research centers


Search results: Found 7

Listing 1 - 7 of 7
Sort by

Article
PV SOLAR PANEL PERFORMANCE IN IRAQ USING MATLAB
اداء الخلية الشمسية في العراق باستخدام الماتلاب

Authors: Abdulrahman Th. Mohammad --- Zuhair S. Al-Sagar
Journal: DIYALA JOURNAL OF ENGINEERING SCIENCES مجلة ديالى للعلوم الهندسية ISSN: 19998716/26166909 Year: 2017 Volume: 10 Issue: 2 Pages: 86-93
Publisher: Diyala University جامعة ديالى

Loading...
Loading...
Abstract

Baghdad is the capital city of Iraq and located at 33° 20’ 19" North latitude and 44° 23’38" East longititude. In this paper, a MATLAB model is investigated to simulate the characteristics output of a photovoltaic solar module with respect to changes in operating temperature and solar irradiance. The model is able to predict the output current and output voltage, as well as the output power. The results show that the current, voltage and output power of PV-collector increase by 80%, 17.5%, and 85.5%, respectively when the solar irradiance increases from 200 to 1000 W/m2, but the current almost unchanged and the voltage and output power decrease by 9% and 18.5% respectively when the operating temperature changes from 25 oC to 45 oC.

بغداد عاصمة العراق وتقع على خط 33° 20’ 19" شمالا و 44° 23’38" شرقا. في هذا البحث تم تحقيق برنامج باستخدام الماتلاب لحل خصائص خلية شمسية طبقا لتغير شدة الاشعاع الشمسي ودرجة الحرارة. البرنامج حقق حساب التيار والفولطية والقدرة الخارجة من الخلية الشمسية. وقد بينت النتائج ان التيار والفولطية والقدرة الخارجة تزداد بنسبة 80% 17.5%, , 85.5% على التوالي في حالة زيادة الاشعاع الشمسي من 200 الى 1000 W/m2 لكن التيار لا يتغير في حالة تغير درجة الحرارة من 25 الى 45 درجة مئوية اما الفولطية والقدرة فسوف تقل بنسبة 9% و 18% على التوالي في حالة زيادة درجة الحرارة من 25 الى 45 درجة مئوية.


Article
Effect of Colored Filters on PV Panels Temperature and Performance under Baghdad Meteorological Condition
تأثير الفلاتر الملونة على حرارة واداء االلواح الكهروضوئية تحت الظروف الجوية لمدينة بغداد

Authors: Abdulmunem R. Abdulmunem --- Abdullateef A. Jadallah --- Hisham A. Hoshi --- Mohammed H. Jabal
Journal: Tikrit Journal of Engineering Sciences مجلة تكريت للعلوم الهندسية ISSN: 1813162X 23127589 Year: 2018 Volume: 25 Issue: 4 Pages: 46-50
Publisher: Tikrit University جامعة تكريت

Loading...
Loading...
Abstract

In this work, the influence of colors of filters upon the photovoltaic panels rising temperature and electrical performance was studied under Baghdad Meteorological Condition. Basing on the energy analysis of a photovoltaic solar system and by using the photonic theory, the available energy on the PV plane system has been evaluated. Seven colored filters each with (85W) PV modules were used in this case study, to reveal the impact of colored filters upon the electrical productivity of PV panel with the variation in the temperature caused by these filters. There is themain issue of this work is to show how the performance of PV module by imposing colored filter and hence how and to how much improve it by reducing the cell temperature in hot climate. Outcomes showed that the PV technology is affected by the color filters. In other words, red filter gives light have least photons energy, and violet filter gives light have the most photons energy and green is between the two. So, red colors filter gives highest PV panel temperature comparative with others filters, while violet color filter was the lowest. PV module with the lowest temperature colored filter gives the best electrical performance than others.

