research centers


Search results: Found 9

Listing 1 - 9 of 9
Sort by

Article
Behavior of Steel Plate Girders with Web Openings Loaded in Shear
تصرف العوارض اللوحیة الفولاذیة ذات الوترات المثقوبة المحملة بقوى القص

Authors: May J. Hamoodi --- Marwa S. Abdul Gabar
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2013 Volume: 31 Issue: 15 Part (A) Engineering Pages: 2982-2996
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

The structural behavior of three steel plate girders under shear is studied. The firstone is the reference plate girder (G) which is prepared without web openings, and thesecond one (GO) is fabricated to contain circular opening at the center of each web panel,the diameter of the opening is 60% of the web depth, while the third plate girder (GOR)is with reinforced strip welded around the circular web openings. The aspect ratio of thepanels is one and they all have the same dimensions. The experimental results obtainedfrom second and third plate girders have been compared with those obtained from thereference plate girder. The comparison indicates that the reduction in the ultimate shearload for plate girder with web opening is 51% and for the plate girder with reinforcedweb opening is 35%. Also through the experimental results, new formulas are presentedto predict the ultimate shear load of perforated steel girders with large openings.A nonlinear finite element analysis is carried out for the tested plate girders using thepackage software program (ANSYS V.11). The analytical results contain the ultimateshear capacity and Von Mises stress distribution. The results of finite element models arecompared with results of experimental tests. The difference in ultimate shear load was10%, 9% and 1.5% for plate girders GO, GOR and G, respectively. Also a parametricstudy with varying size of the reinforcement around the web openings is performed byusing the ANSYS program, and it is found that the thickness of the reinforcement striphas higher effect than its width on the ultimate shear capacity of perforated plate girder.


Article
TORISIONAL BEHAIVORE OF REACTIVE POWDER CONCRETE T-BEAM WITH WEB OPENING
سلوك اللي للعتبات ذات شكل T وذات خرسانة المساحيق الفعالة والحاوية على فتحات في الجذع

Authors: Ali Sabah Alamli --- Hayder Abdulameer Mehdi --- Reem Hatem Ahmed
Journal: Journal of Engineering and Sustainable Development مجلة الهندسة والتنمية المستدامة ISSN: 25200917 Year: 2017 Volume: 21 Issue: 3 Pages: 72-86
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

Ten T section reinforced concrete beams by use Reactive Powder Concrete (RPC) beams with square and circular web perforation tested under pure torsion . The geometry and main reinforcement of all specimens are same. The main parameters taking into account in present paper are circular opening size, location of openings and number of openings. The torque caused the ultimate crack was recorded, and the angle of twist generated from these torques is calculated. Test results indicate that, torque that causes failure (ultimate) is affected by opening size, opening locations, opening numbers, the presence of web cut – outs reduces ultimate torque capacity of section, such that the increase in web opening size reduces the ultimate torque, when the web openings increase that leads to reduction in the torque capacity، the opening eccentricity makes no uniformity of shear stress distribution through web and leads to reduce the torque capacity. Then, angle of twist depends on the opening location at crack or ultimate stages, the twisted angle depends on torque magnitude because of beam span, shear modulus and geometry of T sections which are the same and the cracks start from support and then take a spiral shape around the beams up to flange so the number of cracks increases as the presence of openings.

