research centers


Search results: Found 26

Listing 1 - 10 of 26 << page
of 3
>>
Sort by

Article
The Characteristic Performance of Fluidized bed Ion Exchange
دراسة محددات اداء العمود الايوني ذو الطبقة المسيلة

Authors: Malik M. Mohamed مالك مصطفى --- Nahidh W. Kaseer ناهض وديع قيصر --- Iman Haider Mahdi ايمان حيدر مهدي
Journal: AL-NAHRAIN JOURNAL FOR ENGINEERING SCIENCES مجلة النهرين للعلوم الهندسية ISSN: 25219154 / eISSN 25219162 Year: 2009 Volume: 12 Issue: 1 Pages: 38-47
Publisher: Al-Nahrain University جامعة النهرين

Loading...
Loading...
Abstract

The aim of this work is to study the characterization of ion exchange in important characteristics (i.e., breakthrough time and exchange capacity) by investigation the performance of cation exchange column subjected to makeup solution in term of three different parameter (i.e., bed depth 5-45cm, NaCl salt concentration100-2000 ppm and feed flow rate 9.5-26.5l/h). Two second order polynomial model are proposed with Box Wilson composite rotatable design. The experimental result had shown an efficient performance of using ion exchange column with strong acid cation exchange resin in fluidized mode operation which given maximum breakthrough time and higher exchange capacity means the rate of exchange is very rapid to completed the removing of all undesired ions at a condition of low bed depth, high NaCl concentration and high feed flow rate

يهدف البحث المقدم الى دراسة العوامل المؤثرة في اداء المبادلات الايونية من خلال قياس خاصيتين مهمتين هما زمن الاستنفاذ وقابلية التبادل عن طريق بحث اداء عمود للمبادلات الايونية الموجبة معرض لمحاليل مياه محضرة مختبريا من خلال ثلاثة متغيرات مختلفة (ارتفاع الطبقة 5- 45 سم , تركيز محلول ملحي من كلوريد الصوديوم 100-2000 جزء بالمليون ومعدل جريان المغذي 9,5- 26,5 لتر/ساعة).ُافترضت معادلتان متعددة الحدود من الدرجة الثانية واوجدت حدودها بطريقة بوكس ويلسن للتحليل الارتدادي اللاخطي .وقد اظهرت النتائج العملية كفاءة استخدام عمود المبادل الايوني الموجب الحامضي القوي بطريقة الطبقة المسالة والذي يعطي اعلى زمن للاستنفاذ واعلى قابلية للتبادل والذي يعني ان معدل التبادل سريع جدا للقيام باكمال ازالة جميع الايونات غير المرغوبة تحت ظروف تشغيلية اقل ارتفاع للطبقة,اعلى تركيز لكلوريد الصوديوم واعلى معدل جريان للمغذي.

Keywords

Fluidization --- Ion Exchange


Article
Synthesis, Characterization of polyacrylamide as chelating agent for some metal ions

Author: Asmahan A.Abdulla , Hassan T. Abdulsahib and Nadhum A.NAwad
Journal: Journal of Basrah Researches (Sciences) مجلة ابحاث البصرة ( العلميات) ISSN: 18172695 Year: 2006 Volume: 32 Issue: 1A Pages: 75-80
Publisher: Basrah University جامعة البصرة

Loading...
Loading...
Abstract

A polyacrylamide was prepared by applying the solution technique used for synthesis of organic polymer. It was characterized by different techniques such as elemental analysis , Infrared spectroscopy and thermal analysis .The extracting efficiency of the resin was studied toward several metal ions from their diluted solutions (50ppm) by atomic absorption spectrometry .The effect of pH and treatment time on the chelating efficiency of the resin was examined and the optimum conditions were found, the chelating efficiency of the resin decrease with pH less than 1.5 and from 1.5 to 7.5 above that the resin became soluble. The loading capacities of the resin for Zn2+,Cd2+,Cu2+and Pb2+ ions were found to be 1.40,1.0,0.62 and 0.42 mg ion/gm resin respectively. The recovery efficiency of these ions was also studied as a function of treating time and the pH of the acidic eluent, and it was found to be in the sequence of Zn2+>Cd2+>Cu2+>Pb2+.