في هذا العمل، تمت دراسة تأثير ألوان الفالتر على ارتفاع درجة حرارة واألداء الكهربائي لأللواح الكهروضوئية تحت الظروف الجوية لمدينة بغداد . على أساس تحليل الطاقة لنظام الطاقة الشمسية الضوئية وباستخدام النظرية الفوتونية، تم تقييم الطاقة المتاحة على نظام اللوح الكهروضوئي .تم استخدام سبعة فالتر ملونة مع كل نموذج كهروضوئي )85 واط( في هذه الحالة الدراسية، للكشف عن تأثير الفالتر الملونة على إنتاجية األلواح الكهروضوئية الكهربائية مع التغير في درجة الحرارة التي تسببها هذه الفالتر. القضية الرئيسية لهذا العمل هو إظهار كيفية أداء النموذج الكهروضوئي عن طريق فرض الفلترة الملونة وبالتالي كيف وإلى اي مدى يتم التحسين عن طريق خفض درجة حرارة الخلية في المناخ الحار .أظهرت النتائج أن التكنولوجيا الكهروضوئية تتأثر بالفالتر الملونة . وبعبارة أخرى، الفلتر األحمر يعطي ضوء له أقل طاقة فوتونية، ويمنح الفلتر البنفسجي ضوء له اعلى طاقة فوتونية واالخضر بين االثنين. لذا ، الفلتر األحمر اللون يعطي أعلى درجة حرارة للوح الكهروضوئي مقارنة مع بقية الفالتر ، بينما كان الفلتر البنفسجي اللون هو األقل. النموذج الكهروضوئي مع الفلتر الملون االقل درجة حرارة يعطي أفضل أداء كهربائي من البقية.


Article
Design And Implementation of Solar Cell System To Operate Water Dispenser
تصميم وتنفيذ نظام خلايا شمسية لتشغيل براد مياه

Author: .Ghaidaa.Kaain.Salih غيداء كائن صالح
Journal: Journal of Al-Ma'moon College مجلة كلية المأمون ISSN: 19924453 Year: 2017 Issue: 30 Pages: 174-196
Publisher: AlMamon University College كلية المامون الجامعة

Loading...
Loading...
Abstract

This research studies the application of solar energy in operating system of water dispensers. Four water dispensers are used with capacity of (20) liters each a. These dispensers worked along (eight) hours. The design calculation has been performed into two stages to get the desired results. The first stage was the theory which requires the construction of the solar cells system. In order to run this stage we used (6) solar panels with capacity of (100 w) each, (4) inverters with capacity of (1000 w & 12 v) , charging controllers , batteries and (4) containers. But this system worked along (three) hours only where later got a hard landing. The second stage is experimental design process which requires the construction of the solar system. In this stage we used (8) solar panels with capacity of (100 W), (4) inverters with capacity of (1000 w & 24 v) , charging controllers ,battery and (4) containers which gave the functioning effectively for (eight) hours and achieved the desired results of this research. The design and implementation solar cells system of this research was done in the University of Technology. In order to get the desired goal of this research, the research had discussed factors that affect the solar panels such as the output power, the temperature of the surface, the photoelectric conversion efficiency, irradiance solar and working hours.

يدرس هذا البحث تطبيق الطاقة الشمسية في انظمة تشغيل برادات المياه. استخدمت اربعة برادات مياه بسعة (20) لتر لكل واحد منها حيث عملت طيلة (8) ساعات من التشغيل .اجريت الحسابات التصميمية على مرحلتين من اجل الحصول على الاهداف المطلوبة من البحث. تضمنت المرحلة الاولى الدراسة النظرية التي تطلبت استخدام نظام خلايا شمسية تمثلت بـ (6) الواح شمسية سعة كل منها (100 واط ) ,(4) محولات بسعة (1000 واط & 12 فولت ), مسيطرات شحن , بطاريات مع (4) حاويات للعمل . لكن لم تشتغل المنظومة سوى (3) ساعات فعلية فقط بعدها حصل الهبوط الحاد. اما المرحلة الثانية فقد تضمنت الجزء التجريبي لتصميم النظام الذي اعتمد في بناءه (6) الواح شمسية سعة كل منها (100 واط ) ,(4) محولات بسعة (1000 واط & 24 فولت ), مسيطرات شحن , بطاريات مع (4) حاويات للعمل حيث امكن تشغيل المنظومة لمدة (8) ساعات فعلية ومن ثم تحقيق النتائج المطلوبة من البحث . تم تصميم وتطبيق المنظومة في الجامعة التكنولوجية .ومن اجل الحصول على الهدف المطلوب من البحث فان البحث قد ناقش العوامل المؤثرة على الالواح الشمسية مثل القدرة الخارجة , درجة حرارة السطح, كفاءة الخلايا الشمسية ,الاشعاع الشمسي و ساعات العمل .