عشر عتبات من خرسانة المساحيق الفعالة المسلحة ذات مقطع T حاوية على فتحات مربعة ودائرية فحصت تحت تأثير عزم لي صافي . الشكل و التسليح هو نفسه لكل النماذج . المتغيرات الرئيسية التي اعتمدت في هذا البحث هي حجم الفتحات الدائرية, موقع الفتحات و عدد الفتحات . عزم اللي الذي سبب التشقق النهائي تم تسجيله وكذلك زاوية اللي قد تم حسابها ايضاً. النتائج بينت أن عزم اللي الذي الفشل النهائي قد تأثر بحجم وموقع وعدد الفتحات، فوجود الفتحات في الجذع أدى الى تقليل مقاومة المقطع لعزم اللي النهائي، وكذلك زيادة حجم الفتحات يقلل من مقاومة عزم اللي, كما اظهرت زيادة الفتحات الى الحد من قدرة عزم اللي، إن الفتحات تعمل على عدم توحيد توزيع اجهادات القص خلال الجذع (WEB) ويؤدي الى التقليل من قدرة عزم اللي (الدوران) , وكذلك زاوية الألتواء تعتمد على موقع الفتحات عند مرحلة اللي الابتدائي او النهائي , تتأثر زاوية الالتواء بمقدار عزم اللي المسلط وعزم الجسائة والقصور الذاتي للمقطع وذلك لعدة اسباب منها طول العتبة ,معامل القص وشكل مقطع العتبة. إن التشققات تبدأ من المساند وتأخذ شكل حلزوني حول العتبة لتصل الى الجناح حيث تبلغ الشقوق ذروتها بوجود الفتحات.

Keywords

Torque --- cracks --- RPC --- Web Opening --- T Section.


Article
Tests of Composite Beams with Web Openings

Authors: May J. Hamoodi --- Waleed Kh. Hadi
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2011 Volume: 29 Issue: 10 Pages: 2073-2086
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

The aim of this study is to investigate experimentally the structuralbehavior of simply supported composite beams, in which a concrete slab is connected together with a steel I-beam by means of headed stud shearconnectors under the presence of web openings. Six composite beams withconstant degree of interaction were tested under central concentrated static load. One of the beams is constructed without web opening while the others contain various number, location and shape of openings. Deflection at midspan and at the ends of each opening were observed versus load. The experimental results show that the web openings decrease the strength of composite beams in the range of 19% to 24% for the tested specimens. Distinctive effects for the location, number and shape of openings took place after initiation of section yielding. Different patterns of cracks at concrete slab were observed.


Article
Improving the Strength of Steel Perforated Plate Girders Loaded in Shear Using CFRP laminates
تحسين مقاومة العوارض اللوحية الفولاذية المثقبة المحملة بالقص بأستخدام صفائح ألياف الكاربون البوليمرية المسلحة

Authors: May J. Hamoodi --- Waeel Sh.Abdul-Sahib --- Ihsan K.Abed
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2015 Volume: 33 Issue: 9 Part (A) Engineering Pages: 2119-2129
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

The structural behavior of perforated composite web plate girders under shear loading is studied. Five steel plate girders have been tested. Two of them are reference girders, not perforated and perforated. The perforated webs in the three other girders are strengthened with carbon fiber reinforced polymer (CFRP) laminates in different patterns. The diameter of the central circle opening is 300 mm, where is 60% of the web depth. It is found from the experimental work that the ultimate shear load for the perforated composite web plate girder is higher than the reference perforated girder in a range of 100% to 134% depending on the orientation of the fiber in CFRP laminates. Through the experimental results, new formulas are presented to predict the ultimate shear load of perforated strengthened steel girders by CFRP laminates. A nonlinear finite element analysis is carried out for the tested plate girders using the package software program (ANSYS V.14.5). The analytical results contain the distribution of VonMises stresses, which is useful to have a better understanding to the results obtained from the experimental tests.

في هذا البحث يدرس السلوك الأنشائي للعوارض اللوحية المثقبة الوترة والمدعمة تحت أحمال القص. خمسة عوارض لوحية فولاذية تم أختبارها. أثنان منها عوارض مرجعية, غير مثقبة ومثقبة.الوترات المثقبة في العوارض الثلاثة الأخرى تقوى بصفائح ألياف الكاربون البوليمرية المسلحة بعدة طرق. قطر الفتحة الدائرية في الوترة هو 300mm اي مايساوي 60% من عمق الوترة. من التجارب العملية وجد أن الحمل الأقصى لقوى القص للعارضة اللوحية المثقبة والمدعمة الوترة أعلى من العارضة المثقبة المرجعية بمعدل من 100% الى 134% بالأعتماد على أتجاه الألياف في صفائح ألياف الكاربون. تم أستنتاج من خلال النتائج العملية معادلات جديدة لمعرفة الحمل الأقصى لقوى القص للعوارض الفولاذية المثقبة والمقواة بصفائح الياف الكاربون.تم أستعمال التحليل اللاخطي بواسطة العناصر المحددة للعوارض اللوحية المفحوصة بأستخدام البرنامج الجاهز ANSYS v.14.5 .النتائج التحليلية تتضمن ق توزيع الأجهادات Von Mises التي كانت مفيدة في فهم افضل للنتائج المستحصلة من الجانب العملي.