في الدراسة الحالية تم تحضير راتنج البولي اكريل امايد بطريقة تحضير البوليمرات العضوية ،تم تشخيص هذا الراتنج باستخدام تقنيات التحليل الحراري،التحليل العنصري ومطيافية الأشعة تحت الحمراء . تم دراسة كفاءة الراتنج في استبدال عدد من الايونات المعدنية من محاليلها المخففة (50 جزء بالمليون )بإتباع تقنية الامتصاص الذري و دراسة تأثير كل من الحامضية و زمن المعاملة على كفاءة الراتنج التبادلية حيث وجد أن الكفاءة الاستبدالية للراتنج تجاه الايونات المدروسة كالأتي:الزنك> الكادميوم> النحاس>الرصاص إذ تم حساب سعة تحمل الراتنج لكل ايون فكانت 0.42،0.62،1.0،1.4 ملغم ايون /غرام من الراتنج على التوالي و بذلك فان الراتنج أبدى كفاءة عالية في الاستبدال تجاه تلك الايونات، حيث إن هذه الكفاءة تعتبر دالة مع الزمن و الدالة الحامضية من ناحية أخرى درست كفاءة استعادة الايونات من الراتنج بمعاملتها مع محلول حامض الهيدروكلوريك المخفف وقد وجد أن استعادة هذه الايونات حسب الترتيب الآتي: الزنك> الكادميوم> النحاس>الرصاص .


Article
A Novel Semi Automated On-Line Determination of Oxonium Ion Via Precipitation Reaction Using a New Mode of Attenuated Measurement of Incident Light (0 – 180o) by AYAH 5SX4-ST-5D Solar CFI Analyser.
تقدير نبيل اني شبه تلقائي لأيون الأوكسونيوم عن طريق تفاعل الترسيب بأستخدام نمط جديد لقياس توهين الضوء الساقط بزاوية (0-180˚) بوساطة AYAH 5SX4-ST-5D solar CFI analyser

Authors: Hussein F. A. AL-Razack حسين فارس عبد الرزاق الجبوري --- Issam M. A. Shakir عصام محمد علي شاكر الهاشمي
Journal: Iraqi Journal of Science المجلة العراقية للعلوم ISSN: 00672904/23121637 Year: 2014 Volume: 55 Issue: 4B Pages: 1736-1750
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Strong acids were determined via the precipitation reaction of loaded copper (II) ion on strong cation exchange resin which in turn reacts with potassium hyxacyano ferrate (II). The attenuation effect of formed precipitate Cu2 [Fe (CN) 6] on (0 -180o) incident LED light was measurement via homemade AYAH 5SX4-ST-5D solar CFI analyser. Optimum parameters were 0.005M.L-1 [Fe(CN)6]-4 , flow rate of 2.4 mL.min-1 , sample volume 204 µL , sample purge time of 64 seconds was chosen, and 1.6 V for light intensity. A liner calibration graph of 0.005 -0.2 M.L-1 were obtains for HCl, HNO3, HCLO4 and H2SO4, with a linearity (r2 %) 96 -97 % and L.O.D based on gradual dilution of lowest concentration in calibration graph was 37.19 µg for HCl, 64.273 µg for HNO3, 102.26 µg for HCLO4, and 0.01 µg for H2SO4 .Repeatability (RSD %) less than 1.12 was obtained. the proposed was compared well with standard method. FTU method for available acid in commercial ( HCl, H2SO4).