Article
LOAD SHARING REGULATION OF A GRID-CONNECTED SOLAR PHOTOVOLTAIC SYSTEM IN KARBALA CITY

Authors: . Kassim Abdulrezak Al-Anbarri --- Ali Jafer Mahdi --- Emad Abdulreza Hameed
Journal: Journal of Engineering and Sustainable Development مجلة الهندسة والتنمية المستدامة ISSN: 25200917 Year: 2018 Volume: 22 Issue: 2 (Part-4) Pages: 168-182
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

Microgrid is an effective solution for increasing the reliability of power distribution system using renewable energy sources. In this research, a solar photovoltaic (PV) power system designed for extraction maximum power, i.e. 100kW (at standard conditions, 1000 W/m2 and 25oC) is simulated for grid utilities. For extraction maximum power, the duty ratio of a DC-DC converter is adjusting based on the specific value of maximum power point (MPP) voltage of the PV array. Thus, the DC voltage of the inverter side is kept constant to meet the grid specifications, e.g. 400V and 50Hz. The PV array is modelled by nonlinear equations which describe the effect of real irradiance levels (for Karbala city) on DC voltage. The PV power system is designed in an actual location in Karbala city for supplying a three-phase load, e.g. about 62 kW. Due to the fluctuations in solar irradiance, a load sharing between the PV power system and the grid is controlled. The load sharing is verified numerically by the Newton-Raphson method for a three-bus ring distribution system. Numerical and simulation results show the capability of the designed PV power system to share the load with grid over the year.


Article
Statistical analysis of Sunspot and total solar irradiance effects on the climate in kirkuk area for three solar cycles (22,23,24)
التحليل الاحصائي لتأثير البقع الشمسية والاشعاع الشمسي على المناخ في منطقه كركوك لثلاث دورات شمسيه (22,23,24)

Loading...
Loading...
Abstract

In this study Sunspot number(SSN) and Total solar irradiance(TSI wm^(-2)) observation were extracted from the Solar Influences Data analysis Center (SIDC) and Earth Radiation Budget Satellite (ERBS) for solar cycles 22,23 and 24 (1988-2017) and for the same cycles the parameters of climate were taken from the meteorological data recorded in Kirkuk station, which includes annual relative humidity(RH%),annual air temperature (cº)(T), annual Rainfall (mm)(p), and annual Sunshine duration(h/day)(SH).The statistical correlation between the adopted solar and climate parameters has been achieved by using Statistical program (SPSS) version (23). From this statistical analysis shows that there is a correlation between SH with both (SSN) and (TSI) less than 0.5 that is mean (SSN) and (TSI) have little effect on SH while the correlation is weak or missing between both (SSN) and solar (TSI) with RH% through the correlation coefficient values (0.05,0.032). The effect of (TSI) on the air temperature more than the impact of (SSN) but less than 0.5. The effect of (SSN) more than (TSI) on the amount of rainfall less than 0.5 according to the correlation coefficient value .this investigation shows that the climate in Kirkuk is clearly influenced by solar activity which includes SSN and TSI.

