research centers


Search results: Found 19

Listing 1 - 10 of 19 << page
of 2
>>
Sort by

Article
Induced Buoyancy In Inclined Solar Chimney For Natural Ventilation

Authors: Zinah Jaber Khalaf --- Jalal M. Jalil
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2011 Volume: 29 Issue: 2 Pages: 183-194
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

A 2-D plane, steady, incompressible, turbulent flow field developed by naturalconvection inside inclined solar chimney at different inclination angles rangingfrom (30o to 90o), heat fluxes from (100 W/m² to 500 W/m²) and chimneythickness(0.1, 0.2 m) chimney is investigated numerically. It is found thatmaximum air temperature and maximum volume flow rate was 101.7oC, 306.3m³/h respectively at heat flux,500 W/m2; inclination angle; 90o and chimneythickness; 0.2m. Maximum outlet air velocity was 0.488 m/s at chimneythickness; 0.1m, heat flux; 500 W/m2; and inclination angle; 90o. Increase in heatflux, inclination angle and chimney thickness leads to increasing of volume flowrate. Increase in chimney cross-sectional area leads to decrease in air velocity andincrease in volume flow rate


Article
Numerical Simulation of the Collector Angle Effect on the Performance of the Solar Chimney Power Plant
نمذجة رقمية لتاثير زاوية المجمع على سلوك الجريان في منظومة مدخنة شمسية لتوليد القدرة

Authors: Abbas J. Jubear عباس جاسم جبير --- Waheeds S. Mohammad وحيد شاتي محمد --- Arkan k. Al-Taaie اركان خلخال حسين
Journal: Al-Khwarizmi Engineering Journal مجلة الخوارزمي الهندسية ISSN: 18181171 23120789 Year: 2016 Volume: 12 Issue: 2 Pages: 79-89
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Sloped solar chimney system is a solar chimney power plant with a sloped collector. Practically, the sloped collector can function as a chimney, then the chimney height can be reduced and the construction cost would be reduced.The continuity, Naver-stockes, energy and radiation transfer equations have been solved and carried out by Fluent software. The governing equations are solved for incompressible, 3-D, steady, turbulent standard model with Boussiuesq approximation to develop for the sloped solar chimney system in this study and evaluate the performance of solar chimney power plant in Baghdad city of Iraq numerically by Fluent (14) software with orking conditions such as solar radiation intensity (300,450,600,750 and 900 W/m2), and collector which angle (0°, 15° and 30°).The results show that the change of collector angle has considerable effects on the performance of the system.The velocity increases when the collector angle increases and reach to the maximize value at a collector angle (30°). The temperature increase with the collector tile angle increase at solar intensity times (7:30,8:15,9,10 AM) but decrease at 12:30 PM) corresponding to solar intensitIes. The study show that Iraqi wather are suitable for this system.

ان نظام المدخنة الشمسية المائل عبارة عن مدخنة قدرة شمسية يكون فيها وضع المجمع الشمسي مائلا بزاوية والذي يمكن وصفه دالة للمدخنة,حيث بالامكان تخفيض كلفة انشاء المدخنة وذلك بسبب التخفيض الذي سوف يحصل في ارتفاع المدخنة.تم حل معادلات الاستمرارية والزخم والطاقة والاشعاع الشمسي باستخدام برنامج Fluent (14).في هذه الدراسة تم اختبار اداء المدخنة الشمسية المائلة خلال جريان لاانضغاطي ,ثلاثي الابعاد, مستقر واضطرابي حيث تم الاستعانة بالموديل الاضطرابي k-ε وذاك لحساب اداء المدخنة الشمسية تحليليا في اجواء بغداد- العراق,حيث كانت ابعاد المدخنة الشمسية الارتفاع 6 م ,قطر المجمع 6م,قطر المدخنة 0.3 م وارتفاع مدخل المجمع 0.1 م وذلك عند ظروف اختبار مختلفة ,شدة الاشعاع الشمسي (300 و 450 و 600 و 750 و900 ) واط/م2 وعند زويا ميل مختلفة للمجمع (30°, 15°, 0°) من ابرز النتائج التي توصل لها البحث هو التاثير الكبير لتغير زاوية المجمع الشمسي على اداء المدخنة الشمسية.حيث نلاحظ ازدياد سرعة الهواء داخل المدخنة بزيادة زاوية ميلان المجمع حث تصل الى اقصى قيمه عند زاوية °30 ,تم التوصل كذلك ان درجات الحرارة تزداد بزيادة زاوية المجمع الشمسي في الاوقات (7:30,8:15,9,10 ق ظ) والمناظرة لشدة الاشعاع الشمسي وتقل عند (12:30) ب ظ. بينت هذه الدراسة ايضا ان اجواء العراق ملائمة لهذا النوع من الانظمة.