قدرت الحوامض القوية عن طريق تفاعل الترسيب والمعتمد على التفاعل بين ايون النحاس الثنائي والمحمل على مبادل ايوني حامضي قوي و بوناسيوم سداسي ثايوسيانات الحديد (II). قياس توهين الضوء المسلط بزاوية ( 0-180˚) والمعتمد على تكوين راسب Cu2 [Fe (CN) 6] يتم عن طريق محلل الحقن الجرياني المستمر والمصنع محليا AYAH 5SX4-ST-5D solar CFI analyser. تم اختيار الظروف الفضلى 0.005مول.لتر-1 [Fe(CN)6]-4 وسرعة الجريان 2.4 مل. دقيقة-1 ,حجم الأنموذج المحقن 204مايكروليتر ,زمن حقن الأنموذج 64 ثانية ويالأضافة الى 1.6 فولت وهي شدة الضوء الساقط . منحني معايرة بحدود 0.005 – 0.2 مول .لتر-1 لكل من HCl, HNO3, HClO4 بالأضاقة الى H2SO4مع نسبة خطيه (r2% ) تمتد من 96- 97 % بالأضافة الى حدود الكشف (LOD ) والمستندة على التخفيف التدريجي لأقل تركيز في منحني المعايرة 73.19ملغم لأنموذج HCl , 64.273مكغم لـ HNO3 , 102.26 مكغم لـ HClO4 بالأضافة الى 0.01 مكغم لـ H2SO4 . تم الحصول على تكرارية (RSD% ) اقل من 1.12 .وقد تم مقارنة الطريقة المقترحة مع الطريقة الكلاسيكية لكل من الحوامض المتوفرة (HCl , H2SO4).


Article
New mode for the on-line determination of oxonium ion in differentstrong acids using CFIA via the use of homemade linear array Ayah 5Sx4-ST- 5D solar CFI analyser
طريقة جديدة انيه لتقدير ايون الاوكسونيوم في الحوامض القويه المختلفة باستخدام تقنيه التحليل بالحقن الجرياني المستمر من خلال استخدام محلل الحقن الجرياني المستمرlinear array Ayah 5Sx4-ST- 5D solar

Authors: Issam M. A. Shakir عصام محمد علي شاكر --- Hussein F. A. AL-Razack حسين فارس عبد الرزاق
Journal: Iraqi Journal of Science المجلة العراقية للعلوم ISSN: 00672904/23121637 Year: 2015 Volume: 56 Issue: 1B Pages: 282-302
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Strong acids were determined via the blue complex solution reaction of a loaded ferric (III) ion on strong cation exchange resin which in turn reacts with potassium hyxacyano ferrate (II). The attenuation effect of formed blue complexFe4([Fe(CN)6])3on (0 -180o) incident LED light was measurement via homemade linear array AYAH 5SX4-ST-5D solar CFI analyser. Optimum parameters were 0.005M.L-1 [Fe(CN)6]-4 , flow rate of 3mL.min-1 , sample volume 204 µL , sample purge time of 70 seconds was chosen, and 1V for light intensity. A liner calibration graph of 0.005 -0.15 M.L-1 were obtains for HCl, HNO3, HCLO4 and H2SO4, with a linearity (r2 %) 94 -98 % and L.O.D based on gradual dilution of lowest concentration in calibration graph was 22.314 µg for HCl, 38.563 µg for HNO3,61.480 µg for HCLO4, and 60.020 µg for H2SO4 .Repeatability (RSD) 0.5% was obtained. the proposed method was compared with standard method. turbidity measured using HANNA instrument for available acid in commercial (HCl, H2SO4).

قدرت الحوامض القوية عن طريق محلول معقد ازرق والمعتمد على التفاعل بين ايون الحديد الثلاثي والمحمل على مبادل ايوني حامضي قوي وبوناسيوم سداسي ثايوسيانات الحديد (II). قياس توهين الضوء المسلط بزاوية ( 0-180˚) والمعتمد على تكوين معقد ازرق Fe4([Fe(CN)6])3 يتم عن طريق محلل الحقن الجرياني المستمر والمصنع محليا linear array AYAH 5SX4-ST-5D solar CFI analyser. تم اختيار الظروف الفضلى 0.005مول.لتر-1[Fe(CN)6]-4 وسرعة الجريان 3 مل. دقيقة-1 ,حجم الأنموذج المحقن 204مايكروليتر ,زمن حقن الأنموذج 70 ثانية ويالأضافة الى 1 فولت وهي شدة الضوء الساقط . منحني معايرة بحدود 0.005 – 0.15 مول .لتر-1 لكل من HCl, HNO3, HClO4 بالأضاقة الى H2SO4مع نسبة خطيه (r2% ) تمتد من 94- 98 % بالأضافة الى حدود الكشف (LOD ) والمستندة على التخفيف التدريجي لأقل تركيز في منحني المعايرة 22.314مكغم لأنموذج HCl , 56.38مكغم لـ HNO3, 48.61 مكغم لـ HClO4بالأضافة الى 02.60مكغم لـ H2SO4 . تم الحصول على تكرارية (RSD% ) 0.5% .تم مقارنة الطريقة المقترحة مع الطريقة الكلاسيكية(قياس التعكريه) باستخدام جهازHANNA لكل من الحوامض المتوفرة (HCl , H2SO4).


