipes per meter of roof length is 3.0 , the ratio of pipe diameter to the wall thickness (D/W) is 0.20, and the water inlet temperature is 30°C, while the minimum ratio of reduction 24% is achieved when the number of pipes per meter, the ratio of pipe diameter to the wall thickness, and the water inlet temperature are 27, 30 and 33 °C, respectively. The results also showed that there is a very small effect of pipe centre position inside the wall on the final heat transmission. في هذا العمل أجريت دراسة عددية لمعرفة تأثير أنابيب الماء المدفونة في السقوف على تقليل الكسب الحراري ومنع انتقال الحرارة الى داخل الفضاءات المكيفة. وأضهرت نتائج البحث أن هنالك أمكانية لتقليل الكسب الحراري عند قيم محددة من العوامل المؤثرة مثل عدد الأنابيب للمتر الواحد من عرض السقف ونسبة قطر الأنبوب الى سمك السقف (D/W) و درجة حرارة الماء الداخل الى الأنبوب. حيث بينت النتائج ان هنالك تخفيض بنسبة 40 % مقارنة مع السقف الخالي من الأنابيب عندما يكون عدد الأنابيب للمتر الواحد هو 3 ونسبة قطر الأنبوب الى سمكه بحدود 0.5 ودرجة حرارة الماء الداخل الى الأنبوب هي °C30 ، بينما بلغت أقل نسبة من التخفيض وهي 14 % عند عدد الأنابيب يساوي 1 لكل متر من عرض السقف ونسبة قطر الأنبوب الى سمك السقف هي 0.5 ايضاً ولكن درجة حرارة الماء الداخل الى الأنبيب هي °C33 وكلاهما عند عدد رنولدز للماء المنساب خلال الأنبوب هو 3000 . كما وأضهرت النتائج بأن هنالك تأثير بسيط جداًعلى كمية الحرارة المنتقلة خلال السقف عند تغيير موقع مركزالأنبوب داخل السقف.


Article
THEORATICAL ANALYSIS OF FLAT PLATE SOLAR COLLECTOR PLACED IN MOSUL CITY BY USING DIFFERENT ABSORBING MATERIALS AND FLUIDS
دراسة نظرية لمجمعات شمسية ذات صفائح مستوية موضوعة في مدينة الموصل باستخدام معادن وموائع مختلفة

Authors: Hasson S. Hamood حسون شعبان حمود --- Badran M. Salim بدران محمد سالم --- Nabeel M. Abdulrazzaq نبيل مخلف عبدالرزاق
Journal: KUFA JOURNAL OF ENGINEERING مجلة الكوفة الهندسية ISSN: 20715528 Year: 2015 Volume: 6 Issue: 2 Pages: 1-12
Publisher: University of Kufa جامعة الكوفة

Loading...
Loading...
Abstract

In this paper, a mathematical model and simulation of flat plate solar collector are developed. The weather data, which used in the calculations of the performance of the collector, is for Mosul city. Detailed energy analyses were carried out for evaluating the efficiency and useful heat gain of a typical flat plate solar collector under certain operation and design conditions. In this analysis, different fluids and different absorbing materials were used to indicate there affect on the performance of flat plate solar collector. Operating parameters, which considered as variables, are the mass flow rate, the inlet and the outlet temperature difference and the total solar radiation flux. The simulation program had written by using EES (Engineering Equation Solver) software program. The results of this analysis show that the copper and aluminum give a good efficiency up to 0.6 with value (ΔT/GT = 0.03) with water as a working fluid, while the plain carbon steel gives less than the number that stated previously. The results show also that the copper and the aluminum give the largest useful heat gain extracted from the collector as compared with plain carbon steel. It has been also show that the solar collector efficiency is higher in case of using water as working fluid than that of propylene glycol solution. يتضمن البحث الحالي إنشاء نموذج رياضي لمجمعات شمسيه ذات صفائح مستوية بغرض محاكاة النموذج الواقع تحت تأثير أجواء مدينة الموصل من درجات الحرارة العظمى والصغرى بغرض تحديد كفاءة تلك المجمعات الشمسية. حيث تم اجراء تحليل مفصل للطاقة الشمسية بغرض تقييم كفاءة هذه المجمعات الشمسية و الحرارة النافعة المكتسبة تحت ظروف تشغيلية وتصميمية معينة. تم أستخدام الماء ومحلول البروبلين كلايكول كموائع تشغيل في المنظومة قيد الدراسة بينما أستخدم النحاس و الالمنيوم و الصلب الكاربوني كمعادن للصفائح الماصة للحرارة في المجمع الشمسي. تم أختبار معدل الجريان الكتلي للمائع والتغير في درجة حرارة المائع الداخل والخارج من المجمع الشمسي بالإضافة الى التغير في مقدار فيض الاشعاع الشمسي كظروف تشغيلية للمنظومة. تم بناء برنامج حسابي لمحاكاة المجمع الشمسي وذلك باستخدام الوسط )ولقد أظهرت النتائج المستحصل عليها من خلال البرنامج أن أستخدام النحاس EESالبرمجي لحل المعادلات الهندسية ( عندما تكون قيمة 0.6 والالمنيوم كصفائح ماصة للحرارة تعطي أعلى كفاءة يصل مقدارها إلى (ΔT/GT=0.03) كما أظهرت النتائج أ ، باستخدام الماء كمائع تشغيل في المنظومة ن النحاس والالمنيوم يعطون أعلى كمية من الطاقة ًأيضا النافعة بالمقارنة مع الصلب الكاربوني بالاضافة الى أستنتاج أن استخدام الماء كمائع للتثليج اعطى كفاءة اعلى مقارنة مع البروبلين كلايكول.