Article
The Effect of Web Opening in the Shear Span on the Ultimate load of RC Deep Beams

Authors: Kun Ye --- Yousif Jabbar Lafta
Journal: Journal of Basrah Researches (Sciences) مجلة ابحاث البصرة ( العلميات) ISSN: 18172695 Year: 2017 Volume: 43 Issue: 2A Pages: 30-43
Publisher: Basrah University جامعة البصرة

Loading...
Loading...
Abstract

Deep beams with rectangular (R) and T- cross sections that have web openings are widely used in concrete structural field for servicing purposes. This situation should be treated with special care depending on the type of the load subjected and the location of the opening. This study is aimed to investigate the ultimate load; carrying capacity of indirectly loaded deep reinforced concrete (RC) beams through an experimental and analytical program. The experimental work has two parts of specimens, where the six deep beams have ratio of shear span- to- effective depth (a/d) is 1.0 have been consider. The first part consists of two deep beams with rectangular and T- cross sections, which formed without web opening, with vertical web reinforcement. The second part consists of four deep rectangular and T-beam cross sections in which, all beams have openings in the shear span, with deferent reinforcement arrangements. The behavior of deep beams was observed, cracking and ultimate loads. The experimental results indicate that the web opening in the shear span of the beams shows a significant reduction in the ultimate load capacity. For predicting the ultimate load carrying capacity for deep beams with opening, Eq. of Kong & Sharp (1977) used. Comparison between experimental finding and numerical results showed a good agreement with experimental results of ultimate load capacity of beams with opening.


Article
Effect of WEB Opening on the Analysis of Cellular Plate Structures of Varying Depth by Grillage Method

Author: Meethaq Sh. Al-Fatlawi
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2005 Volume: 24 Issue: 5 Pages: 507-523
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract


Article
Effect of Web Opening on the Ultimate Capacity of Steel Plate Girders under Two Points Load
تأثير الفتحة في وترات الروافد اللوحية الفولاذية على الحمل اللاقصى تحت حمل نقطتين مركزتين

Author: Mazin A. Al-Mazini
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2016 Volume: 34 Issue: 1 Part (A) Engineering Pages: 165-177
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

The structural behavior of steel plate girders with web opening is investigated in this study. An experimental and theoretical investigation of plate girders with circle and square openings in the web was conducted. The experimental work included testing of seven plate girder specimens under two point loads. Three specimens were tested to observe the influence of the circular web opening. The influence of the presence of square web openings was studied by testing other three specimens. The last one was tested without opening as a reference (control) specimen. These specimens had the same dimensions. The experimental results showed that the ultimate load capacity of the girders decreases with increasing the opening size, and the position of plastic hinge depends on the size of hole. Three-dimensional nonlinear finite element analysis has been used to conduct the numerical investigation of the structural behavior of plate girders with web opening. ANSYS (version 12.0) computer program was used in this study. Four- nodes shell element (SHELL 181) was used to represent the steel plate. The proposed finite element model has been used to carry out a parametric study to investigate the effects of two parameters; web slenderness and flange stiffness ratios, on the ultimate load capacity of plate girders with circular web openings.