Article
Removal of Zinc ions from industrial wastewater with wool fibers
ازالة ايونات الخارصين من مياه المجاري الصناعية بواسطة الياف الصوف

Authors: Ammar W. Ahmed عمار وعد الله احمد --- Salwa Shamran Jassim سلوى شمران جاسم --- Ayad H. Jassim اياد حمزة جاسم
Journal: Baghdad Science Journal مجلة بغداد للعلوم ISSN: 20788665 24117986 Year: 2010 Volume: 7 Issue: 3 Pages: 1193-1201
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

In this research, the efficiency of low-cost unmodified wool fibers were used to remove zinc ion from industrial wastewater. Removal of zinc ion was achieved at 99.52% by using simple wool column. The experiment was carried out under varying conditions of (2h) contact time, metal ion concentration (50mg/l), wool fibers quantity to treated water (70g/l), pH(7) & acid concentration (0.05M). The aim of this method is to use a high sensitive, available & cheep natural material which applied successfully for industrial wastewater& synthetic water, where zinc ion concentration was reduced from (14.6mg/l) to (0.07mg/l) & consequently the hazardous effect of contamination was minimized.

في هذا البحث، تمت الاستفادة من كفاءة الياف الصوف غير المحسنة واطئة الكلفة لازالة ايون الخارصين من مياه المجاري الصناعية. تم ازالة ايون الخارصين بنسبة 99.52% باستخدام عمود الصوف البسيط. تم تنفيذ التجربة عند ظروف مختلفة، حيث ان زمن الاستبقاء (2 ساعة) وتركيز ايون الخارصين (50 ملغم/لتر) وكمية الياف الصوف الى الماء المعامل (70 غم/لتر) والدالة الحامضية(7) وتركيز الحامض (0,05 مولاري). ان الهدف من التجربة هو استخدام مادة طبيعية رخيصة الثمن ومتوفرة بكثره و ذات حساسية عاليه للايونات والتي تم تطبيقها بنجاح على مياه المجاري الصناعية والمياه المصنعة، حيث تم تقليل تركيز ايون الخارصين في هذه المياه من (14.6 ملغم/لتر) الى (0.07 ملغم/لتر) وهكذا تم خفض مستوى التلوث.


Article
Liquid Ion Exchange for Extraction and Spectrophotometric Determination of Tungestate WO4˭ by Use Azo-derivative

Authors: Shawket K. Jawad --- Nadia M. Muslim
Journal: Journals kufa for chamical مجلة الكوفة للكيمياء ISSN: 20772351 Year: 2015 Issue: 10 Pages: 8-20
Publisher: University of Kufa جامعة الكوفة

Loading...
Loading...
Abstract

2-[(4–formylphenayl)azo]-4,5-diphenyl imidazole [FPADPI] used as complexation agent to form ion association complex. pH=8, which is giving higher absorbance at λmax= 460nm , in presence of 50 µgW6+as WO4˭in 5mL and 1×10-4 M of [FPADPI], this study show ion pair complex extracted have a structure 1:1 H-FPADPI]+;HWO4-or [2H-FPADPI]2+;WO4˭, and thermodynamic study show extraction method of WO4˭ was endothermic with thermodynamic data ∆Hex=0.0287 K J mol-1, ∆Gex=-50.83 K Jmol-1and ∆Sex= 167.857 J mol-1K-1as well as this research contain another studies.