في هذه الدراسة تم رصد اعداد البقع الشمسية (SSN) والاشعاع الشمسي (TSI) في مركز تحليل بيانات التأثيرات الشمسية (SIDS) والقمر الصناعي (ERBS)للدورات الشمسية (22,23,24) للفترة (1988-2017). وبالنسبة لنفس الفترة تم اخذ بيانات الارصاد الجوية المسجلة في محطة كركوك لمعاملات المناخ والتي تتضمن(المعدل السنوي للرطوبة النسبية، المعدل السنوي لدرجة حرارة الهواء، المعدل السنوي للساقط المطري، المعدل السنوي للسطوع الشمسي) .حيث تم التحقق من الارتباط الاحصائي بين المعاملات الشمسية والمناخية باستخدام البرنامج الاحصائي (SPSS) للإصدار (23). من هذا التحليل الاحصائي تبين ان هناك ارتباط بين السطوع الشمسي مع كل من البقع الشمسية والاشعاع الشمسي اقل من 0.5 اي ان البقع الشمسية والاشعاع الشمسي يؤثر بشكل قليل على SH بينما الارتباط يكون ضعيف او معدوم بين كل من البقع الشمسية والاشعاع الشمسي مع الرطوبة النسبية من خلال قيمة معامل الارتباط (0.05,0.032). كما ان تأثير الاشعاع الشمسي على درجه حراره الهواء اكثر من تأثير البقع الشمسية ولكن بنسبه اقل من 0.5.وايظا يكون تأثير البقع الشمسية اكثر من الاشعاع الشمسي على كميه الساقط المطري بنسبه اقل من 0.5 حسب قيمة معامل الارتباط الاحصائي. يظهر هذا التحقيق ان المناخ في منطقه كركوك يتأثر بشكل قليل بالنشاط الشمسي الذي يشمل البقع الشمسية والاشعاع الشمسي.


Article
Optimum Tilt Angle of Photovoltaic Panels for Some Iraq Cities

Author: Firas Aziz Ali
Journal: Journal of University of Babylon مجلة جامعة بابل ISSN: 19920652 23128135 Year: 2018 Volume: 26 Issue: 1 Pages: 155-163
Publisher: Babylon University جامعة بابل

Loading...
Loading...
Abstract

The operation of a photovoltaic (PV) panels are influenced by its inclination angle with the horizontal surface. Thus, it must be inclined at a proper angle to raise the effectiveness of these panels. This research focuses on the computation of optimum slope angle of the PV panels in order to get the maximum incident solar radiation. Therefore, it is recommended to set the PV panels at fixed slope angle throughout the year to avoid the cost of sun tracking systems. In this research, an optimum slope angle of PV panels is investigated to get a maximum incident solar irradiance value using Bernard-Menguy-Schwartz model for some Iraq cities: Baghdad city (latitude of 33o22'N), Mosul city (latitude of 36o15'N), Zakho city (latitude of 37o10'N), and Samawah city (latitude of 31o15'N). The results showed that the optimum slope angle for these panels seems to be close to latitude of these cities.

يتأثر أداء الألواح الكهروضوئية بزاوية الميل مع المستوي الأفقي. وهكذا، يجب أن تميل الالواح الكهروضوئية بزاوية ميل مناسبة لرفع فعالية هذه الالواح. ويركز هذا البحث على حساب زاوية الميل المثالية للالواح الكهروضوئية من أجل الحصول أقصى قدر من الإشعاع الشمسي الساقط على ذلك اللوح. ولذا ينصح بتعيين زاوية ميل ثابتة للالواح الكهروضوئية خلال فترة السنة لتجنب كلفة أنظمة تعقب الشمس. في هذا البحث تم دراسة زاوية الميل المثلى للالواح الكهروضوئية للحصول على القيمة القصوى للإشعاع الشمسي الساقط باستخدام نموذج برنار- منغوي- شوارتز لبعض مدن العراق: مدينة بغداد (خط العرض 33o22'N), مدينة الموصل (خط العرض (36o15'N، مدينة زاخو (خط عرض 37o10'N), ومدينة السماوة (خط عرض 31o15'N). أظهرت النتائج أن زاوية الميل المثلى لتلك الالواح تقترب من قيمة زاوية خط العرض لتلك المدن.