Article
Cooling and Heating a Greenhouse in Baghdad by a Solar Assisted Desiccant System
تبريد وتدفئة بيت زجاجي في بغداد بأستخدام منظومة امتزازية تعمل بمساعدة الطاقة الشمسية

Authors: Khalid Ahmed Joudi خالد أحمد الجودي --- Mustafa Moayad Hasan مصطفى مؤيد حسن
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2013 Volume: 19 Issue: 8 Pages: 933-951
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Modeling the microclimate of a greenhouse located in Baghdad under its weather conditions to calculate the heating and cooling loads by computer simulation. Solar collectors with a V-corrugated absorber plate and an auxiliary heat source were used as a heating system. A rotary silica gel desiccant dehumidifier, a sensible heat exchanger, and an evaporative cooler were added to the collectors to form an open-cycle solar assisted desiccant cooling system. A dynamic model was adopted to predict the inside air and the soil surface temperatures of the greenhouse. These temperatures are used to predict the greenhouse heating and cooling loads through an energy balance method which takes into account the soil heat gain. This is not included in conventional methods. The results showed satisfactory agreement with published papers. Also, the results of heating and cooling loads obtained revealed good agreement with those obtained from conventional methods when the soil heat gain is included. Two identical collectors in series of total area of 5.4m2 were employed as a heating system which provides an outlet air temperature of 30 oC at air mass flux of 0.06 kg/s.m2 at midday in January. While, a 65 oC outlet air temperature was achieved for the same mass flux at midday in August. The desiccant cooling system was operated in five operating modes; the ventilation mode and four recirculation modes with 20%, 50%, 70%, and 90% recirculation. The simulation results showed that a regeneration temperature of 60-70 oC is satisfactory for a cool supply air temperature of about 19.5 oC. Also, it was noted that 20-30 % recirculation of return air would result in suitable indoor greenhouse conditions for most periods of system operation. In addition, the coefficient of performance COP of the system was high compared with the conventional vapor compression systems. يُعنى هذا البحث بنمذجة البيئه الداخلية لبيت زجاجي في بغداد وتحت ظروفها المناخية الحقيقية لحساب حملي التدفئه والتبريد بأستخدام تقنيه الحاسوب. مجمعات شمسيه ذات صفيحة امتصاص مضلعه ومصدر حراري مساعد استخدمت كمنظومة تدفئة مع قرص تجفيف دوار محشو بمادة تجفيفيه هي السيليكاجيل ومبادل حراري لأنتزاع الحرارة المحسوسه ومبرد تبخيري الى منظومة التدفئه لتكوين منظومة تبريد امتزازيه مفتوحه تعمل بمساعدة الطاقه الشمسيه. استخدمت النمذجة الديناميكية للتنبؤ بدرجتي حرارة هواء البيت الزجاجي وسطح تربته إذ تعد هاتين الدرجتين اساسيتين في حساب حملي التدفئه والتبريد للبيت الزجاجي بطريقة توازن الطاقه. هذه الطريقة وبخلاف الطرق التقليديه المتبعه تأخذ بنظر الأعتبار الكسب الحراري من سطح التربه. أظهرت النتائج تقارباً واضحاً مع نتائج نماذج اُخرى لبحوث منشورة. كما ان أحمال التدفئة والتبريد التي حسبت كانت متطابقة مع نتائج الطرق التقليديه عند اضافة الكسب الحراري من التربة الى تلك الطرق. اقتصرت منظومة التدفئة على زوج متماثل من المجمعات بمساحة كلية 5.4 م2 والتي أعطت هواء بدرجة حرارة 30o م وبمعدل تدفق 06,0 كغم/ثا لكل متر مربع من مساحة المجمع في منتصف النهار في شهر كانون الثاني. بينما تم الحصول على هواء بدرجة حرارة 65o م ولمعدل التدفق نفسه في منتصف النهار في شهر آب.تم تشغيل منظومة التبريد الأمتزازيه بخمس طرق تشغيل وهي نمط التهويه واربع انماط من اعادة التدوير; 20%, 50%, 70%, و 90% من الهواء الراجع. وقد أظهرت نتائج محاكاة المنظومه بأن درجة حرارة اعادة النتشيط بين 60-70 o م تعطي نتائج أفضل من حيث درجة حرارة تجهيز الهواء والتي بلغت تقريباً 19.5 o م عندما كانت الظروف الداخليه 28 o م و رطوبه نسبيه 70%. كذلك فأن تشغيل المنظومه مع تدوير الهواء الراجع بنسبة 20-30% يوفر ظروف ملائمه داخل البيت الزجاجي ولمعظم ساعات التشغيل. وجد ايضاً أن معامل أداء منظومة التبريد الامتزازيه عالي جداً مقارنة بأجهزة تكييف الهواء الأنضغاطية.

Listing 1 - 5 of 5
Sort by
Narrow your search

Resource type

article (5)


Language

English (3)

Arabic and English (2)


Year
From To Submit

2015 (2)

2014 (1)

2013 (1)

2005 (1)