Article
Utilization of Thomas model to predict the breakthrough curves for adsorption and ion exchange

Authors: Shahlaa E. Ebrahim --- Yasmen A. Mustafa
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2010 Volume: 16 Issue: 4 Pages: 6206 -6223
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Fixed bed sorption processes such as adsorption and ion exchange do not operate at steady state. The design equations are differential that usually require numerical methods to solve. Thomas gives a general analytical solution for these equations. It is based on second-order reaction kinetics and the assumption of Langmuir isotherm. Computer program for the solution of Thomas model was designed using MATLAB 7.0. Four sets of experimental data are tested to show the capability of Thomas model to predict the breakthrough curves for adsorption and ion exchange processes. These data represent the sorption of o-cresol from water by activated carbon, acetic acid from air by activated carbon, phenol from water by natural zeolite, and trichloroethylene from air by zeolite-5A.The results show that there are a good agreement between the experimental data and the model.

أن عمليات الامتزاز والتبادل الايوني للطور الثابت تكون متغيرة ، فالمعادلات الخاصة بالتصاميم هي معادلات تفاضلية تحتاج الى حلول بالطرق العددية.توماس استطاع أن يعطي حل عام تحليلي لهذه المعادلات مستندا على ديناميكية التفاعل من الدرجة الثانية ومعادلة لانكمير عند التوازن. تم اعداد برنامج رياضي لموديل توماس بأستخدام MATLAB 7.0 . أستخدمت اربعة نماذج من التجارب لغرض أظهار مقدرة موديل توماس للتنبأ بمنحنيات الامتزاز والتبادل الايوني. البيانات مثلت امتزاز الاورثوكريسول من الماء بواسطة الفحم المنشط ، وحامض الخليك من الهواء بواسطة الفحم المنشط، والفينول من الماء بواسطة الزيولايت، وثلاثي كلوروالاثلين من الهواء بواسطة الزيولايت. النتائج بينت ان هناك تطابق جيد بين البيانات العملية والموديل.


Article
RECLAMATION OF PCB WASTEWATER

Authors: Matheel D. Al-Sabtia --- Nahidh W. Kasser --- Mudhafar Y. Hussein
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2008 Volume: 26 Issue: 11 Pages: 1326-1340
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

Wastewater from electronic printed circuit board (PCB) factories was subjectedto lab-scale ion exchangers of two types: strong acid cation followed by weak baseanion exchanger. The experimental investigation was directed to study the ionexchanger performance in terms of three different parameters namely (TDS, feedrate and bed depth). Box-Wilson composite rotatable design was adopted indesigning the experiments. Breakthrough times of (PCB) wastewater were studiedthrough TDS ranged between 317 to 1193 ppm, feed rate ranged between 0.712 to4.980 l/h, and bed depth of cation exchanger ranged between 9.4 to 60.6 cm andanion exchanger ranged between 14.3 to 91.0 cm.Simulation the effect of the studied variables through their pre-designed rangesin terms of breakthrough time by 2nd order polynomial equation was obtained. Ingeneral, the performance and characteristics of adopting two bed deionizers (cationand anion beds) was proved efficient for the removal of the ionic contaminants andnot less than 95 % of wastewater is recycled. In addition, the research considers thetreatment of highly metals content regenerant solution out coming fromreclamation system to minimize its metal content. The reclamation of wastewaterwas studied in terms of breakthrough time (i.e., the leakage of the cations).