في هذه الدراسه تم بحث السلوك الانشائي للعوارض اللوحية ذات الوترات المثقوبة تمت الدراسة عمليا ونظريا للعوارض اللوحية ذات فتحات دائرية ومربعة الشكل. تم فحص سيعة نماذج وتحت تأثير نقطتين تحميل. فحصت ثلاث نماذج لمعرفة تأثير وجود الفتحات الدائرية الشكل وثلاث نماذج اخرى فحصت لمعرفة تأثير وجود الفتحات المربعة الشكل. بينما النموذج السابع كان بدون فتحات في وتراتها حيث يمثل النموذج المرجع (المقارنة) لبقية النماذج. اظهرت النتائج العملية على أن الحمل الأقصى للعوارض اللوحية يقل بزيادة حجم الفتحة وكذلك أن موقع المفصل البلاستيكي يعتمد على حجم الفتحة


Article
Torsional Resistance of Reinforced Concrete Girders with Web Openings
مقاومة اللي للأعتاب الخرسانية المسلحة حاوية على فتحات وترة

Authors: Mohannad Hussain Al-Sherrawi مهند حسين الشراوي --- Zainab Muthana Shanshal زينب مثنى شنشل
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2016 Volume: 22 Issue: 2 Pages: 137-155
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

In this study, a three dimensional finite element analysis was utilized to study the behavior of reinforced concrete T-girders with and without web openings under pure torsion by using ANSYS APDL 15.0 program. Fourteen reinforce concrete T- girders were analyzed; one of the girders (without web openings) was modeled as a control girder. The analysis variables considered for the other girders are: size, shape, position of web openings, number of web openings and the method was used to strengthen the member at openings, (using internal deformed steel bars as in the case where the openings are planned before casting the girders). To study the general behavior of finite element models, torque-angle of twist plots at the end of the span near the loaded arms were represented. From this relation, it was showed a decreasing in the strength of the T-girders with web openings under the torsional loads and increasing of the angle of twist. The results were analyzed in terms of torque twist characteristics; ultimate torque, crack patterns, crack width, warping and stresses. These terms were presented and a comparison between the finite element results was made.

تم من خلال هذا البحث دراسة سلوك العتبات الخرسانية المسلحة لعتبات بشكل T الحاوية على فتحات وعتبات بدون فتحات تحت تأثير عزم اللي الصرف; تمت نمذجة العتبات بأستخدام طريقة العناصر المحددة لنماذج ذات ابعاد ثلاثية بأستخدام برنامج ANSYS APDL 15.0، حيث تم تحليل اربعة عشر نموذج احدها بدون فتحه والذي يعتبر النموذج المصدري حيث تم مقارنة نتائج بقية النماذج معه. المتغيرات التي تم استخدامها عند دراسة المقارنة مع االنماذج الأخرى هي: حجم وشكل وموقع وعدد الفتحات المستخدمة وطريقة تقوية الفتحات التي تتم بأستخدام تسليح داخلي حول الفتحات عند التصميم. ولأجل دراسة العلاقات المتعلقة بالنماذج والمصممة بطريقة العناصر المحددة, كالعلاقة بين عزم اللي الصرف وزاوية الألتواء والتي تم قياسها عند نهاية مقطع العتبة القريبة من الذراع الذي يسلط عليه الأحمال, وبشكل عام ومن خلال هذة الدراسة وجد تناقص في مقاومة العتبات لعزوم اللي الصرف وزيادة في مقدار زاوية عزم الألتواء عند وجود الفتحات .و تمت ايضا دراسة نتائج حساب اقصى عزم التواء وشكل وسمك التشققات ودراسة الأنحناءات والأجهادات وتم اجراء مقارنة فيما بينها.


Article
EFFECT OF WEB OPENING ON THE AXIAL LOAD CAPACITY OF STEEL COLUMNS WITH COLD FORMED THIN WALLED SECTION (CFS)
تاثيروجود الفتحات في وترة المقاطع الفولاذية ذات الجدران النحيفة المشكلة على البارد على تحمل الاحمال المحورية للاعمدة الفولاذية

Authors: Sadjad Amir Al-Jallad سجاد عامر حمزة الجلاد --- Haitham Al-Thairy هيثم علي بادي الثائري
Journal: KUFA JOURNAL OF ENGINEERING مجلة الكوفة الهندسية ISSN: 25230018 Year: 2016 Volume: 7 Issue: 3 Pages: 13-26
Publisher: University of Kufa جامعة الكوفة