Article
Combined Solar Chimney Power Plant and Solar Still

Author: Salman H. Hammadi سلمان هادي حمادي
Journal: Basrah Journal for Engineering Science مجلة البصرة للعلوم الهندسية ISSN: Print: 18146120; Online: 23118385 Year: 2016 Volume: 16 Issue: 2 Pages: 100-107
Publisher: Basrah University جامعة البصرة

Loading...
Loading...
Abstract

This study presents solar chimney power plantintegrated with seawater desalination system. A simplemathematical model is based on the conservation of massand energy. The results show that the integrated system ofsolar chimney power plant and solar still can achievesimultaneously. The analysis is performed for bothsummer and winter at latitude 30oN. It’s noted that thewater layer thickness is of a significant effect on the freshwater productivity while the dimensions of solar chimneyand the solar collector are of a minor effect. Theproductivity of fresh water and output power for summerare the highest. The present work is compared withexperimental data of the other work and showed a goodagreement.


Article
Basement Kind Effects on Air Temperature of a Solar Chimney in Baghdad - Iraq Weather
تأثير نوع القاعدة على درجات حرارة مدخنة هوائية في أجواء مدينة بغداد- العراق

Author: Miqdam Tariq Chaichan مقدام طارق جيجان
Journal: Al-Khwarizmi Engineering Journal مجلة الخوارزمي الهندسية ISSN: 18181171 23120789 Year: 2011 Volume: 7 Issue: 1 Pages: 30-38
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

A solar updraft tower power plant (solar tower) is a solar thermal power plant that utilizes a combination of solar
air collector and central updraft tube to generate an induced convective flow which drives pressure staged turbines to generate electricity.

This paper presents practical results of a prototype of a solar chimney with thermal mass, where the glass surface is replaced by transparence plastic cover. The study focused on chimney's basements kind effect on collected air temperatures. Three basements were used: concrete, black concrete and black pebbles basements. The study was conducted in Baghdad from August to November 2009.
The results show that the best chimney efficiency attained was 49.7% for pebbles base. The highest collected air temperature reached was 49&#186;C when using the black pebbles basement also.also, the maximum basement temperature measured was 59&#186;C for black pebbles. High increaments in collected air temperatures were achieved in comparison with the ambient air temperatures for the three basement kinds. The highest temperature difference reached was 22&#186;C with the pebble ground.

تستخدم مدخنة الهواء أو البرج الشمسي تركيبة من مجمعات الهواء الشمسية وأنبوب سحب مركزي لتوليد تدفق هواء مسخن شمسيا" مستحث بالحمل، والذي يمكنة تحريك توربينات متعددة المراحل لتوليد الكهرباء.الهدف من هذا البحث هو تقديم نتائج عملية لنموذج مدخنة شمسية ذو كتلة حرارية، إذ تم استبدال السطح الزجاجي بغطاء بلاستيكي شفاف، تركزت الدراسة على تأثير نوع قاعدة المدخنة على درجات حرارة الهواء، ولقد استخدمت ثلاثة أنواع من القواعد، قاعدة كونكريتية، قاعدة كونكريتية سوداءاللون وقاعدة من الحصى الاسود اللون، وتمت الدراسة في أجواء بغداد من شهر أيلول لغاية نوفمبر 2009.تبين الدراسة أن أفضل كفاءة للمدخنة وأعلى درجة حرارة تم الوصول لها كانت 49.7% عند استخدام قاعدة من الحصى الأسود. وأعلى درجة حرارة للهواء المجمع أمكن الوصول لها كانت 49ºC باستخدام قاعدة الحصى الأسود أيضا، كما كانت أقصى درجة حرارة قيست لهذة القاعدة هي 59ºC، لقد تم الوصول لزيادة كبيرة في درجات حرارة الهواء المجمع مقارنة مع درجات حرارة الهواء الجوي للقواعد الثلاثة المدروسة، وأعلى فرق في درجات الحرارة أمكن الوصول له كان 22ºC بأرضية من الحصى الأسود.