يهدف البحث الى دراسة العوامل المؤثرة على أداء المبادلات الأيونية (مبادل الأيونات الموجبةالحامضي القوي ومبادل الأيونات السالبة القاعدي الضعيف) لمعالجة المياه المطروحة من مصانع إنتاجالدوائر الإلكترونية المطبوعة. تم دراسة استرداد ومعالجة مياه الفضلات من خلال قياس خاصية زمنالاستنفاذ للمبادلات الأيونية وإستجابة هذه المبادلات لتأثير ثلاث متغيرات هي تركيز الأملاح الذائبةالكلية، معدل الجريان، وعمق الطبقة. أستخدمت طريقة بوكس ولسن في تصميم التجارب العمليةوافترضت علاقات رياضية متعددة الحدود من الدرجة الثانية لربط كفاءة أداء المبادلات الأيونية بدلالةزمن الاستنفاذ للمتغيرات الثلاث آنفة الذكر.تم قياس زمن الاستنفاذ عمليا" بإستخدام مياه الفضلات المطروحة بالظروف التالية: تركيز الأملاحالكلية الذائبة من 317 الى 1193 جزء بالمليون، معدل جريان المغذي من 0.71 الى 4.98 لتر بالساعةوعمق طبقة مبادل الأيونات الموجبة من 9.4 الى 60.6 سم وعمق طبقة مبادل الأيونات السالبة من 14.3الى 91.0 سم. أشارت النتائج العملية المستحصل عليها على كفاءة استخدام منظومة التبادل الأيونيللتخلص من كافة OH- ومبادل الأيونات السالبة بصيغة H+ المتكونة من مبادل الأيونات الموجبة بصيغةأيونات العناصر الثقيلة السامة والأيونات السالبة المرافقة لها وكافة الأيونات الموجبة والسالبة للأملاحالذائبة في الماء

Keywords

Wastewater --- Ion Exchange --- TDS --- Feed Rate --- Bed Depth.


Article
Purification and characterization of hemolysin produced by a local isolates of Staphylococcus aureus

Authors: Mohammed I. Nadir --- Hussain S. Al-Hassani --- Amer H. Al-Shammary
Journal: Karbala Journal of Medicine مجلة كربلاء الطبية ISSN: 19905483 Year: 2012 Volume: 5 no 2 Issue: 12 Pages: 1455-1463
Publisher: Kerbala University جامعة كربلاء

Loading...
Loading...
Abstract

background: Staphylococcus aureus is a ubiquitous bacterium that is generating increasingly bad press coverage due to its propensity to adopt a pathogenic lifestyle in hospital and community settings. S. aureus colonies are found in approximately 30% of the general population. It colonizes the skin readily and can lead to a wide range of pathological conditions from skin lesions to osteomyelitis, endocarditis, and septicemia. Hemolysins are extracellular toxic proteins which are produced by many gram negative (e.g. Escherichia coli, Serratia spp., Proteus spp., Vibrio spp., Pasteurella spp., Pseudomonas aeruginosa) and gram positive bacteria (e.g. Streptococcus spp., Staphylococcus aureus, Listeria spp., Bacillus cerius, Clostridium tetani), all of which possess a certain pathogenic potential. Hemolysins have been therefore always considered as virulence factors. Most hemolysins cause lysis of erythrocytes by forming pores of varying diameters in the membrane and are designated as such because they have the ability to lyse red blood cells (RBCs). Objectives1-Purification of hemolysin from a local isolate of S. aureus.2-Characterization of hemolysin produced by a local isolate of S. aureus.Methods: Bacterial samples were identified by subjecting them to the standard laboratory procedures while semi quantitative screening on blood agar (containing 5% human blood) revealed that all isolates were hemolysin producer but in different efficiencies. Hemolysin was extracted by cooling centrifugation and purified by many steps including: precipitation by ammonium sulphate, dialysis, ionic exchange chromatography by using DEAE-Cellulose, and gel filtration chromatography by using Sephadex G-100. The molecular weight of hemolysin was determined by gel filtration chromatography on Sephadex G-100 while the optimum pH and temperature for hemolysin stability were also determined.Results: The results showed that forty isolates out of 100 were identified as Staphylococcus aureus. Hemolysin was extracted by cooling centrifugation and purified by many steps including: precipitation by ammonium sulphate with 50-75% saturation percentage, dialysis, ionic exchange chromatography by using DEAE-Cellulose, and gel filtration chromatography by using Sephadex G-100. The results showed that hemolysin was purified 135 fold with a yield of 1.16%.The molecular weight of hemolysin determined by gel filtration chromatography on Sephadex G-100 column was about 35000 daltons, while the optimum pH for enzyme stability was 7 and the optimum temperature for enzyme stability was between 25-35oC.Conclusions1.Conventional methods can be performed to extract hemolysins.2.Hemolysin was maximally produced when the pH was near neutrality and incubation temperature was 37oC and this conclusion indicates that hemolysin was produced when the conditions were similar to that of the host.