Loading...
Loading...
Abstract

In this paper, an experimental study has been presented to investigate the effects of web opening on the behavior and failure of steel columns with cold formed thin walled sections (CFS) subjected to axial compressive load. Twenty small scale steel columns with cold formed box and channel sections and a total length of 500 mm have been considered in the experimental tests. Ten of the tested steel columns specimens have a box section with dimensions of (100×100×2) mm (height × width× thickness), and the other ten columns specimens have a channel sections with dimensions of (100×50×2) mm (height × width× thickness). To investigate the effect of the number and the shape of web opening on the axial compressive strength of steel columns, each ten columns with same cross section shape was divided into three groups of three columns in addition to the reference column which has no web openings. All groups of columns have same opening area which is located at the web of the section, but each group has a different opening shape (square, rectangular, and circular shapes), and each steel column within each group has different numbers of opening distributed along column length (one, two, and three openings). Each steel column specimens was subjected to an increasing static load up to column failure which indicated by the reloading of the test machine. The study has shown that for most of the tested columns, increasing the numbers of web openings results in decreasing the column axial strength compared to the reference steel column. The maximum percentage of the reduction in the columns axial compressive strength caused by the presence of web opening was found to be about 30% and 45% of the reference columns strength for columns with box and channel shape sections, respectively. It has also been found that the reduction in the axial compressive strength of the column specimens caused by the presence of web openings is lower for the circular shape openings compared to that for rectangular and/or square shape web openings.

يقدم هذا البحث دراسة عملية لتاثير الفتحات في منطقة الوترة على تصرف و فشل الاعمدة الفولاذية المكونة من مقاطع نحيفة الجدران. و المعرضة الى قوة انضغاط محورية . تم اخذ عشرين نموذج مصغر لاعمدة فولاذية بطول كلي يبلغ 500 ملمتر و بمقاطع بشكل صندوفي و مقاطع بشكل قناة مشكلة على الطريقة الباردة .عشرة من نماذج الاعمدة الفولاذية تتالف من مقاطع بشكل صندوقي وذات ابعاد 100×100×2 ملمتر (طول ×عرض×سمك) و العشرة الاخرى من نماذج الاعمدة تتالف من مقاطع بشكل قناة و بابعاد 100×50×2 ملمتر (طول ×عرض×سمك). لمعرفة تاثير شكل و عدد فتحات الوترة على تصرف و تحمل الاعمدة الفولاذية للقوة المحورية, تم تقسيم كل عشرة اعمدة بنفس شكل المقطع العرضي الى ثلاث مجاميع كل مجموعة تتالف من ثلاث اعمدة اضافة الى العمود المرجعي غير الحاوي على فتحات . كل مجموعة من الاعمدة الفولاية تحتوي على نفس مساحة الفتحة الواحدة الموجودة في منطقة الوترة ولكن كل مجموعة تحتوي على شكل معين للفتحات (مستطيل, مربع, و دائري) و كل عمود من الاعمدة الثلاثة ضمن كل مجموعة يحتوي على عدد مختلف من الفتحات ضمن منطقة الوترة (فتحة واحدة, فتحتان و ثلاثة فتحات). تم تسليط حمل محوري ستاتيكي متزايد منتظم على كل عمود لمعرفة اقصى حمل محوري ممكن تحملة من قبل كل عمود. تم الاستنتاج انه في اغلب الاعمدة الفولاذية التي تم فحصها في هذه الدراسة فان زيادة عدد الفتحات في منطقة الوترة تؤدي الى نقصان ملحوص في مقاومة العمود لقوة الانضغاط المحورية بالمقارنة مع مقاومة العمود المرجعي. لقد اظهرت النتائج ايضا ان النقصان في مقاومة العمود للقوة المحورية تكون اقل عند استخدام فتحات دائرية الشكل بالمقارنة مع النقصان الحاصل في مقاومة العمود للقوة عند استخدام فتحات مسنطيلة او مربعة الشكل.