An Investigation into Thermal Performance of Mist Water System and The Related Consumption Energy
دراسة الاداء الحراري لمنظومة رذاذ الماء و تاثيرها في استهلاك الطاقة

Authors: Najim Abid Jassim نجم عبد جاسم --- Firas Adel Abdulkareem Haris فراس عادل عبد الكريم حارس
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2014 Volume: 20 Issue: 9 Pages: 108-119
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Experimental tests were conducted to investigate the thermal performance (cooling effect) of water mist system consisting of 5μm volume median diameter droplets in reducing the heat gain entering a room through the roof and the west wall by reducing the outside surface temperature due to the evaporative cooling effect during the hot dry summer of Baghdad/Iraq. The test period was Fifty one days during the months May, June, and July 2012. The single test day consists of 16 test hours starting from 8:00 am to 12:00 pm. The results showed a reduction range of 1.71 to 15.5℃ of the roof outside surface temperature and 21.3 to 76.6% reduction in the daily heat flux entering the room through the roof compared with the case of not using water mist system. Also the results show a reduction range of 1.3 to 18.8℃ in the wall outside surface temperature. Finally numerical simulation with ANSYS-FLUENT.14 was conducted to compare its results with the experimental results of the roof and wall tests.

تم اجراء اختبارات عملية من اجل دراسة الاداء الحراري لمنظومة رذاذ الماء بقطيرات بمعدل قطر 5 مايكرون , في تقليل الحمل الحراري الداخل الى غرفة من خلال السقف و الجدار الغربي لها بخفض درجة حرارة السطح الخارجي نتيجة التاثير التبريدي التبخيري خلال فترة الصيف الحار و الجاف في بغداد/العراق. فترة الاختبارات كانت لمدة واحد و خمسون يوما خلال اشهر ايار و حزيران و تموز من العام 2012 , و تضمن يوم الاختبار 16 ساعة من الاختبارات ابتداءا من الساعة الثامنة صباحا و حتى الساعة الثانية عشرة ليلا. اظهرت النتائج العملية هبوط بمقدار 1.71 الى 15.5 درجة مئوية في حرارة السطح العلوي للسقف, و هبوطا بمقدار 21.3 الى 76.6 % من الحمل الحراري اليومي الداخل للغرفة من السقف. كذلك و بالنسبة للجدار الغربي فقد اظهرت النتائج هبوطا بمقدار 1.3 الى 18.8 درجة مئوية في حرارة السطح الخارجي للجدار. اخيرا تم استعمال برنامج المحاكاة الهندسي ANSYS-FLUENT.14 من اجل مقارنة النتائج العملية للسقف و الجدار مع النتائج النظرية المتولدة من هذا البرنامج.


Article
Performance Enhancement of an Air Cooled Air Conditioner with Evaporative Water Mist Pre-cooling
تحسين الاداء الحراري لمكيف هواء مكثفه مبرد بالهواء مع تبريد مسبق بمرذاذ مائي تبخيري

Author: Najim Abid Jassim نجم عبد جاسم
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2017 Volume: 23 Issue: 1 Pages: 48-62
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The present paper deals with experimental investigation of the performance of air cooled split air conditioner, with evaporative water mist pre cooling to increase the cooling capacity and reduce the consumption power under hot and dry climate. This investigation considers how the performance can be enhanced by using water mist to pre-cool ambient air entering the condensers by adiabatic cooling process which depends on the ambient air wet bulb temperature; as well the condensing temperature and condensing pressure will be decreased accordingly. So the cooling capacity would be increased and consumption power would be decreased, consequently the energy ratio, EER would be improved. The performance of air cooled air conditioner with water mist pre cooling; ECAC was compared to the performance of air cooled air conditioner, ACAC which tested under the same ambient condition that is ranged from 25oC to 52oC. Test results show that ECAC operating at EER of 10.5 BTV/W. The ECAC had an EER of 47 % higher than that of ACAC under the same and most serve hot and dry condition of 52oC and 10% relative humidity.

يتعامل البحث الحالي مع التحري التجريبي للاداء الحراري لمكيف هواء نوع منفصل مكثفه مبرد بالهواء مع مرذاذ مائي في عملية تبريد اولي للهواء الخارجي الداخل للمكثف لغرض زيادة السعة التبريدية وخفض الطاقة المستهلكة في جو حار وجاف. يوضح هذا التحقق التجريبي كيف يمكن تحسين الاداء الحراري عند استعمال مرذاذ مائي كمبرد اولي لخفض درجة حرارة الهواء الخارجي قبل الدخول الى المكثف بعملية تبريد اديباتي تعتمد على درجة حرارة البصلة الرطبة للهواء كذلك بموجبها يتم خفض درجة حرارة وضغط التكثيف وفقا لذلك. لذا ستزداد السعة التبريدية وستنخفض الطاقة المستهلاكة وبالتالي ستتحسن نسبة كفاءة الطاقة. تم مقارنة الاداء الحراري لمكيف هواء مكثفه مبرد بالهواء مع مرذاذ مائي مع الاداء الحراري لمكيف الهواء مكثفه مبرد بالهواء ACAC والتي اختبرت في نفس ظروف الجو الخارجي عند درجات حرارة هواء خارجي مداها بين 25 oم و 52 oم. بينت نتائج الاختبار عند الظروف الاساسية بان ECAC تعمل بنسبة كفاءة طاقة EER مقدارها 10.5. ان نسبة كفاءة الطاقة EER لمكيف الهواء ECAC في ظروف جو سائدة حارة وجافة عند درجة حرار 52 oم ورطوبة نسبية 10% اعلى بمقدار 47 % من مكيف الهواء ذو مكثف مبرد بالهواء في نفس الظروف.