Article
Removal of Cu2+, Pb2+, And Ni2+ Ions From Simulated Waste Water By Ion Exchange Method On Zeolite And Purolite C105 Resin
ازاله ايونات النحاس,الرصاص والنيكل من المياه الملوثه بطريقه التبادل الايوني باستخدام راتنجات الزيولايت والبيورلايت

Authors: Ahmed Abed Mohammed احمد عبد محمد --- Haidar Shukur Mahmood حيدر شكر محمود
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2013 Volume: 19 Issue: 10 Pages: 1327-1340
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The removal of heavy metal ions from wastewater by ion exchange resins ( zeolite and purolite C105), was investigated. The adsorption process, which is pH dependent, shows maximum removal of metal ions at pH 6 and 7 for zeolite and purolite C105 for initial metal ion concentrations of 50-250 mg/l, with resin dose of 0.25-3 g. The maximum ion exchange capacity was found to be 9.74, 9.23 and 9.71 mg/g for Cu2+, Pb2+, and Ni2+ on zeolite respectively, while on purolite C105 the maximum ion exchange capacity was found to be 9.64 ,8.73 and 9.39 for Cu2+, Pb2+, and Ni2+ respectively. The maximum removal was 97-98% for Cu2+ and Ni2+ and 92-93% for Pb2+ on zeolite, while it was 93-94% for Cu2+, 96-97% for Ni2+, and 87-88% for Pb2+ on purolite C105. The obtained sorption affinity sequence was Cu2+> Ni2+> Pb2+ in both resins. Langmuir isotherm expressions were found to give better fit to the experimental data compared to Freundlich and BET models. Kinetic data correlated well with Lagergren first order kinetic model, indicating the reversible reaction with an equilibrium being established between liquid and solid phase.

ازالة المعادن الثقيلة من مياه الصرف الصحي بواسطة راتنجات التبادل الايوني, مثل الزيولايت و البيورولايت تمت دراستها بطريقة الدفعة. ، والتي تعتمد على الدالة الهيدروجينية ، يظهر الحد الأقصى لإزالة ايونات المعادن في درجة الحموضة بين 6 و 7 للزيولايت والبيورولايت لتركيز المعادن الأولية للايونات 50-250 ملغم / لتر ، مع جرعة من الراتنج من 0.25 الى 3 وتم التوصل إلى توازن في ساعتين. تم ايجاد السعة القصوى للتبادل الايوني لتكون 9.74 ملغ / غ للنحاس، 9.23 ملغ / غ للرصاص و 9.71 ملغ / غ للنيكل على راتنج الزيولايت بينما على راتنج البيورولايت السعة القصوى للتبادل الايوني كانت 9.64 ملغ / غ للنحاس 8.73 ملغ / غ للرصاص و 9.39 ملغ / غ للنيكل .وان نسبه الازالة القصوى كانت 97- 98% للنحاس و النيكل و حوالي 92-93% للرصاص على راتنج الزيولايت في حين كانت نسبة الازالة القصوى على راتنج البيورولايت حوالي 93 -97 % للنحاس و النيكل و 87-88% للرصاص. تم ايجاد ان تعبير لانكمير هو الملائم اكثر لتمثيل هذه البيانات المختبرية مقارنة بفريندلخ و بي اي تي . البيانات الحركية تبين انها ملائمة مع الدرجة الاولى, مشيرة الى ان التفاعل عكسي مع التوازن الذي يجري بين السائل و المادة الصلبة .

Listing 1 - 10 of 26 << page
of 3
>>
Sort by
Narrow your search

Resource type

article (26)


Language

English (23)

Arabic and English (3)


Year
From To Submit

2019 (3)

2018 (2)

2016 (3)

2015 (4)

2014 (4)

More...