Article
COMPARISON BETWEEN SIMULATED AND CALCULATED POWER OF THE SOLAR CHIMNEY WITH BLACK CONCRETE BASE USING ANSYS PROGRAM
مقارنة بين القدرة النظرية والمحسوبة لمدخنة شمسية ذات قاعدة كونكريتية سوداء بأستخدام برنامج ANSYS

Loading...
Loading...
Abstract

A solar chimney has been analyzed by solving its governing equations and compare with the simulated results. The solar absorbent of the chimney is selected as a black painted concrete, which is useful as an energy saver at night. The numerical simulation using ANSYS, based on solving the governing equations with suitable assumptions and boundary conditions for many variables such as the collector area, the chimney height, the ambient temperature, and the exit area of the chimney. The results shows that the chimney height and base area are very important parameters for improving the gained power, and it is also important to choose the region with suitable mean ambient temperature. And economically there are limitations to collector and chimney sizes to get suitable profit output power and any increment in system size becomes a small percentage increment in profit output power. The results compared with some experimental data from other results researchers and there is a good agreement between simulated and calculated results

تم تحليل المدخنة الشمسية عن طريق حل المعادلات الحاكمة ومقارنة النتائج مع نتائج المحاكاة. إن اللوح الماص للمدخنة الشمسية تم اختياره من الكونكريت المطلي باللون الاسود والذي يعتبر مفيدا لخزن الحرارة ليلا. إن المحاكاة العددية باستخدام برنامج ANSYS 11.0 تم بناءه على حل المعادلات الحاكمة مع الفرضيات والشروط الحدية المناسبة لعدة متغيرات مثل مساحة المجمع ارتفاع المدخنة ودرجة حرارة المحيط و مساحة مخرج المدخنة. أظهرت النتائج أن ارتفاع المدخنة ومساحة المجمع هي عوامل مهمة جدا لتحسين القدرة الناتجة، وكذلك من المهم اختيار المنطقة بمعدل درجة حرارة محيط مناسبة.وان هناك محددات اقتصادية لحجم المدخنة والمجمع الشمسي للحصول على قدرة خارجة مناسبة وان أي زيادة في الحجم يقلل من نسبة الزيادة في القدرة الخارجة المفيدة. ناظرت النتائج في هذا البحث مع بعض النتائج التجريبية لباحثين آخرين وان هناك تقاربا جيدا بين نتائج الحسابات والمحاكاة .


Article
Numerical Study of a Solar Chimney Power Plant
دراسة عددیة لمدخنة شمسیة لتولید الطاقة

Authors: Rafah A. Najim --- Jalal M. Jalil
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2012 Volume: 30 Issue: 15 Pages: 2597-2608
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

Axi-symmetric, steady, incompressible, turbulent flow field developed by natural convection inside power plant solar chimney is investigated numerically using finite volume method. Navier-Stockes with energy equation is solved to achieve velocity components and temperature distribution inside solar chimney. To complete the thermal analysis, conduction through upper glass wall, chimney concrete wall and floor ground were investigated to calculate temperature distribution through theses walls. A standard turbulence model associated with lawss of the wall along solid boundaries was used. Special arrangement for mesh was used to deal with complicated shape of the domain. The main studied parameters are solar collector diameter, kinds of ground, periphery heights and solar intensity radiation. This study was compared with previous available experimental study and there is acceptable agreement. The performance of the solar chimney was examined through maximum air velocity in the tower inlet and maximum temperature in the ground floor. The final optimization parameters are defined within studied ranges.