Article
Characterization Performance of Monocrystalline Silicon Photovoltaic Module Using Experimentally Measured Data
دراسة توصيفية لأداء نموذج المعاملات الخمسة لوحدة الطاقة الشمسية الكهروضوئية أحادية البلورية باستخدام بيانات مقاسة تجريبياً

Authors: Emad Talib Hashim عماد طالب هاشم --- Mena Safaa Mohammed مينا صفاء محمد
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2019 Volume: 25 Issue: 10 Pages: 1-19
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Solar photovoltaic (PV) system has emerged as one of the most promising technology to generate clean energy. In this work, the performance of monocrystalline silicon photovoltaic module is studied through observing the effect of necessary parameters: solar irradiation and ambient temperature. The single diode model with series resistors is selected to find the characterization of current-voltage (I-V) and power-voltage (P-V) curves by determining the values of five parameters (I_Ph 〖,I〗_S,I_rs,R_Sh,A). This model shows a high accuracy in modeling the solar PV module under various weather conditions. The modeling is simulated via using MATLAB/Simulink software. The performance of the selected solar PV module is tested experimentally for different weather data (solar irradiance and ambient temperature) that is gathered from October 2017 to April 2018 in the city of Baghdad. The collected data is recorded for the entire months during the time which is limited between 8:00 AM and 1:00 PM. This work demonstrates that the change in a cell temperature is directly proportional with the PV module current, while it is inversely proportional with the PV module voltage. Additionally, the output power of a PV module increases with decreasing the solar module temperature. Furthermore, the Simulink block diagram is used to evaluate the influence of weather factors on the PV module temperature by connecting to the MATLAB code. The best value from the results of this work was in March when the solar irradiance was equal to 1000 W/m2 and the results were:Isc,exp=3.015, Isc,mod=3.25 , RE=7.79 and Voc,exp=19.67 ,Voc,mod=19.9 ,RE=1.1

برز نظام الطاقة الشمسية الكهروضوئية كواحدة من أكثر التقنيات الواعدة لتوليد الطاقة النظيفة. تمت دراسة أداء الوحدة الشمسية الضوئية السليكونية أحادية البلورية في هذا العمل من خلال ملاحظة تأثير معاملين مهمين هما: إشعاع الشمسي ودرجة حرارة المحيط. يتم اختيار نموذج الصمام الثنائي مع المقاومات المربوطة بالتسلسل لإيجاد توصيف منحنيات الجهد-التيار و الجهد-الطاقة من خلال تحديد قيم معايير الوحدة الشمسية الخمسة. هذا النموذج يبين دقة عالية في نمذجة وحدة الطاقة الشمسية الكهروضوئية تحت ظروف الطقس المختلفة. يتم محاكاة النمذجة باستخدام برنامج الماتلاب-السميولنك. تم اختبار أداء الوحدة الكهروضوئية الشمسية تجريبيًا في مدى محدد من قيم الإشعاع الشمسي ودرجة الحرارة المحيطة والتي يتم جمعها من أكتوبر 2017 إلى أبريل 2018 في مدينة بغداد. تم تدوين البيانات التي جمعها للأشهر المختارة خلال الفترة الزمنية المحددة بين 8:00 صباحًا الى 1:00 مساءً. يوضح هذا العمل أن التغيير في درجة حرارة وحدة الطاقة الشمسية يتناسب طرديًا مع قيمة تيار وحدة الطاقة الكهروضوئية ، بينما يتناسب عكسياً مع قيمة وحدة الجهد الكهربائي. بالإضافة إلى ذلك ، تزداد الطاقة المنتجة من الوحدة الكهروضوئية مع انخفاض درجة حرارة الوحدة الشمسية. علاوة على ذلك, يتم استخدام مخطط التصميم للسميولنك لتقييم تأثير العوامل الجوية على درجة حرارة الوحدة الكهروضوئية عن طريق الربط ببرنامج الماتلاب. افضل نتيجة تم الحصول عليها من النتائج المذكورة في الدراسة في شهر اذار حيث الاشعاع الشمسي 1000 واط/م2هي : Isc,exp= 3.015, Isc,mod=3.25 , RE=7.79&Voc,exp=19.67 , Voc,mod= 19.9 , RE=1.1

Listing 1 - 7 of 7
Sort by
Narrow your search

Resource type

article (7)


Language

English (7)


Year
From To Submit

2019 (2)

2018 (3)

2017 (2)