درس البحث الحالي مدخنة شمسية لتوليد الطاقة الكهربائية وذلك باستخدام حقل جريان متماثل، لا انظغاطي واضطرابي لتيارات الحمل الطبيعي وحلها عدديا باستخدام طريقة العناصر المحددة لحل معادلة Navier-Stokes equation ومعادلات الطاقة وذلك لحساب مكونات السرعة وتوزيع درجة الحرارة. لانجاز التحليل الحراري تم حساب التوصيل خلال الجدار العلوي الزجاجي ، جدار المدخنة الاسمنتي والارضية الممتصة للمجمع الشمسي ولقد تم الاستعانة بالموديل الاضطرابي (k ) الذي ترافق حسابه مع قوانين الجدار على طول الحدود الصلبة، مع الاخذ بالاعتبار تدابير خاصة للتعامل مع الشكل المعقد للحقل. ولاختبار صلاحية الدراسة فقد تم مقارنتها مع دراسة عملية سابقة ولنفس الظروف المحيطة، وكان هناك توافق مقبول ما بينهما. لقد اختبر اداء المدخنة الشمسية خلال اعلى سرعة للهواءفي مدخل المدخنة و اعلى درجة حرارة في الارضية ولقد جرى تحديد العوامل المثالية ضمن المدى المدروس.


Article
EFFECT OF SPIRAL RIB ON SOLAR CHIMNEY COLLECTOR PERFORMANCE

Authors: Farhan Lafta Rashid --- Salah Noori Alnomani
Journal: Al-Qadisiyah Journal for Engineering Sciences مجلة القادسية للعلوم الهندسية ISSN: 19984456 Year: 2016 Volume: 9 Issue: 3 Pages: 349-359
Publisher: Al-Qadisiyah University جامعة القادسية

Loading...
Loading...
Abstract

AbstractThe increased demand for renewable energy calls for increased developments to thetechniques of production for such energy. This paper presents a numerical study of conicalcollector solar chimney with specific dimensions. A glass spiral of square cross section wasfitted to the collector to investigate its effects on the velocity distribution of air. Results showthat the spiral enhances velocity distribution by (11.57% and 12.82%) corresponding to theinlet air velocity of (Re=99945 and 499729) respectively. This enhancement will reflect tothe instantaneous electric power which can be produced by such instrument. Theinvestigation was carried out using CFD program FlUENT14.5, K-ɛ model.

الخلاصة ازدياد الطلب على الطاقة المتجددة يدعو الى زيادة التطوير في تقنيات الانتاج لهذه الطاقة. في البحث الحالي تمت دراسة عددية لمجمع مدخنة شمسية بشكل مخروطي وبأبعاد معينة.وضع لولب مصنوع من الزجاج وبمقطع عرضي مربع بتماس مع الجدار الداخلي للمجمع لبحث التأثير على توزيع سرعة الهواء داخل المجمع.تم استحصال النتائج النظرية وقد بينت ان استخدام اللولب يزيد من توزيع السرعة بمقدار(11,57% و 12,82%) لسرع دخول الهواء للمجمع وبقيم رقم رينولد(99945 و 499729) بالمقارنة مع حالة عدم استخدام اللولب وهذه الزيادة سوف تنعكس على زيادة القدرة المنتجة في التوربين المدار بتأثير حركة الهواء الى الاعلى وقد استخدم برنامج فلونت 14.5 لكافة الحسابات باستخدام نموذج K-ɛ


Article
Experimental and Numerical Study of Collector Geometry Effect on Solar Chimney Performance
دراسة عملية وعددية لتأثير شكل المجمع على إداء المدخنة الشمسية

Loading...
Loading...
Abstract

There have been many advances in the solar chimney power plant since 1930 and the first pilot work was built in Spain (Manzanares) that produced 50 KW. The solar chimney power plant is considered of a clean power generation that needs to be investigated to enhance the performance by studying the effect of changing the area of passage of air to enhance the velocity towards the chimney to maximize design velocity. In this experimental and numerical study, the reduction area of solar collector was investigated. The reduction area that mean changing the height of glass cover from the absorbing plate (h1=3.8cm, h2=2.6cm and h3=1.28cm). The numerical study was performed using ANSYS Fluent software package (version 14.0) to solve governing equations. The aim of this work was to study the effect of change the height of reduction area to the design velocity (velocity move the blade of turbine at inlet in the chimney). The results showed that the third height (h3=1.28cm) gives the best result because when decreasing the height between the glass cover and absorbing plate, the area between them decreased and the design velocity increased then the efficiency of solar chimney model was increased.

تطورت محطات التوليد الكهربائية بوساطة المدخنه الشمسيه منذ سنه 1930م .محطة الطاقة الشمسية تعد مولدا للطاقة النظيفة. الدراسة الحالية هي عملية وعددية عن منطقة الانخفاض في المجمع الشمسي.منطقة الانخفاض تعني تغير الارتفاع بين سقف المجمع الشمسي وبين صفيحة الامتصاص (قاع المجمع الشمسي) التي تكون ذات بعد معين عن مركز المجمع وهذا البعد يعتمد على حجم النوذج المستعمل.دُرِسٓ تغير ارتفاعات منطقة الانخفاض عمليا وعدديا حيث تم استخدم ثلاثة ارتفاعات ( 3.8، 2.6، 1.28) سم على التوالي.الهدف من هذا البحث هو دراسه تأثير ارتفاعات منطقة الانخفاض على السرعه التصميمية (السرع الذي تقوم بتحريك ريش التوربين الموجودة عند مدخل المدخنة). بينت النتائج ان استخدام الارتفاع 1.28سم هوالافضل والسبب في ذاك عند تقليل الارتفاع بين السقف والقاع تعني تقليل من مساحه الجريان داخل المجمع الشمسي مما يؤدي الى زياده في سرعة الجريان تؤدي الى زياده كفاءة المدخنة الشمسية.


Article
Experimental and Numerical Study of Closed Loop Solar Chimney Assisted with PCM and CFM as Thermal Energy Storage Collector

Authors: Talib K. Murtadha --- Hussien M. Salih --- Ali D. Salman
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2016 Volume: 34 Issue: 13 Part (A) Engineering Pages: 2450-2463
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

In this work, a test room was built in Baghdad city, with selective dimensions, while the solar chimneys (SC) where designed with aspect ratio (ar) bigger than 12 and setup to the oriented wall to the south. Collector of SC consist of paraffin wax as a phase change material (PCM) and supported by copper foam matrix (CFM), to enhance the combined of thermal energy storage material box (TESMB). Double transparent acrylic sheets covered the collector from outside. TESB supported by array of evacuated tubular collector with thermosyphon to sincere heat storage in the TESB. Results of experimental work that achieved in 25 January and 26 February refer to effectiveness using TESM in closed loop SC in day time and its effect cover the night time also. The heating system of test room is arrived to the biggest room temperature after sun set, at that moment the difference between indoor and outdoor approximately 15oC, and room temperature value still bigger after five hours from sun- set with a different in temperature by approximately 8 oC. Numerical solution done by employing CFD with solution the PDE’s that present continuity, momentum, energy equations, by using the FVM with algebraic forms of turbulent viscosity and diffusion coefficient and employing turbulent standard (k-ε)model. The comparison between numerical and experimental results indicated that the heat transfer inside test room is dominate by condition, also results shows acceptable convergence in velocity and temperature profile, while the experimental results for air flow inside SC gap appears the turbulent behavior in most duration time.


Article
EXPERIMENTAL STUDY FOR GROUND TYPE EFFECT ON SOLAR CHIMNEY POWER PLANT

Authors: Mohammed H. Abbood --- Mohammed R. Abbas
Journal: KUFA JOURNAL OF ENGINEERING مجلة الكوفة الهندسية ISSN: 25230018 Year: 2018 Volume: 9 Issue: 2 Pages: 103-113
Publisher: University of Kufa جامعة الكوفة

Loading...
Loading...
Abstract

Solar chimney power plant is a technology capable to generate electric energy through a wind turbine using the solar radiation as energy source; nevertheless, one of the objectives pursued since its invention is to achieve energy generation during day and night. The ground under the power plant plays an important role on the energy balance and heat transfer, due to its natural behavior as a heat storage system. An experimental model was designed in Holley Kerbala city (Iraq), which consisted of a 3m collector radius with 8ᴼ collector inclination angle and a 6m height of chimney been constructed and collector periphery opening height 3cm. Three kinds of grounds was studied in this work: sand, mixed from sand and pebble and the third is black pebble. The results show that the highest airflow temperature inside the chimney reached was 66.8Co when using the black pebbles basement. The maximum basement temperature measured was 81.6Co for the mixed basement. Also, the highest temperature difference reached was 23.2Co for the same ground that have good performance during day light compared with pebble basement that have more energy saving in night.

Listing 1 - 10 of 19 << page
of 2
>>
Sort by
Narrow your search

Resource type

article (19)


Language

English (14)

Arabic and English (5)


Year
From To Submit

2018 (3)

2016 (6)

2015 (1)

2014 (2)

2013 (1)

More...